In Situ Oxygen Transmitter For High Sulfur Environments

Similar documents
In Situ Oxygen Transmitter

In Situ Oxygen Transmitter

In Situ Oxygen Transmitter

In Situ Oxygen Transmitter

In Situ Oxygen Transmitter

In Situ Oxygen Transmitter for Hazardous Area Applications

Zirconia Oxygen Probe

World Class 3000 Oxygen Analyzer with IFT 3000 Intelligent Field Transmitter

SPS 4000 Single Probe Autocalibration Sequencer

ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

OCX 8800 Oxygen/Combustibles Transmitter

OCX 4400 OXYGEN/COMBUSTIBLES TRANSMITTER

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

World Class 3000 Oxygen Analyzer with HPS Heater Power Supply Field Module (for use with Existing Signal Conditioning Electronics)

Installation/Start-up Manual CMB_MAN_ABR_CH88 September CH88 In-Situ Combustion O2. Analyzer System

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter

Combustion Gas Analysis

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter

ISTEC MAGNETIC METERS

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter

OCX 8800 Oxygen/Combustibles Transmitter

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Electromagnetic Flowmeters. Product Overview.

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

Fisher 546 Electro Pneumatic Transducer

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

FEATURES AND BENEFITS

better analysis counts

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Model Q45H/ Residual Chlorine Monitor...

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

TURBINE FLOW METER SELECTION GUIDE

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

Point level measurement Capacitance switches

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

Micro Motion F-Series Coriolis Flow and Density Meters

Fan/Damper Actuators with Optional FoundationTM fieldbus Communications

O 2 CO CO 2 NO NO 2 NO x

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

Micro Motion 7827 Digital Viscosity Meter

Micro Motion ELITE Mass Flow and Density Meters

Endura AZ20 oxygen monitor Combustion gas analysis. Superior technology and quality from the world leader in oxygen measurement

Combustion Control Problem Solution Combustion Process

Rosemount 3051CFA Annubar Flowmeter

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors.

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Dissolved Oxygen Measurement System with Air Blast Cleaner

F-1500 SERIES INSERTION TURBINE FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

Rosemount 1075 and 1099 Series High Temperature Thermocouples

1070 SERIES ULTRA LOW NO X

Low Profile Insertion Vortex

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

G2 Industrial Grade Meters

Monitoring Air Emissions on Ships. Restricted Siemens AG 2014 All rights reserved.

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

COUNTER CLOCKWISE FOR CLARITY (SEE MANUAL FOR SPECIFIC WATER & DUST TIGHT AP LOCAL ELEMENT ENCLOSURE ROTA FLAT PARALLEL TO FLOW.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Rosemount 8750WB Magnetic Flowmeter System

FUEL OIL BURNERS. By Mark Butterfield March 09

SERVOTOUGH Fluegas Exact (2700)

Fisher 3660 and 3661 Positioners

Now available with MVD Technology! ELITE Mass Flow and Density Meters

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

MARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD

ELECTRAULIC ACTUATORS & DRIVES

THC Heated FID 3-300A

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Dissolved Oxygen, ph, and Conductivity

General Purpose Toroidal Conductivity Sensors

F-2700 SERIES INSERTION VORTEX FLOW METER

Flash Point Process Analyzer

Pasve Rotary Retraction Valve

DREXELBROOK. Universal IV CM Model 2-Wire, 4-20 ma, Water Cut Monitor. Applications. Durability. Eliminate Routine Maintenance.

Signet 2551 Magmeter Flow Sensor

Transmitting Transducer. Gas/Air Velocity Range:

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

TECHNICAL BULLETIN. Logix 520MD Series Digital Positioner. Experience In Motion FCD LGENTB /09

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

Transcription:

