Fan coil units MAJOR 2 CV/CH

Similar documents
MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

Carisma The Ultra Quiet Fan Coil

CENTRIFUGAL FAN COIL UNIT VCE

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

Innovative, High Performance, Quiet Units.

Air-Cooled Liquid Chiller with integrated hydraulic module

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Total cooling capacity kw Total heating capacity kw Features

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

BRIZA 22 HYBRID HEATING & COOLING

42N. Room Fan Coils PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Simpified installation & large options choice

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension

TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY. 1.5 kw kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation. Low Energy Consumption

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

SysCoil 2. Fan Coil Units Models SVC, SVN, SHC, SHN to 8.75kW to 4.90kW. 94 to /h

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

Highline 260i EC Waterside Fan Coil Unit

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

Features: Available in horizontal and vertical units

Technical Catalogue. Cassette Fan Coils Climmy Comfort 3

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

Cubic unit cooler. SKB semi-industrial range

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

Cubic unit cooler. SKB semi-industrial range

AHN 064 to 304 EHN/CHN 064 to 304

TECHNICAL MANUAL SOFFIO Ducted units

something new in the air Technical Bulletin

Carisma CRC. Range includes 9 air rates (from 105 to 1500 m 3 /h) It is the most comprehensive range, perfectly suited to meet

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes. Use. Range. Design

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation

Address: VTS Clima L.L.C.

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT

BRIZA Brochure UK 2013

Fan coil unit NBS 100/150

Alfa Laval Optigo CS. Commercial air coolers - Slim line

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

Heat Exchangers. Evaporator Catalogue

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

High Static Pressure Duct Fan Coil Unit

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide

BASTONE (dual) fancoil Units

EURUS / EURUS-I. Conditioning your ambient, maximising your comfort.

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

FCVC Series VERTICAL FAN COILS

BRIZA Super slim and powerful heating, cooling

Water terminals From 360 to 1598 m 3 /h. From 1.3 to 9.6 kw. SysQuare. Chilled water cassettes. From 1.1 to 14.0 kw

Product Brochure Fan coil units for suspended ceilings HyPower-Geko. Energy efficient Powerful Hygienic Low noise

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

The World Leading Air-conditioning Company

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

Fan Coil Units. Technical Data. Flexi type unit ECDEN FWD-AT/AF

Sentinel D-Box Twin Fan

FS Fan-Coil Units Hi-Rise, Vertical

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

Everest XV. ErP. High Efficiency HRV Fan Unit READY

CM3-6 A-R-G-E-AQQE C-A-A-N

IDENTIFICATION ACCESSORIES DESCRIPTION

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

Ocelot vertical fan coil unit

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

CLIMA-ZONE TERMINAL UNIT FOR HEATING AND COOLING MULTIPLE ROOMS. Ductable EC system, by constant pressure zones

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

DIRECT-AIR ILB / ILT Series Rectangular duct fans

KLIMA Active Chilled Beams

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

CornerAir. CornerAir. Active chilled beam

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

DXP 100 Air Cooled Condenser

ACOUSTIC CABINET FANS CVB / CVT Series

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Transcription:

CH 41 D CV 1 D MAJOR 2: Design and performance HEE impeller for increased performance Motor optional MAJOR 2 is a non-independant chilled and/or hot water supplied air conditioning Comfort unit for the heating and cooling of offices and hotels. With reduced dimensions and designed to ease maintenance interventions, MAJOR 2 adapts to all types of architecture. MAJOR 2 provides the user with thermal comfort thanks to a high performance compact coil and ensures a particulary low acoustic level. MAJOR 2 CASED UNITS ARE AVAILABLE : - either as Vertical cased (CV1D) - or Horizontal cased (CH41D). MAJOR 2 stands out from other fan coil units by its harmonious lines combining aesthetism and advanced technology. RANGE The range comprises 6 sizes spanning cooling capacity from 0.8 to 8 kw. MAJOR 2 has 7 operating speeds, three of which are prewired in the factory. In the standard version, the fan motor assembly speeds and auxiliary electric heaters (in 2-pipe + 2-wire version) are available on a terminal block without control panel. MAJOR 2 is easy to use, and benefits from improved management of comfort and expenditure thanks to several levels of CIATmounted electronic regulation systems (available options): - MAJOR 2 with V30 electronic control. - MAJOR 2 with V200 electronic control. - MAJOR 2 with V2000 electronic control. - MAJOR 2 with V3000 electronic control. In this configuration, simply connect the water and electricity and immediately feel the benefits of the MAJOR 2 unit. * see Comfort unit controls page CIAT takes part in the EUROVENT fan coil unit certification programme See performances in Eurovent mode, on last page of the range. The list of products and certified characteristics is given in the EUROVENT directory and on the web site www.eurovent-certification.com 1

