YT-200 / 205 / 220 / 225 Series YT-200 YT-205 YT-220 YT-225 VERSION 1.01

Similar documents
YT-520S YT-520D YT-525S YT-525D YT-530S YT-530D YT-535S YT-535D

YT-720 SERIES. Rotork YTC Limited VERSION 1.07

VOLUME BOOSTER RELAYS YT-310 / 315 SERIES

Electro-Pneumatic Positioner YT-1000 / 1050 SERIES

YT-1200 Series VERSION 1.02

Electro-Pneumatic Positioner YT-1000 / 1050 SERIES

User s Manual. Pneumatic Positioner. Series 58. J Flow. Series 58. J Flow

Pneumatic Positioner RTX - Series USER S MANUAL. ROTEX P/P Ver. 0.1 Dated: MAY / 2009 REV 01: SEP/2010 Page 1 of 16

Pneumatic Positioner PNY Series USER'S MANUAL. Max-Air Technology. Version 1.0

SMART POSITIONER YT-2400 SERIES USER'S MANUAL

SMART POSITIONER YT-2300 SERIES USER'S MANUAL

TMP-3000 VERSION 1.01

Electro-Pneumatic Positioner RTX - Series USER S MANUAL. ROTEX E/P Ver. 0.1 Dated: dd / mm / yy Page 1 of 18

RTX1000 SERIES ELECTRO-PNEUMATIC POSITIONER

YT-1000 / 1050 Series

Operation Manual Electro-Pneumatic Positioner Model: NT-1000R (Rotary Type) NUTORK CORPORATION

SMART POSITIONER YT-2500/2501/2550 SERIES

SMART POSITIONER YT-3300/3301 SERIES

SMART POSITIONER YT-2500 SERIES USER'S MANUAL

SMART POSITIONER YT-3400 SERIES

YT-2600 SERIES VERSION 1.07

Pneumatic cylinder CC Series (Ø200 Ø350)

Pneumatic cylinder SPC Series (Ø32 - Ø100)

SMART POSITIONER YT-2500/2550 SERIES USER'S MANUAL

YT-2500 / 2550 / 2501 SERIES

PRODUCTS CATALOG (2018) TISSIN CO.,LTD. Smart Valve Positioner. Electro-Pneumatic Positioner. Volume Booster. Lock Up Valve. Air Filter Regulator

SMART POSITIONER SS3400 SERIES

SMART POSITIONER YT-3400 / 3450 SERIES PRODUCT MANUAL

BUS DOOR SYSTEM ELECTRO-PNEUMATIC IN-SWING BUS DOOR CONTROL MECHANISM

PMV P36C AND P41C POSITIONERS ACTUATORS

Electro-Pneumatic Linear Positioner Installation and Operation Instructions B GB

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

Electro-Pneumatic Positioner Series 830/831-WP/EX. Operation & Maintenance Manual

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm²

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner

Mounting and Operating Instructions

Temperature Sensor Series

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

ARM1000/2000. Standard Specifications

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

Fisher SS-263 Volume Booster

Owner s Manual & Safety Instructions

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

Installation, Operation & Maintenance Manual

Mounting and Operating Instructions EB EN. Type 3271 Pneumatic Actuator. Actuator area: 1000 cm². Translation of original instructions

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability

Installation & Operation Manual

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

SMART POSITIONER 6000/6050 SERIES

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Models P, P, P, , DANGER

ELECTRONIC CONTROL ACTUATOR

Electric Actuator Driven Compact Ball Valves

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

OBSOLETE DOCUMENT. PRX Series Pilots for Pilot-Operated Pressure Reducing Regulators. PRX Series. Introduction. Product Description

EX Series. Electric Actuators for Ball and Butterfly Valves

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

CV-COSR. Pneumatic Control Valve. Copyright 2013 by TLV CO., LTD. All rights reserved

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

Actuator Driven Compact Ball Valves

specification DAtA V R0 pilot operated tank blanket VAlVe, pressure regulating VAlVe SERIES V500

