READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

Similar documents
Air Bear Right Angle. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

Air Bear Supreme and Air Bear Cub. Media Air Cleaners READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

UV-AIRE AIR PURIFYING SYSTEM

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

HARDWARE KIT INSTALLATION GLOVES

INSTALLATION INSTRUCTIONS

UV-AIRE AIR PURIFYING SYSTEM

Safety, Installation and Service Manual Models 1952, 1953 & 1972

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

Installation Instructions

21", 33", 45", & 61" Installation & Operation Manual

WARNING Risk of property damage, injury, or death.

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

BIO-FIGHTER 4Xtreme 21", 33", 45" Ultraviolet Light Systems

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

LED LARGE WALL PACK (CUTOFF & STANDARD)

POST LANTERN ITEM # MODEL #39487 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

Installer s Manual. PCO/UV N-Duct Model

BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

MaxLite LED UTILITY WRAP FIXTURES

Level One Electric Vehicle Charging Station Wall Mount Product Guide

Air Curtain. Installation, Operating and Maintenance Instructions

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

37SCENE 46SCENE 79SCENE

Illustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

POST LANTERN ITEM # MODEL #39434 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

Instruction Manual. Fudge Puppy Display Case

PHOTO-CATALYTIC AIR PURIFIER SYSTEMS

MINISTICK TM UV Germicidal Ultraviolet Light

3-LIGHT VANITY BAR ITEM # MODEL #34674 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

StormPro BA Series Sump Pump

CAUTION: Read manual carefully for proper procedures and operation.

PY-11 Voltage & Continuity Tester

Automatic Emergency Light

This Manual Provides Installation and Operation Instructions for the following models:

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

Installation Instructions

900 PEAK AMP PORTABLE JUMP STARTER

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

MODEL TC400 TIRE CART. Installation, Operation & Repair Parts Information REV P/N:

HA/HAB Fiberglass Wall Mount Ventilators

STOP. LP-50DEF-BRL Lever Hand Pump System Barrel Mounting. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS

360 Watt Charge Controller

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

ESE Series Cast Iron Sewage Pumps

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Swing Arm Magnifying Lamp

Page Number. Contents: Product Features 2. Physical Data 2. Nomenclature. 3. Blower Performance 3. Electrical Data 4. Warranty.. 6

MaxLite LED Enclosed & Sealed Jelly Jars

16 Inch Hanging Pendant Barn Light

ITEM # , WALL LANTERN MODEL #40683, Portfolio is a registered trademark of LF, LLC. All Rights Reserved. Français p.

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

GORE TRAILER MANUFACTURING INCORPORATED 305 Gore Trailer Road Whiteville, North Carolina 28472

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Heavy Duty Four Wheeled Walker

Model 8144NC Fresh Air Ventilator

Model G14SD Vapor Management System

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

INSTALLATION TEMPLATE

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

1. Contents 1. CONTENTS INTRODUCTION SAFETY WARNINGS POWER TILT STANDARD OPERATING INSTRUCTIONS... 5.

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

! WARNING! WARNING. Dock Boxes Unlimited, Inc. strongly recommends that these products be installed by a qualified electrician.

OPERATING MANUAL 18V Ni-Cd Battery Pack

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Installation manual. 2 front / 1 rear spacer kit Jeep Wrangler JK 2 & 4 door Part # 42005

HBC-20 - LED HIGH BAY

BCFS Belt Driven Centrifugal Filtered Supply Fans

FAN POWERED HEPA FILTER UNIT


6 OFF ROAD LIGHT BAR

Power Controller IMPORTANT INFORMATION. What s In the Box? Assembly, Operation, & Maintenance

Kitchen Tech Series Air Curtain

PVI 60KW, PVI 82KW, PVI 95KW

INSTALLATION AND OPERATING INSTRUCTIONS. First READ THIS MANUAL. If you still need help, call us from 9 am to 4 pm (central time) Monday Friday.

