Street Address. City-Village-Township

Similar documents
Street Address. City-Village-Township

is attached to and becomes a part of a agreement dated, 20

is attached to and becomes a part of a agreement dated, 20,

Cancels Nineteenth Revised Sheet No. D6

RATE 725 RATE FOR ELECTRIC SERVICE METAL MELTING SERVICE

Large Power Service Time-of-Use (LPS-TOU)

THE PUBLIC SERVICE COMMISSION OF WYOMING

SECTION D RATE SCHEDULES

RATE 724 RATE FOR ELECTRIC SERVICE GENERAL SERVICE LARGE

Rate Schedules. Effective 1/1/2019

NSTAR ELECTRIC COMPANY M.D.P.U. No. 28 EASTERN MASSACHUSETTS CAMBRIDGE SERVICE AREA GENERAL SERVICE

STANDBY SERVICE. Transmission Service Primary Service Secondary Service

Indianapolis Power & Light Company I.U.R.C. No. E-18 Original No. 17 One Monument Circle Indianapolis, Indiana

M.P.S.C. No. 2 Electric Third Revised Sheet No. 65 (Rate Case) Cancels Second Revised Sheet No. 65

RATE 624 RATE FOR ELECTRIC SERVICE GENERAL SERVICE LARGE

Consolidated Edison Company of New York, Inc.

Large Power Service Time of Use

Small General Service Time-of-Use Rate Schedule GS-TOU3

NORTHEAST NEBRASKA PUBLIC POWER DISTRICT RATE SCHEDULE LP-2 Large Power Service. Effective: For bills rendered on and after February 1, 2019.

SERVICE CLASSIFICATION NO. 7. Also optional for: This option is not available to Service Classification No. 2 customers, effective December 3, 2002.

NORTHEAST NEBRASKA PUBLIC POWER DISTRICT RATE SCHEDULE LP-2 Large Power Service. Effective: For bills rendered on and after January 1, 2014.

AUSTIN UTILITIES. CHARACTER OF SERVICE: AC, 60 cycles, 120/240 Volt, three wire, single-phase; or 120 Volt, two wire.

COVER PAGE FOR THE NEW JERSEY ELECTRIC TARIFF CURRENT UPDATE This Internet update on or about: November 30, 2015

JERSEY CENTRAL POWER & LIGHT COMPANY. TARIFF for SERVICE. Part III. Service Classifications and Riders

MISSOURI SERVICE AREA

Electric Rates & Tariffs

RATE 732 RATE FOR ELECTRIC SERVICE INDUSTRIAL POWER SERVICE

JERSEY CENTRAL POWER & LIGHT COMPANY. TARIFF for SERVICE. Part III. Service Classifications and Riders

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. LARGE MANUFACTURING SERVICE RATE SCHEDULES (November 2018)

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. Availability

KCP&L GREATER MISSOURI OPERATIONS COMPANY P.S.C. MO. No. 1 1st Revised Sheet No. 149 Canceling P.S.C. MO. No. 1 Original Sheet No.

RESIDENTIAL SERVICE. CHARACTER OF SERVICE: This Schedule is for single phase, alternating current at standard voltage as designated by the Utility.

JERSEY CENTRAL POWER & LIGHT COMPANY. TARIFF for SERVICE. Part III. Service Classifications and Riders

March 13, 2000 PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA ENERGY DIVISION. Modification to Power Factor Adjustment Special Condition

THE NARRAGANSETT ELECTRIC COMPANY LARGE DEMAND RATE (G-32) RETAIL DELIVERY SERVICE

Agricultural Service Rate Schedule AG

Large General Service Time-of-Use Storage Program

COVER PAGE FOR THE NEW JERSEY ELECTRIC TARIFF

Power Supply Cost Recovery

EXHIBIT A ORDINANCE NO. O CITY OF LAURINBURG, NORTH CAROLINA SCHEDULES OPR RESIDENTIAL TIME-OF-USE SERVICE

INDEX OF RATE SCHEDULES. Schedule Classification Sheet No.