TECHNICAL DESCRIPTION Casing Plain white RAL 9010 colour. Flanges, hatches and discharge grille in self-extinguishing polymer. Two hatches giving access, without dismantling the casing, to the air vent and to the control terminal (accessory). Front face and chevron in pre-enamalled sheet metal. Monobloc intake grille in perforated sheet metal. Water coil (2 or 4-pipe system) New concept of high performance compact coil, with a new geometry fin. Galvanised sheet metal. Copper tubes, continuous fins in aluminium. Hydraulic connectors of coil piping with 40 mm between axis. Connections on the left (or right for NCH) of the unit, facing the discharge. Air vent and drain integrated into coils. Nominal pressure: 16 bar (at 20 C). Test pressure 24 Bar. Max water temperature: 110 C (PN 10). Electrical battery (2-pipe + electric system) 230/1/50 monotube electrical elements inserted in the aluminium block. 22 capillary-tube temperature limiters with manual and automatic reset inserted in the aluminium housing. Condensates drain pan External reinforced insulation in the standard version. Auxiliary drain pan (CH41D) for valve condensates recovery Reclined to avoid water retention. Diam. 16 mm discharge. CONTROLS Range of wall-mounted electromechanical thermostats V30 and V200 electronic range. Fan motor assembly Motor 7 speeds, 3 of which pre-wired in factory (possibility of modifying this wiring on site). Enclosed type, tropicalised, with protected shaft. Permanent capacitor. Ball-bearings. Automatic thermal protector with standard opening on the coil. Resilient mounts. Electrical supply 230/1/50. Reduced electrical consumption. Fan(s) Galvanised sheet metal casing. HEE impeller(s) with forward-curved dynamically balanced blades and dual inlets. V0 fire rating. Air filter Positioned on the fan coil intake. Flexible filtering media in polyester fiber, renewable. Efficiency Class EN 779 : G3. Fire resistance: M1. Support frame Mounting holes on the rear panel to facilitate its fixation to the wall. Rear panel in galvanized sheet metal. Two PC flanges loaded with glass fiber (for increased resistance). Electrical box Integrated to the right flange of the frame. Electrical connection terminal box on DIN railing as per EN 50022-7.5 mm depth. Cables stops for customer's connection. Note: Refer to installation brochures for futher information. V2000 and V3000 communicating electronic range. LON control, consult us. ACCESSORIES Rubber 90 elbow for condensates outlet from underneath the unit. Support feet to pass piping along the sides. Rear support for passage of 55 or 70 mm thick and 110 mm max high skirting board. Condensate drain pump (CH 41 D). Touching-up pen for paintwork. OPTIONS (CONSULT US) - 60Hz operation (230V) - Energy saving High Energy Efficiency (HEE) motor (High Energy Efficiency) 2

DIMENSIONS CV 1D - CH 41 D Vertical cased model CV 1 D Discharge outlet Hatch for access to air vent Hatch for access to control system Captive attachment screw Inlet grille + filter Recess for skirting board (max. 110 x 15 mm) Horizontal cased model CH 41 D MAJOR 2 CV 1 D / CH 41 D A B C 426 N 740 243 24 428 N 940 243 28 430 N 1140 243 36 580 432 N 1340 243 42 434 N 1540 243 50 435 N 1540 243 50 Mass kg Dimensional drawing 5976194 3

