Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Similar documents
Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE)

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Proportional pressure reducing valve, pilot operated, with inductive position transducer

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Servo solenoid valves with on-board electronics (OBE)

Proportional pressure relief valve with linear curve (Lvdt AC/AC)

Proportional pressure reducing valve, pilot operated

Servo solenoid valves with positive overlap and on-board electronics

3-way servo solenoid valves, cartridge type, pilot operated, with inductive position transducer

Servo solenoid valves with on-board electronics (OBE)

Industrial Hydraulics FAQs

Proportional pressure relief valve, pilot operated

Proportional pressure relief valve

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Servo solenoid valves with on-board electronics (OBE)

Proportional pressure relief valve, direct operated, decreasing characteristic curve

Proportional flow control valve, with inductive position transducer

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Servo solenoid valves with positive overlap and on-board electronics (OBE)

Servo solenoid valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

Servo solenoid valves with electrical position feedback (Lvdt DC/DC ±10 V)

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback and on-board electronics

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback and on-board electronics

Servo solenoid valves with electrical position feedback (Lvdt AC/AC)

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

Servo solenoid valves with positive overlap Position feedback (Lvdt DC/DC ±10 V)

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback (Lvdt DC/DC ±10V)

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Pilot operated proportional directional valves

Electric amplifiers for proportional valves

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

2-way proportional throttle valve for block installation

Proportional flow control valve, 2-way version

3/3 servo directional control valve with mechanical position feedback

Directional servo-valve of 4-way design

Throttle and throttle check valve

Proportional pressure relief valve, directly operated, rising characteristic curve

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

Proportional pressure reducing valve, 3-way variant, pilot operated

Proportional pressure reducing valve, pilot operated

Supply pressure compensator, direct operated

Proportional directional valve, direct operated, with pq functionality

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

3/2 directional spool valve, direct operated with solenoid actuation

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Proportional pressure reducing valve, pilot operated

Proportional pressure relief valve, pilot operated

Proportional flow control valve, with integrated pressure compensator

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

4-way directional servo-valve

Pressure relief valve, pilot operated

Pressure reducing valve, pilot operated

2/2 directional seat valve, direct operated with solenoid actuation

Bourdon tube pressure switch with infinitely variable switching pressure differential

Proportional flow control valve. Type 2FRE. Features. Contents. RE Edition: Replaces: 02.07

Pressure reducing valve, direct operated, with pressure monitoring

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

Proportional pressure reducing valve, in 3-way version

Bourdon tube pressure switch with infinitely variable switching pressure differential

Pressure relief valve, directly operated

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRTE. Features.

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Proportional pressure relief valve Types DBE(M) and DBE(M)E

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Directional servo-valve in 4-way design

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

4/2- and 4/3-way proportional directional valves, direct operated, without electrical position feedback, without/with integrated electronics (OBE)

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB

2/2-way poppet valves with solenoid operation Type KSDER1

Pressure reducing valve, direct operated

Check valve, pilot operated

Pressure relief valve, pilot operated

Pressure relief valve, pilot operated

2-way flow control valve

Proportional pressure relief valve Type DBETRE

Double throttle check valve Type Z2FS 10

3/2 and 4/2 directional seat valves with solenoid actuation

Twin throttle check valve

Directional spool and seat valves with electrical actuation and M12x1 plug-in connection

Pressure reducing valve, direct operated

4-way directional servo valve Type 4WS.2E

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

4/3 directional servo-valve with mechanical position feedback

Pressure sequence valve, direct operated

Transcription:

