Data Sheet SS/AMAS/E Issue 3 Battery-Powered Flow Transmitter AquaMaster Explorer Widest flow range, highest accuracy measures minimal night and peak day flows Optional integral multi-speed, multichannel, dual-variable logger high precision, high resolution datalogging Sealed for life transmitter all input/outputs via external IP8 plug-and-socket connections Battery operation via external battery pack typically -year life which can be extended even further no power supply required, facilitates installation in remote locations Logged data transmitted via SMS text message facilitates automated handling of logged data from a network of flow meters Automated reporting using SMS text messaging via internal GSM mobile phone Scanreader encoder output fitted as standard (not available on logging versions) Backward-compatible comprehensive range of adaptors for connection to existing AquaMaster sensors AquaMaster Battery-Powered Transmitter combining long battery life with submersibility and easy interconnection as standard
Transmitter Comprehensive display Sealed for life - submersible for use in flooded chambers IP8 (NEMA) Resettable or secure totals 8mm high displays for totals (exceeds ISO 44 requirements) Total security: Two user-security levels All connections via Plug & Socket Three outputs (forward & reverse pulse, or pulses & direction and alarm) The AquaMaster Explorer is a new design of battery-powered transmitter for the AquaMaster range of flowmeters. It has a stainless steel housing with a thermoplastic outer and the assembly is sealed-for-life to IP8 as standard. The unit incorporates plug & socket connections for all inputs and outputs. In addition it derives its power from a similarly-sealed external battery pack which provides an extended battery life of typically years, which can be further extended at the cost of a slight deterioration in system performance. The transmitter can be mounted directly onto the AquaMaster sensor or remotely from it. This new design continues to provide the water industry with the most comprehensive range of flow data and information currently available. If all the data is not required, the unit can be configured so that only the required values are displayed, thus ensuring simple reading with no superfluous data. For integrally-mounted units, a new mounting system positions the display such that it is visible from both the top and the side. The AquaMaster s program memory or firmware uses reprogrammable Flash memory technology which has been enhanced to allow this firmware to be upgraded in the field (integral data logger versions only), via a local serial port connection or via GSM, if fitted. This future-proofs AquaMaster, making enhancements or new features available to installed units. Remote Access via Mobile Phone Technology Remote access to logger data over GSM network by SMS text message Remote configuration, status monitoring and preventive maintenance Diagnostics and configuration, via standard GSM mobile phone Automated reporting of metering data via SMS text SMS data accessible via industry-standard SMS Gateways capable of exporting data using Windows DDE, OLE, XML etc. Allows remote software upgrades/enhancements by ABB Fit and Flow No need to match sensor and Transmitter Fast, reliable operation Foolproof, no errors Sensor stores all calibration factors, site setting numbers etc. Volume totalizer and tariff values backed-up every minutes in sensor for total security Multiple, programmable password levels stored for measurement security Standard Tariff Setting AquaMaster incorporates a multiple tariff feature where the accumulated flow volume is routed to one of two 8-digit signed tariffs (tariff A and tariff B), depending on time and date. It is fully programmable by the user for time of day, day of week or date during the year. These user-defined times/dates can be combined in a variety of modes as illustrated in the tables below to produce a variety of tariff regimes. Weekly Cycle Defined Mode Tariff A Tariff B Day time during weekend Yearly Cycle Defined Night time at weekend + day and night during week Day time during week Night time during week + day and night during weekend 3 All day times All night times 4 Night time during weekend Day and night during weekend Day time during weekend + night time during weekend All day times + night time during weekend Day time during weekend + day and night during week Day and night during week Night time during week + day time during weekend Night time during week Mode Tariff A Tariff B Day time during summer Night time during summer + day and night during winter Day time during winter Night time during winter + day and night during summer 3 All day times All night times 4 Night time during summer Day and night during summer Day time during winter + night time during summer All day times + night time during summer Day time during summer + day and night during winter Day and night during winter Night time during winter + day time during summer Night time during winter
