EtherNet/IP EtherCAT POWERLINK PROFINET Modbus/TCP

Similar documents
External Pilot Models 5 Sgl. Sol. Plug-In to Left. Internal Pilot Models 1 Sgl. Sol. Plug-In to Left. 4 Dbl. Sol. Plug-In to Right

42 Series MAConnect TM. 42 Series Plug-In Manifold

92 Series MAConnect with Sub D

82 Series MAConnect with Sub-D

Specifications 54 Series Valve

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

MAC VALVES, INC. Rev. T

Direct solenoid and solenoid pilot operated valves

A K 3 E D G

33 SERIES 34 SERIES 34B/C - X X X - G XX X - X XX A - X X X - R XX X - X XX

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

2005 / 2012 / 2035 Series

503 series. GENERAL Operating pressure

Direct solenoid and solenoid pilot operated valves

32, CONTENTS SMALL LARGE

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

PNEUMATIC VALVE MANIFOLDS 11 mm - Series 501 M7 or with push-in fittings Ø6 mm

MAC Pulse Valve PV06 Series

MAC Pulse Valve PV03 Series

Section 2 Proportional Quick Exhaust

FIELDBUS ELECTRONICS 580 Electronics (Series : M7 to 1/2 (G or NPT) or with push-in fittings Ø4 to 10 mm)

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications

Fieldbus System (Output device for driving 5 port solenoid valves)

Direct solenoid and solenoid pilot operated valves

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

Today Numatics is proud to be a part of the Industrial Automation Division of Emerson Electric Co.

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Fieldbus System Variations

Solenoid valves "ENOVA" Series 2300

Action Automation & Controls, Inc.

Introduction Section 1 Section 2 Section 3

Pilot Operated 2 Port Solenoid Valve for Dry Air

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Valve Manifolds. Series Fielbus Electronics - 51

Rubber Seal 5 Port Pilot Type/Body Ported Type. Symbol. How to Order

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

AirLINE and AirLINE Quick electrical/pneumatic Automation System

2012 Series Solenoid Pilot Actuated Valves

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

Control Valve Specifications

Series ITV1000/2000/3000

503 series. Level C to +50 C spool & sleeve metal-to-metal sealing. Aluminium, E-coating treatment

NO: DATE: 04/17/18. Emerson Wholesalers. Unloader Valve Assembly Supplier Changes. Product Supplier Changes

GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77

Pilot Operated 2 Port Solenoid Valve for Dry Air

F5 Valve F6 Valve F7 Valve

HN B G1/US B G2/US B G3

Multipole and Fieldbus

Fieldbus Electronics. G3 Communication Node and I/O 580 Communication Node.

Series RE-46. Valve terminals > Technical details. Order code RE-46/**-*-***-*** Temperature range Medium -10 C C

Pneumatic. PVD Everdure Ceramic Valves

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Valve Products. Valve Products Section D. Valve Products. Catalog PDN1000-3US Parker Pneumatic

ISO 5599/ Series Technical and Operating Data

* Evaluated by TÜV Rheinland (Report No. 968/FSP /16) in accordance with ISO and ISO

3 Port Solenoid Valve Direct Operated Poppet Type

George Fischer Pneumatically Actuated Diaphragm Valve DIASTAR Type 025/028

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Inch Series Overview

Valve terminals MPA-F

Electrical Interface Dimensional Drawings Connector Kits

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Metric Series Overview

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

Single-axis systems Key features

CERAM ISO 5599/1 VALVES PNEUMATIC DIRECTIONAL CONTROL

Linear Motor Series P10-70

J1 Plug Pin Identification

Zone Safety Manifold. Fielbus Electronics Availability, design and specifications are subject to change without notice. All rights reserved.

Manifold Specifications Stacking Type

Modular electrical and pneumatic automation system

5 Port Solenoid Valve Plug Lead Type

2005 Series Solenoid Pilot Actuated Valves

Valve Islands Series H

Manifold Specifications

2035 Series Solenoid Pilot Actuated Valves

Series 1, 2 & 6 Options selector. Port 4 = 1/8" NPT 5 = 1/4" NPT (Series 6* only) 7 = #10-32 UNF 8 = 1/4-28 UNF

Simultaneous Electrical / Pneumatic Connection to Manifold 1/4 or 6mm Integral Push-In Fittings. AC or DC Circuit Board

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

COILS, CONNECTORS, SOLENOID VALVES

J1 Plug Pin Identification

Valvair Sprint TM Pneumatic Valves Solenoid & Pilot-Operated Directional Spool Valves. Catalog VAL-VS-E/USA April 2004

Series 581 ISO Pneumatic Directional Control Valves

503 Series Solenoid Pilot Actuated Valves

J1 Plug Pin Identification

Select from 3 product types and 14 protocols.

