DG 023 DG 024 DG 025 DG 041 DG 042. Clogging Indicators

Similar documents
DG 060 DG 061 DG 062 DG 063 DG 064 for Pressure and High Pressure Filters Operating pressure up to 600 bar Response/switching pressure up to 5,0 bar

Clogging Indicators. Description. Page 393. Application Monitoring the contamination of pressure and high pressure filters.

High Pressure Filters Worldline 400 HD 790 HD 990. In-line mounting Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40.

C C C C C C With mounting bolts Bolt thread up to M10 Dipstick length up to 25.2 inch. 70.

D 162 D 232 D 332 In-line mounting Operating pressure up to 63 bar Nominal flow rate up to 350 l/min

High Pressure Filters HD 044 HD 064. Flangeable Operating pressure up to 500 bar Nominal flow rate up to 105 l/min e

Off-line Filters FNS 060. With flow control valve Operating pressure up to 320 bar Nominal flow rate up to 4 l/min e

High Pressure Filter Kits HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40.

Return-Suction Filters E 158 E 198 E 248. Tank top mounting Connection up to -20 SAE Nominal flow rate up to 66 gpm us

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to l/min

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

Return-Suction Filters E 068 E 088. In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min e

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar / 9137 psi Nominal flow rate up to l/min / gpm

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

FNA 045 Operating pressure up to 7 bar / 101 psi Nominal flow rate up to 45 l/min / 12 gpm

E 068 E 088 In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min

FNK 050 FNK 100 Operating pressure up to 10 bar Nominal flow rate up to 125 l/min Cooling capacity up to 45 kw

FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm

HD 049 HD 069 HD 172 HD 319 HD 419 HD 619 Operating pressure up to 630 bar Nominal flow rate up to 450 l/min

FN 060 FN 300 In-line mounting Operating pressure up to 12 bar / 174 psi Nominal flow rate up to 650 l/min / 172 gpm

ES 094 Tank top mounting Connection up to G1¼ Nominal flow rate up to 70 l/min

We produce fluid power solutions. Fluid Management. Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements

Water Absorbing Filter Elements

Line filter with filter element according to DIN 24550

Inline filter with filter element according to DIN 24550

Inline filter with filter element according to DIN 24550

Inline filter with filter element according to DIN 24550

Functional Description

Block mounting filter, for lateral flange-mounting

Cleanline portable. Oil Service Units FA 016 / FAPC 016

Block mounting filter, for lateral flange-mounting

Block mounting filter, lateral flange-mounting possible

Block mounting filter, for vertical flange-mounting

3/2 and 4/2 directional seat valves with solenoid actuation

L L L L Connection up to M60 x 2 Nominal flow rate up to 850 l/min

Block mounting filter, for sandwich plate mounting

SD2E-A3. Functional Description. 3/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2013. Replaces HA /2012

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01.

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Inline filter with filter element according to DIN Type 350LEN0040 to 1000; 350LE0130, 0150

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

Line filter. Features. RE 51400/01.09 Replaces: Types 40/100 LEN 0040 to 0400; 40/100 LE 0003, 0015, 0018

Examples 3/2-way valve A T NO: Symbol

Type 245LEN0040 to 0400; 245LE0130, 0150

High-pressure inline filter, flangeable

RPE2-04. Functional Description HA /2002. Solenoid Operated Directional Valves. Replaces HA /2000

Schmidt Mess- und Regeltechnik

Inline filter. Features RE 51401/ Types 40 FLEN 0160 to 1000; 40 FLE 0045, 0055, 0120 to 0270

Inline filter with filter element according to Bosch Rexroth standard. Type 16 FE Features. Contents

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012

Type 400LDN0040 to 1000; 400LD0130, 0150

Operating Instructions

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Proportional pressure relief valve, directly operated, rising characteristic curve

2/2-way poppet valves with solenoid operation Type KSDER1

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Maintenance Indicators

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

Proportional pressure reducing valve, pilot operated

VJL Functional Description. Ordering Code VJL Spare Parts HA /2002. Logical 3-way check valves. Replaces HA /2001

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Series RFLD Duplex In-Line Filter

