Instruction Manual & Specification

Similar documents
INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

KD1E Range Potential Indicators

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

User manual ma Loop Calibrator Jofra macal

Operating Instructions

Operators Guide: RoboSign Stop/Go Traffic Control System

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Non-Contact Phase Rotation Tester

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

EASY CHARGE Weather-resistant fixed mount Battery Charger

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

EASY CHARGE Waterproof portable Battery Charger

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Eazipole Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

1.Safe testing IMPORTANT:

OPERATIONAL INSTRUCTIONS

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

KCR1. Kiln Controller Handbook. Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom

HQ-INV300WU-12 HQ-INV300WU WATT DC TO AC MODIFIED SINEWAVE INVERTER WITH USB OUTPUT

Operators Guide: RoboSign Stop/Go Traffic Control System

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Compact Sine Inverter

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

BM kv Digital Insulation Tester USER MANUAL

6 Bay Battery Charger Operation Manual

Elmdene International Ltd

GL1200T Cut & Seal. (GL1200 Seal only)

WENS30C Loop Calibrator

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

OPERATING INSTRUCTION

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

233 True-rms Remote Display Digital Multimeter Safety Information

GL1200T Cut & Seal. (GL1200 Seal only)

Tail Flick Analgesia Meter Users Manual. Hot Plate Analgesia Meter START STOP HARVARD. Temperature C. Time h.mm.ss HARVARD APPARATUS

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No

HIGH VOLTAGE PROVING UNIT

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

1000FLT. Users Manual. Fluorescent Light Tester

Your Guide to the Installation, Care and maintenance of PERFORMA. Electronic Self Closing Fittings - Mains Powered 886V (343029) 885V (343027)

365 Detachable Jaw True-rms Clamp Meter

362 Clamp Meter. Users Manual

Instruction Manual VT25 / VT28 VOLTAGE TESTER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

80 Series V Digital Multimeter Safety Information

PS Bedienungsanleitung. Symbole 3. D PowerStarter 7. GB PowerStarter 15. E PowerStarter 23. F PowerStarter 31.

ADDENDUM to INSTALLATION INSTRUCTIONS for Grant Solar Pump Station

Owner Handbook. Nebula Blizzard v3. Snow Machine. L69500 Nebula Blizzard v3.indd 1 14/07/ :47

707Ex. Users Manual. ma Calibrator

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

USER MANUAL MPS 1-5KW SERIES

Sinergex. PureWatts Elite 150. User's Manual. Sinergex Technologies L.L.C. (USA) Website:

373 Clamp Meter. Users Manual

BATTERY OPERATED DIGITAL MILLI-OHMMETER

Daylight Rechargeable Portable Light

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Car Battery Charger Instructions for Use

28W WORK LAMP Model: CTL28 Part No:

MANUAL. Single charger

Mini Multimeter with Non-Contact Voltage Detector (NCV)

OPERATIONS MANUAL CR Thermoreactor

12VDC TO 230VAC INVERTERS


ML DA 1206 DE 3993 (I) ML DA 1206 DE 3993 (II) -16P027_ML_DA_1206_DE_3993-ML_DA_2407_DE_3993_ _DinA6_ indd

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

PAT120, PAT150 and PAT150R

Cable Length Meter INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

323/324/325 Clamp Meter

Rental Industry Safety Tester Safe Check 5s

TPC. User Manual LED 55N. Cordless LED Curing Light. All instructions in this USER S MANUAL must be completely read before installation or operation.

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

This instrument is manufactured in the United Kingdom. The company reserves the right to change the specification or design without prior notice.

Attention ETCR8600 Leakage Protector Tester To read this user manual carefully. To comply with the operating cautions presented in this manual.

Megohmmeter Test Probe

Non-Contact Phase Rotation Tester

DC Master 24/ A

Getting started with

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13

KEWTECH. KT56 digital multi function tester. Instruction manual

Transcription:

SP200, SP400 & VP400 Proving Units Instruction Manual & Specification VP400 SP200 SP400 SS0019V2 Sn

1. Safety 1.1 Equipment Markings Caution - refer to the instruction manual Construction is double insulated Product should be recycled as electronic waste Conforms to EU standards 1.2 Operational Safety Warning - Risk of Electric Shock! The proving unit generates up to 690V. The Socket and See SP200, SP400 and VP400 proving units are designed to be used by skilled persons in accordance with safe methods of work. If the proving unit is used in a manner not specified by Socket and See, the protection provided by it may be impaired. Inspect the proving unit before using. If any damage is visible such as cracks in the casing the unit should not be used. Before use ensure the proving unit is free from moisture, grease and dust. If the unit requires cleaning use a soft dry cloth only. 2