Linear gantries Key features

Redundant Control System

Chapter 10: Valves for Pipe Mounting

Three-dimensional gantries

Symbol. Single DS 2120 R2 P R1. How To Order. Body Type 2 : Body Ported Type. Body Option O : Standard

CONTROL. 2 > Control. Solenoid valves Pneumatic valves. Mechanical and manual valves. Flow control valves. Directly operated solenoid valves

Transcription:

We are pleased to announce the release and availability of the MI/O-67 Fieldbus Platform. Our initial release includes several different protocol options in addition to several modules to ensure a complete system package. Below are some of the general features of the platform. MI/O-67 will utilize existing MAConnect technology with MI/O-67 specific part numbers 5 protocols offered for flexibility of different customer systems Digital, Analog and PowerPlus modules to accommodate any I/O or additional valves needed Designed to meet IP67 washdown specifications (with appropriate valve series modifications) The remainder of this bulletin will outline specific details on each module and provide information on ordering for both the MI/O-67 platform and various MAConnect valve series for the initial release. MI/O-67 Communications Module The communications module is the brains of the MI/O-67 platform and will be the minimum required module to implement a fieldbus solution. There will be 5 protocols available upon the initial release: EtherNet/IP EtherCAT POWERLINK PROFINET Modbus/TCP Each communication module will be capable of driving up to 32 solenoids (32 singles, 16 doubles max or any combination of the two up to 32 solenoids) on the MAConnect stack. The module has a capability of outputting 8 A max (0.5 A max per channel) to the MAConnect stack. You can connect up to 12 additional modules to each communication module and have 8A shared across those additional modules. All of the MI/O-67 modules will operate on a 24VDC negative common setup. It will be attached to the MAConnect stack via a valve series specific adapter. The communications modules will be available in both a 7/8 4-pin mini and 7/8 5-pin mini power configuration and will incorporate two Ethernet M12 ports for pass through communication to other network devices. The valve power is brought in on different pins than the electronics power for isolation purposes and both have the capability to handle up to 8A.

In addition to the hardware information laid out above there will be additional software and training tools available for distributor and customer use. These software tools include a digital manual, IP configuration tool and Add On Instructions (AOI) profiles for each module. The associated configuration files (EDS, ESI, etc.) are available on the MAC Valves website. Videos will be posted to the MAC Valves YouTube page to show simple configuration tips and techniques. All modules will attach via binding clip assemblies (4 clips come with each communications module and 2 clips come with each additional module). You will not need to order the clips separately for assembly, except to stock spares. Please note that each MI/O-67 assembly requires an end plate kit (M-M0001-01) and associated MI/O-67 valve series adapter.

MI/O-67 Digital I/O Module The Digital I/O module will help you to differentiate over the competition. While many competitors have digital modules that supply both inputs and outputs in the same module, with the MAC Digital I/O module your customer will be able to change the entire module between NPN and PNP input mode and will also have control over the number of inputs and outputs. The configuration options for I/O include: 0 inputs, 16 outputs 16 inputs, 0 outputs 8 inputs, 8 outputs Each channel will have 2 I/O points per M12 connector and will have fault detection as a standard. Max output will be 0.5A per channel from the shared 8 A electronics power.

MI/O-67 Analog I/O Modules The analog I/O modules will also be available on the initial release of the MI/O-67 platform. Unlike the Digital I/O module, these modules are not configurable. Each Analog I/O module comes set at 4 inputs and 4 outputs (one input and one output per M12 connector). You will also need to take note whether your customer is using 4-20 ma or 0-10VDC analog I/O as they are ordered as two separate modules. Each configuration will also include fault detection.

MI/O-67 PowerPlus Module The PowerPlus module gives you an additional 12 output points at 0.5 A per channel. The setup is similar to the Digital and Analog modules in that there are two outputs per M12 connector. The PowerPlus module requires you to bring in up to an additional 6 A of independent power via a 7/8 5-pin mini power connector to power these additional outputs for valves and other devices. MI/O-67 MAConnect Series There will be three different MAConnect series adapters available initially which are the 36/46, 42 and 92 series. In the past with smaller MAConnect series you were limited to 16 solenoids; with the release of the MI/O-67 MAConnect series part numbering, you can now order up to 32 solenoid outputs as a standard (only 32 solenoid output boards will be available on MI/O-67 MAConnect series). Please note that on the new 36/46 and 42 series MAConnect bases there is a limitation of 26 solenoids that may be energized at a given time if you are using 5.4W coils. Additional releases will be sent out as new adapters are developed. As with previous MAConnect series releases, bases can be wired for single or double solenoid and you will need to order these as such. Note that a single solenoid valve placed on a base wired for double solenoid will consume two outputs.

