BioPROtect III. and BioPROtect III Jr. Class II Style Walk-In Clean Air and Containment Enclosures.

Similar documents
SterilSHIELD. Designed for Aseptic Compounding of Non-Hazardous Pharmaceuticals. SterilSHIELD Barrier Isolator (positive pressure)

A viewscreen top hinge allows full opening for loading of instrumentation or equipment.

PHARMACY Products. Compounding Aseptic Containment Isolator (CACI) A level of safety that is built in, not bolted on. Underwriter Laboratories Listed

PHARMACY Products. Compounding Aseptic Isolator (CAI) Positive pressure sterility assurance barrier isolator for complete product protection.

As ept i c I s olator s

SterilGARD III Advance Sets the Industry s Highest Standard for Comfort, Performance and Safety.

The better choice for an optimum balance of energy efficiency with performance. Class II, Type A2 Biological Safety Cabinet, Vertical Flow

The better choice for an optimum balance of energy efficiency with performance. Class II, Type A2 Biological Safety Cabinet, Vertical Flow

SterilGARD. Meets NSF Standards. Underwriter Laboratories Listed

The better choice for an optimum balance of energy efficiency with performance. Class II, Type A2 Biological Safety Cabinet, Vertical Flow

The better choice for an optimum balance of energy efficiency with performance. Class II, Type A2 Biological Safety Cabinet, Vertical Flow

BioChemGARD. Meets NSF Standards. Underwriter Laboratories Listed

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

Best Products. Best Performance. Best Protection.

Controlled Environment Equipment Solutions for the Lab

NU-430/435 CLASS II, TYPE B2 BIOLOGICAL SAFETY CABINETS

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL

Thermo Scientific 1300 Series A2. Class II, Type A2 Biological Safety Cabinets. Good for you good for the environment

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS

Biological Safety Cabinet

BSC-1100IIA2-X is designed to meet the operating principles:

PRODUCT CATALOG CLASS II BIOLOGICAL SAFETY CABINET.

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

PURCHASE SPECIFICATIONS FOR NUAIRE PHARMAGARD NU-NR797 NEGATIVE PRESSURE RECIRCULATING STERILE ISOLATOR

Class II biological safety cabinets

PCR Laminar Flow Cabinets

Biological Safety Cabinet. Feature & HEPA-filter efficiency

Smart design has its rewards. NEW! Thermo Scientific MSC-Advantage Class II Biological Safety Cabinet. Part of Thermo Fisher Scientific

General. Technical Bulletin: ACCESSORY INFORMATION

Ductless Nanoparticle Containment Enclosures

High Performance Ductless Balance Enclosures

Ductless Nanoparticle Containment Enclosures

LABGARD FEATURES

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Protector Demonstration Hoods

Fixed Range Exhaust Flow Canopies for NU 540 (Series 1 ), NU 543 (Series 1 ) Class II, Type A2, Biological Safety Cabinets

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

Protector Glove Boxes.

OPERATOR S MANUAL. Baker SterilGARD III Advance Animal Transfer Station Biological Safety Cabinet MODEL SG403ATS/ SG603ATS

ADVANCED SAFETY ENGINEERING FOR EFFECTIVE HANDLING OF HAZARDOUS PARTICULATE DRUGS AND POWDERS IN A CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET

Series. Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry

Envirco BIOLOGICAL SAFETY CABINET

convenience. containment. comfort. Thermo Scientific Class II, Type A2 Biological Safety Cabinets

DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

LAMINAR AIRFLOW EQUIPMENT

Ductless Nanoparticle Containment Enclosures

(Class II Type A2 & B2)

January, 2014 Page 1 of 6

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

CLASS II BIOSAFETY CABINET

OPERATOR S MANUAL. Class II, Type A2 Biological Safety Cabinet MODELS:

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

After installing the HEPA filters the discharge air should be monitored to ensure proper filtering efficiency. HEPA Filters

Ventilated Balance Enclosures

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7

PROTECTOR FIBERGLASS ENCLOSURES

INSTALLATION INSTRUCTIONS

Series 577. Vertical Flow Softwall Portable Cleanroom. Series 577 Vertical Flow Softwall Portable Cleanroom

is with a variety of standard dimensions. Also our units can be custom engineered to any size.