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback Type DREBE6X Nominal size (NG) 6 Unit series 1X Maximum working pressure P 315 bar, T 250 bar Maximum flow rate 40 l/min List of Contents Contents Page Features 1 Ordering data 2 Preferred types, symbol 2 Function, sectional diagram 3 Technical data 4 to 6 On-board trigger electronics 7 and 8 Characteristic curves 9 Unit dimensions 10 Features RE 29195/05.06 Replaces: 07.05 1/10 Pilot operated valves with position feedback and on-board electronics for reducing system pressure in the consumer (pilot oil internal only) 3-way version (P A/A T), p min = p T Adjustable through the position of the armature against the compression spring Position-controlled, minimal hysteresis < 1 %, rapid response times, see Technical data Pressure limitation to a safe level even with faulty electronics (solenoid current I > I max ) For subplate attachment, mounting hole configuration to ISO 4401-03-02-0-05. Subplates as per catalog sheet RE 45053 (order separately) Plug-in connector to DIN 43563-AM6, see catalog sheet RE 08008 (order separately) Data for the on-board trigger electronics Complies with CE, EMC directives EN 61000-6-2: 2002-08 and EN 61000-6-3: 2002-08 U B = 24 V nom DC Electrical connection 6P+PE Signal actuation Standard 0...+ 10 V (A1) Version 4...20 ma (F1) Valve curve calibrated at the factory

2/10 Bosch Rexroth AG Hydraulics DREBE6X RE 29195/05.06 Ordering data Proportional 3-way pressure reducing valve with inductive position transducer, pilot operated With on-board electronics = E Nominal size = 6 Mounting hole configuration to ISO 4401-03-02-0-05 D E = X = 1X Unit series 10 to 19 (10 to 19: installation and connection dimensions unchanged) Max. pressure stage up to 75 bar = 750 up to 175 bar = 175 up to 310 bar = 310 Without non-return valve Voltage supply of trigger electronics 24 V DC Preferred types DREB E 6 X 1X M G24 K31 M * P A = M = G24 T A1 = F1 = K31 = Further information in plain text M = NBR seals, suitable for mineral oils (HL, HLP) to DIN 51524 Interface for trigger electronics Setpoint input 0...+10 V Setpoint input 4...20 ma Electrical connection without plug-in connector, with unit plug to DIN 43563-AM6 Order plug-in connector separately Type...A1 (0...+10 V) Material Number Type...F1 (4...20 ma) Material Number DREBE6X 1X/75MG24K31A1M 0 811 402 082 DREBE6X 1X/175MG24K31F1M 0 811 402 083 DREBE6X 1X/175MG24K31A1M 0 811 402 080 DREBE6X 1X/310MG24K31F1M 0 811 402 085 DREBE6X 1X/310MG24K31A1M 0 811 402 081 Symbol For on-board electronics

RE 29195/05.06 DREBE6X Hydraulics Bosch Rexroth AG 3/10 Function, sectional diagram General Type DREBE6X proportional pressure reducing valves are pilot operated with a 3-way main stage. The pilot valve (pressure relief valve pilot stage) is supplied internally with a controlled flow of pilot oil via P. The valves are actuated by means of a position-controlled proportional solenoid with on-board electronics. With these valves, the pressure in A (consumer) can be infinitely adjusted and reduced in relation to the setpoint. Accessories EN 61000-6-2: 2002-08 EN 61000-6-3: 2002-08 Proportional solenoid with position transducer Testing and service equipment Test box type VT-PE-TB3, see RE 30065 Measuring adapter 6P+PE type VT-PA-2, see RE 30068 Basic principle To adjust the system pressure in A, a setpoint is set in the trigger electronics. Based on this setpoint, the electronics control the position of the solenoid against the spring force. The proportional solenoid is positioned precisely on the spring characteristic curve. The pilot stage is supplied with oil from P at a flow rate of < 0.6 l/min via a flow control valve. The pilot pressure is compared with the consumer pressure (plus spring) in A and regulated. The spring results in p Amin = p in T. Pressure limitation for maximum safety If a fault occurs in the electronics, so that the solenoid current (I max ) would exceed its specified level in an uncontrolled manner, the pressure cannot rise above the level determined by the maximum spring force. Flow control valve for pilot oil flow Valve body Type Material Number (4 x) f ISO 4762-M5x30-10.9 Cheese-head bolts 2 910 151 166 * Plug-in connectors 6P+PE, KS 1 834 482 022 see also RE 08008 KS 1 834 482 026 MS 1 834 482 023 MS 1 834 482 024 KS 90 1 834 484 252

