Proportional pressure reducing valve of 3-way design

Similar documents
Proportional pressure reducing valve of 3-way design Types 3DREP and 3DREPE

Proportional pressure reducing valve, in 3-way version

4/2- and 4/3-way proportional directional valves, direct actuated, without electrical position feedback Types 4WRA and 4WRAE

Proportional pressure reducing valve, 3-way variant, pilot operated

Proportional pressure relief valve, pilot operated

4/2- and 4/3-way proportional directional valves, direct operated, without electrical position feedback, without/with integrated electronics (OBE)

4/2, 4/3, and 5/2, 5/3 proportional directional valve, pilot operated, without electrical position feedback without/with integrated electronics (OBE)

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

3/2 and 4/2 directional poppet valve with solenoid actuation

3-way Proportional pressure reducing valve, pilot operated

Proportional pressure relief valve Types DBE(M) and DBE(M)E

4-way directional servo-valve

Pressure reducing valve, direct operated

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated

Meter-in pressure compensator, direct operated

Proportional pressure reducing valve, pilot operated

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Industrial Hydraulics FAQs

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

Proportional pressure relief valve, pilot operated

Directional servo-valve of 4-way design

Directional servo-valve in 4-way design

Servo directional valve of 4-way design Type 4WS.2E

Proportional flow control valve. Type 2FRE. Features. Contents. RE Edition: Replaces: 02.07

Proportional pressure relief valve Types DBE(M) and DBE(M)E

2-way proportional throttle valve for block installation

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Check valve, pilot operated

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

2-way flow control valve

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

Check valve, pilot operated

3/2 and 4/2 directional seat valves with solenoid actuation

Proportional flow control valve with integrated pressure compensator Type KUDSR

Pressure sequence valve, direct operated

3/3 servo directional control valve with mechanical position feedback

2- and 3-way high-response cartridge valve

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

4-way directional servo valve Type 4WS.2E

Servo solenoid valves with on-board electronics (OBE)

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Industrial Hydraulics FAQs

Proportional flow control valve, 2-way version

3/2 and 4/2 directional seat valves with solenoid actuation

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ)

4/2 Directional valve elements with or without secondary relief valves, with or without LS connections, and with 2/2 solenoid cartridge valve

Pressure reducing valve, pilot operated Type DR

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Accumulator shut-off block. Type 0532VAW. Contents. Features. RE Edition: Replaces: 07.10

Supply pressure compensator, direct operated

Proportional pressure relief valve Type DBETRE

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

Twin throttle check valve

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRTE. Features.

Throttle check valve. Type Z2FS. Features. Content. RE Edition: Replaces: 04.08

Pressure reducing valve, direct operated

Proportional flow control valve, with integrated pressure compensator

Pressure sequence valve, direct operated

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

Check valve, pilot operated

Hydraulic pilot control unit of sandwich plate design for the remote control of directional valves, pumps, motors

Check valve, pilot operated

2-way flow control valve

Traction module (Flow divider) RTM

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Servo solenoid valves with positive overlap and on-board electronics (OBE)

Check valve, pilot operated

RC /

Open center control block in mono block design MO-16, 22, 32

Pipe burst safety valve

Pressure reducing valve, direct operated, with pressure monitoring

Direct Operated Proportional DC Valves

LUDV control block of sandwich plate design

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Filling valve sandwich plate

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Pressure relief valve, pilot operated

Winch control block. RE 65051/08.04 Replaces: Type YM-WCB

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Pressure reducing valve, direct operated

3/2 directional spool valve, direct operated with solenoid actuation

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Proportional pressure relief valve, directly operated, rising characteristic curve

Single-circuit power brake valve LT 05

Pressure reducing valve, pilot operated

Throttle check valve. Type Z2FS. Size 16 Component series 3X Maximum operating pressure 350 bar [5076 psi] Maximum flow 250 l/min [66 US gpm]

