Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

Similar documents
Battery Electrical And Starting Tester

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

ATD Amp Carbon Pile Battery Tester User s Manual WARNING

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS Ext. 322

BATTERY & STARTER ANALYSER (BSA-12) User Manual

Advanced Test Equipment Rentals ATEC (2832) 5-Gas Analyzer. 16 & 16P Operator s Manual

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

Model: SE-4020-CA Automatic Battery Charger

Owner s Manual & Safety Instructions

PSJ-2212, PSJ-3612, PSJ-4424

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

Simplified Check Program for Charging Systems

Digital Auto Multi-Tester

SP6. Automatic Battery Charger. Model

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

User Guide IGD Series

777P-PT Battery Charging/Starting System Analyzer with Printer

Matson Jump Starter Operator s Manual

# Traction Control Window Switch

BATTERY 8A - 1 BATTERY CONTENTS

BEST 6042 BATTERY TESTER

Models: SP3, SPSS3 Automatic Battery Charger

Installation and Operating Instructions (for chargers shown below)

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

SB-300 Operator s Manual

OWNER S MANUAL PORTABLE POWER COMPACT & ROBUST

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

Safety, Installation And Operating Instructions For The Following Battery Charger Models: i2412, i3612, i4809, i2425, i3625, and i4818

OPERATOR S MANUAL JUMP STARTER. and DC Power Source. Model No CAUTION: Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

10AMP FULLY AUTOMATIC 6V & 12V BATTERY CHARGER OWNER'S MANUAL

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Go Power! Manual. GP-Smart Charger

JUMP STARTER OPERATOR S MANUAL RA1900

LESTRONIC II BATTERY CHARGER MODEL 19740

CLEAN POWER TM CPS Series Operator s Manual

Model: OBD-L On-Board-Diagnostics II Memory Saver Detector

BATTERY 8A - 1 BATTERY CONTENTS

BAT 135 Battery Tester Operating Instructions

Pump Installation and Service Manual HRS Hydromatic Retractable System

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

Cruising Charger Series OWNER S MANUAL

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

User s Manual. Model 1855 Variable Load Battery and Systems Tester WARNING

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

10 AMP ON BOARD BATTERY CHARGER

Wiring Installation Instructions for : Pressure. Wiring Installation Instructions for : Temperature. 2 1/16 Spek Pro Professional Racing Gauge

STARTING SYSTEM TEST STARTING SYSTEM

12V Manual Battery Charger

WJS-3500 User Guide MIGHTY JUMP STARTER. Portable Jump Start & Power Supply

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

SAVE THESE INSTRUCTIONS

SPC-PANEL Simplex, Single Phase Pump Control Panel

IMPORTANT SAFETY INSTRUCTIONS

installation and operating instructions for the following xtreme Battery chargers:

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

FEATURES. Power Status and Charge Indicator: A red LED indicates the battery is charging and a green LED indicates the battery is fully charged.

Digital Mobile Charge Advanced Electronic In-Transit 4-Stage Battery to Battery Charger

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Power Beam 20MCP Searchlight with 12 LED Area Light and Vehicle Jump Starter. Instruction Manual

OBAE, OBAEXU, ON BOARD Battery Chargers

OBE, OBEXU, ON BOARD Battery Chargers

600 Amp Battery Jumper with Air Compressor

RoaDCharger 20 Amp 7 Way Installation Manual

20A Solar Charge Controller

ELECTRICAL BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. KEEP IT WITH OR NEAR CHARGER AT ALL TIMES.

CRS1, CRS2 and CRS3. For additional information please call our. PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard, LaVergne, TN

QuickBoost Instruction Manual

WJS-1800 User Guide MINI JUMP STARTER. Portable Jump Start & Power Supply

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

BusPro Series Instruction Manual

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

S150,S300 Series Pure Sine Wave Inverter User s Manual

OPERATOR S MANUAL. Portable Power 950. Model No

ELECTRICAL. CDTA Technical Training Center

OWNERS MANUAL Models: XP400, XP500, XP750C INSTANT POWER Jump Starter and DC Power Source

Battery Charger XT EXTENDED. For lead-acid batteries. User Manual and Guide to professional charging of starter and deep cycle batteries.

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

- Optional Audio warning when discharge test is complete or tester malfunction.