Product Data Sheet PDS 106-340AS.A01 Sulfur Resistant Oxymitter March, 2000 In Situ Oxygen Transmitter For High Sulfur Environments Zirconium oxide-based cell is resistant to sulfur in the flue gas Unique architecture - Electronics mounted in the probe head Outstanding accuracy - resolution and sensitivity increased by 400% Simplified installation no electronics box, probe cable or conduit intelligent power supply provides automatic line voltage selection Advanced sensor diagnostics alarm indicates when calibration is recommended Robust, highly integrated electronics consumes 95% less power surface mount technology improves reliability and vibration resistance CENELEC hazardous area and general purpose models Digital HART communications AMS/PlantWeb compatible Fully field repairable THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS IN HIGH SULFUR ENVIRONMENTS Introducing the Sulfur Resistant Oxymitter Oxygen Transmitter, the world s ONLY in situ, zirconium oxidebased oxygen transmitter for flue gas measurement that can last significantly longer in sulfur-rich environments. These oxygen measurements can be used in a control system or by a boiler operator to fine tune burner fuel/air ratios for maximum efficiency. The Sulfur Resistant Oxymitter is ideal for recovery boilers, process heaters and spent acid furnaces. Combustion applications with high sulfur contents in the flue gases cause many problems for oxygen analyzers, the worst of which is the deterioration of the zirconium oxide cell used to measure the excess oxygen in the combustion process. This zirconium oxide cell typically uses platinum as an electrode material to conduct the signal to its electronics. In this environment, the sulfur reacts with the platinum within the zirconium oxide cell to create platinum sulfide, quickly rendering the cell useless. The environment is especially damaging to the zirconium oxide cell when oxygen levels are low and sulfur levels are high. Historically, zirconium oxide cells have survived only several weeks in such conditions. Now, there is a solution to the problem. Applications where these environments are typically found include recovery boilers in pulp and paper mills, industrial boilers and municipal utilities burning high sulfur coal or heavy fuel oil, process heaters and furnaces that use waste gases that contain large amounts of sulfur, and spent acid furnaces. Using a revolutionary and patented cell design, Rosemount Analytical can offer a zirconium oxide-based, in situ oxygen analyzer that can withstand the attack of sulfur in the flue gas. These new zirconium oxide cells still deliver the same stable, reliable oxygen measurement that you get from the standard Oxymitter, but last ten times longer in these harsh environments. Also, these cells will still offer Rosemount Analytical s patented calibration recommended feature that alerts you when the instrument should be calibrated. Visit our website at www.processanalytic.com On-line Ordering Available.

THE SULFUR RESISTANT OXYMITTER OXYGEN TRANSMITTER IS COMPLETELY FIELD REPAIRABLE Sensor Cell Assembly Heater/Thermocouple Assembly Plug-in Electronics Module SULFUR RESISTANT OXYMITTER FEATURES AND BENEFITS Features Revolutionary and patented cell design lasts ten times longer, in high sulfur environments, than traditional oxygen analyzers. Rapid, accurate (typically ±0.75 percent), and reliable measurement of excess oxygen with a single, in situ transmitter. Integrated oxygen probe and electronics simplifies installation. In situ design. No sample system, sample probes, scrubbers, or pumps are necessary; test gas calibration check without disturbing the probe. Calibration recommended indication. On-line electrical CAL check indicates need for calibration with gas standard. Field replaceable cell and heater/thermocouple assembly and plug-in electronics module. Suitable for use in process temperatures up to 1300 F (700 C). Optionally up to 2400 F (1300 C). Material of construction 316 LSS (all wetted parts) Automatic line voltage selections. Benefits Lowers maintenance costs and optimizes plant operations. Provides inputs for significant fuel savings which normally pay for the analyzer in less than one year; best accuracy specifications in the industry! Eliminates costs of mounting separate electronics. Eliminates cabling and conduit between probe and electronics. Low installation and low maintenance costs. Optimizes plant resources; reduces maintenance and calibration costs. Ease of maintenance. Suitable for use in most combustion applications. High resistance to corrosion. Automatically selects from 90 to 250 VAC and 50/60 Hz without configuration or setup. Communicate with the Sulfur Resistant Oxymitter from almost anywhere via the HART Protocol Page 2