FASTENING POINTS AND PASSAGE OF POWER SUPPLY CV 1D -CH 41 D D (Between mounting holes) E (Between mounting holes) Detail of mounting hole FLOOR or WALL Pre-cut access holes to be punched out to pass pipes through rear of unit (Ø 50mm) Condensate drain pan Condensates drain (CV1D model (Ø16 mm) Two holes Ø 60 mm for passage of electrical power connections, with membrane seal. WALL or CEILING c f Condensate drain CH41D model (Ø16 mm) Pre-cut holes for pipes (or insulated flexible connections Ø 37-44 or 49 mm) c f Heating coil connections Cooling coil connections MAJOR 2 CV 1 D / CH 41 D D E F G H I J K L M N O P Q 426 N 623 428 N 823 430 N 1023 432 N 1223 270 160 90 70 60 103.5 200 153.5 102 200 104 154 40 434 N 1423 435 N 1423 4

CONNECTIONS AND PASSAGE OF POWER SUPPLY (2 OR 4-PIPE) A R = 580 B A View A-A DN10 AG V W S T U A U 2-way valve (optional) Double insulated sleeve A-B A hot water coil B cold water coil (4-pipe system) (2-pipe system) X Y AH 200 Z Support feet and pipe cover (accessories) Rear support for skirting board passage (accessory) AE AA AB AC AD Sealing plate pipe cover Support foot (protective cap to be removed) for passing the pipes from the right or left of the unit AF Available space 70 x 110 MAJOR 2 CV 1 D / CH 41 D 426 N 428 N 430 N 432 N 434 N 435 N S T U V W X Y Z AA AB AC AD AE AF AG AH 37 114 40 269 258 48 64 245 110 90 164 202 55 110 187 132 5

A B Fan coil units HYDRAULIC CONNECTIONS EXAMPLES CV 1 D with connectors underneath CV 1 D with connectors at rear Air vent Water coil Double insulated sleeve Hot water valve (4-pipe system) Cold water valve (2-pipe system) Inlet grille with G3 filter Insulated flexible connections with elbow piece Standard insulated flexible connections Auxiliary condensates drain pan with pre-cut holes for passage of 3 sizes of insulated flexible connections (Ø 37,44,48) Elbowed condensate drain hoses (accessory) 30 mini CV 1 D with connectors underneath CH 41 D with connectors at rear Ø 16 mm Condensates drain Horizontal auxiliary condensates drain pan PN16 AB Fan motor assembly G 3/8 or 1/2 Rc 3/8 or 1/2 Conical gas type G 1/2 or 3/4 Cylindrical gas type Gasket Copper pipe Ø 15.87 mm Double sleeve 2 part M/F 3/8 to 1/2 or 1/2 to 3/4 adapter (accessory not supplied as standard) 4-way G 1/2 to 3/4 valve (included with control option) Assembly details for valve + 2-part connector +double sleeve A PN16 B AB Note : The assemblies above are presented as examples with valves fitted (optional) and insulated flexible connections (not supplied as standard). 6

TECHNICAL CHARACTERISTICS Pipe diameter at outlets (tapped fittings) The diameters of the female tapped fittings on coil connection pipes are standardised (see above drawing dimension T). 2- pipe sytem 4- pipe sytem Standard unit MAJOR 2 426 N 428 N 430 N 432 N 434 N 435 N Heating or cooling coil 3/8 " 3/8 " 3/8 " 3/8 " 1/2" 1/2 " Cooling coil 3/8 " 3/8 " 3/8 " 3/8 " 1/2 " 1/2 " Heating coil 3/8 " 3/8 " 3/8 " 3/8 " 3/8 " 3/8 " T2 DN10 Unit with valve (optional) Diameters of valve outlets (threaded connections) The diameters of the valves male threaded connections are standardised (see above drawing dimension T2). MAJOR 2 426 N 428 N 430 N 432 N 434 N 435 N Heating or cooling 2- pipe sytem 1/2 " 1/2 " 1/2 " 1/2 " 3/4" 3/4" coil Cooling coil 1/2 " 1/2 " 1/2 " 1/2 " 3/4" 3/4" 4- pipe sytem Heating coil 1/2 " 1/2 " 1/2 " 1/2 " 1/2 " 1/2 " For units fitted with customer control valves, an intermediate two-part male/female connector is needed between the coil connector and the valve(s). This connector is available as an accessory (1, 2 or 4 connectors are required depending on the configuration (2 or 4-pipe) and the valve type (2-way or 4-way) - consult us). When a CIAT valve-based control system is used, the two-part connector is integrated in the control loop. Heater / cooler content (in litres) 2- pipe sytem 4- pipe sytem MAJOR 2 426 N 428 N 430 N 432 N 434 N 435 N Heating or cooling coil 0.53 0.76 0.99 1.32 1.58 1.58 Cooling coil 0.53 0.76 0.99 1.32 1.58 1.58 Heating coil 0.13 0.13 0.25 0.20 0.24 0.24 Electrical characteristics of motors (230/1/50) MAJOR 2 Input power (W) Input current (A) Motor ref 426 N 428 N 430 N 432 N 434 N 435 N R1 77 100 110 113 143 159 R2 64 85 92 92 127 139 R3 54 71 76 76 113 120 R4 45 60 64 62 102 105 R5 40 54 57 56 90 95 R6 35 49 51 50 81 85 R7 31 45 46 45 74 76 R1 0.33 0.43 0.48 0.49 0.62 0.69 R2 0.28 0.37 0.40 0.40 0.55 0.60 R3 0.23 0.31 0.33 0.33 0.49 0.52 R4 0.19 0.26 0.28 0.27 0.44 0.46 R5 0.17 0.23 0.25 0.24 0.39 0.41 R6 0.15 0.21 0.22 0.22 0.35 0.37 R7 0.13 0.20 0.20 0.20 0.32 0.33 7

