MANUAL PALLET VALVE # Manifold Mount Outlet Port # /16-20 UNF SAE-4 Outlet Port # /4 NPT Outlet Port Max. Capacity: 5,000 PSI

Similar documents
TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Collision Repair Set. Form No No. 1517A 4-Ton Set. No. 1519A 10-Ton Set. Parts List & Operating Instructions for: 1519A. Part No. Item No.

Rear Suspension Bushing Remover/Installer

Hydraulic Hub Grappler Kit

Air / Hydraulic Pump

IN-LINE HYDRAULIC FLOW TESTER

Operating instructions Form no safety definitions

Air / Hydraulic Pump Instructions. CAUTION: Read and Understand These Operating, Servicing, and Safety Instructions, Before Using This Machine.

WCI-20 Power-Pak Coldwork Hydraulic Power Supply Rev B

OPERATOR S MANUAL Model 60010

Explanation of Safety Signal Words

Operating, Servicing, and Safety Manual Model # Hydraulic Bender

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

Instruction Manual. Maximum Operating Pressure 700 bar

KLW4000D Multi-Port Power Pack

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL F AIR HYDRAULIC PUMP

FTMP-8 AND FTMP-12 Midget Puller Units

MODEL B HYDRAULIC PUMP

QS-2200A ELECTRIC/HYDRAULIC LUBRICATION UNIT OPERATING MANUAL CONTENTS:

Operating, Servicing, and Safety Manual Model # Hydraulic Bender

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800)

ELECTRIC HYDRAULIC PUMP

MODEL 890 / 892 POWER POST 10 TON CAPACITY

Porta-Punch Manual

MODEL 25-OM-10-C & 25-OA-10-C HYDRAULIC BOOSTER

MODEL B FLANGE SPREADER. Max. Pressure: 10,000 PSI (700 BAR) Unit Weight: 18 LBS. (8.16 Kg)

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

Manifold w/ Needle Valve Instruction Manual

Gauge Adapter Instruction Manual

Clevis Plunger & Base Instruction Manual

FT-20 Portable PowerPak

MODEL B ELECTRIC HYDRAULIC PUMP

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800)

Instruction Manual. Double Acting Hydraulic, Hollow Piston Cylinders RHD Series. Maximum Operating Pressure 700 bar

Instruction Manual. Single Acting Hydraulic Aluminium Pull Cylinders RAP Series. Maximum Operating Pressure 700 bar

MODEL B ELECTRIC HYDRAULIC PUMP TOP VIEW

Instruction Manual. Maximum Operating Pressure 510 bar

MODEL F AIR HYDRAULIC PUMP

Form No , 9 5, 6. Parts List for: X1A1 AIR DRIVEN WITH REMOTE CONTROL HYDRAULIC PUMP. Max. Capacity: 10,000 PSI

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL C ELECTRIC HYDRAULIC PUMP

IN-LINE HYDRAULIC FLOW TESTER

Stub Tugger. Operating and Maintenance Instructions

Operating Instructions for: PE10 Series. Electric-Powered 10 Series Hydraulic Pump SPX

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800)

Instruction Manual. Single Acting, Pancake, Locking Collar Hydraulic Cylinders RPLC Series. Maximum Operating Pressure 700 bar

PE39 Series Compact Torque Wrench Pump

Instruction Manual. Single Acting, High Tonnage, Low Height Cylinders RSH Series. Maximum Operating Pressure 700 bar

SERIES OPERATION AND MAINTENANCE MANUAL

HYDRAULIC PUMP BATTERY POWERED. Operating Instructions for: SPX Hydraulic Technologies th Street Rockford, IL USA powerteam.

Click Here for Printable PDF File. CHAPTER 3 - BASIC INFORMATION for PERFORMING HYDRAULIC SYSTEM MAINTENANCE

User Manual for: PE8 Series PE17 Series. Electric-Powered 8 & 17 Series Two-Stage Hydraulic Pump SPX

Hydraulic Knockout Sets

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800)

FUEL KITS P/N & 526-2

Super Tube Tugger. Operating and Maintenance Instructions

Little Brute Puller Unit

60-TON-S/D HYDRAULIC

Medium Brute Hydraulic Offset Puller Unit

ELECTRIC HYDRAULIC PUMP Max. Capacity: 10,000 PSI

HYDRAULIC SPREADER. Max. Pressure: 10,000 PSI (700 BAR) Unit Weight: HS2000 = 4.8 LBS. (2.17 Kg) HS3000 = 22 LBS. (9.98 Kg)

FUEL KITS P/N & 526-4

Operation and Maintenance Manual for BS and BH Hydraulic Torque Wrenches

Instruction Manual. 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424. Maximum Operating Pressure 700 bar

Flexfence Tension Unit. with Hand Pump. Product Manual. Release 02/16.