Fisher 656 Diaphragm Actuator

Adjustable Differential Relay A1

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

PRG 350 Series Stainless Steel Regulators

Air Actuated Dispense Valve

TRANSFER PUMP INSTRUCTIONS P/N 14251NOS

Check Valve Series AK How to Order

Smart Pressure Transmitter

TECHNICAL MANUAL MT029

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

The mechanism that generates mist (moisture) Principles of water removal valve operation

PPM100 Owner s Manual

Pneumatic Control Valve for Steam PN-COSR-16

IMPORTANT SAFETY INSTRUCTIONS

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

Ideal Installation. I & M Mark 80. Bulb Installation PROTECT VALVES WITH LINE STRAINERS

PRG 350 Series Stainless Steel Regulators

THD-2-FM CONTROLAIR VALVE

Ideal Installation. I & M Mark 80. Bulb Installation PROTECT VALVES WITH LINE STRAINERS

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE

4-Way Diverter Plug Valves

INSTRUCTION OIL PUMP. SH-110A5 MODEL No DR-110A5 MODEL No PD-110A5 MODEL No WARNING

Model Series 66 Amplifying and Reducing Relays

BR 31a Rack-and-pinion Actuator,

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves

Transcription:

YT-200 / 205 / 220 / 225 Series PRODUCT MANUAL YT-200 YT-205 YT-220 YT-225 VERSION 1.01

Contents 1. Introduction... 3 1.1 General Information for the users... 3 1.2 Manufacturer Warranty... 3 2. Product Description... 4 2.1 General... 4 2.2 Main Features and Functions... 4 2.3 Label Description... 5 2.4 Product Code... 6 2.5 Product Specification... 6 2.6 Operation Logic... 7 2.7.1 YT-200 / 205 (Manual drain type)... 8 2.7.2 YT-220 / 225 (Manual drain type)... 9 2.8 Product Dimension... 10 2.8.1 YT-200 / 205 (Manual drain type)... 10 2.8.2 YT-200 / 205 (Auto drain type)... 10 2.8.3 YT-220 / 225 (Manual drain type)... 11 2.8.4 YT-220 / 225 (Auto drain type)... 11 2.9.1 YT-200 / 205... 12 2.9.2 YT-220 / 225... 12 3. Installation... 13 3.1 Safety... 13 3.2 Installation... 14 3.3 How to Use... 14 4. Maintenance... 15 4.1 Replacement of Parts (Not applicable for YT-200, 200.)... 15 4.2 Draining condensed water... 15 4.3 Replacing Ass y-diaphragm... 15 Ver. 1.01 2

1. Introduction 1.1 General Information for the users Thank you for purchasing Young Tech Co., Ltd products. Each product has been fully inspected after its production to offer you the highest quality and reliable performance. Please read the product manual carefully prior to installing and commission the product. The manual should be provided to the end-user. The manual can be altered or revised without any prior notice. Any changes in product s specification, design, and/or any components may not be printed immediately but until the following revision of the manual. The manual should not be duplicated or reproduced for any purpose without prior approval from Young Tech Co., Ltd, Gimpo-si, South Korea. In case of any other problems that are not stated in this manual, please make immediate contact to Young Tech co., Ltd. 1.2 Manufacturer Warranty For the safety, it is important to follow the instructions in the manual. Manufacturer will not be responsible for any damages caused by user s negligence. Any modifications or repairs to the product may only be performed if expressed in this manual. Injuries and physical damages caused by customer s modifying or repairing the product without a prior consultation with Young Tech co., Ltd will not be compensated. If any alterations or modifications are necessary, please contact Young Tech Co., Ltd directly. Standard type with NBR rubber (ambient temperature range option 1) is subject to damage by ozone. If you suspect that ozone may be present at the site or if supplied air is likely to contain ozone, select a high temperature version (ambient temperature range option 2) or a low temperature version (ambient temperature range option 3) with SILICONE rubber. Manufacturer warrants the product from the date of original purchase of the product for eighteen (18) months, except as otherwise stated. Manufacturer warranty will not cover products that have been subjected to abuse, accidents, alterations, modifications, tampering, negligence, misuse, faulty installation, lack of reasonable care, repair or service in any way that is not contemplated in the documentation for the product, or if the model or serial number has been altered, tampered with, defaced or removed; damages that occurs in shipment, due to act of God, failure due to power surge, or cosmetic damage. Improper or incorrectly performed maintenance will void this limited warranty. For detailed warranty information, please contact the corresponding local Young Tech Co., Ltd office or main office in South Korea. Ver. 1.01 3