THERMAL PERFORMANCES Cold water temp.: 7 / 12 C, summer air temp.: 27 C 50 % RH - Hot water temp.: 90 / 70 C, winter air temp.: 19 C. MAJOR 2 CV1D CH41D 426 N 428 N 430 N 432 N 434 N 435 N Motor ref Air flow rate Heating capacity of 2-tube system coil W Cooling capacity W Heating capacity of 4-tube system coil W Comfort level (ISO or NR) Average temperature rise in air (K) (2) Auxiliary electric heater 230 / 1 / 50 m3/h Total Sensible 1 R 2R R1 450 6 770 2 840 2 150 3 930 45 4.0 7.9 R2 410 6 280 2 600 1 960 3 740 43 4.3 8.7 R3 365 5 650 2 470 1 800 3 480 39 4.9 9.8 R4 310 4 910 2 240 1 590 3 160 34 600 5.7 1 200 11.5 R5 235 3 850 1 720 1 220 2 660 27 7.6 15.2 R6 165 2 820 1 340 917 2 100 19 10.8 21.6 R7 105 1 790 812 563 1 460 <15 17.0 33.9 R1 685 10 000 4 120 3 160 5 600 45 3.5 6.9 R2 620 9 270 3 730 2 820 5 320 41 3.8 7.7 R3 505 7 780 3 410 2 500 4 720 38 4.7 9.4 R4 420 6 600 2 900 2 100 4 200 33 800 5.7 1 600 11.3 R5 335 5 440 2 540 1 780 3 660 28 7.1 14.2 R6 265 4 360 1 990 1 390 3 110 21 9.0 17.9 R7 210 3 540 1 580 1 110 2 650 <15 11.3 22.6 R1 845 13 900 5 280 3 960 7 760 45 4.2 8.4 R2 730 12 200 4 600 3 380 7 120 41 4.9 9.8 R3 605 10 400 4 140 3 010 6 380 37 5.9 11.8 R4 495 8 700 3 380 2 440 5 630 32 1 200 7.2 2 400 14.4 R5 405 7 220 2 910 2 070 4 910 26 8.8 17.6 R6 310 5 640 2 130 1 530 4 080 18 11.5 23.0 R7 220 4 110 1 490 1 100 3 180 <15 16.2 32.4 R1 940 15 100 5 710 4 190 5 970 41 4.4 8.8 R2 805 13 400 5 280 3 790 5 440 37 5.2 10.3 R3 660 11 400 4 560 3 210 4 830 32 6.3 12.6 R4 530 8 980 3 810 2 710 4 200 27 1 400 7.8 2 800 15.7 R5 430 7 290 3 050 2 180 3 640 22 9.7 19.3 R6 325 5 170 2 140 1 520 2 970 <15 12.8 25.6 R7 240 3 630 1 500 1 120 2 360 <15 17.3 34.7 R1 1295 20 200 7 720 5 800 7 690 45 4.6 9.2 R2 1180 18 700 7 000 5 210 7 300 43 5.0 10.1 R3 1050 16 900 6 670 4 910 6 820 40 5.7 11.3 R4 905 14 800 5 770 4 160 6 240 36 2 000 6.6 4 000 13.1 R5 765 12 800 5 240 3 770 5 620 33 7.8 15.5 R6 615 10 600 4 380 3 110 4 890 28 9.7 19.3 R7 475 8 360 3 210 2 320 4 110 23 12.5 25.0 R1 1370 21 200 7 880 5 990 7 940 46 4.3 8.7 R2 1280 20 000 7 600 5 690 7 650 44 4.6 9.3 R3 1155 18 300 7 190 5 310 7 210 42 5.1 10.3 R4 1020 16 500 6 280 4 530 6 720 38 2 000 5.8 4 000 11.6 R5 875 14 400 5 820 4 230 6 110 35 6.8 13.6 R6 730 12 300 4 920 3 510 5 460 29 8.1 16.3 R7 580 10 000 4 020 2 910 4 690 24 10.2 20.5 Table with acoustic attenuation of room and facility of 12 db for MAJOR 2 CV1D and CH41D models 426 N to 430 N and 14 db for models 432 N and 435 N. (1) Please note, the air discharge temperature must not exceed 65 C. (CIAT recommendation). Standard factory wiring 8