VALVE ASSEMBLY. Form No "A" "A" Parts List for: (1/4 N.P.T.F.-REF.) (1/4 N.P.T.F.-REF.)

High Lift Transmission Jack

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

Full View Sight Flow Indicators

User Manual for: PE30 Series. Electric-Powered 30 Series Hydraulic Pump SPX

1/2" AIR DRIVEN DIAPHRAGM PUMP

Gas Engine Pumps Instruction Manual

Form No Parts List for: RWP55 RWP55-4 MODEL C HYDRAULIC PUMP AIR DRIVEN WITH REMOTE CONTROL GENERAL ASS'Y SIDE VIEW SECTION A-A

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

GHG14 DD15 Asymmetrical Turbocharger May Removal of the GHG14 DD15 Asymmetrical Turbocharger

Instruction Manual. Single Acting, Aluminium, Locking Collar Hydraulic Cylinders ARSLC Series. Maximum Operating Pressure 700 bar

38568, 43177, and Long-Reach Chain Saws

Hydraulic Gear Puller Instruction Manual

MODEL D ELECTRIC TWO-STAGE HYDRAULIC PUMP

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

OPERATION MANUAL FOR SQUARE DRIVE & LOW PROFILE HYDRAULIC TORQUE WRENCHES NOTICE WARNING

PE 20 SERIES ELECTRIC POWER PUMPS

Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions

BMK-12. Dual-Gard By-Pass Filter Mounting Kit Installation and Servicing Instructions

Operating Manual & Safety Instructions ProTorc Hydraulic Torque Wrench Model # PTLC - Please read in full before operating ProTorc Torque Wrench -

Installation For Service Only

Medium Brute Puller Unit

Binks MODELS & AGITATOR DRIVE UNITS

H Low Torque Impact Wrench

Hand Pump Instruction Manual

ELECTRIC HYDRAULIC PUMP

Air / Hydraulic Floor Service Jack

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

Form No , 3, 4. Parts List for: MODEL F AIR HYDRAULIC PUMP. Maximum Capacity: 10,000 PSI. Item Part No. No. No.

Instruction Sheet 1 1/8 HP TITAN PUMPS SAFETY FIRST

Short Rams. Operating Instructions & Parts Manual. Model Number B65141 B Capacity 2 Ton 10 Ton

Rams. Operating Instructions & Parts Manual. Model Number B65142 B65150 B65442 B65444 B65452 B Capacity 4 Ton 4 Ton 10 Ton 10 Ton 10 Ton 25 Ton

International Sales: (507) Fax: (507) Internet Address:

Form No , 3, 4 5. Parts List for: MODEL F AIR HYDRAULIC PUMP. Maximum Capacity: 10,000 PSI. Item Part No. No. No.

GT-200 GATE VALVES PN16, Screwed end

Transcription:

Form No. 102963 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.hytec.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Operating Instructions for: 110051 110052 MANUAL PALLET VALVE # - Manifold Mount Outlet Port #110051-7/16-20 UNF SAE-4 Outlet Port #110052-1/4 NPT Outlet Port Max. Capacity: 5,000 PSI Read and carefully follow the operating instructions before installation and use of this valve. Most problems with new equipment are caused by improper operation or installation. Note: Inspect the valve upon arrival. The carrier, not the manufacturer, is responsible for any damage resulting from shipment. SAFETY PRECAUTIONS WARNING: To help prevent personal injury, Before operating the pump, all hose connections must be tightened with the proper tools. Do not overtighten. Connections should only be tightened securely and leak-free. Overtightening the connections can cause premature thread failure or high pressure fittings to split at pressures lower than their rated capacities, possibly resulting in personal injury. Should a hydraulic hose ever rupture, burst, or need to be disconnected, immediately shift the control valve twice to release all pressure. Never attempt to grasp a leaking pressurized hose with your hands. The force of the escaping hydraulic fluid could cause serious injury. Do not subject the hose to potential hazard such as fire, sharp surfaces, heavy impact, or extreme heat or cold. Do not allow the hose to kink, twist, curl or bend so tightly that the oil flow within the hose is blocked or reduced. Periodically inspect the hose for wear, because any of these conditions can damage the hose and result in personal injury. Do not use the hose to move attached equipment. Stress can damage the hose and cause personal injury. Hose material and coupler seals must be compatible with the hydraulic fluid used. Hoses also must not come in contact with corrosive material such as creosote-impregnated objects and some paints. Consult the manufacturer before painting the hose(s). Never paint the couplers! Hose deterioration due to corrosive materials can result in personal injury. Do not exceed maximum pressure rating. Sheet No. 1 of 3 Litho in USA