Tiller Lock Assembly

Installation & Maintenance of the Fresh-Aire UV Tubular Rack System for Commercial Air Handler Systems

WARRANTY. Air flow. (Please note standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

Submersible Pond Pump with UV 800 Gallons Per Hour

LIBERATOR USER MANUAL

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

110 Volt/12 Volt Portable Inflator

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

MaxLite StaxMax LED Flood Lights

INSTALLATION & OWNER'S MANUAL

HANGING LANTERN ITEM # MODEL #CP199MBK. Français p. 9. Español p. 17 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

SUBMERSIBLE MINI-PUMP

G8 Portable Fuel Transfer Pump Owner s Manual

WARNINGS, CAUTIONS AND NOTES

Transcription:

READ AND SAVE THESE INSTRUCTIONS ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner Trion www.trioniaq.com

Installation, Operation, & Maintenance Manual 1. Warranty 2. Safety & Warnings ComfortBreeze UV360 System 1-Year Limited Warranty This limited warranty covers Trion Residential Type UV Air Cleaners, excluding duct work, wiring and installation. Trion warrants that all new Trion UV Air Cleaners are free from defects in material and workmanship under normal, non-commercial use and service. Trion will remedy any covered defects if they appear within 12 months from the date of original installation & subject to the terms and conditions of this Limited 1-Year Warranty stated below: 1. THIS LIMITED 1-YEAR WARRANTY is granted by Trion Customer Service, 101 McNeill Road, Sanford, NC 27330. 2. This warranty shall extend only to any non-commercial owner who has purchased the residential UV Air Cleaner other than for purposes of resale. 3. All components are covered by this limited warranty except expendable items. 4. If, within the warranty period, any Trion residential UV Air Cleaner or component requires service it must be performed by a competent heating and/or air conditioning contractor (preferably the installing contractor). Trion will not pay shipping charges, or labor charges to remove or replace such defective parts or components. If the part or component is found by inspection to contain such defective material and workmanship it will be either repaired or exchanged free of charge at Trion s option, and returned freight collect. 5. In order to obtain the benefits of this limited 1-year warranty, the owner must notify the dealer or distributor of any defect within 30 days of its discovery. If after reasonable time you have not received an adequate response from the dealer or distributor, notify in writing to Trion Customer Service 101 McNeill Road, Sanford, NC 27330, or call 1-800-884-0002 or email customerservice@trioniaq.com. UV Air Cleaners which have been installed or become part of real estate cannot be returned. Trion will receive, freight prepaid, only removable parts or components of such defective UV Air Cleaners. 6. This limited warranty does not apply to any part or component that is damaged in transit or in handling, has been subject to misuse, neglect or accident; has not been installed, operated and serviced according to Trion s instructions; has been operated beyond the factory rated capacity; or altered in any such way that its performance is affected. There is no warranty due to neglect, alteration or ordinary wear and tear. Trion s liability is limited to replacement of defective parts or components and does not include the payment of the cost of labor charges to remove or replace such defective components or parts. 7. Trion will not be responsible for loss of use of any product; loss of time, inconvenience, or any other indirect, incidental or consequential damages with respect to person or property, whether as a result of breach of warranty, neglect or otherwise. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE LIMITATION OR EXCLUSION IN THE PRECEDING SENTENCE MAY NOT APPLY TO YOU. 8. THIS WARRANTY GIVES YOU SPECIFIC RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. 9. Any warranty by Trion of merchantability, fitness for use or any other warranty (express, implied or statutory), representation or guarantee other than those set forth herein, shall expire at the expiration date of this express limited warranty. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE LIMITATION IN THE PRECEDING SENTENCE MAY NOT APPLY TO YOU. 10. Trion reserves the right to make changes in the design and material of its products without incurring any obligation to incorporate such changes in units completed on the effective date of such change.! DANGER RISK OF ELECTRIC SHOCK Before installlation, cleaning, servicing, or parts replacement, the unit must be disconnected from all sources of electricity. There may be more than one switch. Never expose eyes or skin to the UVC light. Looking directly at a UVC light source may cause permanent eye damage or even blindness. Never operate the UV360 Purifying System outside plenum. This product is designed for a closed HVAC duct system. Do not mount near a supply or a return air opening. All duct openings in direct line of site of the UVC energy source is to be sealed, using an aluminum tape or an equivalent sealing product. Improper installation, adjustment, alteration, service, or maintenance may cause property damage, injury, or death. This appliance must be installed according to these instructions. Read these instructions thoroughly before installing or servicing the unit. Read these instructions thoroughly before installing this unit. Check data label and verify electrical specifications agree with those at the point of installation. Installation in freezing conditions can result in unit failure. Damage to personal property may also result. Trion recommends that this UV Air Cleaner be installed by a trained HVAC professional. Do not connect the unit to the power source until the installation is complete. A thorough checkout of the unit installation should be completed before operating the unit. Failure to follow these directions may void the manufacturer s original warranty. Electrical power to the furnace must be disconnected before proceeding. Serious injury or death may result. If the UV lamp is broken, DO NOT TOUCH the lamp or internal contents of lamp. The lamp contains mercury. After opening the carton, unpack and inspect the unit and lamp for damage. Do not install this unit if any noticeable damage. If lamp is damaged do not touch lamp or other contents in carton. Close carton and return to seller immediately. In case of accidental exposure to internal contents of lamp, wash hands and affected skin with mild detergent. Remove any affected clothing immediately. If skin has been pierced, seek medical attention immediately. 2 www.trioniaq.com ComfortBreeze UV360-1 System