Easy, Low Cost Installation No matter what the location or installation requirements, AquaMaster provides a cost-effective solution. Both the sensor and the transmitter can be fully submersible, enabling installation in flooded chambers. In addition, the sensor is buriable, thus eliminating the need for a chamber. Installation merely involves excavating to the pipeline, fitting the sensor and back filling the hole, to ensure very fast, low cost installation. The associated Transmitter is then located in the most convenient position for the user. The elimination of bypasses and ancillary items such as strainers, enables the installation cost to be kept to an absolute minimum. These factors, together with the innovative Fit and Flow system, ensure foolproof installation with total user confidence. Specification Transmitter Mounting Directly on sensor or Remote up to m ( ft) Housing IP8 (NEMA P) Stainless steel housing in a Thermoplastic outer cover with window, encapsulated with polyurethane-based resin. Electrical connections IP8 plug & socket Sensor cable ABB cable supplied as standard SWA cable available (via adaptor box) on application External battery pack IP8 (NEMA P) Battery life @ to C (3 to F) typically years Extended life is possible to give, say, years with a small degradation in response time and slightly increased measurement uncertainty (contact ABB for details). Battery life is shorter with GSM, depending on how frequently it is used and for what period. For example, used once per day for SMS automated reporting of data logged at minute intervals, the life of a battery pack would be typically reduced to approximately 4 years. Pulse and alarm outputs Three bidirectional solid state switches with common isolation ±3V DC ma Output Forward only, or forward plus reverse pulses Output Reverse pulses, or direction indicator Output 3 Alarm indicates any problem with measurement or with power Pulse output Hz maximum, % nominal duty cycle Serial data communications Local Port RS3 compatible via ABB lead (Option) Encoder Interface (non-logging versions only) Function Remote reading of totalizer and serial no. Protocol ABB encoder Connections -wire for inductive pads (max. cable length 8m) 3-wire for AMR Compatible readers Severn Trent Services Smart reader ABB or Elster SR and SR Logicon Versaprobe Itron ERT Compatible inductive pads Starpad ABB Telemetry applications using remote serial data communications Internal GSM modem Dual Band GSM; fully programmable schedule for battery operation and Automated Meter Reading Pressure System External Transducer Pressure range bar g or bar Abs Connection Standard quick-fit male probe connector via an adapter cable Operating temperature range (ambient) to C ( 4 to 8 F) Caution. Protect the sample and transducer from freezing. Accuracy (typical) ±.4% of range Thermal error band (typically C [ F]) ±.% span Cable length or m ( or 33 ft) Temperature Ranges Process C (8 F) C (4 F) Ambient C (4 F) C ( 4 F) Storage C (8 F) 3 C ( F) 3
Logger details (option) Logger Function Default Settings Table Logger 3 Flow & Pressure Flow & Pressure Forward, Reverse, Tariffs & Net Flow Totals No. of Records 883 3 3 Logging Interval to s (adjustable) 4 hours (fixed) Typical Capacity 3 months @min. ~ days @ min. year Mode Cyclic Cyclic Cyclic Use ABB LogMaster Use Technolog (PMAC) Use Primayer Primeware Use OSI PI Database/ CBV (WADIS) System Response Time (Programmable) Minimum s (battery-powered) Languages English French German Spanish Italian Dutch Other languages can be added via Windows download Program (contact ABB) GSM Antenna (option) Mounting Integral with transmitter or remote. Antenna environmental IP (NEMA4) waterproof for accidental submersion (Note. The GSM does not operate with integral antenna under water). General advice is to mount the antenna as high as possible, always outside of any metal enclosure and not under the surface of the ground. Configuration Parameter Default European Default North American Pulse Factor Pulse Units m 3 Ugal Totalizer Units m 3 Ugal Full Scale Flow ISO 44 Qn ISO 44 Qn Flow Units m 3 /h MUGD Velocity Units m/s ft/s Date Format from Country Code DDMMYY MMDDYY Flow Response Time (s) 3 3 Display Flow Rate Yes Yes Display Forward Total Yes Yes Display Reverse Total Yes Yes Display Net Total No No Display Date No No Display Velocity No No Output Option Pulse Forward Pulses Forward Pulses Forward Output Option Pulse Reverse Pulses Reverse Pulses Reverse Profile Factor Probe Insertion Factor 4
Overall Dimensions Dimensions in mm (in.) (4.) Transmitter Mounted on Sensor Dimensions in mm (in.) Ø. (.3) Ø3 (.) (4.) (.8) (.) AquaMaster 3 (.4) 8 (.) (.) Transmitter Mounted Remote from Sensor
Dimensions in mm (in.) 33 (3) 3 (.) 4 (.8) Battery pack External Battery Pack Optional GSM Modem 3 4 3 4 Measurement System Processor Optional RS3 Communication Port Pulse/Alarm Circuits Common Display Local Configuration Adaptor Optional Pressure Transducer Part No. WEBC Electrical Connections
Ordering Information AquaMaster Electronic Water Meter AM/E X X X X X X X X Power Supply Remote Battery (supplied) B Logger/Protocol None ABB Logger ABB Logger BVS ABB Logger Technolog ABB Logger Primayer ABB SMS Logger 3 4 Comms Options None GSM Integral Antenna GSM Remote Antenna (m [3. ft] cable) Language English German Spanish French Dutch Italian D E F H I Pressure Span None Bar Gauge Bar Abs Pressure Transducer None m (. ft) Cable m (33 ft) Cable Labelling Standard Approval Standard
AquaMaster Explorer ABB has Sales & Customer Support expertise in over countries worldwide www.abb.com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in UK (4.) ABB SS/AMAS/E Issue 3 ABB Limited Oldends Lane, Stonehouse Gloucestershire GL 3TA UK Tel: +44 ()43 8 Fax: +44 ()43 89 ABB Inc. E. County Line Road Warminster PA 894 USA Tel: + 4 Fax: + 4 83