(Class II Type A2 & B2)

Affordable portable filtration unit

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

MODEL 950C-NP-UV Installation and Owners Manual

Further information: Berriman Associates Model 850P.2 Owners Manual

A Thermolab Group Company. HyZone. Class II Microbiological Safety Cabinets. for operator, environment and product protection.

CG2010 Cytogard Cytotoxic Drug Safety Cabinets

PRECISE. Glove Boxes

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

Requires Ductwork and Blower

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

biolus BIO SAFETY CABINET

Quest H5. Quest Dry. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest H5:

Class II, Biological Safety Cabinets Probably the Most Advanced Energy-Efficient, Safe, and Ergonomic Biosafety Cabinet in the World

VCM LAMINAR FLOW HOOD VERTICAL

Operating Manual PFB-2500

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

OmniAire Portable Air Cleaner OA1200PAC

AS , EN12469 (Microbiological Testing Method)

Protector Controlled Atmosphere Glove Boxes

Class II Biological Safety Cabinets The World's Most Energy Efficient, Quiet, and Compact Biosafety Cabinet

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy

Esco Ascent Max Ductless Fume Hood

FAN POWERED HEPA FILTER UNIT

F. VAV hoods shall have a restricted bypass plate.

General Application Ductless Fume Hoods

Antech Group Inc. Tel/Fax: Web: SOLUTIONS

Protector Multi-Hazard Glove Box

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

How to Use a Chemical Fume Hood Safely

Appendix C: Biosafety Cabinet Specifications C-2. Product Service

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

VERSAFLOW SERIES UNIDIRECTIONAL LAMINAR AIRFLOW COMPOUNDING ASEPTIC ISOLATOR (CAI)

Revolutionizing Clean Environments Containment. Comfort. Convenience

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Fume Hood Program. Program originated: 08/2008 Updated: 06/2016. Gordon Krueger Environmental Safety Specialist

Cytotoxic Safety Cabinet The Premium Solution for Cytotoxic Drug Processing. Esco Cytoculture Cytotoxic Safety Cabinet Model CYT-4A_

Model ND-2 Specification

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

Transcription:

BioPROtect III Class II Style Walk-In Clean Air and Containment Enclosures. BioPROtect III and BioPROtect III Jr. The BioPROtect III, shown with optional stainless steel cart. Clean Air and Containment The Baker Company BioPROtect III and III Jr. are Class II style clean air and containment enclosures designed for high-volume robotic and automated equipment applications. The BioPROtect III accommodates high-throughput robotic systems (including ancillary devices), ultra-centrifuges, flow cytometers, aerosol generators and other large pieces of laboratory equipment. BioPROtect III offers clean air and containment while allowing access to the spacious 164 cu.ft interior work area (nominal) through combination double doors and 8" sash opening. BioPROtect III Jr. has single-door access with a 78 cu.ft. interior volume (nominal). General Design and Performance Features BioPROtect III 164 cu.ft. interior, 76"H x 102"W x 36.5"F-B, nominal BioPROtect III Jr. 78 cu.ft. interior, 76"H x 49"W x 36.5"F-B, nominal Ideal for high-throughput screening, combinatorial chemistry, drug discovery, immunology, tissue culture, clinical research, molecular biology and quality control assays. High-performance airflow system provides optimum protection against airborne particulates and aerosols for personnel, product and the environment. HEPA-filtered, particulate-free airflow throughout the work area provides an aseptic environment and minimizes cross contamination. Modular construction allows disassembly for shipping, delivery and placement; cabinet design simplifies assembly and installation prior to certification. Factory direct installation and/or installation supervision is available. BioPROtect III Jr. features the full performance of BioPROtect III in a smaller cabinet. The reach-in/walk-in cabinet offers ample space for mobile cart (shown, not included), process equipment or instrumentation. StediVOLT