PRICE LIST (EXCLUSIVE OF V.A.T.) Basic unit with fan motor assembly and electric heaters (if required) connected to terminal block, without speed control, equipped with a Eurovent G3 class filter. CV 1 D CH 41 D MAJOR 2 CASED MODEL 426 N 428 N 430 N 432 N 434 N 435 N 426 N 428 N 430 N 432 N 434 N 435 N 2- pipe system (2) STANDARD UNIT (FAN assembly wired on block) Water coil only Left sockets 4- pipe system Code 7063569 7063581 Water coil + electric heaters Left sockets 2- pipe + 2 wire system (1) 1 electric heater 2 electric heaters 600 W 7063593 1200 W 7063605 Code 7063570 7063582 800 W 7063594 1600 W 7063606 Code 7063571 7063583 1200 W 7063595 2400 W 7063607 Code 7063572 7063584 1400 W 7063596 2800 W 7063608 Code 7063573 7063585 2000 W 7063597 4000 W 7063609 Code 7063574 7063586 2000 W 7063598 4000 W 7063610 Code 7063575 7063587 600 W 7063599 1200 W 7063611 Code 7063576 7063588 800 W 7063600 1600 W 7063612 Code 7063577 7063589 1200 W 7063601 2400 W 7063613 Code 7063578 7063590 1400 W 7063602 2800 W 7063614 Code 7063579 7063591 2000 W 7063603 4000 W 7063615 Code 7063580 7063592 2000 W 7063604 4000 W 7063616 (1) For the operation of the MAJOR 2 CV 1D or CH 41D with 2 electric heaters, CIAT recommends to use a PI control device, with time-proportional management of the electric heater and post-ventilation required when the unit is switched off. Units are in stock to meet your requirements at short notice. CIAT declines any responsibility in the event of non-use of a V30, V200, V2000 and V3000 control unit with MAJOR 2 CV 1D or CH 41D units equipped with two electric heaters. See control pages for a complete offer: Comfort unit + control 9