Throttle and throttle check valve

Pressure relief valve, pilot-operated. Type DB and DBW. Features. Contents. RE Edition: Replaces:

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

B8_58 (EDBZ-VEI) RE Edition: Replaces:

Transcription:

Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Electric Drives and Controls Hydraulics Linear Motion and ssembly echnologies neumatics Service roportional pressure reducing valve of 3-way design Model 3DRE and 3DREE Nominal size 6 Component series 2X Maximum operating pressure 100 bar (1450 SI) Maximum flow 15 L/min (3.96 GM) able of contents Contents age Features 1 Ordering details 2 Standard types 2 Symbols 2 Function, section 3 echnical data 4, 5 Electrical connections, plug-in connectors 5 Control electronics 5, 6 Characteristic curves 7 Unit dimensions 8, 9, 10 hrottle insert 10 3DRE 6.-2X/..EG24N9K4... with plug-in connectors and associated control electronics (separate order) Features R 29184/12.02 Replaces: 06.98 1/12 3DREE 6.-2X/..EG24N9K31... with integrated control electronics Directly controlled proportional valves for the control of the pressure and direction of a fl ow Operated via proportional solenoids with central thread and removable coil For subplate mounting: orting pattern to DIN 24 340 part 2 Form, ISO 4401 and CEO-R121H Subplates to catalogue sheet RE 45 052 (separate order), see pages 8 to 10 Hand override, optional Spring centred control spool ype 3DREE with integrated control electronics, interface 1 External control electronics for type 3DRE: nalogue amplifi er type V-VS2-1-2X/ in Euro - card format (separate order), see page 5 Digital amplifi er type V-VSD-1-2X/ in Eurocard format (separate order), see page 5 Electrical amplifi er type V 11118 of modular design (separate order), see page 5

2/12 osch Rexroth Corp. Industrial Hydraulics 3 DRE / 3DREE R 29184/12.02 Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Ordering details For external control electronics = No code With integrated control electronics = E Nominal size 6 = 6 Symbols (simplified) a Standard types ype 3DRE 3DRE 6-2X/16EG24K4/M 3DRE 6-2X/25EG24K4/M 3DRE 6-2X/45EG24K4/M 3DRE 6 C-2X/16EG24K4/M 3DRE 6 C-2X/25EG24K4/M 3DRE 6 C-2X/45EG24K4/M Symbols = = = C Series 20 to 29 = 2X (20 to 29: unchanged installation and connection dimensions) ressure stage 16 bar (232 SI) = 16 ressure stage 25 bar (362.6 SI) = 25 ressure stage 45 bar (652.7 SI) = 45 1) Suitable for mineral oil (HL, HL) to DIN 51 524 2) For version J = sea water resistance only state K31 3) For version J = N instead of N9 Special types of electrical protection on request! ype 3DRE.. 6 2X/...E (detailed) 3DRE 6 2X / E G24 / ype 3DRE.. 6 2X/...E (detailed) a a b b b Material No. R900954474 R900954417 R900954418 R900954419 R900954420 R900954421 E = G24 = ype 3DREE 3DREE 6-2X/16EG24K31/1M 3DREE 6-2X/25EG24K31/1M 3DREE 6-2X/45EG24K31/1M 3DREE 6 C-2X/16EG24K31/1M 3DREE 6 C-2X/25EG24K31/1M 3DREE 6 C-2X/45EG24K31/1M M = 1) V = Further details in clear text NR seals FKM seals No code = For 3DRE For 3DREE 1 = Com. value input ±10 V Electrical connections For 3DRE K4 = 2) Without plug-in connector, with component plug to DIN EN 175 301-803 lug-in connector - separate order, see page 5 Fow 3DREE K31 = 2) Without plug-in connector, with component plug to DIN EN 175 201-804 lug-in connector - separate order, see page 5 No code = J = No code = N9 = 3) Without special protection Sea water resistant Without hand override With protected hand override Supply voltage for the control electronics 24 V DC roportional solenoid with removable coil ype 3DRE.. 6 C 2X/...E (detailed) a Example of a valve with integrated control electronics ype 3DREE.. 6 C 2X/...E (simplified) a * b b Material No. R900954422 R900954423 R900954424 R900954425 R900954427 R900954428