2. Description The UK designed SP200, SP400 and VP400 Proving Units provide a safe and reliable means of checking the correct operation of Multimeters and two pole voltage Indicators (VI). The SP200 and SP400 are powered by 6 x AA alkaline batteries whereas the VP400 is designed to be permanently mounted in a vehicle and operated from its 12V supply. 2.1 Features Intelligent voltage ramp for testing multimeters and VI s. Generates outputs from 50-690V with a true AC waveform at 50Hz. This means it will always read correctly using the AC range of your tester or multimeter. The SP400 and VP400 proving units both have a non-contact voltage detector facility. Powerful enough to light old filament style lamps. Automatic operation and turn-off for ease of use and battery conservation. 2.2 Indication The voltage ramp indication on all proving units is displayed clearly using red LEDs. The SP400 and VP400 indicate at 50-110-230-400 V The SP200 indicates at 50-100-230-400-690 V All proving units have a blue LED Power indicator that will flash to indicate when batteries need to be changed. SP400 Proving a Socket and See VIP ESI Voltage Indicator 3

3. Usage 3.1 Battery Installation and Status The SP200 and SP400 use 6 x LR6 AA alkaline batteries. Do Not use rechargeable batteries. The batteries are accessible by removing two screws on the rear of the units case. Ensure all testers are disconnected before accessing batteries. Do not mix old and new batteries. For maximum life use only good quality batteries. Dispose of batteries as required by local regulations. The Blue power LED will flash when in operation if the batteries need to be changed. The VP400 is designed to the hard wired into the 12V supply of a vehicle. The supply should be taken from a fused outlet. RED (12V) and BLACK (0v). An extra Isolating circuit within the proving unit maintains safety even in single fault conditions. 3.2 Operation Non contact voltage tester push button. (Not applicable on SP200). Red voltage indication LEDs.(SP200 Includes a 690V LED.) Non contact voltage detector test area. (Not applicable on SP200) Blue power indication LED. (Flashes when battery needs changing). Voltage indicator test points. Unit shown SP400 4

3.3 How to Use 1) Prove your voltage indicator (VI) is working by placing a probe in each test point. Contact the bottom with the right hand probe then apply gentle downward pressure on the left hand probe. This will activate a micro switch, the blue power LED will illuminate and the proving unit will launch into Auto Prove Mode. 2) The Proving Unit will automatically step up to 690V. (On the SP400 and VP400 the 400V LED is used to indicate all voltages greater than 400V). The unit then steps the voltage back down, (690V - 400V - 230V - 100V - 50V - OFF). To reprove the VI again, simply raise and then depress the left hand probe and the Auto Prove Mode will cycle again. Advantages of the Auto Prove Mode Individual voltages are applied at key voltage test points. If the two pole VI draws a high current from the proving unit the Auto Prove mode will pause. This is useful if testing certain types of two pole voltage testers, including those with filament lamps. Significant battery savings as the power is automatically switched off when the proving test is complete. After completion of the auto prove there is a closed circuit between the voltage indicator test points. This means that if your VI has a continuity tester it will prove its operation and sound to confirm completion of the process. 3) Having established that your VI is working correctly carry out the testing required. If you are in doubt at any time use the proving unit to reprove the correct functioning of the VI. 4) Having completed your testing with the VI use the proving unit to ensure that it is still functioning correctly. 5) In addition to two pole VI proving the SP400 and VP400 can test non contact voltage detectors (NCVD). To do this depress the Volt Detector Test button and the red indication LED's and blue power LED should illuminate, as the button is being pressed apply the tip on the NCVD to the Volt Tip Area. Check for correct operation of the NCVD. 5

4. Maintenance and Service If required, clean with a soft, dry cloth. Do not use abrasives or solvents. SP200 & SP400. The only user replaceable parts are the 6 x AA alkaline batteries. VP400. There are no user serviceable parts. Contact Socket and See for parts and technical assistance. Socket and See Century Road High Carr Business Park Newcastle Staffordshire, UK ST5 7UG Tel: +44 (0) 1782 567096 Fax: +44 (0) 1782 567095 Email: sales@socketandsee.co.uk Website: www.socketandsee.co.uk 6

Specification Output Voltage 50-690V in five steps (50V,100V,230V,400V,690V) Safety Compliance BS EN 61010-1:2010 EMC Compliance 61326-1:2006 Operating Conditions Output Frequency Maximum Output power Batteries Battery Life -10 to +35 C at 95% RH 50Hz Pseudo sine wave 10W (SP200 & SP400) 6 x LR6 AA alkaline batteries (VP400) Hard wired into vehicle 12V supply (SP200 & SP400)10 hours with average use when testing high and low power testers. (VP400) N/A Dimensions Weight 68H x 130W x 48D (mm) (SP200 & SP400) with batteries 350g (VP400) 200g 7

Ordering Information Item Socket and See SP200 Socket and See SP400 Socket and See VP400 Supplier Code SOC/SP200 SOC/SP400 SOC/VP400