ACCESSORIES FOR CASED MAJOR 2 (SUPPLIED SEPARATELY) Model Description 426 N 428 N 430 N 432 N 434 N 435 N CV1D CO1 90 rubber elbow Code 7023445 CV1D CH41D * PO2 Support feet and pipe cover *used to hide piping Code 5854900 5854901 5854902 5854903 5854904 CV1D SO3 Rear support for plinth Thickness 55 mm (for plinth thickness: 70 mm) Code 5854910 5854911 5854912 5854913 5854914 Code 5201727 CV1D CH41D X1 Paint corrector touching-up pen RAL 9010 (12 ml content) CV1D CH41D RA1 RA2 2 piece male / female connector 3/8" < 1/2" seals included 2 piece male / female connector 1/2" < 3/4" seals included Kit condensate drain pump for CH41D model to mount on the unit with overflow safety device. 7l/h maximum flow for 1m draining height and 5m maximal length of piping. 6l/h maximum flow for 1m draining height and 10m maximal length of piping. Draining : 6mm internal diameter flexible tube, 8mm diameter nozzle. For higher drain heights, consult us. One regulation for each valve must be added to allow slaving the overflow safety device to the valve closing (condensates stopped). Fixation assembly supplied with the diagram. Approximate calculation of the condensed water flow: Qv (l/h) = P total - P sensible (W) 680 Code 5202314 + 5200708 Code 5202313 5202313 + 5202079 Accessories are on stock to meet your requirements in the shortest time limits. ACCESSORY FOR CASED MAJOR 2 (MOUNTED ON THE UNIT) 7015200 Model Description 426 N 428 N 430 N 432 N 434 N 435 N CH41D PR1 Condensates drain pumpmounted on the Comfort unit with anti-overflow security. 7l/h air flow for a drain height of 1m and 5 m maximum pipe length 6l/h air flow for a drain height of 1m and 6 m maximum pipe length For higher drain heights consult us; Evacuation: flexible tube of interior diameter 6mm, end-piece diameter 8mm. This accessory must be completed with a valve control to enslave the security to the valve closing (condensates stopping). P total - P sensible (W) Condensates flow approximate calculation: Qv (l/h) = 680 Code E038415 10

TARIF HT Fan coil units UNITS WITH AIR CONTROL IN STOCK MAJOR 2 CH41D - 2 Pipes MAJOR 2 CV 1D - 2 Pipes WALL THERMOSTAT FLUSH-MOUNTED THERMOSTAT AIR CONTROL Application Diagram 426 N 428 N 430 N 432 N 434 N 435 N Major 2 CH41D, 2 tubes on left Unit code (a) 7063575 7063576 7063577 7063578 7063579 7063580 heating/cooling with manual toggle switch heating or cooling only 3 speeds - Heating/cooling with automatic changeover supplied as a kit 3 speeds - Heating or cooling only RTR-E 7015 5950338 RTR-E 7009 RTR-E 7009 7191518 A34H 7175611 A32H A30H RTR-E code (1) 5201023 Total price (a+1) RTR-E code (2) 7124612 Total price (a+2) V30 code (3) + CO2 sensor (4) Total price (a+3+4) 7166781 + 7209243 7175609 V30(3) code 7166781 7175607 Total price (a+3) Major 2 CV1D, 2 pipes on left Unit code (b) 7063569 7063570 7063571 7063572 7063573 7063574 heating/cooling with manual toggle switch heating or cooling only 3 speeds - Heating/cooling with automatic changeover supplied as a kit 3 speeds - Heating or cooling only Major 2 CV1D, 2 pipes on left equipped with V30 (fitted) Flush-mounted V30 with +/ - dial, 3 speeds - Return air sensor- Heating/cooling with automatic changeover Flush-mounted V30 with +/ - dial, 3 speeds - Return air sensor - Heating Flush-mounted V30 with +/ - dial, 3 speeds - Return air sensor - Cooling RTR-E 7015 5950338 RTR-E 7009 RTR-E 7009 7191518 A34H 7175611 A32H A30H RTR-E code (1) 5201023 Total price (b+1) RTR-E code (2) 7124612 Total price (b+2) V30 (3) + CO sensor (4) Total price (b+3+4) 7166781 + 7209243 7175609 V30(3) code 7166781 7175607 A34V 7175610 A30V 7175606 A32V 7175608 Total price (b+3) V30 equipped unit code (c) Total price (c) 7192018 7192019 7192020 7192021 7192022 7192023 Accessories are on stock to meet your requirements in the shortest time limits. 11