Class II, Type A2 Biocontainment Applications The BioPROtect III enclosures are designed for aseptic product preparation and biological investigation involving agents of low to moderate risk. The BioPROtect III may be exhausted back into the laboratory or connected to an in-house exhaust system. Design and Performance Features BioPROtect III incorporates a highperformance airflow system which reduces cost of ownership. Baker s new StediFLOW VFD (variable frequency drive) motor controller uses less energy, reduces heat output and operates more quietly. Superb airflow characteristics deliver unidirectional, downflow air over the work area for maximum product protection. Supply and exhaust HEPA filters are rated at 99.99% minimum efficiency in capturing 0.3 micrometer particles. When exhausted back into the room, the BioPROtect III eliminates ceiling height restrictions in airflow. 14 1 8 9 15 10 3 13 4 12 11 2 5 Protection From Particulates Protection From Gases and Vapors BioPROtect III Containment and Protection Exhausted to room Protects personnel, product and the environment Exhausted to untreated facility exhaust system Protects personnel, product and the environment Protects personnel Exhausted to treated facility exhaust system Protects personnel, product and the environment Protects personnel and the environment If installed to the facility exhaust system by a canopy connection, the BioPROtect III provides particulate protection, plus additional protection of personnel from small quantities of vapors and gases. If the facility exhaust system is specially treated with activated charcoal, scrubbing or catalytic conversion, protection from exhausted vapors and gases is extended to the environment. 1 BioPROtect III Design Features 1 Pressure gauge monitors operation. 2 Exhaust HEPA filter for personnel and environmental protection. 3 Energy efficient fluorescent lighting, externally mounted, with solid-state ballasts to reduce flicker, minimize heat output, improve eye comfort, and extend lamp life by as much as 50%. 4 Supply HEPA filter for product and process protection is easily accessible from inside. 5 Optional air and vacuum petcock adapters. 6 Front air capture grille. 7 Dual doors (single door on BioPROtect III Jr.) allow flexible access for loading 6 and handling of large carts and robotics systems. 8 Independent ground-fault interrupt (GFI) outlets with selfresetting circuit breaker for user safety. 9 Remote circuit breakers for each sidewall duplex receptacle. 10 Front access to exhaust HEPA filters. 11 Stainless steel interior. 12 Optional stainless steel cart. 13 8" fixed sash opening. 14 Baker s new StediFLOW VFD (variable frequency drive) motor controller uses less energy, reduces heat output and operates more quietly. 15 Straight back wall easily accommodates most lab apparatus and instrumentation. 7 1 Note: BioPROtect III is not designed for use with large quantities of volatile chemicals. The adequacy of this enclosure should be determined by an industrial hygienist or safety officer. P a g e 2 8 0 0. 9 9 2. 2 5 3 7 w w w. b a k e r c o. c o m