3. Application Installation, Operation, & Maintenance Manual 5. Power Requirements The UV360 s unique low-voltage 24V power supply delivers up to 22 Watts of UV-C power into most any application. Its lamp and socket are water-resistant, and 24V power means reduced danger from fire or shock. The UV360 installs simply from the exterior of HVAC equipment, no need to access the systems interior. Simply create a 2-7/8 insertion hole at the intended site, mount the fixture and plug its UL Listed adapter into a nearby wall socket, or, wire it to a suitable 24V power source (with no power fluctuations). NOTE: THE UV360 IS RATED AT 22VA. IT IS RECOMMENDED THAT THE ANTICIPATED 24V SOURCE BE CHECKED FOR ITS ABILITY TO SERVICE A 22VA LOAD. A SEPARATE TRANSFORMER IS RECOMMENDED. 4. Safety Considerations Improper installation, adjustment, alteration, service, maintenance, or use can cause fire, electrical shock, or other conditions which may cause personal injury or property damage and loss of warranty. Consult a qualified installer, service agency, or your supplier for information or assistance. The qualified installer or agency must use factory kits or accessories when installing this product. Refer to the individual instructions packaged with kits or accessories when installing them. Follow all safety codes and wear safety glasses and work gloves. Read all instructions thoroughly and follow any warnings or cautions attached to any accessed area. Consult local building codes and the National Electrical Code (NEC) for all applicable requirements. Understand the signal words DANGER, WARNING or CAUTION. These words are universally used for overall safety. DANGER identifies the most serious hazards, which will result in severe personal injury or death. WARNING signifies hazards, which could result in personal injury or death. CAUTION is used to identify unsafe practices, which would result in minor personal injury or product and property damage and loss of warranty. 4. General 1. UV360 fixtures are used to bathe surfaces, air or both with UV-C energy. For surfaces locate the UV360 at known growth areas such as above the coil and drain pan first, then other moist areas around humidifiers, etc. They can also be placed in return, supply and mixed air plenums or any combination of these locations. The UV360 is rated at 24V DC 50/60Hz-1 AMP. 6. Installation (designed for metal plenums/drain pans and ducting): 1. Consult all applicable codes before installing. Check fixture label(s) for the correct power requirements and supply the correct voltage from a suitable, protected (fused or breaker), and grounded power source. Using other than labeled voltages voids warranty and may damage to the entire system. Operate fixture continuously to avoid growth of mold and bacteria in damp areas (when AHU is off) and to extend product life. 2. Power must also be switched, at all install access points, with a properly rated SPST interlock switch to completely deenergize the assembly when its install location is accessed. Accesses are to have signs in appropriate languages alerting maintenance personnel to the possible hazard of looking at, or exposing skin to UVC energy (English label(s) provided). NOTE: UV-C energy may damage certain plastics. Protect susceptible items with UV-C resistant materials such as aluminum tape, foil or aluminum paint when these items are in line of sight of UV-C energy. 3. Determine mounting location and apply template - cut the hole using the included 2 7/8 hole saw. 4. When installing on duct-board, use the provided Duct-Board Mounting Plate to provide a stronger mounting surface. Apply template to the Duct-Board Mounting Plate. Do not drill into refrigerant lines or other critical system components. After cutting hole, avoid sharp edges. 5. Slide mounting ring into hole and affix with 3 Phillips screws (Image B) 2. Check first for power 120V wall socket availability or 24V DC and all probable service accesses. What s in the Box? UV360 Description 167315-001 UV-C Light Kit* 167315-102 UV Bulb, 17 Phillips * UV-C Light Kit includes hole saw, installation template, mounting ring, and 24V DC adapter. Image A: Mounting Ring Image B: Mounting Ring ComfortBreeze UV360-1 System www.trioniaq.com 3