2. Product Description 2.1 General Air filter regulator, YT-200 / 205 / 220 / 225, receives the main supply air pressure and supplies to the desirable level of pressure to a positioner or other pneumatically operating devices. 2.2 Main Features and Functions Maintains desirable pressure level, regardless of fluctuation of the main supply pressure. 5 micron filter filters most particles in the main supply pressure. Relief function is available which discharges to the atmosphere, if the output pressure is higher than setting pressure. By using aluminum or stainless steel body, it has high durability in various environments. Manual or Auto draining is available. Ver. 1.01 4

2.3 Label Description Fig. L-1: YT-200 Fig. L-2: YT-205 Fig. L-3: YT-220 Fig. L-4: YT-225 MODEL : Indicates the model number and any options of the positioner. LOT NO. : Indicates unique lot number. YEAR : Indicates manufactured year. AMBIENT TEMP. : Indicates the allowable ambient temperature for explosion proof. MAX. SUPPLY : Indicates max. supply air pressure level. ADJUST RANGE : Indicates adjusting range of the output pressure. AIR CONNECTION : Indicates connection thread type. Precautions Be careful not to apply volatile solvent (hardener of instant adhesive, acetone, WD-40, etc.) to the sticker nameplate. Printed contents may be erased. Ver. 1.01 5

2.4 Product Code YT-200 / 205 / 220 / 225 1 2 3 4 5 1 Adjustable range A : B : 2 Air Connection type P : N : 3 Gauge 0 : 1 : 2 : 5 Ambient Temperature 1 : 2 : 3 : 7 Option 0 : 1 : 0 ~ 0.42 MPa 0 ~ 0.84 MPa PT (only YT-200 / 220) NPT NONE 0 ~ 0.4 MPa 0 ~ 1.0 MPa -20 C ~ 70 C (-4 F ~ 158 F) -20 C ~ 120 C (-4 F ~ 248 F) -40 C ~ 70 C (-40 F ~ 158 F) Manual drain Auto drain 2.5 Product Specification Model YT-200 YT-220 YT-205 YT225 Max. Supply Pressure Max. Out Pressure 1.7 MPa (17 bar) 0.42MPa (A Type), 0.84MPa (B Type) Air Connection PT(NPT) 1/4 PT(NPT) 1/2 NPT 1/4 NPT 1/2 Gauge Connection PT(NPT) 1/4 PT(NPT) 1/4 NPT 1/4 NPT 1/4 Ambient Temperature Standard High Low -20 C ~ 70 C (-4 F ~ 158 F) -20 C ~ 120 C (-4 F ~ 248 F) -40 C ~ 70 C (-40 F ~ 158 F) Min. Filtering Size 5 micron Housing Material Aluminum Diecasting Stainless Steel 316 Weight 0.6 Kg (1.7 lb) 0.86 Kg (1.89 lb) 1.4 Kg (3.0 lb) 2.1 Kg (4.6 lb) Tested under ambient temperature of 20 C, absolute pressure of 760mmHg, and humidity of 65%. Please contact Young Tech Co., Ltd for detailed testing specification. Ver. 1.01 6

2.6 Operation Logic When 1 the adjustment bolt is turned clockwise, 4 the adjusting spring will take the force pressing 5 the diaphragm and 6 the stem will move downward and the supply pressure (IN) will go out to the secondary output port (OUT). When the pressure on the secondary port reaches set pressure, this pressure is transmitted to the bottom of 5 the diaphragm through the output pressure sensing hole, and the set pressure is maintained by balancing the force with 4 the adjusting spring. If the pressure on the secondary port is higher than the set pressure, the pressure delivered through the output pressure sensing hole pushes up 5 the diaphragm and opens between the diaphragm and 6 the stem. It is discharged to the atmosphere through 3 the spring case hole to maintain the set pressure. Ver. 1.01 7