3 DRE / 3DREE R 29184/12.02 Industrial Hydraulics osch Rexroth Corp. 3/12 Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Function, section he 3-way pressure reducing valve type 3DRE 6.. is directly operated by proportional solenoids. hey convert an electrical input signal into a proportional pressure output signal. he proportional solenoids are controlable wet pin DC solenoids with central thread and removable coil. he solenoids are controlled optionally via external control electronics (type 3DRE) or by integrated control electronics (type 3DREE). Design: he valve mainly comprises of: Housing (1) with mounting surface Control spool (2) with pressure measuring spools (3 and 4) Solenoids (5 and 6) with central thread Optional integrated valve electronics (7). Function: With the solenoids (5 and 6) de-energised the control spool (2) is held in its centre position by compression springs he control spool (2) is directly operated when one of the solenoids is energised. ype 3DRE 6.. ype 3DREE 6.. 9 Valve with 2 switching positions: (types 3DRE.. or 3DRE.. ) he function of this version of the valve is basically the same as that of the valve with 3 switching positions. he 2 position valves are however only fitted with either solenoid a (5) or solenoid b (6). plug (8) is fitted in place of the second solenoid. "a" 7 E. g. by energising solenoid a (5). he pressure measuring spool (3) and control spool (2) moves to the right in proportion to the electrical input signal. he connection from to and to is via orifice form cross-sections with progressive flow characteristics. De-energising of the solenoid (5). he control spool (2) is returned to its centre position by the compression springs. In the middle position the connections and to are open, therefore the pressure fluid can freely flow to tank. n optional hand override (9 and 10), makes it possible to move the control spool (2) without energising the solenoid. ttention! Unintended use of the hand override can cause uncontrolled machine movement! 5 3 2 4 1 6 "a" 8 8 "b" "b" Note: Draining of the tank line is to be prevented. aking the installation conditions into account a back pressure valve is to be fitted (back pressure approx. 2 bar). 10

4/12 osch Rexroth Corp. Industrial Hydraulics 3 DRE / 3DREE R 29184/12.02 Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com echnical data (for applications outside these parameters, please consult us!) General Valve type 3DRE 3DREE Installation Optional, preferably horizontal Storage temperature range C ( F) 20 to + 80 ( 4 to + 176) mbient temperature range C ( F) 20 to + 70 ( 4 to +158) 20 to + 50 ( 4 to +122) Weight kg (lb) 2.0 (4.4) 2.2 (4.84) Hydraulic Operating pressure range ort bar (SI) 20 to 100 (290 to 1450) for pressure stage 16 bar (SI) 30 to 100 (435 to 1450) for pressure stage 25 bar (SI) 50 to 100 (725 to 1450) for pressure stage 45 ort bar (SI) 0 to 30 (0 to 435) Max. fl ow L/min (GM) 15 (4.0) Δp = 50 bar (725 SI) ressure fl uid Mineral oil (HL, HL) to DIN 51 524 Further fl uids on request! ressure fl uid temperature range C ( F) 20 to +80 ( 4 to +176) preferably +40 to +50 (+104 to +122) Viscosity range mm 2 /s (SUS) 20 to 380 (97 to 1760) preferably 30 to 46 (141 to 215) Cleanliness class to ISO code Maximum permissible degree of contamination of the pressure fl uid is to ISO 4406 class 17/15/12 1) Hysteresis % 5 Repeatability accuracy % 1 Response sensitivity % 0.5 Reversal span % 1 Electrical, solenoid Valve type 3DRE 3DREE Voltage type DC Signal type nalogue Command value signal Voltage input 1 V ± 10 Max. current per solenoid 1.5 2.5 Solenoid coil resistance Cold value at 20 C Ω 4.8 2 Max. warm value 7.2 3 Duty % 100 Coil temperature C ( F) Up to 150 (302) Electrical connections 3DRE With component plug to DIN EN 175 301-803 lug-in connector to DIN EN 175 301-803 2) 3DREE With component plug to E DIN 43 563-M6-3 lug-in connector E DIN 43 563-F6-3/g11 2) rotection to DIN EN 60 529/VDE 0470 part 1 I65 with mounted and fi xed plug-in connector 1) he cleanliness class stated for the components must be adhered too in hydraulic systems. Effective fi ltration prevents faults from occurring and at the same time increases the component service life. For the selection of fi lters see catalogue sheets RE 50 070, RE 50 076 and RE 50 081. 2) Separate order, see page 5