Installation, Operation, & Maintenance Manual 7. Connecting Power 6. Remove LampClamp nut (image C). Insert lamp into socket until it clicks in. Slide LampClamp over end of lamp and hand tighten. 1. Hardwiring: Read labeled power requirements wire to 24V-1A, DC power, in accordance NEC and local codes. 2. All power-in wire and switch ratings must be in accordance with applicable codes. Power must also be switched at all install access points with a properly rated, SPST interlock switch in order to completely de-energize the assembly when its install location is accessed. 3. Connect power cap (white) to fixture and twist clockwise to secure. 4. Soft wiring: A 24V DC adapter is provided. Plug adapter into 120V wall socket and secure. Image C: LampClamp Locking Clip 8. Maintenance UV-C lamps should be replaced annually. While there still may be a visible blue light, this is not an indication of UV-C output (the UV-C wavelength is invisible). Contact your local Trion representative or visit www.trioniaq.com. Lamp part number: 167315-102. 7. Insert power supply/uv lamp into the mounting ring; pull up on yellow locking clip; turn clock-wise until power supply is fully installed. 8. Push-in yellow locking clip to lock power supply into mounting ring (photo C). 4 www.trioniaq.com ComfortBreeze UV360-1 System

9. Diagrams Installation, Operation, & Maintenance Manual 18 Power Cap 4.72 Lamp Clamp UV-C Lamp UV360 24V power supply (ballast) Lamp Socket Mounting Ring 10. Installation Location Options The ComfortBreeze UV360 24V UV-C fixture can be placed in several locations in the A/C system. Images of typical residential A/C systems and the various locations that the ComfortBreeze UV360 can be installed are as follows: A = Best installation B = Better installation C = Good installation Typical Horizontal A-Coil: Right Airflow (Figures 3 and 4) Figure 3 Typical Upflow Coil Figure 4 Typical Horizontal Slab Coil (Figures 1 and 2) Figure 1 Figure 2 Typical Horizontal A-Coil: Left Airflow (Figure 5) Figure 5 ComfortBreeze UV360-1 System www.trioniaq.com 5

Trion 101 McNeill Rd. Sanford, NC 27330 P: 800.884.0002 F: 800.458.2379 www.trioniaq.com customerservice@trioniaq.com Form No. 167315-500 Rev. 05/15 Trion 2015. All Rights Reserved.