4/10 Bosch Rexroth AG Hydraulics DREBE6X RE 29195/05.06 Technical data General Construction Pilot stage Poppet valve Actuation Main stage Spool valve Proportional solenoid with position control and OBE Connection type Subplate, mounting hole configuration NG6 (ISO 4401-03-02-0-05) Mounting position Optional Ambient temperature range C 20...+50 Weight kg 3.3 Vibration resistance, test condition Max. 25 g, shaken in 3 dimensions (24 h) Hydraulic (measured with HLP 46, oil = 40 C ±5 C) Pressure fluid Hydraulic oil to DIN 51524...535, other fluids after prior consultation Viscosity range recommended mm 2 /s 20...100 max. permitted mm 2 /s 10...800 Pressure fluid temperature range C 20...+70 Maximum permitted degree of contamination Class 18/16/13 1) of pressure fluid Purity class to ISO 4406 (c) Direction of flow See symbol Max. set pressure in A bar 75 175 310 (at Q min = 1 l/min) Minimum pressure in A bar 0 (relative) or pressure in T Min. inlet pressure in P bar p P = p A + 5 Max. working pressure bar Port P: 315 Max. pressure bar Port T: 250 (B sealed) Internal pilot oil flow l/min approx. 0.6 (with closed-loop control) Max. flow l/min 40 Static/Dynamic Hysteresis % 1 of max. set pressure Manufacturing tolerance % ±5 of max. set pressure Response time 100 % signal change ms 50 Stellzeit 010 % signal change ms 20 Thermal drift < 1 % at T = 40 C Conformity EN 61000-6-2: 2002-08 EN 61000-6-3: 2002-08 1) The purity classes stated for the components must be complied with in hydraulic systems. Effective filtration prevents problems and also extends the service life of components. For a selection of filters, see catalog sheets RE 50070, RE 50076 and RE 50081.

RE 29195/05.06 DREBE6X Hydraulics Bosch Rexroth AG 5/10 Technical data Electrical, trigger electronics integrated in valve Cyclic duration factor % 100 Degree of protection IP 65 to DIN 40050 and IEC 14434/5 Connection Plug-in connector 6P+PE, DIN 43563 Supply voltage Terminal A: Terminal B: 0 V 24 V DC nom Min. 21 V DC/max. 40 V DC Ripple max. 2 V DC Power consumption Solenoid 45 mm = 40 VA max. External fuse 2.5 A F Input, standard version A1 Differential amplifier, R i = 100 kω Terminal D: U E Terminal E: 0...+10 V 0 V Input, ma signal version Terminal D: I D E Terminal E: I D E Max. voltage to differential inputs over 0 V Test signal, standard version Terminal F: U Test Terminal C: Test signal, ma signal version Terminal F: I F C Terminal C: I F C Safety earth conductor and shield Recommended cable Calibration Version A1: Standard 7 5 P F1 A1 F1 Burden, R sh = 200 Ω 4...20 ma Current loop I D E feedback D B E B } max. 18 V DC LVDT 0...+10 V Reference 0 V LVDT signal 4...20 ma at external load 200...500 Ω max. 4...20 ma output Current loop I F C feedback See pin assignment (installation in conformity with CE) See pin assignment up to 20 m 7 x 0.75 mm 2 up to 40 m 7 x 1 mm 2 Calibrated at the factory, see valve curve Supply 24V = Signal: 0 +10V LVDT Signal: 0 +10V (Ri = 100kΩ) A T Version F1: ma signal 1 5 P A Supply 24V = Signal: 4 20mA LVDT Signal: 4 20mA (Bürde: 200Ω) T

