Ⅱ {
SPECIFICATION MODEL HBG-60-10 HBG-60-10 HBG-60-2 OUTPUT INPUT RATED CURRENT CURRENT ACCURACY EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT SHORT CIRCUIT PROTECTION OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY & EMC OTHERS RATED POWER MTBF DIMENSION PACKING 10mA 10mA 2mA CONSTANT CURRENT REGION Note.4 37 ~ 55V 28 ~ 43V 19 ~ 29V CURRENT ADJ. RANGE Note.4 680 ~ 10mA 910 ~ 10mA 1360mA ~ 2mA RIPPLE & NOISE (max.) Note.2 ±5.0% 57.75W 60.2W 60.9W NO LOAD OUTPUT VOLTAGE (max.) 60V V 35V SETUP TIME VOLTAGE RANGE Note.3 FREQUENCY RANGE 0ms / 230VAC 90 ~ 295VAC 47 ~ 63Hz 1200ms / 115VAC at 95% load 127 ~ 417VDC POWER FACTOR (Typ.) PF>0.97/115VAC, PF>0.95/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve) SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY 5Vp-p 4Vp-p 3Vp-p TOTAL HARMONIC DISTORTION THD< 20% when output loading 65% at 115VAC/230VAC input and output loading 75% at 277VAC input MAX. No. of PSUs on 16A CIRCUIT BREAKER 90% 89% 89% 0.7A/115VAC 0.4A/230VAC 0.3A/277VAC COLD START 45A(twidth= μs measured at % Ipeak) at 230VAC 28 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC <0.75mA / 2VAC Hiccup mode, recovers automatically after fault condition is removed Shut down o/p voltage, re-power on to recover - ~ +70 (Refer to "Derating Curve") 20 ~ 95% RH non-condensing - ~ +80, 10 ~ 95% RH ± 0.03%/ (0 ~ 60 ) 10 ~ 0Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL87, CSA C22.2 No. 2.13-12, ENEC EN61347-1 & EN61347-2-13 independent, EN62384 approved I/P-O/P:3.75KVAC I/P-O/P:M Ohms / 0VDC / 25 / 70% RH Compliance to EN515, EN60-3-2 Class C ( 65% load) ; EN60-3-3 Compliance to EN60-4-2,3,4,5,6,8,11; EN61547, EN524, light industry level(surge 2KV), criteria A 452Khrs min. MIL-HDBK-217F (25 ) Enclosed type: ψ110mm * 60.5mm (D * H) PCB type: ψ99mm *26mm (D * H) Enclosed type: 0.5Kg; 20pcs/ 11Kg/ 0.94CUFT PCB type:0.21kg; 32pcs/ 7.7Kg/ 0.68CUFT NOTE To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
Block Diagram fosc : KHz I/P EMI FILTER & RECTIFIERS POWER SWITCHING RECTIFIERS & FILTER +V -V O.L.P. PWM & PFC CONTROL Derating Curve Static Characteristics 80 65 60 90 80 70 LOAD (%) 20 LOAD (%) 60 - -30-25 0 15 30 60 70 AMBIENT TEMPERATURE ( ) (HORIZONTAL) 90 125 135 145 155 165 175 180 200 230 295 INPUT VOLTAGE (V) 60Hz Power Factor Characteristic Constant Current Mode PF 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 % 60% 70% 80% 90% % (60W) LOAD 277V 230V 115V
EFFICIENCY vs LOAD (10mA Model) possess superior working efficiency that up to 90% can be reached in field applications. 91 90 EFFICIENCY (%) 89 88 87 86 277V 230V 115V 85 84 % 60% 70% 80% 90% % LOAD DRIVING METHODS OF LED MODULE This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs. Vo(%) 65% Constant Current area In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL. Hiccup Protection Io(%) Typical LED power supply I-V curve
FS1 C1 + - S G D Q1 D L1 D4 PCB:HBG-60B CN T1 K G A U4 ψ18 60W Single Output LED Power Supply Mechanical Specification Case No.HBG-60 Unit:mm Blank type:(hbg-60-_) 98 57.5 47.5 4 3 98 Tcase 11.2 AC/L(Brown) AC/N(Blue) 30 SJTW 18AWG*2C ψ 79. 200 SVT 18AWG*2C +V(Red) -V(Black) 7.56 27.36 15 29.64 30 4-ψ5.28 ψ108 ψ110 ψ8.36 T case: Max. Case Temperature. P type:(hbg-60-_p) ψ99 26 1.6 HS1 AC/L(Brown) AC/N(Blue) -V(Black) +V(Red) UL1015 18AWG*2C UL1015 18AWG*2C T 2A/2 ZNR1 /VAC LF C125 LF1 BD1 A K A HBG-60A SCR1 C105 C108 C106 C107 Caution Please inspect the appearance of the product for completeness if the package is damaged. There should not be any cracks. Please do not drop or bump the product. All screws including the suspension screw should be paired with a spring washer and locked tight. The entire luminaire, including the power supply should be limited to less than 5Kg. The luminaire should be cautiously protected throughout packaging and transportation to avoid damage due to shock. Please thoroughly perform the cautionary notes above to prevent the possibility of the luminaire falling and injuring personnel.