Hermetically Sealed Power Contact

Similar documents
LEVEL SWITCH WITH 1 FLOAT

The galvanic separation of the primary or actuating circuit and the load circuits

Miniature circuit breaker Application guide

Note 8. Electric Actuators

Ch 4 Motor Control Devices

SVE135 Sealed High-Voltage Contactor Having High Overcurrent Withstand Capability

KS3 Revision. 8J Magnets and Electromagnets

4.0 OPERATION Type ITH-T Relay

MAGNETIC PROXIMITY SWITCHES

Electrical: Valve monitoring and control circuits

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

The Electromagnet. Electromagnetism

MERCURY CONTACTORS & RELAYS

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

Control Relays Overview

RELAYS. Figure Relay construction.

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

Basic Electrical Parameters of Reed Switch Products

CLASSIFIED 5 MAGNETISM ELECTROMAGNETIC INDUCTION GENERATOR MOTOR - TRANSFORMER. Mr. Hussam Samir

Operating Instructions

The Discussion of this exercise covers the following points:

Relay. for Experiments with the fischertechnik Expansion Kit. Order No

1. Which device creates a current based on the principle of electromagnetic induction?

Magnetism and Electricity ASSIGNMENT EDULABZ. the mere presence of magnet, is called...

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

National 4 Physics - Electricity and Energy Summary Notes

A Practical Guide to Free Energy Devices

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact.

Basic Electrical Parameters of Reed Switch Products

Electro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani

The Basic Reed Switch

BELT-DRIVEN ALTERNATORS

Yaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0.

Is it Magnetic? 1. Fill in each table. List things ATTRACTED by a magnet on the LEFT and things NOT ATTRACTED on the RIGHT.

Solid-State Relays. Solid-State Relays. Features. Description. Overview

CORROSION RESISTANT IN LINE FLOW SWITCHES

Automotive Relays Application Notes. Automotive Applications

BASIC ELECTRICAL MEASUREMENTS By David Navone

Electromagnetic Induction (approx. 1.5 h) (11/9/15)

Magnetic Contactor FJ Series and SK Series Line Expansion

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

ISTEK-C A 750V DC Contactor

Central Battery Systems

Ledex Drive Electronics and Coil Suppressors

2006 MINI Cooper S GENINFO Starting - Overview - MINI

LECTURE 27 SERVO VALVES FREQUENTLY ASKED QUESTIONS

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

Seven Features of the Koganei Vacuum Valve

MOTOR CONTROLLERS. STATE the function of motor controllers.

Question 2: Around the bar magnet draw its magnetic fields. Answer:

INTRODUCTION TO SENSORS, TRANSDUCERS & ACTUATORS

Operation Switches Selector Chart

Lesson 5: Directional Control Valves

Central Battery Systems

UNIT 2. INTRODUCTION TO DC GENERATOR (Part 1) OBJECTIVES. General Objective

Solid-State Relays. Solid-State Relays. Features. Description. Overview

INTRODUCTION Principle

Lab 6: Magnetic Fields

Miniature Liquid Level Sensors

Solid-State Relays. Solid-State Relays. Features. Description. Overview

P. Sub 4 184A404. Sub 3 876A220

Physics12 Unit 8/9 Electromagnetism

Chapter 22: Electric motors and electromagnetic induction

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

Describe an experiment to demonstrate that there is a magnetic field around a current carrying conductor.

7.9.8 Elctromagnetism

Basic Motor Theory. Introduction

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Charles Flynn s Permanent Magnet Motor.

Armature Reaction and Saturation Effect

Voltmeter. for Experiments with the fischertechnik Expansion Kit. Order No

Vacuum pump system type

Exercise 5-1. Primary Resistor Starters EXERCISE OBJECTIVE DISCUSSION. Understand how primary resistor starters operate.