36/46 Series 1 2 3 4 5 BOM for Above Stack: 1. (1) M-M0001-01 End-Plate Kit for MI/O-67 2. (1) MIO67A-CM-EN-01 MI/O-67 EtherNet/IP Communications Module 3. (1) M-46019-01 46 Series MI/O-67 MAConnect Interface Adapter 4. (16) 46A-LMA-1C-JDAP-1FA 46 Series Valves with MI/O-67 Bases 5. (1) M-46018-01-16 46 Series MAConnect End-Plate Kit

42 Series 1 2 3 4 5 BOM for Above Stack: 1. (1) M-M0001-01 End-Plate Kit for MI/O-67 2. (1) MIO67A-CM-EN-01 MI/O-67 EtherNet/IP Communications Module 3. (1) M-42023-01-08 42 Series MI/O-67 MAConnect Interface Adapter 4. (7) 42A-AMA-D11-GDAP-1DJ 42 Series Middle Station Valves with MI/O-67 Bases 5. (1) 42A-AMA-D31-GDAP-1DJ 42 Series End Station Valve with MI/O-67 Base

92 Series 1 2 3 4 5 6 BOM for Above Stack: 1. (1) M-M0001-01 End-Plate Kit for MI/O-67 2. (1) MIO67A-DG-01-01 MI/O-67 Digital I/O Module 3. (1) MIO67A-CM-EN-01 MI/O-67 EtherNet/IP Communications Module 4. (1) M-92048-01-06 92 Series MI/O-67 MAConnect Interface Adapter 5. (5) 92B-BAB-B1K-DM-DDAP-1DM 92 Series Middle Station Valves with MI/O-67 Bases 6. (1) 92B-BAB-B3K-DM-DDAP-1DM 92 Series End Station Valve with MI/O-67 Base

92 Series Loaded Stack 1 2 3 4 5 6 7 8 9 BOM for Above Stack: 1. (1) M-M0001-01 End-Plate Kit for MI/O-67 2. (1) MIO67A-DG-01-01 MI/O-67 Digital I/O Module 3. (1) MIO67A-PP-01-01 MI/O-67 PowerPlus Module 4. (1) MIO67A-AN-01-01 MI/O-67 0-10 VDC Analog I/O Module 5. (1) MIO67A-AN-02-01 MI/O-67 4-20 ma Analog I/O Module 6. (1) MIO67A-CM-EN-01 MI/O-67 EtherNet/IP Communications Module 7. (1) M-92048-01-06 92 Series MI/O-67 MAConnect Interface Adapter 8. (5) 92B-BAB-B1K-DM-DDAP-1DM 92 Series Middle Station Valves with MI/O-67 Bases 9. (1) 92B-BAB-B3K-DM-DDAP-1DM 92 Series End Station Valve with MI/O-67 Base

How To Order MI/O-67 Module MIO67A - CM - XX - XX Protocol EN EtherNet/IP EC EtherCAT PL POWERLINK PN PROFINET MB MODBUS/TCP Power Connector 01 7/8 5 Pin Power Connector 02 7/8 4 Pin Power Connector Additional Modules MIO67A-DG-01-01 MIO67A-AN-01-01 MIO67A-AN-02-01 MIO67A-PP-01-01 M-M0001-01 N-M0001 Configurable Digital I/O 0-10 VDC Analog I/O 4-20 ma Analog I/O Power Plus End Plate Assembly Binding Clip Assembly