Accumulator shut-off block. Type ABZSS. Contents. RE Edition: Replaces: 05.13

Pressure Filter DF...K P, DF...M P, Flange Mounted

CORROSION RESISTANT IN LINE FLOW SWITCHES

RPEW4-06. Functional Description HA /2005. Solenoid Operated Directional Control Valves with Wirebox 1/2 NPT 1/2 NPT. Replaces HA /2004

Type 10TDN0040 to 1000; 10TD2000 and 2500

2.4 HEAVY DUTY SERIES

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2012. Replaces HA /2010

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Reed, Electronic. MOVEMENT > Proximity switches Series CST-CSV-CSH GENERAL DATA

Oil Solutions. Phone Fax Low Pressure Filter Pi 150

Return Line Filter RF

Line filter Pi Features. Nominal pressure 16 bar (230 psi), nominal size 400 up to 6000

2/2-way Solenoid Valve with servo diaphragm

Bourdon tube pressure switch with infinitely variable switching pressure differential

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2014. Replaces HA /2013

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition:

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

FA 016 FAPC 016. Oil Service Units. Description. Page 53

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Proportional flow control valve, with integrated pressure compensator

Safety for Hydraulics

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

External gear motor High Performance AZMB

2/2-way proportional seat valve

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

Input, Control and Processing elements

Inline filter with filter element according to DIN Type 445LEN0040 to Features. Contents. RE Issue: Replaces: 09.

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Thermal flow sensor TFS-35

Transcription:

Clogging Indicators DG 03 DG 04 DG 05 DG 041 DG 04 For Pressure and High Pressure Filters Operating pressure up to 657 psi Response/Switching pressure up to 73 psi 60.30-4us

Description Application Monitoring the contamination of pressure and high pressure filters. General Filter elements installed in hydraulic filters remove dirt from a hydraulic system and therefore become contaminated themselves. Free pores or spaces in the filter material are obstructed by dirt particles, which causes a continuous increase in the pressure loss. Differential pressure [%] Response range of clogging indicator Typical development of dirt accumulation in a filter element during its service life Service life [%] The dirt load collected in a filter element gradually increases during service, which also leads to a higher pressure drop. The resulting differential pressure p is monitored by a clogging indicator. Once a preset value is reached, an electrical and/or optical signal is generated. The following must be observed in this context: The pressure drop caused by the filter element increases depending on the flow rate, the dirt load, and the viscosity of the pressure fluid. Therefore, a filter element is not regarded contaminated before the clogging indicator responds at operating temperature of the hydraulic system, causing a continuous signal. Consequences of an overdue filter element change For filters equipped with a bypass valve: The more dirt has collected in the filter element, the more frequently the bypass valve opens and part of the hydraulic fluid remains unfiltered. The high pressure loss causes unnecessary power consumption. For filters without a bypass valve: The increasing pressure loss across the filter element, which reduces the efficiency of the hydraulic system, eventually causes malfunctions to occur or a pressure relief valve to respond. Design and principle of operation Within the clogging indicator, the differential pressure p = p 1 - p (pressure upstream of the element minus pressure downstream of the element) caused by the filter element acts on a magnetic piston against the force of a spring. In optical (mechanical) clogging indicators, the increasing differential pressure causes the piston to approach a second magnet with reversed polarity which in turn causes the indicator to change from green to red. In electrical clogging indicators, the magnetic piston triggers a reed switch. Special design features Piston seal: Proximity position sensing: The piston actuated by the differential pressure is equipped with a leak-free O-ring seal. As a result, the total flow passes the filter element. Piston movement is detected by sensing a magnetic field, i.e. without mechanical contact. For this reason, ARGO-HYTOS clogging indicators are absolutely leakfree. Characteristics Operating pressure 0... 4570 psi, min. 10 7 pressure cycles Nominal pressure according to DIN 4550 0... 657 psi, min. 10 4 pressure cycles Quasi-static operating pressure Connection For the flange hole layout please refer to the section Dimensions (other fittings on request). Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG, see info-sheet 00.0). Temperature range of fluids - F... + 1 F (short term + 57 F) Ambient temperature range - F... + 176 F Materials Housing: Aluminium alloy Piston: Brass Socket: Polyamide Display piece DG 04: Polyamide Seals: NBR (FKM on request) Operating voltage 10... 30 V DC (only required for clogging indicators with built-in LEDs) Electrical service life Min. 10 7 switching cycles Electrical protection IP 65 (with mounted and secured socket) Mounting position No limitation