ADJUSTABLE COMFORT ASSEMBLY INSTRUCTIONS

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

A48 / A48B (base plate) BATTERY CHARGER

SAFETY PRECAUTIONS SAFETY FIRST!... 1 ABOUT THE CODE READER CONTROLS AND INDICATORS... 3 DISPLAY FUNCTIONS... 4

DieHard. BATTERY CHARGER/MAINTAINER 1.5 Amp Fully Automatic Float-Mode Monitoring. Model No

A2P Single Phase Automatic Industrial Battery Charger

Owner s Manual Model Nos. 2001/3001

A39 UNIVERSAL SCR CHARGER

Deep Cycle Battery Safety. First. Battery Handling, Maintenance & Test Procedures

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

QPET, QPETXU Battery Chargers

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

SAFETY PRECAUTIONS AND WARNINGS...

PTI900X PST-900X. Battery Tester with Printer. For 6 and 12 Volt batteries and 24 Volt charging systems OWNERS MANUAL

SB SWITCH CONTROL BOX

Battery Back-up Model: BBM-1225

Installation and Operating Instructions (for chargers shown below)

Transcription:

Battery Tester GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G 40 & 42HD Operator s Manual

SPECIFICATIONS Measurement Range...Ferret 40... Ferret 42HD Battery Volts... 4.0 to 19.99... 4.0 to 40.0 External (10 Meg)... 0 to +/- 19.99... 0 to +/- 19.99... 0 to +/- 50.0... 0 to +/- 50.0 Amps (Inductive)... 0 to +/- 199.9... to +/- 199.9... 0 to +/- 600... 0 to +/- 1200 Load (15 Seconds On, 60 Off)... 500 Amps... 600 Amps 24 Volt Charging Load...N/A... 150 Amps Amps Ripple Indicator...Yes... Yes Load On Timer...Yes... Yes Load Limit Indicator...No... Yes Hot Load Indicator...No... Yes 24 VOLT SYSTEM TESTING The 42HD was designed for testing 24 volt systems. The load leads can be connected directly to 24 volts to power the tester. Additionally a load of up to 150 amps can be applied to verify the operation of the charging system. Since most 24 volt systems are made up of two 12 volt batteries, be sure to test each battery separately for an accurate test. INDICATOR LIGHTS Amps Ripple The Amps Ripple indicator will illuminate when AC ripple is detected from the alternator. Load On The Load on Indicator will flash and the beeper will sound one time a second to help time the load test. After 16 seconds, the beeper will sound continuously indicating the end of the load test. Load Limit The Load Limit Indicator will turn on when you are approaching the load capacity of the carbon pile. Hot (Do Not Load) When this light turns on, do not apply a load. Let the Fan run to cool down the carbon pile. SAFETY PRECAUTIONS Read All Instructions Before Using The Meter Always wear eye protection when testing vehicles. Be extra careful near batteries and moving parts. Do not lay tools on a battery. Battery gas is highly explosive. a. If a battery explodes flush the acid away from persons skin with generous amounts of water. Follow up with a neutralizing solution of baking soda and then more water.treat clothing, vehicle parts, and equipment similarly. Any acid traces inside equipment must be removed by generous rinsing. Dry equipment and place in a warm 50 C (120 F) oven until thoroughly dry. b. Never use a wrench on the ungrounded battery terminal until the grounded one has been disconnected. Contact between the vehicle body metal and the hot terminal can cause sparks to ignite gas or even weld tools into a battery short circuit. c. Keep the space around a battery well ventilated. d. Do not make sparks or allow flames near batteries. Before working on a vehicle set the brakes and block the wheels. Beware of automatic parking brake releases. Keep your work area well ventilated and free of exhaust. Engine exhaust contains deadly poisons. Treat Gas Detector exhaust and drain hoses the same as the vehicle tailpipe. Both give off deadly exhaust fumes. Avoid electrical shocks caused by getting close to live ignition wires or touching the coil TACH terminal. A person s reaction near a live engine can be more damaging than the shock. Keep spark producing devices at least 0.5m (18 ) above the floor to reduce the hazard of igniting gasoline vapor. Do not let test leads wind up in a moving fan or pulley. Route leads away. Remove finger rings and metal wrist bands. They can short terminals and become very hot from electric current. E040-01G