ELECTRICITY: INDUCTORS QUESTIONS

Fuses still the best form of overload protection

1. What type of material can be induced to become a temporary magnet? A) diamagnetic B) ferromagnetic C) monomagnetic D) paramagnetic

C. Figure 1. CA-16 Front View Figure 2. CA-16 Rear View

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1

l Snap-Action Switches

Synchronous Generators I. Spring 2013

[You may download this article at: ]

Handout Activity: HA773

Input, Control and Processing elements

Why Not A Wire? The case for wireless power. Kalyan Siddabattula System Architect bqtesla Wireless Power Solutions TEXAS INSTRUMENTS

MAGNETIC MOTOR STARTERS

MAGNETIC EFFECTS OF ELECTRIC CURRENT

Compact Proportional Solenoid Valve

C627, C628, C631, C656, C657, C658, C671 and C680 Alternator Troubleshooting Guide

MOTOR TERMINAL CONNECTIONS

Al-Saudia Virtual Academy Online Tuition Pakistan Pakistan Online Tutor Magnet and Electromagnetism

Chapter Review USING KEY TERMS UNDERSTANDING KEY IDEAS. Skills Worksheet. Multiple Choice

Installation Sheet January, 2016 Supersedes February, 2013

Bolted contact switches. Pringle switches

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

Adapted from presentation developed by Scott Fausneaucht

Transcription:

Hermetically Sealed Power Contact

What is Bestact? Sealed switches in glass tube with inert gas Q: What is Bestact? A : Briefly, it is a hermetically sealed contact in a glass tube that can be used in circuits up to 240VAC or 230VDC. This means it remains entirely unaffected by external factors such as gas, dust, water and oil, and maintains extremely high reliability and function over a long period of time. We call it "Bestact", our abbreviation for Best Contact". Solenoid Coil Permanent Magnet Q: How does Bestact open and close? A : Just like conventional reed switches, a permanent magnet or solenoid coil is used. Q: How different is it from conventional reed switches in terms of performance? A : The major differences can be summarized as follows; Applicable Voltage Contact Resistance Withstand Voltage Across Contacts Conventional Reed Switches 100VAC max 50VDC max Bestact (R15) Bestact (R25) Max. Continuous Current 0.5A 5A 3A Max. Making Current Max. Breaking Current 100VAC 1A max 100VAC 0.2A (Contact Protection circuit required) 240VAC max 230VDC max 240VAC 30A (cos =0.3 0.4) 240VAC 30A (cos =0.3 0.4) 115VDC 0.6A ( =L/R=100ms) 240VAC max 115VDC max 240VAC 15A (cos =0.3 0.4) 240VAC 15A (cos =0.3 0.4) 115VDC 0.5A ( =L/R=40ms) 100mohms 500mohms max 500mohms max 500VDC 800VAC 500VAC 2

Magnetic and Electrical s of Conventional Reed Switches Magnetic Electrical Q: Is its structure the same as conventional reed switches'? A : No, it is completely different. The basic principle of operation is the same, but the structure is completely different. In conventional reed switches, the current flow path is common with the magnetic flow path. Bestact uses a dual contact structure, consisting of an electrical circuit section and a magnetic circuit section. This unique structure characterizes excellent performance and reliability in Bestact. Magnetic and Electrical s of Bestact Structure of Conventional Reed Switches Structure of Bestact Large-Capacity Type Magnetic Members and Contact Movable Reed Stationary Reed Movable Contact Back Stop Movable Reed Return Spring Inert Gas Glass Tube Stationary Reed Terminal Magnetic Members Stationary Contact Medium-Capacity Type Stationary Reed Movable Contact Back Stop Movable Reed Return Spring Inert Gas Glass Tube Terminal Magnetic Members Stationary Contact 3

Why is Bestact free from contact sticking? Q-1: According to the chart above, Bestact has a large switching capacity, doesn't it? A : That's right. As compared with conventional reed switches, Bestact has approximately hundred times larger switching capacity. But this is not all. Bestact also has the following advantageous features; * Low contact resistance and high stability * Little or no switching surge * Free from sticking even without contact protection circuits * Large DC breaking capacity available * Excellent resistance to vibration and shock Magnetism Electricity Magnetic Electrical Magnetic Electrical Q-2: Why does the dual contact construction provide Bestact with such large capacity? A : Because the optimum materials and mechanism are used in both electrical circuit section and magnetic circuit section. And in design, we gave consideration to contact shape, contact pressure, breaking speed and over current capacity. Q-3: Why is the Bestact free from contact welding and sticking? A : In a word, it is because Bestact has a very large switching capacity. Conventional reed switches have a switching capacity of only around 50VA (resistive) at the most. Consequently they frequently suffer from contact welding - due to the electrostatic storage (capacitive) capacity of long cable runs or contact sticking the inrush current of inductive loads, which is due to insufficient repulsive force when the circuit is closed. That's why conventional reed switches normally need contact protection circuits to prevent these faults. Bestact mechanically charges the return spring and imparts a hammering effect to open the contacts with a large separating force and at high speeds. Made of newly developed heat-resistant material, Bestact will not contact weld or stick, even without contact protection circuitry such as R/C snubbers and diodes, making it possible to use it like a normal contact. Q-4: What is hammering effect? A : It exhibits the function of a bow and arrow. When the armature loses pull force, the movable contact is instantaneously snapped away by the repulsive energy of the armature return spring and stationary contact (contact spring). This helps in breaking small molten contact bridges that often happen in DC circuits. 4 Contact Bridge Arc heat from breaking current causes the coating on the contact to peel off. A whisker-like piece, called a contact bridge, can connect the contacts and keep electricity flowing through them although the circuit is essentially set to open. Contact bridges are mostly invisible to the naked eye.

