Accessories & spare parts - pressure transmitters

Similar documents
Condensed Catalog 2006 North America

Pressure transmitters for industrial applications Type MBS 4510

Heavy duty pressure switch MBC 5000 and MBC 5100

Pressure transmitter for industrial applications Type MBS 4510

Pressure transmitters for heavy duty applications Type MBS 3250

Pressure transmitter for industrial applications Type MBS 4500

Pressure transmitters for heavy duty applications MBS 3200 and 3250

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Pressure measurement PP20H Fully welded hygienic pressure sensor with flush membrane

Pressure transmitter for marine applications Type MBS 5100 and MBS 5150

Pressure Transmitters

Pressure transmitter for marine applications MBS 3100 and MBS 3150

Core Industrial Products for Distributors and Wholesalers in North America

SATRON VTe pressure transmitter

Pressure switch and Thermostat Type CAS

Pressure Transmitter JUMO dtrans p30 Type

MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Pressure transmitter for marine applications MBS 33M

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

INSTRUMENTATION & CONTROL

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Data sheet Pressure controls and thermostats type CAS August 2000 DKACT.PD.P10.B B0616

Electronic Pressure Switches

JUMO MIDAS S05 Pressure transmitter Type

Pressure and temperature controls, Type CAS

Flow measurement FlexFlow PF20H Hygienic flow sensor

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

Electronic Pressure Switches

Easy. Core Industrial Products for Distributors and Wholesalers. selection of future proof products. iasupport.danfoss.com

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Pressure transmitter for elevated media temperatures

Pressure transmitter for air and water applications Type MBS 1900

Temperature sensor TE2

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Figure 1: WPR2 Dimensions and Hardware

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210A DKACV.PD.100.A B1023. August 2001

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210B. February 2002 DKACV.PD.200.A B1504

OEM Pressure Transmitters

CombiTemp Temperature Measuring System

Dissolved Oxygen Measurement System with Air Blast Cleaner

Pressure transducer DMU 01K Compact version

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Paddle-wheel flow controller for On/Off control

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Solenoid valves 3/2-way direct-operated Type EV310A

Solenoid valves 2/2-way servo operated type EV220B 15 50

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

One. The performance of your wind turbine relies on the quality of its small components. ia.danfoss.com. Brochure Mobile Hydraulic

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Electronic Pressure Switches

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 1 and CTM 2 Liquid Ejector

Float Switch AKS 38. Technical brochure MAKING MODERN LIVING POSSIBLE

Type A-10 General Purpose Pressure Transmitters

Liquid level switch Type AKS 38

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Screw-in resistance thermometers with plug connector

Pressostats and thermostats CAS

SITRANS P measuring instruments for pressure

mass flowmeter for compressed air

mass flowmeter for compressed air

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Marine Pressure ECTN Applications. Features

Industrial Pressure Transmitters

Assisted lift operated 2/2-way solenoid valves Type EV250B

2/2-way assisted lift operated solenoid valve type EV250B

Solenoid valve Types EV220B 15 - EV220B 50

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Servo-operated 2/2-way solenoid valves Type EV220A

Adjustment range. Seal material. Pressure connection

INSERTION flow sensor for continuous flow measurement

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Differential Pressure Sensors

CONTROLLERS & SPECIAL VALVES

SonoMeter 30 Energy Meters

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Pressure Transmitter for wind turbine applications MBS 8200 and MBS 8250

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Level Measurement Point level measurement - RF Capacitance switches

Solenoid valve Types EV220B 15 - EV220B 50

Solenoid valves, 2/2-way servo-operated type EV220B 6-22

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Pressure Transmitter JUMO dtrans p30 Type

Paddle-wheel flow controller for On/Off control

- Quicktemp TP62/TW39...T500 -

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Transcription:

Accessories & spare parts - pressure transmitters Connection adapters - for pressure transmitters Type Code No Pack Size Weight Conn. std. Application Accessory bag 060-333266 20 0.06 ISO 228-1 KPS / CAS Accessory 060G0252 6 0.11 - MBS G 1/2 Welding nipple 060G2501 60 0.21 - MBS 4510 Accessory 060G2505 45 0.21 DIN 11851 Dairy DN 40 MBS 4510 Accessory 060G2506 20 0.42 DIN 11851 Dairy DN 50 MBS 4510 Accessory 060G2502 45 0.16 Clamp ISO 2852 G1 1/2 MBS 4510 Accessory 060G2510 24 0.37 Clamp ISO 2852 G 2 MBS 4510 Accessory 060G2503 45 0.19 SMS 1145 G 1 1/2 MBS 4510 Damping coils - for pressure transmitters Type Code No Pack Size Weight Conn. type Conn. size Conn. std. Capillary tube length Prot. tube mat. Application [mm] Armoured damping coil 060-333366 15 0.22 Pipe thread G 3 /8 A ISO 228-1 1.000 mm - CAS Damping coil 060-016966 14 0.20 Pipe thread G 1 /2 A ISO 228-1 1.000 mm Stainless steel MP Damping coil 060-104766 25 0.17 Pipe thread G 3 /8 A ISO 228-1 1.500 mm - CAS / KP Plug-in displays - for pressure transmitters Type Code No Pack Size Weight Description Electrical connection MBD 1000 060G2850 23 0.11 Plug-in display unit MBD EN 175301-803 MBV 2000 isolation valves - for pressure transmitters The MBV 2000 isolation valve is designed for mounting between a Danfoss pressure transmitter and fluid-filled systems and offers a fast and efficient method of connection and removal. The isolation valve automatically closes when a pressure transmitter is removed, so transmitters can be changed easily without having to first drain a system. The valve re-opens when a transmitter is connected. The valve meets demands for fast installation, simple and effective isolation and easy connection. Operating pressure: Up to 600 bar Burst pressure: 1500 bar Temperature: -20 C to 200 C Wetted parts: All metal parts in contact with medium DIN 17440-1.4404 (AISI 316L) Gasket: Viton Designed to fit between Danfoss pressure transmitters and fluid-filled systems and offers a fast and efficient method of connection and removal of Danfoss products Type Code No Pack Size Weight Ext. connection Width across flats Max. working pressure Max. burst pressure Operating temp. [mm] [bar] [bar] [ C] MBV 2000 061B6001 60 0.11 G 1 /4 A DIN3852E 24 mm 600,0 bar 1500 bar -20-200 C MBV 2000 061B6002 60 0.11 G 1 /2 A DIN3852E 30 mm 600,0 bar 1500 bar -20-200 C MBV 2000 061B6003 60 0.12 G 1 /2 A DIN3852E 30 mm 600,0 bar 1500 bar -20-200 C

Plug-in display, type MBD 1000 for pressure/temperature transmitters with output 4-20 ma Introduction A microprocessor controlled plug-in display that can be universally applied to all MBS, AKS and MBT transmitters with a 4-20 ma output and DIN 43650 plug. The MBD 1000 is simply inserted between the transmitter and its connector by means of the integral DIN cubic plug adaptor. Measurement range, decimal point and filtering can be comfortably adjusted with 3 push-button keys after removal of the front cover. The display provides a simple and effective solution for local monitoring of pressure and temperature. Features Polarity protected No auxiliary energy source required Can be tilted to any position High accuracy and minimal temperature drift Easy installation Instant monitoring of transmitter CE approved Technical data Input signal 4-20 ma (2-wire) Max. allowed input current 40 ma Reverse voltage protection polarized installation Voltage drop approx. 3 V Display 10 mm high LCD-display Display range start and end value freely programmable Maximum display value 9999 Minimum display valaue -1999 Decimal point any position Measuring accuracy 0.2% ± 1 digit Temperature drift 100 ppm / C Measuring interval approx. 3 measurements / sec. Filtering selectable in 3 stages Nominal temperature 25 C Ambient temperature 0 to 50 C Humidity 0 to 80% RH (non condensing) Electromagnetic compatibility additional error Housing Dimensions Connection IP rating according to EN61000-6-2 and EN61000-6-3 < 1% ABS. Front screen made of polycarbonate 48.5 x 48.5 x 35.5 mm (L x W x D) DIN 43650 adaptor IP65 Ordering Type MBD 1000 Code no. 060G2850 IC.PD.P20.B1.02-520B1814

Plug-in display, type MBD for pressure/ temperature transmitters with output 4-20 ma Electrical connection Pin assignment of 4-pin adaptor plug according to DIN 43650 Pin 1 Supply + 2 Supply 3 NC Connection to transmitter housing Dimensions Assembled view MBS/AKS/MBT Transmitter connector DIN 43650 IC.PD.P20.B1.02-520B1814 Danfoss A/S 08-2003 DE-BD

