FilterBox Wall. Automatically or manually cleaned for dust & fume applications.

Similar documents
LCP Cartridge Dust Collector

FilterMax F. Modular dust collector with integrated pre-separator

FilterMax F. Modular dust collector with integrated pre-separator

FlexPAK 800 DX. The leading extraction solution. Always the right capacity.

FilterMax DF. Modular dust multi purpose collector. Models

FilterMax DF. Modular dust multi purpose collector. Models

FilterMax F. Modular dust collector with integrated pre-separator. Models

Exhaust rail system 920 for stationary vehicles

Exhaust rail system 920 for stationary vehicles

FMKZ casette filter, EX

Extraction arm FX100 Original

NCF fans 50 Hz. Protection class IP 55

NCF fans 60Hz. Protection class IP 55

Bench Top Extraction Arms

NCF 60 Hz. Protection class IP 55

Pneumatic Rail System (PRS)

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

FilterMax DF. Modular dust multi purpose collector

About Dustcontrol Filter Units

About Vacuum Producers

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

LCP Cartridge Dust Collector

A new dimension ZPF 9H the central suction and filter unit

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2

FILTER Pure advantage. A flexible modular filter for particles and gas

LCP Cartridge Dust Collector

Improving your workspace

BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2

series 260 LAS 260 HD FK

THE INTELIAIR TM. i2m AND i3m FUME EXTRACTION ARMS KEY FEATURES

SF-1000 workbench - welding table. User s Manual.

Weld filter C10. Weld filter C20. Easy to move and position. Includes 3 m long extraction arm, Original. Cleanable filter with high filtration

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BTX-208. Fume Extraction System _B

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

DESKTOP CONTAINMENT SYSTEM

Weller Info No. 2. New in Weller Volume Extraction System WFE2ES

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

2007 /

Products that improve the working environment, reduce environmental impact and increase efficiency.

TECHNICAL SPECIFICATIONS

Fume extractor is warranted for two years, parts and labor.

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

quatroair.com AIR TECHNOLOGIES INC.

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

85 db(a) at m³/h. 75 db(a) at 4000 m³/h. 78 db(a) at 3500 m³/h. 69 db(a) at 2500 m³/h. 85 db(a) at m³/h. 74 db(a) at 4000 m³/h

Cartridge filter SDFC

NEW Slimpak EC Box Fan (SLPT EC)

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

PRODUCT GUIDE Version 2004:02 For a better workbench environment

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

Product catalogue 2010

Portable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500 CFM (2550 M3H) For 2 arm configuration

1 / Genset general description

1 / Genset general description

BULL 240 EBS INDUSTRIAL VACUUM. Operator s Manual VAC.BULL240.EBS. SASE Company, LLC 2475 Stock Creek Blvd. Rockford, TN 37853

Fume Extraction & Dust Collection

5 Compact Vacuum Systems. Compact Vacuum Systems

1 / Genset general description

The future of wet and dry vacuum cleaning

FILTER MODULES FILTER MODULES APPLICATIONS

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

FlowFAST H. Horizontal Laminar Flow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Duct filter units. Duct HEPA filter units AKF

APPENDIX A 30 WELDING BOOTHS AND FUME EXHAUST SYSTEM

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

(ULT300-UM.x-HFM050) Technical Documentation

100L. 942 mm. 335 mm 385 mm

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

Product catalogue 2010

Compact Vacuum Systems

Work area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h. Manufacturer. Production year. Model number/type. page

Airistar 100GT Owner s Manual Airistar 100GT Air Purifier

Sentinel D-Box Twin Fan

VORTICENT C E RANGE Centrifugal fans

Modular filter system for effective removal of oil mist

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

TFS 1000 EXTRACTION / FILTER / POLLUTION CONTROL // TECHNOLOGY

V. Aa. Gram A/S

Operating instructions

Novenco Tunnel Fans. Novax October 2007

Eurovacuum EVC Series

Products, systems and solutions for improved workplaces 2009/2010

RESPIRATORY CATALOG. The SR 500. PAPR family. The AirPlus. PAPR family

(ULT200-UM.x-HFM050) Technical Documentation

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

V. Aa. Gram A/S

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4

PACKAGED DOWNFLO EVOLUTION DUST COLLECTORS. The Complete Plug-and-Play Solution

Fume Extraction. 22 o C DIGITAL RANGE. 250 m 3 / hr BROCHURE

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Transcription:

Automatically or manually cleaned for dust & fume applications. FilterBox Wall can come with or without a attached. The models without a are suitable for installations with an external and contactor, and can be used with multiple FilterBox units. The unit is delivered with a wall bracket for easy installation. Depending on the model, the filter cartridge is either manually or automatically cleaned. For the manual model, there is an alarm indicating when the air flow is too low, and an operating hours meter. The model with automatic has an advanced filter control system that starts the process automatically when the air flow is too low. Additional protection from harmful particles given if a HEPA filter is installed. For dust applications, the unit is cleaned mechanically. For welding fumes it uses a combination of mechanical and compressed air. For welding applications, compressed air is required. Note! FilterBox is not for use in environments where combustible dust or gases are present, and it is not for use in filtering combustible dust or gases. User friendly and superior filter, mechanical and/or with compressed air for long filter life Automatic damper preventing dust from leaking out while Dust free filter replacement and emptying of dust bin Third party approval for welding fumes category W according to EN 2- Third pparty approval for welding fumes category W according to EN 2- Product name Noise level (db(a)) Filter efficiency (%) 99 FilterBox Wall (without ) 66 (N24 ) 74 (N27 ) Compressed air requirement DIN ISO 857-, class 5/5/4 (7 bar) Installation Material Dustbin volume (l) 5 Indoor Extraction arm diameter (mm) Airflow (m/h) 00 Filter Area (m2) Arm length (m) Filter type Number of filter elements Filter material Electric plug Casing in rotomoulded plastic Without Cartridge Polyester PW Without www.nederman.com 27-0-208

Filter method Mechanical, Compressed air www.nederman.com 2 27-0-208

FilterBox Wall Image Description Power Voltage (V) 400 20 20 20 0 20 0 200 200 575 575 20 20 400 Frequency (Hz) No of phases Weight (kg) Power (kw) Note Model 2626*,5 2646* 2656* with 268206** with 26826**,5 with 26896**,5 with 268406** 26506* 2656* 2686* 2696* 2606* 266* 266* www.nederman.com 27-0-208

Image Description Power Voltage (V) Frequency (Hz) No of phases Weight (kg) Power (kw) Note Model 4 4 2666* 2676* with N29 400 90 268486 with N24 400 90 Not with sensor clamp. 268456*** with N29 400 90 Not with sensor clamp. 268476*** with N24 400 90 268466 with N27 5 90,5 268846 with N27 20 90 2 268856 with N27 4 90 268866 with N29 20 90 268886 with N29 4 90 268896 with N29 575 90 268906 * ** with ***Not with sensor clamp. www.nederman.com 4 27-0-208

Accessory Part No Outlet with duct connection D=200mm 276749 Sensor clamp to be attached to the earth cable of the welding power source. 47299 Filter-PW-FB- 22672 Filter-PW HE-FB-5 2706 Filter PWA-FB-5 2742 HEPA filter H4 0m2 Filterbox 276756 HEPA filter H 0m2 Filterbox 27665 Bags for Filterbox dust bin, 0pcs 27668 Twin Module blue 27680 www.nederman.com 5 27-0-208

FilterBox Wall with N24 included FilterBox Wall with N29 included www.nederman.com 6 27-0-208