Is there really no surge or noise? Surge Voltage Contact Open Electrical Noise Equivalent With Bestact Opened Voltage Between Contacts With Bestact Opened Voltage Surge Voltage Glow Voltage Contact Open Surge Voltage Discharge at 400V minimum Bestact Contact Time Q-1: Doesn't Bestact need contact protection circuits even for inductive load circuits? A : Not at all. Contact protection circuits are mainly provided to avoid contact welding from the breaking of inductive load circuits and to control surge voltage. Designed to meet or exceed JEM-1230 solenoid relay standards for control use, Bestact switches break inductive load completely. By restraining surge voltages, Bestact requires no contact protection systems when used within the range of rated current. Q-2: The absence of switching surge helps in preventing noise for electronic circuits, doesn't it? A : Absolutely. Q-3: Why isn't there any switching surge? A : Unlike conventional reed switches, Bestact uses glow discharge before high surge voltages occur, providing operational characteristics that are similar to a circuit with a glow lamp in parallel with the contacts. Although it is not true that Bestact does not produce any surge, it can limit its switching surge smaller than 600V in both AC and DC circuits. Q-4: Does Bestact's good DC breaking performance come from glow discharge? A : Correct. DC inductive loads are normally broken by a long time of arc discharge. This means they normally require contact capacity sufficient to withstand the resulting heat, and a gap between the contacts to remove the arc. Bestact, however, breaks inductive loads while reducing current in the region of the glow discharge. Consequently Bestact switches produce little heat and very low contact damage. A comparison of Bestact and conventional large plug-in relays for DC breaking performance showcases the difference. Bestact has better DC breaking performance than mechanical power relays. Voltage 0 Electricity 0 (a) DC Breaking Characteristics of Bestact Showering Arc Voltage 0 Bestact is stronger than power relays in DC breaking performance RAP-6G Bestact (R15) Bestact (R25) (Yaskawa Product) Rated Continuous Current Rated Operational Current 240VAC(cos =0.3 0.4) 115VDC(L/R=100ms) Electrical Life 8A 5A 3A 3A 0.2A 200,000 times at 115VDC (L/R=100ms) 0.2A 1A 0.5A 300,000 times at 115VDC (L/R=100ms) 0.5A 0.5A 0.3A(L/R=40ms) 300,000 times at 115VDC (L/R=40ms) 0.3A (b) DC Breaking Characteristics of Conventional Power Relays Electricity 0 5

Contact Pressure Conventional Reed Switches Contact Pressure Bestact Ampere Turn Pick-up Ampere Turn Ampere Turn Pick-up Ampere Turn Can it be used for both magnetic control applications and electronic circuits? Q-1: Can it directly open and close DC solenoids? A : Yes, R15 can do it up to about 50VA directly and is the most suitable for valve switches such as DC solenoids. Q-2: Do you mean that Bestact can perform functions of both conventional reed switches and mechanical power relays? A : That's right, but that is not all. By using a single Bestact, the reliability rises significantly; circuit wiring becomes simpler eliminating the need of contact protection circuitry or interposing relays. Q-3: Can Bestact be also used in electronics component circuits? A : Yes it can. Because of the dual contact structure and the wiping effect, it provides excellent reliability for both analog circuits and dry circuits. According to our field failure data, reliability is significantly better than both mercury relays and semiconductor relays. Q-4: So can Bestact be used with circuits at any level? A : It can be used in circuits from 24VDC 1mA up to about 240VAC 1A (inductive load), which makes it ideals as the output contact for controllers. There is no need to worry about load voltage or current levels. Q-5: Why is the contact resistance so low, and performance so stable? A : Contact pressure is fixed, and furthermore the movable contact makes contact by a wiping action. In conventional reed switches, the electrical contact and magnet contact parts are common, so contact pressure changes with magnetic contact. And because it is a simple contact, changes in contact pressure cause large changes in contact resistance. Q-6: How well does Bestact resist against vibration and shock? A : In the weakest axis, 20G against vibration, 40G against shock. Its movable contact, which is small, compared to that of the conventional reed switches, and the spring-assisted return presses it against the glass tube (back stop mechanism) to make it strong against vibration and shock even when non-energized. 6