TARIF HT Fan coil units 2-PIPE WATER CONTROL UNITS IN STOCK MAJOR 2 CH41D - 2 Pipes MAJOR 2 CV 1D - 2 Pipes WALL THERMOSTAT WATER CONTROL Application Diagram 426 N 428 N 430 N 432 N 434 N 435 N MAJOR 2 CH41D, 2 pipes on left + 230 V four-way valve fitted 5954220 Unit code (d) 7070677 7070678 7070679 7070680 7070681 7070682 RTR-E code (5) 5201024 heating/cooling with manual toggle RTR-E 7012 5950384 Total price (d+5) switch heating or cooling only 3 speeds - Heating/cooling with automatic changeover supplied as a kit 3 speeds - Heating or cooling only Major 2 CH41D, 2 tubes on left + 230 V two-way valve supplied as a kit heating/cooling with manual toggle switch Marche/arrêt + 3 vitesses + potentiomètre manuel - chaud ou froid uniquement heating or cooling only Major 2 CH41D, 2 tubes on left + 230 V two-way valve supplied as a kit heating/cooling with manual toggle switch heating or cooling only 3 speeds - Heating or cooling only Major 2 CV1D, 2 pipes on left + 230 V two-way valve supplied as a kit heating/cooling with manual toggle switch heating or cooling only 3 speeds - Heating/cooling with automatic changeover supplied as a kit 3 speeds - Heating or cooling only 5950268 RTR-E code (6) 5201018 5950459 Total price (d+6) E35H 7175618 V30 code (3) + 7166781 + 7209243 CO2 sensor (4) Prix tarif global (d+3+4) E33H 7175615 V30(3) code 7166781 E31H 7175613 Total price (d+3) Unit code (a) + 7063575 7063576 7063577 7063578 7063579 7063580 kit code (7) 7185602 7185602 RTR-E code (5) 5201024 RTR-E 7012 5950384 Total price (a+7+5) 5950268 RTR-E code (6) 5201018 Total price (a+7+6) 5950459 E32H 7175615 V30(3) code 7166781 Total price (a+7+3) E30H 7175613 Unit code (b) + kit code (7) 7063569 7063570 7063571 7063572 7063573 7063574 7185602 7185602 RTR-E code (5) 5201024 RTR-E 7012 5950384 Total price (b+7+5) 5950268 RTR-E code (6) 5201018 Total price (b+7+6) 5950459 E32H 7175615 V30(3) Code 7166781 E30H 7175613 Total price (b+7+3) Unit code (b) + 7063569 7063570 7063571 7063572 7063573 7063574 kit code (8) 7185603 7185603 RTR-E code (5) 5201024 RTR-E 7012 5950384 Total price (b+8+5) 5950268 RTR-E code (6) 5201018 Total price (b+8+6) 5950459 V30 (3) + CO2 (4) code 7166781 + 7209243 E35H 7175618 Total price (b+8+3+4) E33H 7175615 V30(3) Code 7166781 Total price (b+8+3) E31H 7175613 12

TARIF HT Fan coil units 2-PIPE WATER CONTROL UNITS IN STOCK (continued) MAJOR 2 CV 1D - 2 Pipes FLUSH-MOUNTED THERMOSTAT WATER CONTROL Application Diagram 426 N 428 N 430 N 432 N 434 N 435 N MAJOR 2 CV1D, 2 pipes on left equipped with V30 (fitted) - Two-way valve kit Flush-mounted V30 with +/ - dial, 3 speeds - Return air sensor- Heating/cooling with automatic changeover MAJOR 2 CV1D, 2 pipes on left equipped with V30 (fitted) - Four-way valve kit Flush-mounted V30 with +/ - dial, 3 speeds - Return air sensor- Heating/cooling with automatic changeover E34V 7175617 E35V 7175617 V30 equipped unit code (c) + kit code (7) Total price (c+7) - V30 equipped unit code (c) + kit code (8) Total price (c+8) - 7192018 7192019 7192020 7192021 7192022 7192023 7185602 7185602 7192018 7192019 7192020 7192021 7192022 7192023 7185603 7185603 TARIF HT 4-PIPE WATER CONTROL UNITS IN STOCK WATER CONTROL Application Diagram 426 N 428 N 430 N 432 N 434 N 435 N Major 2 CV1D, 4 pipes on left + 2 x 230 V two-way valves supplied as a kit Unit code (e) + kit code (7) 7063581 7063582 7063583 7063584 7063585 7185602 7063586 7185602 deadband RTR-E 7203 5950323 RTR-E code (9) 5201021 Total price (e+7+9) - MAJOR 2 CV 1D - 4 Pipes WALL THERMOSTAT 3 speeds - Heating/cooling with deadband Major 2 CV1D, 4 pipes on left + 2 x 230 V four-way valves supplied as a kit deadband E40H 7175641 RTR-E 7203 5950323 V30(3) Code 7166781 Total price (e+7+3) Unit code (e) + kit code (8) 7063581 7063582 7063583 RTR-E code (9) 5201021 7063584 7063585 7185603 7063586 7185603 Total price (e+8+9) 3 speeds - Heating/cooling with deadband E41H 7175641 V30(3) Code 7166781 Total price (e+8+3) 13