D Original Sheet No. 11!81 Revised

JERSEY CENTRAL POWER & LIGHT COMPANY. TARIFF for SERVICE. Part III. Service Classifications and Riders

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. Availability

SERVICE CLASSIFICATION NO. 7 LARGE GENERAL TIME-OF-DAY SERVICE

ORDINANCE NO. -'- THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

SALT RIVER PROJECT AGRICULTURAL IMPROVEMENT AND POWER DISTRICT E-27 CUSTOMER GENERATION PRICE PLAN FOR RESIDENTIAL SERVICE

RATE APPLICATION MANUAL. Kansas City Board of Public Utilities

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 Lihue, Kauai, Hawaii First Revised Sheet 80 Cancels Original Sheet 80

SCHEDULE 62 COGENERATION AND SMALL POWER PRODUCTION SCHEDULE - IDAHO

MISSOURI SERVICE AREA

Northeastern Rural Electric Membership Corporation Schedule DG-2 Columbia City, Indiana Page 1 of 5

TITLE PAGE ELECTRIC SERVICE NORTHERN STATES POWER COMPANY, A WISCONSIN CORPORATION, AND SUBSIDIARY OF XCEL ENERGY INC.

Panola-Harrison Electric Cooperative, Inc. Louisiana Tariff Effective: March 3, 2004

Buy All Sell All Rider for Interconnection of Renewable Generation

RATE 633 RATE FOR ELECTRIC SERVICE HIGH LOAD FACTOR INDUSTRIAL POWER SERVICE

P.S.C. No. 9 - Electricity Consolidated Edison Company First Revised Leaf No. 310 of New York, Inc. Superseding Original Leaf No.

Schedule GS-2 INTERMEDIATE GENERAL SERVICE

Page Number Schedule Rate Class Description 1 R

MISSOURI SERVICE AREA

FLORENCE ELECTRICITY DEPARTMENT. MANUFACTURING SERVICE RATE--SCHEDULE TDMSA (October 2015) Availability

M.P.S.C. No. 2 Electric Ninth Revised Sheet No. 50 (Rate Case) Cancels Eighth Revised Sheet No. 50

CITY OF SANTA CLARA. RATE OPTIONS: Non Time of Use Time of Use CUSTOMER CHARGE For Each Service Address per meter per month $ $306.

Wegmans Fairfax Joseph B. Lookup Electrical System Existing Conditions Report & Building Load Summary Report. Appendix Tech Assignment # 2

ls2288 ORDINANCE NO. _

A. Basic Customer Charge: $ B. Energy Charge: $.09316/kWh

WELLSBORO ELECTRIC COMPANY. General Tariff of. Rates, Rules and Regulations Governing. the Provision of Electric Service. The Borough of Wellsboro

STANDBY SERVICE. RULES AND REGULATIONS: Terms and conditions of this schedule and the General Rules and Regulations govern use of this schedule.

Edmond Electric Standard Pricing Schedules

ATLANTIC CITY ELECTRIC COMPANY BPU NJ No. 11 Electric Service - Section IV Forty-Third Revised Sheet Replaces Forty-Second Revised Sheet No.

SALT RIVER PROJECT AGRICULTURAL IMPROVEMENT AND POWER DISTRICT E-21 PRICE PLAN FOR RESIDENTIAL SUPER PEAK TIME-OF-USE SERVICE

National Grid. Narragansett Electric Company INVESTIGATION AS TO THE PROPRIETY OF COMPLIANCE TARIFF CHANGES. 2 nd Amended Compliance Filing

Schedule TOU-EV-9 Sheet 1 GENERAL SERVICE TIME-OF-USE, ELECTRIC VEHICLE CHARGING, LARGE DEMAND METERED

WHEREAS, LADWP seeks to enable the continued growth of customer generation, including solar-powered generation; and

CITY OF BOWLING GREEN, OHIO MUNICIPAL UTILITIES ELECTRIC RATE SCHEDULES

Within the service area of the District from lines of 115,000 volts or 34,500 volts.

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC.