BioPROtect III Supply and Exhaust HEPA Filter Performance Because HEPA filters remove microorganisms and airborne particulates (generally called aerosols) from the air, the quality, performance and useful life of supply and exhaust filters are critical considerations in the biosafety environment. Each HEPA filter is scan-tested for leaks and tested for overall efficiency by the manufacturer, then individually scantested by Baker to assure leak-free performance. Minimum HEPA filter efficiency is 99.99% for particulates of 0.3 micrometers, with increased efficiency for particulates greater and smaller than 0.3 micrometers. The supply HEPA filter pulls down from above the interior work area. The exhaust HEPA filter can be inserted and removed from the front of the cabinet. A closed-cell neoprene gasket provides an airtight seal between the filter assembly and the metal plenum. Blower/Motor System Baker s new StediFLOW VFD (variable frequency drive) motor controller uses less energy, reduces heat output and operates more quietly. VFD is stateof-the-art technology in HVAC systems for performance and energy savings. The BioPROtect III cabinet can automatically handle an increase in pressure drop of more than 250% across the filter without reducing total air delivery more than 10%. There is no need for manual speed control. Maintains precise airflow. Reduces amperage required by 40 60%, as compared with original models. Automatically compensates for normal power line variations, air disruptions and filter loading. Constant air volume reduces risk of performance degradation, which can compromise personnel and product protection. Easier On-Site Installation, Certification and Testing Several BioPROtect III design features combine to simplify on-site assembly, certification and maintenance for qualified service personnel, thus reducing downtime and improving life cycle costs. The modular design allows on-site assembly with commonly available tools. Baker offers a choice of factorydirect installation or factory-supervised installation; contact The Baker Company for details. Once installed, the plenum assembly places supply and exhaust HEPA filters within easy reach, allowing the filters to be clamped directly to the plenum against the closed-cell neoprene gasket. Comfortable Lighting Improves Visibility, Reduces Heat Ergonomic benefits of the BioPROtect III include externally mounted fluorescent lamps and electronic ballasts which provide better visibility at the work surface, less heat at the face (front) of the cabinet, and improved user comfort. Electronic ballasts eliminate fluorescent lamp flicker, minimizing eyestrain and improving productivity. The warm, natural illumination exhibits better color fidelity. Cabinet Construction Enhances Performance, Minimizes Downtime Baker cabinet designs represent many years of experience in stainless steel fabrication and craftsmanship. Design considerations such as aerodynamically shaped surfaces and non-glare satin finish interiors combine to improve comfort, simplify cleaning and maintain proper containment. Corrosion-resistant, 16-gauge, Type 304 stainless steel interior surfaces permit easy cleaning. The stainless steel floor retains spills. A protective grille located at return air plenums prevent wipes and other paper materials from being inadvertently drawn into the blower system, eliminating costly decontamination and downtime to extract materials from the blower. The position of the stainless steel air diffuser/filter protector located below the supply filter in the work area provides added filter protection. The 16-gauge, cold-rolled steel exterior cabinet is protected with a white powder coat finish. P a g e 3

Electrical System Offers Safety and Convenience The BioPROtect III electrical system is designed for safety and convenience. GFI duplex outlets are provided to accommodate high-throughput and robotic instrumentation, centrifuges and other equipment. Each outlet is provided with a dripproof cover and self-resetting circuit breaker. The internal work area outlets are on a separate circuit from the cabinet lights and blower/motor so that an overload caused by research equipment will not affect cabinet function. Options and Accessories For convenience, most options, accessories and modifications are factory installed and should be specified when ordering. Commonly requested options are listed below. For detailed information on accessories and modifications, refer to Baker Accessories literature, or contact The Baker Company. LE (Low Edition) model available for installations in laboratories with 8' ceilings All stainless steel lift cart with casters Service petcocks (specify label and location) Additional electrical outlets, 115V, 220V or 440V (specify location) Blower/Motor switch with additional pole for interlocking with facility exhaust system Replaceable service panels with cut-outs for conveyors can be positioned on either or both sides To Order For applications assistance and ordering information, terms and conditions of sale, contact The Baker Company toll-free USA 800-992-2537 or 207-324-8773, e-mail your request to bakerco@bakerco.com, or visit our Web site at www.bakerco.com. Note: BioPROtect III is not designed for use with large quantities of volatile chemicals. The adequacy of this enclosure should be determined by an industrial hygienist or safety officer. Summary Specification BioPROtect III Class II Style Clean Air and Containment Enclosure Model Number: BioPROtect III Cabinet Type: Walk-in/Reach-in Clean Air and Containment Enclosure Site Preparation Model Electrical System, 60Hz Exhaust Requirement When unit is exhausted to building system Duct Diameter BioPROtect III and LE Models Three 115V junction boxes, 20 amps each Canopy Connection (CEC): 700 CFM, 0.15 to 0.25" water column suction, total Two (8") ducts BioPROtect III Jr. One 115V junction box, 20 amps Two 115V junction boxes, 15 amps Canopy Connection (CEC): 350 CFM, 0.03 to 0.045" water column suction, total One (8") duct Filtration System Exhaust and supply filters are standard HEPA filters with an efficiency of 99.99% when filtering particles of 0.3 micrometers P a g e 4