6/10 Bosch Rexroth AG Hydraulics DREBE6X RE 29195/05.06 Connection For electrical data, see page 5 and Operating Instructions 1 819 929 083 Technical notes for the cable Version: Type: Multi-wire cable Extra-finely stranded wire to VDE 0295, Class 6 Safety earth conductor, green/yellow Cu braided shield e.g. Ölflex-FD 855 CP (from Lappkabel company) No. of wires: Determined by type of valve, plug type and signal assignment Cable Ø: 0.75 mm 2 up to 20 m long 1.0 mm 2 up to 40 m long Outside Ø: 9.4...11.8 mm Pg 11 12.7...13.5 mm Pg 16 Important Voltage supply 24 V DC nom., if voltage drops below 18 V DC, rapid shutdown resembling Enable OFF takes place internally. In addition, with the ma signal version: I D E 3 ma valve is active I D E 2 ma valve is deactivated. Electrical signals emitted via the trigger electronics (e.g. actual values) must not be used to shut down safety-relevant machine functions! (See also European Standard, Technical Safety Requirements for Fluid-Powered Systems and Components Hydraulics, EN 982.)

RE 29195/05.06 DREBE6X Hydraulics Bosch Rexroth AG 7/10 On-board trigger electronics Circuit diagram/pin assignment Version A1: U D E 0...+10 V Pin assignment Version A1: U D E 0...+10 V (R i = 100 kω) Supply U B Supply zero Ref. zero * Setpoint 0...+10 V Actual valve 0...+10 V Safety earth conductor Shield * Do not connect to supply zero!

8/10 Bosch Rexroth AG Hydraulics DREBE6X RE 29195/05.06 On-board trigger electronics Circuit diagram/pin assignment Version F1: I D E 4...20 ma OBE +U B +15 V -15 V Pin assignment 6P+PE Version F1: I D E 4...20 ma (R sh = 200 kω) DC U + - DC Logic S PID Diff. amp. +U B ma V R sh 200Ω 4 20mA A B C D E F 2.5 AF +24 V= Supply 0 V Supply zero Loop I F C I D E 4...20 ma Test I F C (4...20 ma) Safety earth conductor Shield

RE 29195/05.06 DREBE6X Hydraulics Bosch Rexroth AG 9/10 Characteristic curves (measured with HLP 46, oil = 40 C ±5 C) Pressure in port A as a function of the setpoint Pressure in port A proportionate to the maximum flow rate of the main stage 4,0 7,2 10,4 13,6 16,8 20 U D-E 1 ) [V] I D-E 2 ) [ma] * Factory setting at Q = 1 l/min +5 % manufacturing tolerance (of max. set pressure) 1) Version: U D E = 0...+10 V 2) Version: I D E = 4...20 ma Set pressure p % p max = f (Q P A /Q A T ) D E P A T

10/10 Bosch Rexroth AG Hydraulics DREBE6X RE 29195/05.06 Unit dimensions (nominal dimensions in mm) Mounting hole configuration: NG6 (ISO 4401-03-02-0-05) For subplates, see catalog sheet RE 45053 1) Deviates from standard 2) Thread depth: Ferrous metal 1.5 x Ø Non-ferrous 2 x Ø X Y Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Telefon +49 (0) 93 52 / 18-0 Telefax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de Required surface quality of mating component Not included in scope of delivery P A T B F 1 F 2 F 3 F 4 21.5 12.5 21.5 30.2 0 40.5 40.5 0 25.9 15.5 5.1 15.5 0 0.75 31.75 31 8 1) 8 1) 8 1) 8 1) M5 2) M5 2) M5 2) M5 2) This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.

RE 29195/05.06 DREBE6X Hydraulics Bosch Rexroth AG Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Telefon +49 (0) 93 52 / 18-0 Telefax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.

Bosch Rexroth AG Hydraulics DREBE6X RE 29195/05.06 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Telefon +49 (0) 93 52 / 18-0 Telefax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.