How To Order 92 Series MAConnect for MI/O-67 92B - X X X - X X X - DX - D XX X - X XX Pilot Valve Valve Function 0 Base Only A Sgl Sol Sgl Pressure B Dbl Sol Sgl Pressure C Sgl Sol Dual Pressure D Dbl Sol Dual Pressure E Dbl Sol 3 Pos Closed Center F Dbl Sol 3 Pos Open Center G Dbl Sol 3 Pos Press Center H Dbl Sol 3 Pos Dual Press Press Cen J Dbl Sol 3 Pos Dual Press Close Cen K Dbl Sol 3 Pos Dual Press Open Cen L Sgl Sol Sgl Press w/mem Spring N Sgl Sol Dual Press w/mem Spring Body Type and Exhaust Options 0 Base Only A Plug-In Std Exh C* Plug-In w/pilot Exh to Main Exhaust *Must use DU Pilot Body Body Electrical Options 0 Base Only A No Light in Top B F Light in Top Suppression Diode, Blocking Diode & Light Note: MI/O-67 Modules Are Always On The Left With The Stack To The Right And Cylinder Ports Facing You. Port Size and Thread Type B 1/4 NPTF C 3/8 NPTF E 1/4 BSPPL F 3/8 BSPPL H 1/4 BSPTR J 3/8 BSPTR Order Example 1 M-M0001-01 MI/O-67 End Plate Assembly 1 MIO67A-CM-EN-01 MI/O-67 EtherNet/IP 1 M-92048-01-07 Interface Adapter (Int Pilot, NPT Threads, For 7 Valves) Assembly 6 92B-AAB-C1J-DM-DDAP-1DM 6 Middle Station Valves, Sgl Sol, Light In Top, Int Pilot, Side Cyl, 3.8 NPTF 1 92B-AAB-C3J-DM-DDAP-1DM 1 End Station Valve, Sgl Sol, Light In Top, Int Pilot, Side Cyl, 3/8 NPTF Manifold Configuration 1 Side Cyl. Ports (Middle Station) 2 Bottom Cyl. Ports (Middle Station) 3 Side Cyl. Ports (End Station) 4 Bottom Cyl. Ports (End Station) 5 Side Cyl. Ports- Selector Manifold (Middle Station) Int/Ext Pilot MAConnect Plug-In for MI/O-67 Internal Pilot J Sgl. Solenoid Plug-In (32 Outputs) K Dbl. Solenoid Plug-In (32 Outputs) External Pilot S Sgl. Solenoid Plug-In (32 Outputs) T Dbl. Solenoid Plug-In (32 Outputs)

How To Order MI/O-67 92 Series Pilot Valve DX - D XX P - X XX DM DP DU Pilot Style Muffled Exhaust Piped Exhaust Pilot Exhaust Out Main Exhaust Voltage DA 24 VDC (5.4W) FB 24 VDC (1.8W) FF 24 VDC (2.4W) P Valve/Base Connector Plug-In Manual Operator 0 No Operator 1 Recessed Non-Locking 2 Recessed Locking 3 Non-Locking Extended 4 Locking Extended Electrical Connector DM Plug-In DN Plug-In w/ Diode How To Order MI/O-67 Interface Adapter for 92 Series M - 92048 - XX - XX X Pilot 01 Internal Pilot 02 External Pilot Stations 01 Adapter As Individual Part 02 thru 32 Number Of Stations If Factory Gang Blank P T Threads NPTF Threads BSPPL Threads BSPTR Threads

How To Order 36 Series MAConnect for MI/O-67 36A - X X X - X X - J XX P - X XX Body Type 0 Base Only J Base Mount Body Universal Valve N.C. K Base Mount Body Universal Valve N.O. L Base Mount Body N.C. Only Valve Port Size and Electrical Type M MAConnect 0 Valve only Thread Type A 1/8 NPT C 1/8 BSPPL E 1/8 BSPTR F 5/32 O.D. Tube Receptacle Base Electrical 1 Plug-In (32 Outputs) Manifold Configuration E N.C. Man Side Cyl. Port F N.O. Man Side Cyl. Port G N.C. Man Bot Cyl. Port & Reg w/ Slotted Stem H N.O. Man Bot Cyl. Port & Reg w/ Slotted Stem J N.C. Man Bot Cyl. Port & Reg w/ Adjusting Knob K N.O. Man Bot Cyl. Port & Reg w/ Adjusting Knob S N.C. Man Bot Cyl. Port & Reg w/ Locking Stem T N.O. Man Bot Cyl. Port & Reg w/ Locking Stem Voltage DA* 24 VDC (5.4w) Max Cv = 0.3 DC 24 VDC (2.4w) DE 24 VDC (1.8w) MA* 24 VDC (5.4w) Max Cv = 0.23 *A Maximum Of 26 Solenoids Can Be Energized At The Same Time When Using a 5.4w Coil. Valve / Base Connector P Plug-In Manual Operator 0 No Operator 1 Recessed Non-Locking 2 Recessed Locking 3 Extended Non-Locking 4 Extended Locking Electrical Connector Base Plug-In Base Plug-In w/ Diode Base Plug-In w/ LED Base Plug-In w/ Diode and LED Note: MI/O-67 Modules Are Always On The Left With The Stack To The Right And Cylinder Ports Facing You. FA FB FD FE Order Example 1 M-00001-01 MI/O-67 End Plate 1 MIO67A-CM-EN-01 MI/O-67 EtherNet/IP 1 M-46019-01 MI/O-67 Interface Adapter w/ NPTF Ports 6 36A-JMA-1E-JDAP-FA 6 Middle Station Valves, Normally Closed Universal w/ Normally Closed Manifold And NPTF Ports 1 M-46018-01-06 End Plate Assembly w/ NPTF Ports For 6 Valves