BioPROtect III 96 1 /2" 47 9 16" 11" Junction Box Right Side Outlet 120V, 20 AMPS Junction Box Left Side Outlet and Lights 120V, 15 AMPS Junction Box Blowers 120V, 20 AMPS 63 1 /5" 61 9 /64" Exhaust HEPA Filter Electrical Console Switch Console Supply HEPA Filter 107 1 /4" Over Exhaust Canopy 102 1 /2" Over Junction Boxes 25 3 /4" 8" Sash Opening 41 1 /4" 79 1 /2" 66 1 /2" 12" Work Table Travel 39 1 /16" 27" Min. Table Height BioPROtect III Vent to Building HVAC System Shown 116 5 /8" 46 3 /10" Base Pan 50" Foot Print Height Adjustable Cart Has 8" Non-Swivel Locking Casters 102 1 /2" Over Junction Boxes 8" Sash Opening 71 1 /4" 49 1 /4" 66" Max. BioPROtect III Jr. Vent to Lab System Shown Room Air Combined Room & HEPA Supply Air Exhausted HEPA-Filtered Air HEPA-Filtered Supply Air P a g e 5

BioPROtect Purchase Specification BioPROtect III and BioPROtect III Jr. Class II Style Clean Air and Containment Enclosure 1. Manufacturer shall provide a certified copy of the personnel and product (biological) tests via modified NSF International Standard #49, performed on the unit. 2. Viewscreen shall be constructed of 3 /8" scratch-resistant polycarbonate with a fixed opening of 8" for access. 3. All biologically contaminated ducts, plenums and work area side walls shall be permanent metal construction and maintained under negative pressure or enclosed within a negative pressure zone. 4. Audible and visible alarm system shall be provided to indicate low exhaust airflow. 5. Intake velocity through the 8" front access opening shall be 100 FPM (Type A2). 6. Unit shall exhaust 490 (nominal) CFM of air with an average of 100 FPM (Type A2) calculated air intake through front access opening at 8" operating level. BioPROtect III Jr., 245 CFM (nominal). 7. Cabinet exterior construction: seal panels of 16-gauge cold-rolled steel and dress panels of 18-gauge cold-rolled steel, baked enamel finish Baker PermaWhite. 8. Cabinet interior (work area) construction: 16-gauge, Type 304 stainless steel. 9. A straight back wall shall be provided to maximize work area and easily accommodate laboratory equipment. 10. Work area shall be provided with GFI protected duplex outlets with drip-proof covers and circuit breakers. 11. Cabinet shall have a stainless steel floor to facilitate cleaning and to contain spills. 12. Stainless steel air diffuser and filter protector provided in work area. 13. Speed controller shall automatically compensate for line voltage changes to maintain constant voltage to motor while allowing for manual adjustments to accommodate filter loading. 14. Unit shall have standard HEPA filters with an efficiency of 99.99% when filtering particles of 0.3-micron size. 15. Unit shall have electronic ballasts for fluorescent lighting to provide longer life and lower heat output. 16. Unit will utilize high efficiency VFD motor blowers. 17. Unit will be provided with left and right side 3" diameter cable ports. 18. Unit shall be culus listed for electical, fire and personal safety. Warranty The Baker Company, Inc., expressly represents and warrants all goods (a) to be as specified (and described) in The Baker Company catalogs and literature, and (b) to be free under normal use, service and testing (all as described in The Baker Company catalogs and literature) from defects in material and workmanship for a period of twelve months from the invoice date. The exclusive remedy for any breach or violation of this warranty is as follows: The Baker Company, Inc., will F.O.B. Sanford, Maine, furnish without charge repairs to or replacement of the parts or equipment which proved defective in material or workmanship. No claim may be made for any incidental or consequential damages. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OF IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE UNLESS OTHERWISE AGREED IN WRITING SIGNED BY THE BAKER COMPANY. (THE BAKER COMPANY SHALL NOT BE RESPONSIBLE FOR ANY IMPROPER USE, INSTALLATION, SERVICE OR TESTING OF THE GOODS.) Specifications subject to change without notice. P.O. Drawer E, Sanford, Maine 04073 (207) 324-8773 1-800-992-2537 FAX (207) 324-3869 www.bakerco.com 2010 The Baker Company 134-043-10 11/10