EUROVENT PERFORMANCES - 2-PIPE SYSTEM CIAT takes part in the EUROVENT fan coil unit certification programme. In order to benefit from the latest updates, we advise you to consult the EUROVENT Internet site www.eurovent-certification.com. EUROVENT mode, 2-pipe system : - Summer: cold water 7/12 C, air 27 C WB 19 C - Winter: hot water inlet 50 C for determined water flow in summer mode, air 20 C Major 2 Motor code Air flow rate Sensible cooling capacity Total cooling capacity Heating capacity Dp (cooling) Dp (heating) Lw m 3 /h kw kw kw kpa kpa db A 426 N 428 N 430 N 432 N 434 N 435 N R3 365 1.720 2.070 2.380 20.4 17.4 55 R5 235 1.160 1.440 1.620 10.4 9.1 45 R7 105 0.532 0.681 0.747 2.60 2.45 29 R2 620 2.690 3.110 3.850 24.2 20.5 58 R4 420 2 2.420 2.760 15.2 13.1 50 R6 265 1.320 1.660 1.830 7.64 6.72 39 R2 730 3.200 3.830 5.030 17.1 14.8 57 R4 495 2.300 2.810 3.590 9.60 8.48 48 R6 310 1.430 1.750 2.300 4.00 3.67 37 R1 940 3.970 4.770 6.210 31.1 26.3 59 R3 660 3.040 3.810 4.710 20.6 17.6 51 R6 325 1.420 1.740 2.120 4.99 4.45 36 R2 1180 4.950 5.840 7.660 21.7 19 61 R4 905 3.950 4.810 6.120 15.0 13.3 55 R7 475 2.170 2.620 3.400 4.83 4.43 42 R1 1370 5.690 6.580 8.700 27.0 23.6 64 R4 1020 4.300 5 240 6.790 17.7 15.6 56 R6 730 3.320 4.100 5.070 11.1 9.94 48 EUROVENT PERFORMANCES - 4-PIPE SYSTEM CIAT takes part in the EUROVENT fan coil unit certification program. In order to benefit from the latest updates, we advise you to consult the EUROVENT Internet site www.eurovent-certification.com. EUROVENT mode, 4-pipe system: - Summer: cold water 7/12 C, air 27 C WB 19 C - Winter: hot water 70/60 C, air 20 C Major 2 NCH Motor ref Air flow rate Sensible cooling capacity Total cooling capacity Heating capacity Dp (cooling) Dp (heating) Lw 426 N 428 N 430 N 432 N 434 N m 3 /h kw kw kw kpa kpa db A R3 365 1.730 2.070 2.520 20.4 13.0 55 R5 235 1.160 1.440 1.910 10.4 7.98 45 R7 105 0.534 0.681 1.040 2.60 2.74 29 R2 620 2.690 3.110 3.810 24.2 40.0 58 R4 420 2.000 2.420 3.010 15.2 26.4 50 R6 265 1.320 1.660 2.220 7.64 15.4 39 R2 730 3.200 3.830 5.080 17.1 71.4 57 R4 495 2.300 2.810 4.010 9.60 47.0 48 R6 310 1.430 1.750 2.890 4.00 26.6 37 R1 940 3.980 4.770 4.340 31.1 16.0 59 R3 660 3.050 3.810 3.500 20.6 10.9 51 R6 325 1.420 1.740 2.150 4.99 4.57 36 R2 1180 4.960 5.840 5.290 21.7 19.1 61 R4 905 3.960 4.810 4.510 15.0 14.4 55 R7 475 2.170 2.620 2.940 4.83 6.69 42 R1 1370 5.700 6.580 5.750 27.0 22.3 64 435 N R4 1020 4.310 5.240 4.860 17.7 16.4 56 R6 730 3.330 4.100 3.930 11.1 11.2 48 Dp: Water pressure drop in kpa Lw: Overall acoustic power in dba 14