3 DRE / 3DREE R 29184/12.02 Industrial Hydraulics osch Rexroth Corp. 5/12 Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com echnical data (for applications outside these parameters, please consult us!) Electrical, control electronics Integrated, control electronics for type 3DREE Integrated into the valve, see page 6 Supply voltage Nominal voltage VDC 24 Lower limiting value V 19 Upper limiting value V 35 mplifi er I max 1.8 current consumption Impulse current 4 External, control electronics for type 3DRE nalogue amplifi er With 1 ramp time V- VS2-50-1X/1, to catalogue sheet RE 30 113 in Eurocard format 1) With 5 ramp times V- VS2-50-1X/5, to catalogue sheet RE 30 113 Digitale amplifi er in Eurocard format 1) V-VSD-1-2X/, to catalogue sheet RE 30 523 mplifi er of modular design 1) V 11118-1X/..., to catalogue sheet RE 30 218 1) Separate order Note: For details regarding the environmental simulation test covering EMC (electro-magnetic compatibility), climate and mechanical loading see RE 29 184-U (declaration regarding environmental compatibility). Electrical connections, plug-in connectors (dimensions in mm) For type 3DRE (for external control electronics - not for version J = sea water resistant) Connections at component plug E 1 2 E 1 2 lug-in connector to DIN EN 175 301-803 Solenoid a, colour grey Separate order under Material No. R900074683 Solenoid b, colour black Separate order under Material No. R900074684 For type 3DREE (with integrated control electronics and for version J = sea water resistant) lug-in connector to DIN EN 175 201-804 Separate order under Material No. R900021267 (plastic version) For pin allocations see block circuit diagram on page 6 Ø 27 (7.13) 91 (24.03) 27.5 (1.08) 30 (1.18) 36 (1.42) Connections at plug-in connector Ø 6.5 Ø 11 (1.72...2.91) E 1 2 o amplifier 53 (2.09) 27.5 (1.08) 30 (1.18) C D F E E 1 2 o amplifier Ø 22.5 (0 89)

6/12 osch Rexroth Corp. Industrial Hydraulics 3 DRE / 3DREE R 29184/12.02 Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Integrated control electronics for type 3DREE lug allocation, component plug Integrated control electronics (see below) Slot Signal Supply 24 VDC (19 to 35 VDC) voltage GND C n.c. Differential D Com. value (± 10 V / 4 to 20 m) input E ref. potential Command value: positive command value (or 12 to 20 m) at D and the reference potential at E results in pressure in. negative command value (or 12 to 4 m) at D and the reference potential at E results in pressure in. For a valve with one solenoid on side b (version ), a positive command value at D (4 to20 m) and the reference potential at E, results in pressure in and for a valve with one solenoid on side a (version ) a positive command value at D (4 bis 20 m) and the reference potential at E, results in pressure in. Connection cable: Recommended: Up to 25 m cable length type LiYCY 5 x 0.75 mm 2 Up to 50 m cable length type LiYCY 5 x 1.0 mm 2 Outside diameter 6.5 to 11 mm Only attach the screen to E on the supply line. lock circuit diagram / connection allocation for the integrated electronics ower supply: Interface Integrated control electronics Valve Com. value Ref. potential 24V GND rotective conductor D E E C D E F Differential amplifier 1 U U Under voltage recognition ower supply U U Ramp generator Step function generator 1 rotective conductor screwed onto housing and cover 2 Ramp from 0 to5 s can be externally adjusted ( up down ) 1) Output stages are current controlled 2 + U i 0 V U i F Summator Interlock n.c. Output stage 1) U I Output stage 1) U I