How To Order MI/O-67 End Plate Kit for 36 Series M - 46018 - XX - XX X Ports 01 Standard Inlet and Exhaust Ports (1/4 ) Number of Stations 01 Adapter As Individual Part 02 thru 32 Number Of Stations If Factory Gang Blank P T Threads NPTF Threads BSPPL Threads BSPTR Threads How To Order MI/O-67 Interface Adapter for 36 Series M - 46019 - XX X Ports 01 Standard Inlet and Exhaust Ports (1/4 ) Blank P T Threads NPTF Threads BSPPL Threads BSPTR Threads

How To Order 46 Series MAConnect for MI/O-67 46A - X X X - X X - J XX P - X XX Body Type Electrical Type Port Size and 0 Base only Thread Type L Base mount body M MAConnect 0 Valve only M Base mount body w/ gauge port A 1/8 NPT N* Base mount body double solenoid C 1/8 BSPPL P* Base mount body double solenoid E 1/8 BSPTR w/ gauge port F *Must Order 5.4W (Voltage Code) For Double Solenoids 5/32 O.D. Tube Receptacle Base Electrical 1 Sgl Sol Plug-In (32 Outputs) 2 Dbl Sol Plug-In (32 Outputs) Manifold Configuration Voltage Valve / Base Manual Operator Electrical Connector DA* 24 VDC (5.4w) Connector 0 No Operator FA Base Plug-In C Side Cylinder Ports Max Cv = 0.3 P Plug-In 1 Recessed Non-locking FB Base Plug-In w/ Diode D Side Cylinder Ports w / Flow Controls DC 24 VDC (2.4w) 2 Recessed Locking FD Base Plug-In w/ LED E Bottom Cylinder Ports w/ Reg. (Slotted Stem) DE 24 VDC (1.8w) 3 Extended Non-Locking FE Base Plug-In w/ Diode and LED F Bottom Cylinder Ports w/ Reg. (Slotted Stem) & Flow Controls DJ 24 VDC (1.3w) 4 Extended Locking G Bottom Cylinder Ports w/ Reg. (Locking Slotted Stem) MA* 24 VDC (5.4w) H Bottom Cylinder Ports w/ Reg. (Locking Slotted Stem) & Flow Controls Max Cv = 0.23 J Bottom Cylinder Ports w/ Reg. (adjusting knob) *A Maximum Of 26 Solenoids Can Be Energized K Bottom Cylinder Ports w/ Reg. (adjusting knob) & flow controls At The Same Time When Using a 5.4w Coil. L Bottom Cylinder Ports M Bottom Cylinder Ports w/flow controls Note: MI/O-67 Modules Are Always On The Left With The Stack To The Right And Cylinder Ports Facing You. Order Example 1 M-00001-01 MI/O-67 End Plate 1 MIO67A-CM-EN-01 MI/O-67 EtherNet/IP 1 M-46019-01 MI/O-67 Interface Adapter w/ NPTF Ports 6 46A-LMA-1C-JDAP-FA 6 Middle Station Valves, w/ 32 Outputs And NPTF Ports 1 M-46018-01-06 End Plate Assembly w/ NPTF Ports For 6 Valves

How To Order MI/O-67 End Plate Kit for 46 Series M - 46018 - XX - XX X Ports 01 Standard Inlet and Exhaust Ports (1/4 ) Number of Stations 01 Adapter As Individual Part 02 thru 32 Number Of Stations If Factory Gang Blank P T Threads NPTF Threads BSPPL Threads BSPTR Threads How To Order MI/O-67 Interface Adapter for 46 Series M - 46019 - XX X Ports 01 Standard Inlet and Exhaust Ports (1/4 ) Blank P T Threads NPTF Threads BSPPL Threads BSPTR Threads