Docket 50-ER-108 Algoma Utilities. Final Form Rate and Rule Tariff Sheets Amendment 78. Filed By: Public Service Commission of Wisconsin

Edmond Electric Standard Pricing Schedules

o Payment Arrangements o Discontinuing Service o Filing a complaint Electric Service Rates Public Records Policy Annual Report Annual Fuel Mix

CITY OF GRAND ISLAND UTILITIES DEPARTMENT ELECTRIC RATE SCHEDULE Effective October 1, Ordinance No. 9133

Pilot Programs. Residential Service. Effective November 1, CITY OF AUSTIN - ELECTRIC RATE SCHEDULES

FLORENCE ELECTRICITY DEPARTMENT. GENERAL POWER RATE--SCHEDULE GSC (October 2015) Availability

Schedule DP-1 SMALL GENERAL SERVICE (EXPERIMENTAL)

1065 Woodman Drive Twelfth Revised Sheet No. T8 Dayton, Ohio Page 1 of 5

Schedule GS-1 SMALL GENERAL SERVICE

KANSAS CITY POWER & LIGHT COMPANY P.S.C. MO. No. 7 Third D Original Sheet No. 19 t8l Revised

CITY OF BOWLING GREEN, OHIO MUNICIPAL UTILITIES ELECTRIC RATE SCHEDULES

SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT

CHOPTANK ELECTRIC COOPERATIVE, INC. DENTON MARYLAND TERMS AND CONDITIONS

Portland General Electric Company Fourteenth Revision of Sheet No P.U.C. Oregon No. E-18 Canceling Thirteenth Revision of Sheet No.

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

of New York, Inc. Original Leaf No. 216 SERVICE CLASSIFICATION NO. 3 BACK-UP SERVICE

Schedule GS-3 LARGE GENERAL SERVICE SECONDARY VOLTAGE I. APPLICABILITY AND AVAILABILITY

ADAMS-COLUMBIA ELECTRIC COOPERATIVE. Rates. Board Approved 1/27/16

Proposal Concerning Modifications to LIPA s Tariff for Electric Service

N.H.P.U.C. No ELECTRICITY GRANITE STATE ELECTRIC COMPANY DBA LIBERTY UTILITIES. SUPERSEDING N.H.P.U.C. No. 17 TEMPORARY RATES

Electric Rates. For Michigan customers

TELL CITY ELECTRIC DEPARTMENT RATES AND CHARGES

Distributed Generation Interconnection Policy

Transcription:

Schedule Designation D11 Primary Supply Agreement D11 963-1816 8/18 THIS AGREEMENT, dated, 20, by and between (Name) a, (Legal Entity and State of Organization) herein called the "Customer", and DTE Electric Company, a Michigan corporation, of One Energy Plaza, Detroit, Michigan 48226, hereinafter called the "Company", is for a supply of electric energy to be delivered by the Company to the Customer's premises located at: Street Address City-Village-Township The supply shall be delivered by the Company and received and paid for by the Customer under the following terms and conditions: 1.a. For new primary installations over 1,000 kw, this Agreement shall be for a period of five (5) years beginning on, 20, or whenever service is made available after that date, extending thereafter from month to month until terminated by mutual consent of the parties hereto or on twelve months written notice by either party, which may be given at any time after the end of the fourth year. b. For new primary installations of 1000 kw or less, and for new Customers at existing installations, the term is for one (1) year beginning on, 20, or whenever service is made available after that date, extending thereafter from month to month until terminated by mutual consent or on one month written notice by either party. The one-year term, under special circumstances, may be increased or reduced at the discretion of the Company. c. Where special services are required, the term will be as specified in the applicable contract rider. 2. The Company shall furnish the Customer service twenty-four hours a day subject, however, to interruption by agreement or upon advance notice or by accident or other causes not under the reasonable control of the Company. Service is also subject to interruption by implementation of the Emergency Electrical Procedures as delineated in Rule C3.

3. The Customer shall pay for the supply of electric energy delivered by the Company at the Primary Supply Rate as approved by the Michigan Public Service Commission, from time to time. The rate as of the date of this Agreement is attached. 4. Electric service that requires construction of a line extension or other facilities is subject to the provisions of Rule C6.1. 5. a. In some cases the Customer is eligible to take service under any one of two or more rates. If requested, the Company will advise the Customer in the selection of the rate, which will give it the lowest cost of service, based on the information at hand, but the responsibility for the selection of the rate lies with the Customer. b. After the Customer has selected the rate under which it elects to take service, it is not permitted to change from that rate to another until twelve months have elapsed. A Customer will not be permitted to evade this rule by the device of temporarily terminating service. c. However, the Company may, at its option, waive this rule where it appears that an earlier change is requested for permanent rather than for temporary or seasonal advantage. The intent of this rule is to prohibit frequent shifts from rate to rate. As used in this rule, the word rate shall include applicable riders. 6. The Primary Supply Rate and the Rules and Regulations applicable thereto, as set forth in the Company s Rate Schedule, are on file with and have been approved by the Michigan Public Service Commission. The Rate Schedule and the Rules and Regulations are subject to change from time to time by order issued by the Michigan Public Service Commission. 7. The supply and associated service are also governed by the Rules of Electrical Service established by the Michigan Public Service Commission and by the Company s Standard Rules and Regulations. All Rules are subject to change from time to time. 8. The Customer another source of power, and desires an initial contract capacity Has or Has Not of kilowatts, at a nominal voltage of volts. Accepted: DTE ELECTRIC COMPANY By: Authorized Signature Customer: Signature: Name: Name: Title: Title: Primary Supply Agreement D11 963-1816 P-2 8/18

