Serial adapter 1.0 V10 Fadec to serial comunications

Similar documents
Electric Landing Gear controller P14

FADEC system - Autostart 06

Glow Plug for E Series Only

Issue 2.0 December EPAS Midi User Manual EPAS35

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

Turbine engine user manual. ATJ SV series turbine

EV Display V4 User Guide

V 2.0. Version 9 PC. Setup Guide. Revised:

Note: If anything is damaged or missing, contact your customer representative immediately.

EPAS Desktop Pro Software User Manual

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Rotel RSP-1570 RS232 HEX Protocol

Product Manual. Part Number: MVP-193 Mefi-6 ECU Revision: 1.0

80W. Operating Manual. Dual Power. Intelligent Balance Charger LiPo/LiFe/LiIon: NiMH/NiCd: Pb: Charge Power: Charge Rate: Discharge Rate:

OVERVIEW OF CONTROLS

Quick Setup Guide. WARNING! Connect this product to an AC power source whose voltage is within the range specified on the product's nameplate.

Cannondale Diagnostic Tool Manual

Warning! Before continuing further, please ensure that you have NOT mounted the propellers on the MultiRotor.

USERS MANUAL MCD REMOTE OPERATOR

T100 Vector Impedance Analyzer. timestechnology.com.hk. User Manual Ver. 1.1

ALM-Inline. Accurate Lambda Meter V1.1.2 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED.

TYPE 5867 PORTABLE Q METER

SPD DEVICE USER MANUAL V1.2.

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Rotel RSX-1065 RS232 HEX Protocol

Rotel RSX-1055 RS232 HEX Protocol

Informer Compact Series

SP PRO ABB Managed AC Coupling

Operators Manual. FHX Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 07/2017

or, with the time and date option enabled using the CommFlags command:

USER MANUAL W ONBOARD GENERATOR SYSTEM

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

PURCHASE AGREEMENT, FULL ASSUMPTION OF LIABILITY AND INDEMNITY AGREEMENT

CP Data Sheet I-CAM Introduction: I-CAM, Integrated Calibration And Automated Mapping CP Engineering Systems Ltd.

Rotel RSX-1067 RS232 HEX Protocol

HMM Series Mechanical Heat Meters

GENERAL LINK-Module 2.4GHz

Harris IRT Enterprises Digital Resistance Tester Model XP

Installing a Programmed Fronius SCERT in a Managed AC Coupled system

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

BAYLAN AUTOMATED TEST BENCH

Table of Contents 1. INTRODUCTION GENERAL INFORMATION-ABOUT OBDII/EOBD PRODUCT DESCRIPTIONS OPERATIONS...11

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Instruction of connection and programming of the VECTOR controller

Important instructions

RDM Isolator. Product Information. Hans Juergen Buhr Cologne, June e:cue lighting control - An OSRAM Company

Holden VZ 3.6L ECU & Powertrain Interface Module Linking Instructions

MATRIX LLC LEVEL CONTROL PANEL

Description of the AMT Netherlands Olympus HP gas turbine.

BRAKE TESTER DECELEROMETER

Quick Installation Guide for X50 Plus Car OBD Multi-function instrument Product introductions

ZT-USB Series User Manual

Redbird Insight User Guide

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

PRX-5A-HV. Operating manual. Stabilised receiver power supply. PRX-5A-HV Power for Receiver - High Voltage. Order No. 4176

Mercury HP gas-turbine. January 2008

Where There is Miboxer There is Power. User Manual. Model No.: C2-6000

Acu-Trac Ultrasonic Fuel Level Transmitters

SP5 INSTALLATION AND SETUP MANUAL

FasDiag JD101 Code Reader. User Manual. OBDII Car Diagnostic Scanner

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

(The following instructions are an excerpt from the Record CG3 User Guide) 4.5 Setting up the CG3 OBDII Interface

Revel Robotic Manipulator User Guide

Wallbox Commander. User Guide WBCM-UG-002-EN 1/11

RDS. For Windows TORSION SPRING CALCULATOR For ROLLING DOORS Version 4 REFERENCE MANUAL

Begin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A

2016

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

Hi-Z USB Wireless. Introduction/Welcome

DA 35/70 EFI MIL SPEC

Lamp kit. Installation manual SIM 7 series R

SZT system for temperatures measuring in bins and silos

PROGRAMMING MANUAL ZeelProg PDCI-20V

Merlin M70XBL-100XBL-140XBL-166TS-200XBL Instruction Manual (Version 1.4/2018)

REVISION DESCRIPTION:

SentryGOLD Fully-Automated Fuel Management System

Lithium Power Supply

FALCON ELECTRIC, INC.