How To Order 42 Series MAConnect for MI/O-67 42A - X X X - X X X - GXXP - X XX Solenoid Assembly Valve Function 0 Base Only A 2 Position Sgl Press Sgl Solenoid B 2 Position Sgl Press Dbl Solenoid C 2 Position Dual Press Sgl Solenoid D 2 Position Dual Press Dbl Solenoid E 3 Position Closed Center F 3 Position Open Center H 3 Position Dual Press Press Center R 2 Position Sgl Solenoid Universal S 2 Position Dual Solenoid Universal Pilot Exhaust Options 0 Base Only M Pilot Exh Muffled P Pilot Exh Piped #10-32 R Pilot Exh Piped M5 U Pilot Exh Out Main Exh Internal / External Pilot And Body Plug-In 0 Base Only Single Solenoid A Int Pilot Sgl Press B Int Pilot Dual Press (From #3) C Int Pilot Dual Press (From #5) D Ext Pilot From Base Double Solenoid E Int Pilot Sgl Press w/ LED F Int Pilot Dual Press (From #3) w/ LED G Int Pilot Dual Press (From #5) w/ LED H Ext Pilot From Base w/ LED J Int Pilot Sgl Press w/ LED and Diode K Int Pilot Dual Press (From #3) w/ LED and Diode L Int Pilot Dual Press (From #5) w/ LED and Diode M Ext Pilot From Base w/ LED and Diode Port Size and Thread Type A #10-32 B M5 (NPTF thru ports) D 6mm O.D. Tube Receptacle (NPTF thru ports) E 1/4 O.D. Tube Receptacle (NPTF thru ports) F M7 (NPTF thru ports) G M5 (BSPPL thru ports) J 6mm O.D. Tube Receptacle (BSPPL thru ports) K 1/4 O.D. Tube Receptacle (BSPPL thru ports) L M7 (BSPPL thru ports) M M5 (BSPTR thru ports) P 6mm O.D. Tube Receptacle (BSPTR thru ports) R 1/4 O.D. Tube Receptacle (BSPTR thru ports) S M7 (BSPTR thru ports) Note: MI/O-67 Modules Are Always On The Left With The Stack To The Right And Cylinder Ports Facing You. Order Example 1 M-00001-01 MI/O-67 End Plate 1 MIO67A-CM-EN-01 MI/O-67 EtherNet/IP 1 M-42023-01-06 MI/O-67 Interface Adapter, 6 Stations w/ NPTF Ports 5 42A-AMA-A11-GDAP-1DJ 5 Middle Station Valves w/ #10-32 Ports 1 42A-AMA-A31-GDAP-1DJ End Station Valve w/ NPTF Threads And #10-32 Cylinder Ports Manifold Configuration 1 Side Cyl. Ports (Middle Station) 2 Bottom Cyl. Ports (Middle Station) 3 Side Cyl. Ports (End Station) 4 Bottom Cyl. Ports(End Station) Int/Ext Pilot MAConnect Plug-In for MI/O-67 1 Int Pilot Sgl. Solenoid Plug-In (32 Outputs) 2 Int. Pilot Dbl. Solenoid Plug-In (32 Outputs) 5 Ext. Pilot Sgl. Solenoid Plug-In (32 Outputs) 6 Ext. Pilot Dbl. Solenoid Plug-In (32 Outputs)

How To Order MI/O-67 42 Series Solenoid Assembly G XX P - X XX DA DC DD DF Voltage 24 VDC (1.0W) (N/A For Dbl Sol) 24 VDC (1.8W) 24 VDC (2.5W) 24 VDC (4.0W) Note: A Maximum Of 26 Solenoids Can Be Energized At The Same Time When Using a 5.4w Coil. P Valve/Base Connector Plug-In Manual Operator 1 Recessed Non Locking 2 Recessed Locking 3 Extended Non Locking 4 Extended Locking Electrical Connector DJ Base/Manifold Plug-In DP Base/Manifold Plug-In w/ LED Light DR Base/Manifold Plug-In w/ Suppression Diode DS Base/Manifold Plug-In w/ Suppression Diode And LED Light FB Base/Manifold Plug-In (For Double Solenoid 2 And 3 Position Valves) How To Order MI/O-67 Interface Adapter for 42 Series M - 42023 - XX - XX X Pilot 01 Internal Pilot 02 External Pilot Stations 01 Adapter As Individual Part 02 thru 32 Number Of Stations If Factory Gang Blank P T Threads NPTF Threads BSPPL Threads BSPTR Threads