Operational Characteristics of Bestact Spring load and attractive force Spring force Attractive Force at Drop-out Attractive Force at Pick-up Pick-up Ampere Turn Drop-out Ampere Turn (contact)contact Stroak Q-7: Explain the operating principles of the Bestact. A : Let's take a look at the key points on comparison with conventional reed switches. Contact movement of Bestact when operating when releasing 1 2 3 4 4 3 2 1 When Operating Bestact Conventional Reed Switches Bestact Features Upon closure the ampere turns magnetic (closing) pull force defeats the armature return spring force, causing the armature to move. When the armature is moved, the movable contact defeats the stationary contact spring force, and moves the stationary reed as well. As pull force increases the movable contact defeats the stationary contact spring force, and moves the stationary reed as well. The stationary reed touches the armature. The contact force is determined by the difference between the stationary reed spring force and the return spring force, and is not related to magnetic force. When releasing At the drop-out ampere-turn level the magnetic members break contact. Pull force decreases, and the stationary contact spring force and return spring force combine to return movable contact. Even so, the contact remains closed with a certain degree of pressure. When the stationary contact returns to its rest position the contact opens. At this time, the stationary contact spring force (hammering energy) causes the movable contact to fly off. The armature comes to its rest position inside the glass tube, through the backstop mechanism. Magnetic pull force defeats armature force and moves armature. Contact is common with magnetic part, so there is no movements here. Stationary reed and armature touch, breaking the contact. Contact force varies with magnetic force. At the drop-out ampere turn level, the magnetic members break contact, and the contact is broken at the same time, causing it to gradually leave contact at zero contact pressure. This makes contact sticking. The armature returns to its rest position, but because there is no stop mechanism, it continues to move, which makes sticking and re-striking of the contact possible. Wiping effect Contact force is constant for stable contact resistance. Bestact Conventional Reed Switches Bestact Features Hammering effect Destruction of contact bridges Excellent breaking effect Strong resistance against vibrations and shocks. 7

Hermetically Sealed Power Contact Bestact Q-7: How can Bestact be used? A : It can be used in conjunction with a solenoid relay, the energization of a coil, or limit switches and float switches when used with a permanent magnet. Bestact has excellent resistance to environmental conditions, and because it has large capacity and low contact resistance, it produces low surge and noise. This means it can be used in a wide rang of application from solenoid control circuits to electronic circuits with superb cost performance capabilities. High resistance to vibration and shock Long Wiring Distance Possible No Amplifier Needed DETECTORS Magnetic Proximity Switches Limit Switches Floating Switches Thermo Switches RELAYS Input / Output Relays Multipole Relays Permanent Magnet Solenoid Coils BESTACT Permanent Magnet High Reliability Wide Range of Loads No Contact Protection s Needed CONTROLLERS Push-Button Switches Selector Switches Foot Switches Direct Input for Electronic s Protective ry Simplified YASKAWA CONTROLS CO., LTD. 2-13-1 Nishimiyaichi Yukuhashi-City, Fukuoka, 824-8511 Japan Phone: +81-930-24-4601 Fax: +81-930-24-7131 OVERSEAS SALES DEPT. YASKAWA CONTROLS CO., LTD. REPRESENTATIVE OFFICE EUROPE YASKAWA ELECTRIC AMERICA,AMERICA, INC. 2-13-1 Nishimiyaichi Yukuhashi-City, Fukuoka, 824-8511 Japan Phone: +81-930-24-8635 Fax: +81-930-24-8637 Hauptstraße 185, 65760 Eschborn, Germany Phone: +49-6196/569-322 Fax: +49-6196/569-398 URL: http://www.yaskawa.eu.com E-mail: Yukio.Hara@yaskawa.eu.com Switch Business Group 2121 Norman Drive South Waukegan, IL 60085 U.S.A. Phone: +1-847-887-7206 Fax: +1-847-887-7030 URL: http://www.yaskawa.com/site/home.nsf/home/home.html CHE-C542-7B 2012.9 05-9 0.5WA