SPECIFICATIONS! SULFUR RESISTANT OXYMITTER Net O 2 Range 0-40% selectable via HART Accuracy: typically ±0.75% of reading or 0.05% O 2, whichever is greater Lowest detectable limit -.05% 0 2 System Response to Test Gas: Initial response in less than 3 seconds T90 in less than 8 seconds Temperature Limits: Process: Electronics: 32 to 1300 F (0 to 704 C) up to 2400 F (1300 C) with optional accessories -40 to 185 F (-40 to 85 C) Operating temperature of electronics inside of instrument housing, as measured via Rosemount Asset Management Solutions software. Probe Lengths, Nominal and Approximate Shipping Weights: 18 in. (457 mm) package: 16 pounds (7.3 kg) 3 foot (0.91 m) package: 21 pounds (9.5 kg) 6 foot (1.83 m) package: 27 pounds (12.2 kg) 9 foot (2.74 m) package: 33 pounds (15.0 kg) 12 foot (3.66 m) package: 39 pounds (17.7 kg) Mounting and Mounting Position: Vertical or Horizontal Materials: Probe: Electronics Enclosure: Calibration: Spool pieces are available to offset transmitter housing from ambient temperatures above 149 F(65 C) Wetted or welded parts - 316L stainless steel Non-wetted parts - 304 stainless steel, low-copper aluminum Low-copper aluminum Semi-automatic or automatic Calibration Gas Mixtures Recommended: 0.4% O 2, Balance N 2 8% O 2, Balance N 2 (Ref. test gas kit #6296A27G01) Calibration Gas Flow: 5 scfh (2.5 l/m) Reference Air : 2 scfh (1 l/m), clean, dry, (optional) instrument-quality air (20.95% O 2 ), regulated to 5 psi (34 kpa) Electronics: Electrical Noise: Hazardous Area Certifications: (OXT 400 Version only) Line Voltage: I/O Signals: Power Consumption Limits: Power Consumption of Probe Heater: Power Consumption of Electronics: NEMA 4X, IP66 with fitting and pipe on reference exhaust port to clean dry atmosphere Meets EN 50082-2 Electromagnetic Compatibility Generic Immunity Std., Part II Includes ENG 1000 4-R for Electrostatic Discharge 4 Kv contact, 8 Kv in air Optionally ENG 1000 4-R Namur- Increased 8 Kv contact, 16 Kv in air Includes IEC 801-4 fast transients-2 Kv on power supply and control lines Class I, Div. 1, Groups C and D, CENELEC EExd II B+H2T2/T6 Universal 90 to 250 VAC, 48 to 62 Hz. No switches or jumpers required 3/4-14 NPT conduit port One 4-20mAdc, 950 ohm max Isolated with HART capability One logic I/O contact I/O is configurable as either an alarm output or as a bi-directional calibration handshake signal to intelligent multiprobe calibration gas sequencer. 5V, Self-powered, 5 ma maximum output 3/4-14 NPT conduit port 175 W nominal max 10 W nominal max Fisher-Rosemount has satisfied all obligations coming from the European legislation to harmonize the product requirements in Europe. The Oxymitter s field electronics mount directly to the oxygen probe in a standard NEMA 4X, IP66 housing.!all static performance characteristics are with operating variables constant. Specifications subject to change without notice. Page 3

ORDERING INFORMATION General Purpose Sulfur Resistant Oxymitter for Hazardous Area or FOUNDATION Fieldbus Models, Consult Your Local Rosemount Analytical Sales Person or the Factory OXT4AS Sulfur Resistant Oxymitter 4000 In Situ Oxygen Transmitter Oxymitter Transmitter - Instruction Book Code Sensing Probe Type 1 Ceramic Diffusion Element Probe (ANSI) (N. American Std.) 2 Flame Arrestor Probe (ANSI) CSA approved package (N. American Std.) 3 Snubber Diffusion Element (ANSI) (N. American Std.) 4 Ceramic Diffusion Element Probe (DIN) (European Std.) 5 Flame Arrestor Probe (DIN) - CSA approved package (snubber diffusion element) (European Std.) 6 Snubber Diffusion Element (DIN) (European Std.) 7 Ceramic Diffusion Element Probe (JIS) (Japanese Std.) 8 Flame Arrestor Probe (JIS) - CSA approved package (ceramic diffusion element) (Japanese Std.) 9 Snubber Diffusion Element (JIS) (Japanese Std.) Code Probe Assembly 0 18 (457 mm) Probe 1 18 (457 mm) Probe with Abrasive Shield (1) 2 3 (0.91m) Probe 3 3 (0.91m) Probe with Abrasive Shield (1) 4 6 (1.83m) Probe 5 6 (1.83m) Probe with Abrasive Shield (1) 6 9 (2.74 m) Probe 7 9 (2.74 m) Probe with Abrasive Shield (1) 8 12 (3.66 m) Probe (1) 9 12 (3.66 m) Probe with Abrasive Shield (1) Code Mounting Hardware - Stack Side 0 No Mounting Hardware ( 0 must be chosen under Mounting Hardware - Probe Side below) 1 New Installation - Square weld plate with studs 2 Mounting to Model 218 Mounting Plate (with Model 218 Shield Removed) 3 Mounting to Existing Model 218 Support Shield 4 Competitor s Mounting (2) 5 Mounting to Model 132 Adaptor Plate Code Mounting Hardware - Probe Side 0 No Adaptor Plate/No Mounting Hardware 1 Probe Only (ANSI) (N. American Std.) 2 New Bypass or Abrasive Shield (ANSI) (N. American Std.) 4 Probe Only (DIN) (European Std.) 5 New Bypass or Abrasive Shield (DIN) (European Std.) 7 Probe Only (JIS) (Japanese Std.) 8 New Bypass or Abrasive Shield (JIS) (Japanese Std.) OXT4AS 3 2 1 1 (Continued) EXAMPLE Page 4