WARRANTY FERRET BRAND LIMITED PRODUCT WARRANTY GxT, Inc. of Cheboygan Michigan, warrants to the original purchaser that FERRET brand products are free from defects in materials and workmanship for a period of two years from date of purchase. Our sole obligation for a product within the above warranties will be to repair or replace, at our option, any defective parts and return the product to the sender within the U.S.A., shipping prepaid, if it is sent to our Repair Department shipping prepaid and accompanied by proof of purchase. This Warranty does not apply to products which have been altered outside the factory; or repaired by anyone other than the factory or its authorized service centers; or which have been damaged from accidents, negligence, or abuse; or have been used differently than described in the printed instructions. Please note that wear and tear on leads and replacement of consumable items such as: NOx Sensors, Oxygen Sensors, and paper, is not covered by warranty. GxT Inc. s sole liability and buyer s exclusive remedy is limited to repair or replacement of the product as stated in the Limited Product Warranty. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THOSE OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND GxT, INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUEN- TIAL DAMAGES ARISING FROM THE SALE OR USE OF THE PRODUCT. Some states do not allow limitations on the length of implied warranties nor exclusion or limitations of incidental or consequential damages, so that the above limitations and/or exclusion may not apply to you. Load On Timer Volts Display Amps Zero Buttons Amp Probe Auxiliary Volts Leads Amps Ripple Indicator Load Limit Indicator (42HD Only) Hot Load Indicator (42HD) Load Knob Voltage Selector Load & Power Leads This warranty gives you specific legal rights and you may also have other rights which may vary from state to state. General specifi cations given in this manual are for 12 volt systems. There are some vehicles which will require the actual service specifi cation values for correct test con clu sions. This manual assumes that Negative Ground battery systems are being tested.

LOAD TEST CAUTION Wear Safety Glasses, Do not break live circuits at the battery t e r m i n a l s, A v o i d accidentally shorting the insulated battery terminal to any ground metal. Never put a wrench on a live battery wire terminal. Zero Amp Meter. Then Place AMP PROBE around either analyzer cable. CHASSIS BLACK Burns may be the result. Disconnect the battery chassis cable first 1. Be sure the Load Knob is turned to OFF before connecting the analyzer cables to the battery. Take note of the safety precautions on the back cover of this manual. 2. Connect the analyzer Battery Clamps to the battery terminals; Red to positive, Black to negative. The cable jaw contact from each clamp must make a solid connection to the battery terminal to assure good voltage measurements and avoid sparks during load tests. Side terminal batteries may need special adapters attached to make solid connections for high current load tests. 4. With the Amp Probe jaws closed and not around any wires, press the Zero Amps buttons until the Amps Display shows 000 5. Connect the Amp Probe around either analyzer load lead. Open Circuit Voltage Test Measure the open circuit (no load) stabilized voltage. A stabilized battery has no surface charge, which means that the electrolyte has had a chance to remix and shed gas bubbles after current flow has stopped. With less than 12.4 volts, first recharge the battery. Open Ckt. Volts 12.6 12.4 12.2 12.0 % of Charge 100 75 50 25 RED TYPICAL STARTER CRANKING DRAW Engine Size Cubic Inches Liters Amperes 100 to 200 1.6 to 3.2 100 to 200 200 to 350 3.2 to 5.6 125 to 250 350 to 500 5.6 to 8.0 150 to 300 NOTE: Higher starter amps may be encountered if engine temperatures are extremely hot or cold. 9. Test Conclusions. The system is good if the cranking speed is satisfactory and the battery voltage stayed above 9.6 volts. If Crank Speed was slow use the following chart. VOLTAGE AMPS LIKELY CAUSE Below 9.6 High Bad Starter or a very hot or cold engine. Below 9.6 Low Bad Battery or Loose Battery Terminals. Above 9.6 Low Connections at Starter or Solenoid. TECHNICAL SUPPORT & SERVICE Questions or inquiries about service can be answered by contacting GxT, Inc., at: Toll Free (800) 627-5655. Fax: (231) 627-2727, Toll Free (231) 782-0616 When sending an item to the factory address it to: GxT, Inc., 520 MM Riggs Drive., Cheboygan, MI 49721-1061 Include a note describing the problem.