MBV 5000 test valves - for MBS and MBC The MBV 5000 is a part of a block concept covering block pressure switches, block pressure transmitters, block test valves and accessories. The block concept has been developed to save space, weight, and costs and meet the strict demands on marine equipment, including EU stipulations on such products. MBV 5000 is designed in many different configurations for use in many different marine applications, for example: Monitoring, alarm indication, shut-down, diagnosing on equipment such as motors, gears, thrusters, pumps, filters, compressors, etc. The block valve meets demands for fast installation, simple isolation, and easy test pressure connection. The MBV block valves designed in many configurations are for use with the MBC pressure switch or the MBS block pressure transmitter within the marine industry The valve meets demands for fast installation, simple isolation and easy test pressure connection Type Code No Pack Size Weight Inputs Outputs Ball valves Pressure conn. Test pressure conn. Test function MBV 5000 061B7000 15 0.43 1 1 1 G 1 /4 DIN3852-E M16 x 2 Separate MBV 5000 061B7001 18 0.87 2 2 2 G 1 /4 DIN3852-E M16 x 2 Separate MBV 5000 061B7002 12 1.32 3 3 3 G 1 /4 DIN3852-E M16 x 2 Separate MBV 5000 061B7005 18 0.86 1 2 2 G 1 /4 DIN3852-E M16 x 2 Separate MBV 5000 061B7006 12 1.31 1 3 3 G 1 /4 DIN3852-E M16 x 2 Separate MBV 5000 061B7009 18 0.79 1 2 1 G 1 /4 DIN3852-E M16 x 2 Common MBV 5000 061B7010 12 1.12 1 3 1 G 1 /4 DIN3852-E M16 x 2 Common Miscellaneous accessories & spare parts - for MBV Type Code No Pack Size Weight Conn. size Conn. std. Conn. type Application Adaptor 061B720601 70 0.11 G 1 /4 ISO 228-1 Pipe thread MBV 5000 Adaptor 061B720201 70 0.11 G 1 /8 ISO 228-1 Pipe thread MBV 5000 Miscellaneous accessories & spare parts - for pressure transmitters Type Code No Pack Size Weight El. conn. Conn. std. PLUG 060G1034 8 0.39 Plug with 5 meter cable (EN 145301-803) DIN 43650-A PLUG 060G0007 8 0.03 Pg 11 plug (EN 145301-803) - PLUG 060G0005 8 0.06 Pg 13.5 plug (EN 145301-803) DIN 43650 PLUG 060G0008 8 0.03 Pg 9 plug (EN 145301-803) -

MBV 2000 Isolation Valve Introduction The MBV 2000 isolation valve is designed for mounting between Danfoss pressure transmitters with DIN 3852 - E pressure connection and fluid-filled systems and offers a fast and efficient method of connection and removal. The isolation valve automatically closes when a transmitter is removed, so transmitters can be changed easily without having to first drain a system. The valve reopens when a transmitter is connected. The valve meets demands for fast installation, simple and effective isolation and easy connection. MBV 2000 Transmitter mounted with valve Technical data Performance Pressure: Operating pressure: Up to 600 bar. Burst pressure: 1500 bar. Temperature: Operating temperature: 20 C to 200 C Materials Wetted parts: All metal parts in contact with the medium: DIN 17440-1.4404 (AISI 316 L) Gasket: Viton System medium: The valve is impervious to fuel oil, oil, water and air. It is not recommended for use with petroleum, combustible gasses or corrosive chemicals. Mounting Packaging: Isolation valves are supplied with two plastic protective covers which should be removed prior to use. Locking/fixing: For safety, it is essential that the isolation valve is thoroughly secured to the system prior to connecting/disconnecting a transmitter. The valve must not become loose when a transmitter is being removed. Fitting & removal: It is recommended to remove or fit transmitters at a system pressure below 40 bar. September 2001 Danfoss A/S 09-2001 DKACT.PD.P15.A2.02 520B1054