(Cont d) Code Electronic Housing - NEMA 4X, IP66 11 Standard Filtered Termination 12 Transient Protected Filtered Termination Code Operator Interface (3) 1 Membrane Keypad HART Capable Code Language 1 English 2 German 3 French 4 Spanish 5 Italian Code Termination Filtering 00 No Option Specified as part of Electronic Housing Code Calibration Accessories 00 No Hardware 01 Cal. Gas Rotometer & Ref. Gas Set 02 Intelligent Multiprobe Sequencer Refer to Table 2 xx Single Probe Sequencer, mounted to Oxymitter Refer to Table 1 (Cont d) 11 1 1 00 01 NOTES: (1) Recommended usages: High velocity particulates in flue stream, installation within 3.5m (10 ft.) of soot blowers or heavy salt cake build up. Applications: Pulverized coal, recovery boilers, lime kiln. Regardless of application, abrasive shields with support brackets are recommended for 9 (2.74 m) and 12 (3.66 m) probe installations, particularly horizontal installations. (2) Where possible specify SPS number, otherwise provide details of the existing mounting plate as follows: Plate with studs Plate without studs Bolt circle diameter, number and arrangement of studs, stud thread, stud height above mounting plate Bolt circle diameter, number and arrangement of holes, thread, depth of stud mounting plate with accessories (3) Startup, calibration and operation can be implemented using the standard membrane keypad. Remote access and additional functionality available via Hart Communications (Model 275 Handheld Communicator, or AMS with Oxymitter device descriptor (DD) required.) TABLE 1 INSERT THE CODE BELOW IN THE ORDERING MATRIX. Ref. Air Set Fittings/Tubing Oxymitter Mounting Code No Yes Brass/Teflon St. Steel Horizontal Vertical 03 X X X 04 X X X 05 X X X 06 X X X 07 X X X 08 X X X 09 X X X 10 X X X Page 5

TABLE 2 LIST PART NUMBERS AS SEPARATE LINE ITEMS: The Intelligent Multiprobe Sequencer (IMPS) will automatically calibrate up to 4 probes. Part Number 3D39695G01 3D39695G02 3D39695G03 3D39695G04 3D39695G05 3D39695G06 3D39695G07 3D39695G08 3D39695G09 3D39695G10 3D39695G11 3D39695G12 Description Intelligent Multiprobe Sequencer (IMPS) Intelligent Multiprobe Sequencer (IMPS) Intelligent Multiprobe Sequencer (IMPS) Intelligent Multip[obe Sequencer (IMPS) Rosemount Analytical no longer offers integral Z-Purge option for its oxygen (O2) analyzers. However, the IFT, MPS and IMPS enclosures are still capable of Z or X purge by the customer. CALIBRATION GAS BOTTLES (1) Part Number Description Units 1A99119G01 Two disposable calibration gas bottles 4% and 8% Consult spare Parts List 100-005A UOM O 2 balance nitrogen 550 liters each, with bottle rack 1A99119G02 Two Pressure regulators for cal. gas bottles Consult Spare Parts List 100-005A UOM 1A99119G03 Gas Bottle Rack Consult Spare Parts List 100-005A UOM (1) (2) Bottles cannot be shipped via airfreight. When used with calibration recommended feature, bottles should provide 2 to 3 years of calibrations in normal service. SPOOL PIECE OPTIONS Part Number Description Units 3D39761G01 8 spool piece - probe mounts 8 back from duct wall Consult spare Parts List 100-005A UOM 3D39761G02 12 spool piece - probe mounts 12 back from duct wall Consult Spare Parts List 100-005A UOM The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. Rosemount Analytical Inc. Process Analytic Division 1201 North Main Street P.O. Box 901 Orrville, OH 44667-0901 USA Phone 330-682-9010 Toll Free in US and Canada 1-800-433-6076 Fax 330-684-4434 e-mail: GAS.CSC@frco.com Rosemount Analytical Inc., 2000. All rights reserved. Printed in U.S.A. on recycled paper.