Operating Instructions. bluesmart Active

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

DIGITAL TORQUE GAUGE MODEL BTGE-G

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Operating instructions

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

Liquid Turbine Flow Meter OwnerÊs Manual

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

RS232. CAN. Integration with Tachograph Continental VDO DTCO

Table of contents. THE RADIO Operation & functions 18 Additional switch channel 18 Switch off automatic cool down 19

Pectel T2 ECU Technical documentation Release 1.00 INTRODUCTION

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

Dispense interface converter NA-8 (RS-485/RS-232 to non-addressable RS-422/RS-485/RS-232 and backwards)

Sabertooth 2x50 User s Guide

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

Installation Instructions for: Channel Thermocouple Amplifier

PowerView PV380-R2 Mechanical Configuration

Ahi template for Taranis and Horus. Setup Guide

Model H30 Operation Manual

X11CA-IM MASTER MODULE

Transcription:

Serial adapter 1.0 V10 Fadec to serial comunications Users Guide. Torrent d en Puig, 31. 08358, Arenys de Munt, Barcelona,Catalonia,Spain E-mail: info@xicoy.com. Fax: +34 933 969 743 web: www.xicoy.com Xicoy WEEE register number: ES004749 Copyright 2014, Xicoy Electronica SL. All Rights Reserved Manual contents & design: Gaspar Espiell. V1.0

Welcome! Congratulations on the purchase of your new adapter. Xicoy are dedicated to the design and production of electronic controllers to the highest standards of quality and reliability to bring you the customer the very latest next generation designs. Features: The Xicoy serial adapter provides the protocol translation between the data from the engine collected by the different Xicoy Fadec turbine controllers (from model 107K) and JetsMunt specific controllers which use different proprietary protocols to a standard asynchronous protocol to allow the data to be collected and used in other systems like test bench setups on universities. Electrical connections: The adapter connects to the ecu trough the supplied 3 wire patch lead, and it is powered by the ecu. On the other side of the adapter there is a RJ12 connector of which 3 pins are used, TX, RX and ground. Ground is the same as the ecu and engine ground; take this fact in to account on industrial installations to avoid ground loops. Signal levels are of 3,3V TTL. Under request Xicoy Electronica can supply a 3 wire lead installed in place of the RJ12 connector, or a RS232 compliant lead. The adapter has 2 small LED lights to show its working status, one green and one red. The green led blinks to confirm that there is traffic from ecu to adapter, and the red led blinks to signal the traffic from the adapter to the external device.

BASIC SETUP: The list of measures and commands available in the current software release are described in the protocol section. If the adaptor is going to be used in a flight vehicle and on this application is necessary to have the information of fuel flow and remaining tank capacity, due that several fadec models don t support these measures, the adapter itself can calculate these values from the data retrieved from the fadec, plus a couple of parameters to be programmed on the adapter. This programming is only necessary if you plan to use the fuel flow and tank capacity information. The programming procedure is: Connect the data terminal to the fadec port on the telemetry adapter trough a Y servo lead. Connect a battery (4 to 8V) on the other port of the lead to power both devices. Connect the battery last, after both devices are already connected. The RED led on the adapter will lit, and the data terminal will display Tank capacity: using +/- buttons set the tank capacity on your model in milliliters. (1Oz=29,6ml)