MBV 2000 Isolation Valve Application note: The MBV 2000 must only be used to connect Danfoss transmitters with a pressure connection in compliance to DIN-3852-E. Specification and code numbers for standard types A B C D E Code no. Type G¼ DIN 3852 G¼A DIN 3852-E 17.5 mm 29.4 mm 24 061B6001 MBV 2000-111 G¼ DIN 3852 G½A DIN 3852-E 15.4 mm 29.4 mm 30 061B6002 MBV 2000-123 G½ DIN 3852 G½A DIN 3852-E 20.4 mm 34.4 mm 30 061B6003 MBV 2000-223 G¼ DIN 3852 ¼-18 NPT DIN 3866-A 16.4 mm 29.4 mm 24 061B6004 MBV 2000-131 Ordering of special versions Type no: MBV 2000- X X X Female thread: G¼ DIN 3852... 1 G½* DIN 3852... 2 Others... X Male thread: G¼ DIN 3852-E... 1 G½* DIN 3852-E... 2 ¼-18 NPT DIN 3866-A... 3 Others... X Width across flats: E 24... 1 E 27... 2 E 30... 3 Others... X * E 27 & E 30 only Ordering of special versions will impose an additional cost and extended delivery times. Minimum order quantity: 12 parts. 2 DKACT.PD.P15.A2.02 Danfoss A/S 09-2001(AC-TMP/mr)

Pressure test valve MBV 5000 Danfoss block components The block concept has been developed to save space, weight, and costs. The product is intended for use in many applications, for example: monitoring, alarm indication, shut-down, diagnosing on equipment such as motors, gears, thrusters, pumps, filters, compressors, etc. The range contains block pressure controls, block pressure transmitters, block test valves and accessories. The concept meets the strict demands on marine equipment, including EU stipulations on such products. Block valve MBV 5000 MBV 5000 is a block valve designed in many different configurations for use in the marine industry. The valve meets demands for fast installation, simple isolation, and easy test pressure connection. Advantages Compact design Light material Many configuration possibilities Low installation costs Fast and easy to operate Dimensions Test valve Outputs 1 2 3 4 5 L 1 36 mm 76 mm 116 mm 156 mm 196 mm Adapters Angleway Straightway Cover adapter adapter August 2000 DKACT.PD.P15.B1.02 520B0383

Pressure test valve MBV 5000 Technical data Performance Pressure Temperature Mechanical Material Pressure connection Overload pressure 180 bar Burst pressure 250 bar Operating pressure 0 to 120 bar Operating temperature 20 to 120 C Ambient temperature 20 to 120 C Temperature of medium 20 to 120 C Housing Anodized AIMgSi1 Nipple AIMgSi1 Ball 1.4571 Gasket PEEK/FPM Input G 1 /4 Output Flange / M5 8 Specification and code numbers for standard types Test pressure connection Shut-off valve Pressure connection: G 1 4. Test pressure connection: M16 2 Symbol Output Input Output Input Output Input Type Output Weight Length Height Width no. kg mm mm mm Type no. Code no. 1 0.4 36 80 40 MBV5000-1111 061B7000 2 0.8 76 80 40 MBV5000-1211 061B7001 1 3 1.2 116 80 40 MBV5000-1311 061B7002 4 1.6 156 80 40 MBV5000-1411 061B7003 5 2.0 196 80 40 MBV5000-1511 061B7004 2 3 2 0.8 76 80 40 MBV5000-2211 061B7005 3 1.2 116 80 40 MBV5000-2311 061B7006 4 1.6 156 80 40 MBV5000-2411 061B7007 5 2.0 196 80 40 MBV5000-2511 061B7008 2 0.7 76 80 40 MBV5000-3211 061B7009 3 1.0 116 80 40 MBV5000-3311 061B7010 4 1.3 156 80 40 MBV5000-3411 061B7011 5 1.6 196 80 40 MBV5000-3511 061B7012 Code numbers for standard flange G 1 8 adapters Description Cover Angleway adapter Straightway adapter Code no. 061B7200 061B7201 061B7202 Ordering special versions Type no: MBV 5000- x x x x Type Separate inputs and separate test functions 1 1 G 1 / 4 Common input and separate test functions 2 2 M10 1 Common input and common test function 3 x Other Other X Pressure connection Number of outputs (n) Test pressure connection 1 Output (only for type 1) 1 0 Hole plug G 1 /4 2 Outputs 2 1 Pressure gauge connection M16 2 3 Outputs 3 X Other 4 Outputs 4 5 Outputs 5 Other X 2 DKACT.PD.P15.B1.02 Danfoss A/S AG-SP.ER 08-2000 CCB