Overview of types DG 04 - Optical differential pressure indicator When the preset differential pressure is reached, the optical indicator changes from green to red. If the pressure differential returns to a value below the preset limit, the indicator changes back to green, i.e. no manual reset of the indicator is required. DG 041 - Electrical differential pressure switch (change-over) Option: When the preset differential pressure is reached, the built-in Reed switch changes over. The change-over (CO) switch makes it possible to indicate a broken wire by means of a suitable electronic circuit, as compared to a make contact (normally open NO) switch. The transparent socket with built-in LEDs makes it possible to have an additional optical indication of the filter contamination. When the operating voltage is switched on, a green LED lights up. When the switching pressure is reached, a yellow LED lights up in addition. DG 03 - Electrical differential pressure switch with temperature suppression (change-over) The built-in Reed switch changes over when the preset differential pressure is exceeded. If the temperature drops below 90 F, a temperature switch opens and suppresses the signal of the differential pressure switch. The transparent socket with built-in LEDs makes it possible to have an additional optical indication of the filter contamination (function described at DG 041). DG 04 - Electrical differential pressure switch with switching points (break) Note: When 70 % of the preset differential pressure is reached, the first Reed switch opens, at 100 % the second built-in Reed switch opens. Since the differential pressure of a filter element rises at an exponential rate towards the end of the element s service life (refer to the Description section), approximately 95 % of the service life has expired when the first Reed contact opens (at 70 % of p setting). DG 05 - Electrical differential pressure switch with switching points with/without temperature suppression (change-over) Upon reaching 60 % and 100 % of the preset differential pressure, the two built-in Reed switches change over. Option: In order to suppress the signal at temperatures < 90 F, a temperaturesuppressed version of the differential pressure switch is also available. Accessory: For an additional optical indication of the filter contamination, a socket with 3 built-in LEDs is available with part no. DG 05.601. When the operating voltage is switched on, a green LED lights up. Upon reaching the first switching pressure, a yellow LED lights up in addition. Exceeding the nd switching pressure causes an extra red LED to light up. Note: Refer to DG 04.

Selection Chart Part No. Optical indicator Electrical switch Temp.-suppression < 3 C S 1 Response/Switching pressure S /S 3 Type of contact Switching voltage U Switching current I Switching power P Symbol Weight psi V AC/DC A AC/DC VA/W AC/DC lbs 1 3 4 5 6 7 8 9 10 11 1 DG 04-01 - - 9 - - - - 1 0,37 - DG 04-0 - - 73 - - - - 1 0,37 - Remarks DG 041-61 - - 17 change-over 10/175 0,17/0,5 3,5/5,0 0,4 with socket DG 041-31 - - 9 change-over 10/175 0,17/0,5 3,5/5,0 0,4 with socket DG 041-44 - 9 change-over - /30 - /0,5 - /3,0 3 0,4 with socket DG 041-3 - - 36 change-over 10/175 0,17/0,5 3,5/5,0 0,4 with socket DG 041-33 - - 73 change-over 10/175 0,17/0,5 3,5/5,0 0,4 with socket DG 041-43 - 73 change-over - /30 - /0,5 - /3,0 3 0,4 with socket DG 03-03 9 change-over - /30 - /0,5 - /3,0 4 0,75 with socket DG 03-0 73 change-over - /30 - /0,5 - /3,0 4 0,75 with socket DG 04-0 - - 51/73 break 10/175 0,17/0,5 3,5/5,0 5 0,60 with socket DG 05-05 - - 44/73 change-over 10/175 0,17/0,5 3,5/5,0 6 0,68 without socket DG 05-06 - 44/73 change-over 10/175 0,17/0,5 3,5/5,0 7 0,84 without socket Remarks: The response/switching pressure of the clogging indicator must be lower than the cracking pressure of the bypass valve of the filter. The clogging indicators listed in this chart are standard units. Other designs available on request. Mounting accessories are not included in the scope of delivery and must be ordered separately (Part-no. see spare parts) Reed switches are sensitive of excessively strong currents. Even a short-term overload causes an increased contact resistance or failure of the switch. By taking the following precautions, premature failure of Reed switches due to overload is avoided. Wiring suggestions: Current limiter for DC and AC voltage: If light bulbs or other loads are connected over long distances (conductor capacity!), a protective resistor should be connected in series in order to limit the current. The same applies when capacitance loads are connected. U R C load Spark suppression in DC applications: The contacts of Reed switches open extremely fast, causing voltage peaks to be induced when switching off inductive loads, such as relays, lifting magnets, or solenoid valves. The resulting self-induction currents are short-circuited by connecting a diode in parellel to the inductive load. U load Spark suppression in AC applications: In AC applications, a diode connected in parallel to the load is not sufficient. RC elements should be used here, connected in parallel to the Reed switch. Please contact our design engineers for advice in order to select a suitable RC element. U C R load