2.7 Parts and Assembly 2.7.1 YT-200 / 205 (Manual drain type) Ver. 1.01 8

2.7.2 YT-220 / 225 (Manual drain type) Ver. 1.01 9

2.8 Product Dimension 2.8.1 YT-200 / 205 (Manual drain type) 2.8.2 YT-200 / 205 (Auto drain type) Ver. 1.01 10

2.8.3 YT-220 / 225 (Manual drain type) 2.8.4 YT-220 / 225 (Auto drain type) Ver. 1.01 11

2.9 Pressure and Flow Characteristics 2.9.1 YT-200 / 205 2.9.2 YT-220 / 225 Ver. 1.01 12

3. Installation 3.1 Safety When installing a unit, please ensure to read and follow safety instructions. Be sure to have protective equipment and comply with safety regulations. After setting the pressure, secure the nut so that the adjustment bolt does not turn. Supply pressure should be used with clean air. Use within specifications specified in the manual. Exceeding the specification may result in damage to the product or accident. If there is any impact on the product, it may cause malfunction or failure, so be careful during handling, installation and operation. For maintenance, periodically open the drain plug at the bottom of the product to discharge the condensate. Exhaust to the atmosphere are made through a small exhaust hole next to the spring case. Install the product with the adjustment bolt facing up. Otherwise, the life cycle of the product may be shortened or moisture and foreign substance may enter into the vent hole, leading to damaging internal parts. Ver. 1.01 13

3.2 Installation The air filter regulator can be installed with or without a bracket depending on the field conditions. The air filter regulator is used to supply constant air pressure to various devices such as positioner, actuator and solenoid valve. The product can be installed using only pneumatic piping without a separate bracket. Before connecting, be sure to blow out all piping to prevent impurities from entering in to the product and ensure that it is the right size meeting the required capacity. If you require brackets for installation, you can check the dimensions mentioned in the diagram on previous page and make the desired bracket type to suit each models. Below is an example of YT-220 with bracket installation. 3.3 How to Use 1) Before supplying air pressure to the product, turn the adjustment bolt counterclockwise so that the adjustment spring is not pressed at all. 2) Install a pressure gauge on the output port (OUT). This pressure gauge will show the output pressure that is depressurized from the primary pressure (IN). 3) Install pressure gauge and ball valves or other fittings to the outports, and then apply air pressure to the primary input port (IN). 4) Turn the adjust bolt clockwise, and then the secondary pressure goes up to the set value, turn the adjusting nut of the adjusting bolt clockwise to lock it completely to prevent the adjust bolt from moving. Ver. 1.01 14

4. Maintenance 4.1 Replacement of Parts (Not applicable for YT-200, 200.) YT-205 / 225 require regular maintenance.. If necessary, replace the following parts. Ass y-diaphragm : 1 ea 4.2 Draining condensed water When draining out condensed water, the main supply pressure to the product must be shut down completely or adjust the pressure level of 1kgf/cm 2 or below. Slowly open drain plug to drain condensed water. After the draining, please close the drain plug surely. 4.3 Replacing Ass y-diaphragm When replacing the ass y-diaphragm, the main supply pressure to the product must be shut down completely or adjust the pressure level of 1kgf/cm 2 or below. Loosen the nut of the adjust bolt and turn the adjust bolt counterclockwise to completely drop the output pressure to zero. Unscrew 6 bolts on spring case assembly in diagonal direction. Replace the diaphragm assembly. Lock the six bolts back on the spring case assembly. Be careful not to damage the diaphragm due to excessive torque when tightening. Raise the supply pressure to the air filter regulator and turn the adjust bolt clockwise to set the set pressure. Tightened the nut of the adjust bolt. Ver. 1.01 15

Manufacturer: Young Tech Co., Ltd 81, Hwanggeum-ro, 89 Beon-gil, Yangchon-eup Gimpo-si, Gyeonggi-do, South Korea 10048 Tel: +82-31-986-8545 Fax: +82-70-4170-4927 Email: ytc.sales@rotork.com Homepage : http://www.ytc.co.kr Issued : 2018-08-28 Copyright Young Tech Co., Ltd. All Rights Reserved. Ver. 1.01 16