Pump factor: The unit calculates the fuel used from the pump power supplied the fadec. Different pump models move different amounts of fuel at same voltage, so this factor should be set to suit your particular engine+pump+installation. At moment of writing we don t have a table of values for the different engines on the market. The recommended calibration process is: 1) Enter the fuel capacity of your plane in the tank capacity menu. Leave the pump factor at the default 400 unit, unless you know a more accurate figure for your engine model. 2) Do a normal flight; use your usual timer to determine the length of the flight. Ignore on this flight the % of fuel in the tank displayed by the telemetry on landing. 3) After landing, before to shut down the receiver, check the % of remaining fuel displayed on the telemetry screen. 4) Measure the real quantity of fuel left. If you use a regular shape tank (cylindrical, square, etc) them you can measure the height of the remain fuel in respect to total capacity of the tank. 5) Once you know the % displayed on the radio and the real % of fuel in the tank, you can calculate the correct pump factor in your plane. Example: You have set a pump factor of 400. After the flight you see that telemetry show a remaining fuel quantity of 18%. Then you measure the tank, and you have a tank of 20cm long of a regular shape and the fuel that remain arrive to 5cm height of the total of 20cm. Your remaining fuel is 5/20*100= 25% The indicated fuel as per telemetry is 18% The error is 18/25= 0,72. Then, the new pump factor should be 400 x 0,72= 288

Serial interface protocol and electrical connections: Electrical: Pin 1 is the TX pin, pin 6 is the RX pin, and pin 5 is ground. Do not connect anything else on other pins, these pins are connected directly to CPU and can damage it. Nominal electrical levels are of 3,3V. Rx input is tolerant to 5V inputs. TX output always will output a 3,3V signal. Serial interface settings: baud rate: 9600 data bits: 8 parity: none stop bits: 1 Protocol description: Data is retrieved from the adapter trough different commands. See table. Note that the adapter is continuously retrieving the data from the fadec, but due at the nature of the fadec protocols and speed data speed used on different fadec models, there are 3 types of informations available that differ in the refresh rate. High speed: Updated 10 times/second, like RPM, EGT, Pump power Medium speed: Updated each 2 seconds. Slow speed: Updated once each 60 seconds Command structure: SYNC, COMMAND, CR Where: SYNC: First byte. Always C7h value (Decimal 199) COMMAND: 3 byte command in ASCII. See table. CR: Last byte. 0Dh value (Decimal 13) After sending a command, the adapter will return the answer for this particular command, see the table.

Example: To retrieve the data displayed on the LCD screen of the fadec. The command is RSD. Then the command would be: C7h 2Ch 52h 53h 44h 2Ch 0Dh C7h -> Sync 52h -> R 53h -> S 44h -> D 0Dh -> CR, last byte. The ecu will return two strings. First, a copy of the command received, followed by the data requested In the above example, it will return: The command received: C7h, RSD, 0Dh C7h->Sync byte Payload in ASCII TrimLow EGT 20CRpm 50.000Pw=124 0Dh -> CR, last byte.

Command Meaning Answer (Payload) Update rate Adapter version Fadec models RSD Read Screen Data ASCII text 32 byte F All All RCV Read Current Values RPM, EGT in ºC, Pump Power, Voltage of Battery, Throttle % F All All WDU Data Up Command OK. -> Send to the fadec a keypress on the + button - All All WDD Data Down Command OK. -> Send to the fadec a keypress on the - button - All All WMU Menu Up Command OK. -> Send to the fadec a keypress on the ^ button - All All WMD Menu Down Command OK. -> Send to the fadec a keypress on the. button - All All RAV Read Adapter version ASCII version number (ex: 1.0) F All All REL Read Engine Limits Full Power RPM, Idle RPM, Max EGT, Pump Limit, Tank Size ml S All All Disposal Electrical equipment marked with the cancelled waste bin symbol must not be discarded in the standard household waste; instead it must be taken to a suitable specialist disposal system. In the countries of the EU (European Union) electrical equipment must not be discarded via the normal domestic refuse system (WEEE - Waste of Electrical and Electronic Equipment,directive 2002/96/EG). You can take unwanted equipment to your nearest local authority waste collection point or recycling centre. There the equipment will be disposed of correctly and at no cost to you. By returning your unwanted equipment you can make an important contribution to the protection of the environment.