Dimensions DG 04 Mounting holes DG 041 Minimum distance from ferromagnetic parts: 0.3 inch Flange hole layout DG 03 / DG 04 Holes p 1 / p p 1 = Higher static pressure p = Lower static pressure DG 05 Recommended threads for mounting on the mating surface Measurements Type A B C D E F G H I K L M N O P Q R S T U DG 04 1.18 1.18 0.85-0.31.64-3.66 0.4 0.18 0.31 0.79 1.54 0.1 1.34 1.73 0.8 0.04 M4 0.4 DG 041 1.18 1.18 0.69-0.43.76 3.7 4.53 0.4 0.18 0.31 0.79 1.54 0.1 1.34 1.85 0.8 0.04 M4 0.4 DG 03 1.18 1.97 - - 0.47.99 3.46 4.76 0.4 0.18 0.31 0.79 1.54 0.1 1.34 1.89 0.8 0.04 M4 0.4 DG 04 1.18 1.38 - - 0.35 3.03 3.50 4.80 0.43 0.18 0.31 0.79 1.54 0.1 1.34 1.77 0.8 0.04 M4 0.4 DG 05-05 1.18 1.38 0.87 1.06 0.35 3.03 3.94 5.47 0.43 0.18 0.31 0.79 1.54 0.1 1.34 1.77 0.8 0.04 M4 0.4 DG 05-06 1.18 1.97 0.87 1.06 0.47 3.03 3.94 5.47 0.4 0.18 0.31 0.79 1.54 0.1 1.34 1.89 0.8 0.04 M4 0.4 Symbols 1 3 4 5 6 7

Spare Parts DG 04 DG 041 / DG 04 DG 041 / DG 03 1a 1b 3 4 1 5 6 Pos. Designation Part No. 1 Mounting accessories * for versions without temperature compensation DG 00.1710 1 Mounting accessories * for versions with temperature compensation DG 00.1730 1a Bolt * M4 x 30 mm 117600 DIN 91-8.8 1a Bolt * M4 x 50 mm 18077800 DIN 91-8.8 1b Spring washer * B4 DIN 17 117700 O-ring 0.18 x 0.06 N007.0041 3 O-ring 0.48 x 0.09 N007.014 4 Display piece assy (with pos. 3) DG 04.1410 5 Socket DG 041.10 DIN 43650 - AF3 6 Socket with LED DG 041.100 DIN 43650 - AF3 7 Socket with 3 LED * DG 05.601 DIN 43651 *Not included in basic unit DG 05 The functions of the complete filters as well as the outstanding features of the filter elements assured by ARGO-HYTOS can only be guaranteed if original ARGO-HYTOS spare parts are used. 7 Quality Assurance Quality management according to DIN EN ISO 9001 Various quality controls during the production process guarantee the leakfree function and solidity of our filters. Our engineers will be glad to advise you in questions concerning filter application, selection as well as the cleanliness class of the filtered medium attainable under practical operating conditions. Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet. We produce fluid power solutions ARGO-HYTOS Inc. P.O. Box 8 Bowling Green, OH 4340 USA Phone: +1-419-353-6070 Fax: +1-419-354-3496 info.us@argo-hytos.com www.argo-hytos.com Subject to change 60.30-4us 0714