3 DRE / 3DREE R 29184/12.02 Industrial Hydraulics osch Rexroth Corp. 7/12 Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Characteristic curves - measured with HL-46, ϑ oil = 40 C ±5 C (104 F ±41 F) and p = 100 bar (1450 SI) ressure stages 16, 25 and 45 bar (230, 360 and 650 SI) Nominal pressure in % Flow in L/min Output pressure in % Command value in % ressure stages 16, 25 and 45 bar (230, 360 and 650 SI) ressure-flow relationship 100 80 60 40 20 16 0 1015 20 30 40 50 60 70 80 90 100 140 120 100 60 (15.85) 50 (13.21) 40 (10.57) 80 60 40 20 30 (7.93) 20 (5.28) 10 (2.64) 0 25 () 0 10 (145) or 20 (290) ressure differential in bar Flow in L/min 30 (435) 40 (580) 50 (725) or 20 15 10 5 0 5 10 15 ()

8/12 osch Rexroth Corp. Industrial Hydraulics 3 DRE / 3DREE R 29184/12.02 Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Unit dimensions: type 3DRE (dimensions in mm) 3 5 9 1 2 7 9 6 4 8 10 1 Valve housing 2 Name plate "a" 3 roportional solenoid a 42 (11.10) 8.5 (2.26) 69 (18.23) 31 (8.19) 156.5 (41.34) 227 (59.97) 13.5 (3.57) 4 roportional solenoid b 5 lug-in connector, colour grey (separate order, see page 5) 6 lug-in connector, colour black (separate order, see page 5) 7 Identical seal rings for ports,, and 8 rotected hand override N9 9 Cover for valves with one solenoid (versions or ) 10 Space required to remove the plug-in connector 11 Machined valve mounting face and position of the ports 40.5 (10.70) 32.5 (8.59) "b" 79 (20.87) 32 47 (12.42) 0.01/100 mm 0.0004/4.0 in. (R max 4) Required surface finish of the mating piece 15 (3.96) 85.5 (22.59) 23 (6.08) 47 (12.42) 8 (2.12) 31 (8.19) 15 (3.96) 72 (19.02) Subplates: G 341/01, G 1/4 (SE-4; 7/16-20) G 342/01, G 3/8 (SE-6; 9/16-18) G 502/01, G 1/2 (SE-8; 3/4-16) Valve fixing screws: 4 socket head cap screws M5 x 50 DIN 912 10.9 (10-24 UNC x 2 ) ightening torque M = 8.9 Nm (6.56 lb-ft) 11 (2.91) 40.5 (10.70) 44 (11.62) 0.75 (0.20) 31.75 (8.39)

