EZ-B-10 MAGNETIC BOND SENSOR EZ-T-10 TIMER INPUT MODULE. Modular Kit. Modular Kit. EZ-D-10: DOOR POSITION SENSOR Modular Kit

Similar documents
EMLock 1500 Series. MEA Listed. New Modular Kits. Online System Wizard and Project Manager at

EMLock 1500 Series. MEA Listed

Vertical Housing EMLock Discount Code GK LIST. Retrofit Kit for Discontinued Locknetics 390+ PLUS

EMLock Magnetic Locks

cel SECURITY DOOR CONTROLS Value Engineered Access Hardware sdcsecurity.com Power Supplies Exit Switches

EMLock Magnetic Locks

INSTALLATION INSTRUCTIONS 410/420 SERIES PUSH SWITCH

Excel Series Value Engineered Access Hardware

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

SECURITY DOOR CONTROLS

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK

INSTALLATION INSTRUCTIONS MICRO SHEAR EMLOCKS 1561 & 1562 MAX. HOLDING FORCE 2000 LBS.

Security Door Controls

Power Supplies DORMA PS

Locking Devices. Electromagnetic Locks. Security Door Controls 8 SECURITY DOOR CONTROLS

INSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S

Power Transfer Devices

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

INSTALLATION INSTRUCTIONS SHEAR LOCKING MAGNET 1561TJ MAX. HOLDING FORCE 2000 lbs.

Price List 18.4 PRICES VALID STARTING FEBRUARY 1ST, The Lock Behind Your System. Electric & Mechanical Access Control Hardware

ACCESS & EGRESS POWER SUPPLY & DOOR CONTROLS SOLUTIONS. The lock behind the system. SDCSecurity.com

630 Series Power Supplies

Price List 18.4 PRICES VALID STARTING FEBRUARY 1ST, The Lock Behind Your System. Electric & Mechanical Access Control Hardware

Accessories 286 SDC SECURITY DOOR CONTROLS

Electrified Products ELECTRIFIED PRODUCTS

Electric Dropbolts. Secure and Intelligent Bolts. Fail-Safe Series Functions. DPS & BSS Outputs. Fail-Secure Series Functions

Electromagnetic Locks DORMA EML

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

GRADE 1 ELECTRIFIED CYLINDRICAL & UNIT LOCKS

PRICE LIST - MARCH 2015

Price List 19 PRICES VALID STARTING JANUARY 14, The Lock Behind Your System. Electric & Mechanical Access Control Hardware

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

Installation Instructions

TABLE OF CONTENTS. (8) Delayed Egress Locks & Exit Devices. (1) Documentation. (9) Electric Strikes. (10) Power Supplies & Door Control Modules

Spectra Class - Specification Grade Exit Devices for superior Architectural Style & Performance

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

Spectra Class. N6000 Series Exit Devices SECURITY DOOR CONTROLS. N6100 Rim Mount Exit Device. N6200 Surface Vertical Rod Exit Device.

INSTALLATION INSTRUCTIONS DEGR7700 DELAYED EGRESS ALL IN ONE DEVICE

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

ADA Compliant Solution REV

HANDLING MECHANICAL INSTALLATION

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

LOCKNETICS MagForce+ Series. Locknetics MagForce Traffic Control Magnet MEA

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

Motorized Electric Latch Retraction

REVISED ATM72 Auto Transfer Module

INSTALLATION 8310/8320

Price List No. 16 Rev. B

S6000 Spectra Exit Devices

Heavy Duty Commercial Linear Gate Operator

Push buttons are of two types i) Momentary push button ii) Maintained contact or detent push button

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

280+ SHEARLOCK INSTALLATION AND WIRING MODELS: 280+ and 280+TRD TRD

VERTICAL SECURITY SOLENOID LOCKS

Electrified Lockset 74 SECURITY DOOR CONTROLS

CX-EMF-2 MULTI-FUNCTION RELAY

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview. 11 or 14mm drive output (Option)

Heavy Duty Commercial Linear Gate Operator

SEM SERIES FEATURES SEM 7820 MAGNET SEM FEATURES

Electromagnetic Locks Indoor GEM Series

INSTRUCTION MANUAL MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

2965 Magnetic Shear Lock Installation Instructions

IDEM Solenoid Interlock Safety Switches

7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction

PRIMA

ELECTROMAGNETIC LOCKS

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS

MagForce+ The Positive Force in Electromagnetic Locks

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE ELECTROMAGNETIC LOCK.

RETRO SOLUTIONS PRODUCT CATALOG

SAFETY

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

Actuated Valves. Product Information

M670/M680BD MAGNALOCK SERIES Installation Instructions

STANDARD / DOUBLE STANDARD MAGNETIC LOCK

INSTALLATION MANUAL ACL 5500 COMBUSTION SAFETY CONTROLLER

ALARM CONTROLS CORPORATION MSRP PRICING 2014

LCN SEM SERIES FEATURES. SEM 7820 MAGNET Die Cast, Floor mounted. SEM 7870 MAGNET Die Cast, Dual Sided Floor mounted. SEM FEATURES

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

This Datasheet for the IC670MDL930. Relay 2A 8 Pt. 6 form A/2 form C Isolated.