Operating Instructions, Form No. 102963, Back sheet 1 of 3 MOUNTING THE PALLET VALVE There are two holes for 1/4" diameter bolts. See Figure 1 for dimensions. This valve can be mounted easily in any position, horizontal or vertical., 110051, & 110052 K H D C J 110051 & 110052 B B G F A E A F E Dimensions (In Inches) Cat. A B C D E F G No. Outlet Port 5.868 Manifold Mount 110051 7 5.000 3.083 3.700 1.500.500 ¼16-20 UNF 5.680 110052 1 ¼4 NPT H J K L M N P R S T Dia..312.270.545 2.595.960.485.500 5.191.564.505.503 1 ¼4-20 UNC Figure 1 Hydraulic Schematic

Operating Instructions Form No. 102963 CLAMPING AND UNCLAMPING PROCEDURE Clamping: 1. Connect hydraulic hose from power source to pallet valve using push-to-connect coupling. 2. Load work pieces. 3. Cycle the pump as described in the operating instructions for the pump. 4. When valve gauge reads clamping pressure and pump pressure has been released, disconnect hydraulic hose. Unclamping 1. Connect hydraulic hose with push-to-connect coupling. 2. Pull handle on valve to open or release oil in fixture. 3. Remove work pieces. SERVICE INTERVAL These valves are assembled with filters on both the inlet and the outlet designed to protect the valve from contaminants so small that they are not visible to the human eye. Do not assume the filters are clean and unrestricted of no contaminates are visible. The filter elements and filter disc should be replaced every 50,000 pressure cycles regardless of visual filter condition. More frequent replacement may be necessary depending of the overall cleanliness of your system. Remember, contaminant too small to be seen can be collecting in the filters and degrade system performance. The filters should be replaced before system performance changes are evident. VISUAL INSPECTION OF THE FILTERS Visual inspection of the filter elements (with intention of not replacing them) can be accomplished by following steps #1 and #2 of the section "Replacement of Filters" below. At this point, the filters can be examined without removing them from the check valve block. IMPORTANT: Attempting to remove these delicate filters will damage them causing replacement a necessity! Keep in mind that these filters are designed to remove contaminant so small that they are not visible to the human eye. Plan to replace the filters at the service intervals recommended in the following section. IMPORTANT: Never attempt to clean the filters while still assembled in the valve body or after disassembly! REPLACEMENT OF FILTERS (Refer to Parts List #101943) IMPORTANT: Extreme care must be used when disassembling valve to NOT contaminate the body and valve cartridge! 1. Remove all plumbing as necessary, and remove the screws from the filter mounting block. 2. Separate the check filter blocks from the valve body. Use care not to lose the support discs that may tend to stay in the filter block. Retain those support discs for reassembly. 3. Remove and discard the o-rings and filter elements (an o-ring pick may be needed). Also remove but retain the support discs found after the removal of the filter elements. 4. Clean the support discs with a filtered solvent or clean water. IMPORTANT: Do not attempt to clean the filter elements or the filter disc! Always replace them with new filters. 5. Reassemble the valve with new o-rings, filter elements, retaining ring, and filter disc. The support discs must be installed with the screen side facing the filter element. Orientation of the new filter elements and filter disc is not critical. 6. Reassemble the filter blocks to the valve. Sheet No. 2 of 3

= Operating Instructions, Form No. 102963, Back sheet 2 of 3 INSTALLATION DIAGRAM FOR 5.191.960.564 2.595 20 BLEND 125 125.500.503 DIA..002 M.050.070.485.505 SEE SECTION VIEW 1/4-20 UNC.015 M NOTE: TORQUE 1/4-20UNC MOUNTING BOLTS (NOT INCLUDED) TO 125/175 IN. LBS. (2 PLACES) CUSTOMER OPTION.015 R. MAX.312 DIA. MAX. INSTALLATION DIAGRAM FOR 110051 AND 110052 2.595.960 1/4-20 UNC.015 M NOTE TORQUE /4-20UNC MOUNTING BOLTS (NOT NCLUDED) TO 125/175 IN LBS. (2 PLACES)

Operating Instructions Form No. 102963 USE OF AN ACCUMULATOR (not included) For proper operation of this system, the pallet valve should be used with an accumulator. Power Team suggests using a Hytec accumulator which maintains pressure as the temperature changes or minor leaks occur. See Figure 2 for a typical application using the standard pallet valve and accumulator. See Figure 3 for a typical application using the manifold mount pallet valve and accumulator. Sheet No. 3 of 3