RATE SCHEDULE NO. D11 AVAILABILITY OF SERVICE: Available to customers desiring service at primary, sub-transmission, or transmission voltage who contract for a specified capacity of not less than 50 kilowatts at a single location. HOURS OF SERVICE: 24 hours, subject to interruption by agreement, or by advance notice. CURRENT, PHASE AND VOLTAGE: Alternating current, three-phase, nominally at 4,800, 13,200, 24,000, 41,570 or 120,000 volts at the option of the Company. CONTRACT CAPACITY: Customers shall contract for a specified capacity in kilowatts sufficient to meet normal maximum requirements but not less than 50 kilowatts. The Company undertakes to provide the necessary facilities for a supply of electric power from its primary distribution system at the contract capacity. Any single reading of the demand meter in any month that exceeds the contract capacity then in effect shall become the new contract capacity. The contract capacity for customers served at more than one voltage level shall be the sum of the contract capacities established for each voltage level. RATE PER MONTH: Full Service Customers: Power Supply Charges: Capacity Demand Charge: $11.01 per kw of on-peak billing demand $0.81 per kw of on-peak billing demand at transmission level $0.54 per kw of on-peak billing demand at subtransmission level Non-Capacity Demand Charge: $5.99 per kw of on-peak billing demand $0.44 per kw of on-peak billing demand at transmission level $0.29 per kw of on-peak billing demand at subtransmission level Energy Charge: 4.150 per kwh for all on-peak kwh 3.150 per kwh for all off-peak kwh 0.183 per kwh at transmission level 0.108 per kwh at subtransmission level Delivery Charges: Primary Service Charge: $275 per month Subtransmission and Transmission Service Charge: $375 per month Distribution Charges: For primary service (less than 24 kv) $3.57 per kw of maximum demand. For service at subtransmission voltage (24 to 41.6 kv) $1.39 per kw of maximum demand. For service at transmission voltage (120 kv and above) $0.70 per kw of maximum demand. Substation Credit: Available to customers where service at sub-transmission voltage level (24 to 41.6 kv) or higher is required, who provide the on-site substation including all necessary transforming, controlling and protective equipment. A credit of $0.30 per kw of maximum demand shall be applied to the maximum demand charge. A credit of 0.040 per kwh shall be applied to the energy charge where the service is metered on the primary side of the transformer. Surcharges and Credits: As approved by the Commission. See Sections C8.5 and C9.8. Primary Supply Agreement D11 963-1816 P- 3 8/18