LOCKNETICS Power Supplies. 510 Series Power Supply Controller 12 and 24 VDC. 505 Series Power Supply. 505DE Series Delayed Egress Controller

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

RETRO SOLUTIONS PRODUCT CATALOG

Safety interlock switch MKey

Safety Control HR1S-AC. Safety Relay HR1S-AC

Package Contents. Mounting Hardware

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

Electropneumatic Timing Relays Series 7000 Industrial

SOLUTIONS ACCESS & EGRESS. The lock behind the system EGRESS CONTROL. 3.1 Egress Bars Key & Exit Switches

Features include : - 2 Auxiliary Channel Output - Silent Arm/Disarm. - 2-Stage Disarm. - 2 Remote Transmitters

GATE BOLT

Holding. Resistance. Inrush. Watts. Amps. Amps. (ohm)

Electromagnetic Lock Reference Chart

Timer Relays - Fixed & Adjustable

WARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.

ADA Compliant Solutions

Transcription:

EZ Option Upgrade Kits - Emlock 1511, 1513, 1571, 1573 EMLock EZ Kits Field Upgradeable Option Modules for 1511, 1513, 1571, 1573 SDC s patented EMLock design represents the pinnacle of magnetic lock evolution. The modular EMLock assembly makes them easy to stock, install, upgrade and maintain. Field Upgradeable by Distributors, Installers and Maintenance Staff No need to ever remove a lock from the frame to upgrade or exchange internal components. FIELD UPGRADE Relock Delay Timer Magnetic Bond Sensor Door Status Sensors Anti-Tamper Switch Holding Force Upgrade Energy Saver Upgrade EZ-T-10 TIMER INPUT MODULE EZ-B-10 MAGNETIC BOND SENSOR EZ-D-10: DOOR POSITION SENSOR EZ-A: ANTI-TAMPER SWITCH www.sdcsecurity.com Email: service@sdcsecurity.com ISO 9001 : 2000 FM 52705

www.sdcsecurity.com E-mail: service@sdcsecurity.com EZ-T-10 TIMER INPUT MODULE Relock Delay Timer, Adjustable 1 to 30 Seconds. Application: The Timer Input Module delays relocking of access controlled doors to provide persons ample time needed for entry or egress. Momentary interruption of power to the lock input activates the timer module. Momentary, N.C. Dry Contact required. Contact actuation unlocks the door for 1 30 seconds. 2007 Security Door Controls Printed in the U.S.A. LIT-Datasheet date qty vendor

EZ Option Upgrade Kits - Emlock 1511, 1513, 1571, 1573 * Not available for 1513, 1573 While a Door Status Sensor indicates the door is open or closed, SDC s Magnetic Bond Sensor provides higher security monitoring by indicating the locked / unlocked mode, tampering and low holding force. The use of both the door status and magnetic bond sensor is recommended for high security applications. EZ-B-10 MAGNETIC BOND SENSOR Application: Output: Lock secure status annunciation, mantrap system logic, CCTV camera activation. SPDT Dry Contact, 250 ma @ 12/24VDC www.sdcsecurity.com Email: service@sdcsecurity.com ISO 9001 : 2000 FM 52705

www.sdcsecurity.com E-mail: service@sdcsecurity.com EZ-D-10: DOOR POSITION SENSOR Indicates the door is open and closed. * Not available for 1513, 1573 Application: Door position status annunciation, anti-tailgating, interlock, mantrap and communicating bathroom system logic. Output: SPDT Dry Contact, 250 ma @ 12/24VDC EZ-A: ANTI-TAMPER SWITCH - Indicates cover plate removal 3 Anti-tamper wiring Output: SPDT Dry Contact, 3 Amp @ 12/24VDC Com No NC 2007 Security Door Controls Printed in the U.S.A. LIT-Datasheet date qty vendor

EZ Option Upgrade Kits - Emlock 1511, 1513, 1571, 1573 EZ 1510W Holding Force Upgrade EZ 1570W Energy Saver Upgrade All 1511, 1512, 1513, 1571, 1572 and 1573 magnetic coils are field interchangeable without removing the lock from the frame. There is no reason to remove and ship a lock for exchange. Benefits of this interchangeability include: EZ-1510W Holding Force Upgrade: Exchange 1200 lb coil with 1650 lb holding force coil EZ-1570W Energy Saver Upgrade: Save on power supply and long term energy costs by exchanging 8.4 Watt,1650 lb coil with 3 Watt, 1200 lb holding force coil Eliminate labor, shipping costs and time associated with special orders or complete lock removal and replacement. Applications Distributors with limited stock may exchange coils to fulfill specific special sales needs, i.e. a 1570 with Dark Bronze finish may be upgraded to a 1511 with dark bronze finish and visa versa. Installers may field upgrade to an Energy Saver where power supply capacity is limited or upgrade to higher holding force where 1200 lbs holding force proves inadequate, i.e. psychiatric or rehab center applications. www.sdcsecurity.com Email: service@sdcsecurity.com ISO 9001 : 2000 FM 52705

www.sdcsecurity.com E-mail: service@sdcsecurity.com 2007 Security Door Controls Printed in the U.S.A. LIT-Datasheet date qty vendor