CHASSIS STARTER TEST When testing the starting system, first test for battery performance. With a known good battery, the starter motor, cables and starter solenoid can be checked. Starter amps should not exceed the maximum specified for the vehicle being tested, and the cranking RPM should be satisfactory. 1. Engine should be at normal operating temperature. Make sure all lights and accessories are off and vehicle doors are closed. 2. Be sure the Load Knob is turned to OFF before connecting the analyzer cables BLACK RED Connections For STARTER TEST KEY SWITCH TRANSMISSION SAFETY SWITCH STARTER SOLENOID RELAY to the battery. Take note of the safety precautions on the back cover of this manual. 3. Connect the analyzer Battery Clamps to the battery terminals; Red to positive, Black to negative. 4. With the Amp Probe jaws closed and not around any wires, press the Zero Amps buttons until the Amps Display shows 000 5. Place the Amp Probe around either of the engines battery cables. 6. Set the Volts Selector to Battery Volts. 7. Disable the ignition by either disconnecting its power, unplugging the coil primary, or grounding the coil secondary wire. 8. Crank engine for 15 seconds with ignition key and note the cranking amperage reading. Also, watch to see that the battery voltage stays above 9.6.V. Wait a few minutes for the starter to cool if the cranking test is repeated. 1. Determine the battery load test amperes from the battery test specification, CCA, or Ah ratings. To give consistent results a load test requires that a battery be at least 75% charged and not have been heavily used within the last 10 minutes. Cold Cranking Amperes at 0 F. (CCA) Use 1/2 the CCA for a load test. For example, 360 CCA divided by 2 equals a 180 ampere test load. Ampere Hour Rating (Ah) Multiply the Amp Hour Rating by 3 to obtain the load. For example, a 60 Ah battery times 3 equals a 180 ampere load. 2. Turn the Load Control Knob clockwise until the amps reading gradually reaches the required load. While the load is being applied, watch the battery voltage. After 15 seconds at the test amperage, or if the voltage goes below the minimum value, turn the load off. NOTE: The Load-on Lamp flashes and beeps once per second. After 16 seconds of load current, the beeper will sound continuously. LOAD TEST CAUTION If a battery smokes while being loaded, stop testing immediately. It is not safe. 3. Test Conclusions. If the battery voltage went below the minimum voltage from the table during the test the battery is either discharged or defective. Recharge and test again if necessary. At 70 F and higher a good battery will maintain an output of 9.6 volts or more during the loading period (4.8 volts for 6 volt batteries). When a battery is cooler than 70 F, the output voltage requirement is reduced to give equivalent test conclusions per the following table: ELECTROLYTE TEMP. MINIMUM F C LOADED VOLTS 70 21 9.6 60 16 9.5 50 10 9.4 40 4 9.3 30 1 9.1 20 7 8.9 10 12 8.7 0 18 8.5 USE HALF VOLTAGE FOR 6 VOLT BATTERIES.

VOLTAGE DROP TEST The voltage drop test is a very helpful diagnostic test for determining the condition of cables and connections for the starting charging circuit. The voltage drop test can be used on any part of the circuit. In the example below, RED we are checking the entire circuit CHASSIS POS from the positive side of the battery to the SOLENOID starter. 1. Be sure the Load Knob is turned to OFF before connecting the analyzer cables to the battery. Take note of the safety precautions on the back cover of this manual. 2. Connect the analyzer Battery Clamps to the battery terminals; Red to positive, Black to negative. 3. Select external volts. 4. Connect the external volts leads as shown in the illustration. Connect the Red auxiliary lead to the positive side of the battery. Connect the Black lead to the input terminal of the starter. 5. Disable ignition to prevent the engine from starting during the test. 4. Operate the Starter and read the voltmeter while cranking. 5. Test Conclusions. Good circuits drop less than 0.50 volts on a 12 volt system. Typically you should not have more than 0.10 volts drop per connection. REGULATOR CHARGING VOLTAGE BLACK STARTER RELAY Connections For INSULATED - POS CURCUIT TEST Follow the same setup and test procedure used for the alternator test, except put the Amp Probe around either battery cable. Once the charging amperage drops below 20 amps, the voltage displayed will be the regulator setting. This should be between 13.5 and 15.5 volts on a 12 volt system. ALTERNATOR OUTPUT TEST Always compare test results with manufacturer s specifications before coming to conclusions regarding the performance or efficiency of charging systems and their components 1. Be sure the Load Knob is turned to OFF before connecting the analyzer cables to the battery. Take note of the safety precautions on the back cover of this manual. 2. Connect the analyzer Battery Clamps to the battery CHASSIS ALTERNATOR Connections For AMPERAGE OUTPUT TEST OUT FIELD REGULATOR KEY SWITCH terminals; Red to positive, Black to negative. 3. With the Amp Probe jaws closed and not around any wires, press the Zero Amps buttons until the Amps Display shows 000 4. Place the Amp Probe around the alternator output wire. Try to position the probe away from strong magnetism near the back shaft end of the alternator to avoid measurement error. 5. Display Battery Volts. 6. Start and run the engine at about 2000 RPM. 7. Turn the Load ON and increase until the battery voltage decreases to be between 12 and 13 volts while reading the output amperage. 8. Turn Load OFF and reduce RPM. 9. Test Conclusions a. If the Amps Ripple lamp stayed on during the output test replace the alternator. b. If the amperage abruptly decreased during the test check for a loose belt. c. If output was less than 90% of rating use the voltage drop test to check output resistance. d. If output did not change, full field the alternator. If the alternator output increases, replace the regulator.