RATE SCHEDULE NO. D11 (Contd.) Retail Access Service Customers: Capacity (Only applicable to Retail Access Service Customers receiving Utility Capacity Service from DTE Electric) Demand Charge: $11.01 per kw of on-peak billing demand $0.81 per kw of on-peak billing demand at transmission level $0.54 per kw of on-peak billing demand at subtransmission level Capacity related surcharges and credits applicable to power supply, excluding PSCR, as approved by the Commission. See Section C5.8. Delivery Charges: Primary Service Charge: $275 per month Subtrassmission and Transmission Service Charge: $375 per month Distribution Charges: For primary service (less than 24 kv) $3.57 per kw of maximum demand. For service at subtransmission voltage (24 to 41.6 kv) $1.39 per kw of maximum demand. For service at transmission voltage (120 kv and above) $0.70 per kw of maximum demand. Substation Credit: Available to customers where service at sub-transmission voltage level (24 to 41.6 kv) or higher is required, who provide the on-site substation including all necessary transforming, controlling and protective equipment. A credit of $0.30 per kw of maximum demand shall be applied to the maximum demand charge. A credit of 0.040 per kwh shall be applied to the energy charge where the service is metered on the primary side of the transformer. Surcharges and Credits: As approved by the Commission. See Section C9.8. LATE PAYMENT CHARGE: See Section C4.8. DEFINITION OF CUSTOMER VOLTAGE LEVEL: See Section C13. MONTHLY ON-PEAK BILLING DEMAND: The monthly on-peak billing demand shall be the single highest 30-minute integrated reading of the demand meter during the on-peak hours of the billing period. The monthly on- peak billing demand will not be less than 65% of the highest monthly on-peak metered billing demand during the billing months of June, July, August, September, and October of the preceding eleven billing months, nor less than 50 kilowatts. MAXIMUM DEMAND: The maximum demand shall be the highest 30-minute demand created during the previous 12 billing months, including the current month but not less than 50% of contract capacity. This clause is applicable to each voltage level served. MINIMUM CHARGE: All applicable demand charges plus the service charge and any applicable per meter per month surcharges. Primary Supply Agreement D11 963-1816 P- 4 8/18

RATE SCHEDULE NO. D11 (Contd.) SCHEDULE OF ON-PEAK HOURS: See Section C11. POWER FACTOR CLAUSE: Full Service Customers: The rates and charges under this tariff are based on the customer maintaining a power factor of not less than 85% lagging. Any power factor less than 70% will not be permitted and the customer will be required to install at his own expense such corrective equipment as may be necessary to improve power factor. A penalty will be applied to the total amount of the monthly billing for electric energy for power factor below 85% lagging in accordance with the table in Power Factor Determination, Section C12. The Power Factor Clause shall not be applied to the on-peak billing demand ratchet nor to the minimum contract demand, but will be applied to metered quantities. Retail Access Service Customers: A power factor of less than 70% is not permitted and necessary corrective equipment must be installed by the Customer to correct to a minimum level of 70%. Power factor and excess Reactive Demand charges will be calculated at each Customer location at the time of the Location s single highest 30-minute integrated kw reading of the Interval Demand Meter during the on-peak hours of the billing period, which are those hours from 7 a.m. until 11 p.m. consistent with the ITC Open Access Transmission Tariff. Excess Reactive Demand is any Reactive Demand resulting from operations below 80% power factor. A monthly charge of $3.50/kVAR will be applied to excess Reactive Demand. SPECIAL TERMS AND CONDITIONS: The contract capacity however established shall not be decreased during the term of the contract and subsequent renewal periods as long as service is required unless there is a specific reduction in connected load. Customer-owned equipment must be operated so that voltage fluctuations on the primary distribution system of the Company shall not exceed permissible limits. Customers will be permitted to transfer from this rate to a secondary commercial rate, provided they can meet the availability requirements, if the load characteristic changes sufficiently so that the customer would benefit by the change for the foreseeable future even though metering was continued at primary voltage. Frequent changes, however, from one rate to another for a period less than one full year will not be permitted in accordance with Section C4.4 - Choice of Rates. For example, during the period that a building is under construction, primary service may be supplied and metered at primary voltage and billed on a secondary rate while the building is under the jurisdiction of the contractor. Also, for the convenience of the utility, service to a large school complex or a high rise building where, as a matter of design, primary voltage is furnished with Company owned transformers at remote locations fed by customer owned primary cables, the account can be billed on a secondary rate though metered at one central primary voltage location at or near the termination of the utility-owned cables. At the option of the Company, service may be supplied at the primary voltage and metered at a secondary voltage when the customer transfers from a secondary rate. For loads metered at a secondary voltage (less than 600V), all measured quantities shall be increased by 2%. CONTRACT TERM: For new primary installations over 1000 kw the term is for not less than five years, extending thereafter from month-to-month until terminated by mutual consent or on twelve months' written notice by either party, which may be given at any time after the end of the fourth year. For new primary installations of 1000 kw or less and for new customers at existing installations, the term is for one year which under special circumstances may be increased or reduced at the discretion of the Company, extending thereafter from month-to-month until terminated by mutual consent or on one month written notice by either party. Where special services are required, the term will be as specified in the applicable contract rider. Primary Supply Agreement D11 963-1816 P- 5 8/18