3 DRE / 3DREE R 29184/12.02 Industrial Hydraulics osch Rexroth Corp. 9/12 Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Unit dimensions: type 3DRE...J sea water resistant (dimensions in mm) 15 (3.96) 10 1 Valve housing 2 Name plate 5 3 roportional solenoid a 4 roportional solenoid b 3 9 7 1 9 4 31 (8.19) "a" 5 lug-in connector (separate order, see page 5) 7 Identical seal rings for ports,, and ) 8 rotected hand override N 9 Cover for valves with one solenoid (versions or ) 10 Space required to remove the plug-in connector 11 Machined valve mounting face and position of the ports 2 8.5 (2.26) 69 (18.23) 188.5 (49.80) 13.5 (3.57) 42 (11.10) 292 (77.14) 282 40.5 (10.70) "b" 32.5 (8.59) 32 79 (20.87) 47 (12.42) 0.01/100 mm 0.0004/4.0 in. (R max 4) Required surface finish of the mating piece 23 (6.08) 8 (2.12) 31 (8.19) 89 (23.51) 15 (3.96) 72 (19.02) Subplates: G 341/01, G 1/4 (SE-4; 7/16-20) G 342/01, G 3/8 (SE-6; 9/16-18) G 502/01, G 1/2 (SE-8; 3/4-16) Valve fixing screws: 4 socket head cap screws M5 x 50 DIN 912 10.9 (10-24 UNC x 2 ) ightening torque M = 8.9 Nm (6.56 lb-ft) 8 47 (12.42) 11 (2.91) 40.5 (10.70) 44 (11.62) 292 (77.14) 0.75 (0.20) 31.75 (8.39)

10/12 osch Rexroth Corp. Industrial Hydraulics 3 DRE / 3DREE R 29184/12.02 Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Unit dimensions: types 3DREE and 3DREE... J sea water resistant (dimensions in mm) 15 (3.96) 10 "a" 8.5 (2.26) 69 (18.23) 156.5 [188.5] (41.34 [49.80]) 227 [292] (59.97 [77.14]) Subplates: G 341/01, G 1/4 (SE-4; 7/16-20) G 342/01, G 3/8 (SE-6; 9/16-18) G 502/01, G 1/2 (SE-8; 3/4-16) Valve fixing screws: 4 socket head cap screws M5 x 50 DIN 912 10.9 (10-24 UNC x 2 ) ightening torque M = 8.9 Nm (6.56 lb-ft) 1 Valve housing 2 Name plate 3 roportional solenoid a 4 roportional solenoid b 5 lug-in connector (separate order, see page 5) 7 Identical seal rings for ports,, and 5 42 (11.10) 266 [299] (70.27 [78.99]) 12 2 8.1 "b" 79 (20.87) 3 9 13 7 1 9 4 8.2 31 (8.19) 13.5 (3.57) 40.5 (10.70) 32 32.5 (8.59) 0.01/100 mm 0.0004/4.0 in. (R max 4) Required surface finish of the mating piece 47 (12.42) 8 (2.12) 31 (8.19) 23 (6.08) 15 (3.96) 112.5 (29.72) 47 (12.42) 72 (19.02) 44 (11.62) 292 (77.14) 8.1 rotected hand override N9 8.2 Hand override N for sea water resistant version J Cover for valves with one solenoid (versions or ) 10 Space required to remove the plug-in connector 11 Machined valve mounting face and position of the ports 12 Integrated control electronics 13 Dim. ( ) for sea water resistant version J 11 (2.91) 40.5 (10.70) 0.75 (0.20) 31.75 (8.39)

3 DRE / 3DREE R 29184/12.02 Industrial Hydraulics osch Rexroth Corp. 11/12 Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com hrottle insert When used with a proportional directional valve type 4WRZ, then the following throttle inserts are to be used for ports and : NS 10 16 25 32 52 Ø in mm 1.8 2.0 2.8 Material No. 00158510 00158547 00157948

12/12 osch Rexroth Corp. Industrial Hydraulics 3 DRE / 3DREE R 29184/12.02 Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Notes osch Rexroth Corp. Industrial Hydraulics 2315 City Line Road ethlehem, 18017-2131 US elephone (610) 694-8300 Facsimile (610) 694-8467 www.boschrexroth-us.com his document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of osch Rexroth Corporation. Without their consent it may not be reproduced or given to third parties. he data specifi ed above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. he information given does not release the user from the obligation of own judgment and verifi cation. It must be remembered that our products are subject to a natural process of wear and aging.