EPM72 Engine Protection Module

Similar documents
PSM72H Push-Button Start Module

REVISED ATM72 Auto Transfer Module

SDM72 Start on Demand Modules

BVF300 'Special' Battery Voltage Monitor

SUM340 SUMMATION BOARD

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

GENSET CONTROL MODULE A121A / A241A

DEEP SEA ELECTRONICS PLC

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.

AUTOSTART 705S V1.00 AUTOSTART 710S / 720S / 730S V1.04 Programming Reference and Check Sheets

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

DEEP SEA ELECTRONICS PLC

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.

DEEP SEA ELECTRONICS PLC

Flight Systems. Replacement for KASSEC DESCRIPTION

GCU-10. Automatic Engine Control Unit Operators Manual

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

DEEP SEA ELECTRONICS PLC

DKG-114 MANUAL AND REMOTE START UNIT

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

DEEP SEA ELECTRONICS PLC

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

ANALOG CONTROL PANEL

Crompton Controls. This is. Installation and Maintenance Instructions. S10 & Smooth-BRAKE DC Injection Brake Modules. Tel: +44 (0)

ES52 Auto Start Engine Controller Installation and User Manual for the ES52 Auto Start Engine Controller.

Application Engineering

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

ECU. Speed Switch Manual. Contents. ECU is a registered trademark of Engineering Concepts Unlimited Inc.

Deep Sea Electronics Plc

R & D SPECIALTIES ROTROL I USER'S MANUAL

ESC2301. Universal Electronic Governor Controller Operation Manual

N1387 Series Troubleshooting Guide for N Alternators

ES52. Auto Start Engine Controller. Full Version. Installation and User Manual for the ES52 Auto Start Engine Controller.

ICON 2 1. FEATURES AND CHARACTEIRICS

DEEP SEA ELECTRONICS PLC

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

EG3000. Generator Electronic Governor Controller Operation Manual

Energy Division

Designed for ease of integration with automation systems

James Hamilton Electrical Pty Ltd (Inc in Qld) A.C.N trading as. Power Drive Systems. Generator Control Specialists

Application Engineering

DKG-215 MANUAL AND REMOTE START UNIT

60 Series Engine Controls

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

ADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

EG1069X. Generator Electronic Governor Controller Operation Manual

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

AA4006 Speed Sensitive Trip Unit. User Manual

DEEP SEA ELECTRONICS PLC

EA07. Generator Automatic Voltage Regulator Operation Manual

Controls and Instruments

EG1065X. Compatible with Barber Colman* Dyn1-1065X series * Use for reference purpose only and not a genuine Barber Colman product.

Deep Sea Electronics Plc

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

GSC300 Auto Start Engine Controller

Generator Sets Controller 210. Operation Manual. Ver1.0

WARRANTY WILL BE VOID If These Steps are Not Performed Before Installing The Control STEPS TO PERFORM BEFORE CONTROL INSTALLATION

R-200A R-200C Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Troubleshooting Guide

R-200A Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

Electric Gage Shutdown Panels for DEUTZ 1011/2011, 912/913 and 914

STANDARD OWNER S MANUAL

MX431 Generator Automatic Voltage Regulator Operation Manual

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

Open Chassis Star-Delta Starter User Guide

HSC940 Genset Controller CONTENTS 1 OVERVIEW PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION KEY FUNCTIONS...

SDS Enclosed Star-Delta Starter User Guide

CONTROLLER DIAGNOSTIC GUIDE

DKG-317 MANUAL AND REMOTE START UNIT

HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

AUTOMATIC STAND-BY AND PEAK-LOAD CONTROL

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

WARRANTY INFORMATION...

GSC300 Auto Start Engine Controller

User Guide 4Q kW D.C.Motor Regenerative Speed Controller. Part Number: Issue Number: 3

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

HGM6000K Series Automatic Generator Module OPERATING MANUAL Smartgen Electronic

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

P445 Series Electronic Lube Oil Control

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

R-200A R-200B Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

Generator Controller Manual

Transcription:

Capricorn Controls DA01EPM1-1 Data & Application Note Page 1 of 8 EPM2 Engine Protection Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom Products All facilities as KSM2... plus much more! (optional) Pin for Pin compatibility with RSM2 (optional) Crank-Cut & Over-crank lockout (optional) Integral Hours Counter Combining the convenience of manual operation with engine protection against Low Oil Pressure (LOP), Coolant Fault (HET) and EPM2D (optionally) Overspeed & / or an Auxillary Input, these Keystart Modules are easily mounted into almost any control panel or switchbox. Set in a compact 2mmsq DIN sized module they can be used with a wide range of engine driven equipment. The front panel has five High Intensity LED s indicating system status. The key switch provides PREHEAT OFF / RESET RUN START (EPM2_J option Only) Select Pre-Heat if required, just prior to starting the engine. Use it for the shortest possible time to preserve charge in the battery (typically 10sec but dependant on the ambient temperature). Do not leave the switch in this position. (See page-3 for Timed Pre-Heat options). Use to stop the engine and resets all Shutdowns. Always ensure that the engine is stationary before restarting. Powers the unit, energises the fuel solenoid and starts the Hold-Off timer (T0). If the key remains in this position for 25sec s or more, the Hold-Off timer will elapse and the module will latch out on Low Oil Pressure. To start the engine from an alarm condition, the key must first be turned to the OFF position for at least 1 second (see above). Hold in this position to crank the engine, releasing it to the Run position as soon as the engine fires. If the engine fails to start after approx. 10 sec s return the key to the OFF position, wait approx. 10 sec s and try again. If the engine fails to start after three attempts, turn the key to the Off position and consult the manufactures Handbook. Assuming that the engine fires, the keyswitch is released to disengage the starter motor; the set runs up to normal speed and the Hold-Off timer (T0) is running. The tachometer circuitry (EPM2B or D) continually monitors for Overspeed. When the hold-off timer has elapsed, the LOP and HET fault circuits are enabled. In the event of a shutdown, the appropriate fault Led is lit, the Alarm output (if applicable) is activated, the Fuel & Starter relays are locked out and the LOP & HET channels disabled (first-up interlock). The 'close to Ve on fault', Auxiliary input is always active as it is not inhibited by T0 or any other shutdown. If T0 is required then select an EPM2 with the T option (see page 5). Designed & manufactured in England by Capricorn Controls Telephone: +44 (0) 1295 22360 Fax: +44 (0) 1295 26466 E-mail: sales@ capricorn-controls.com

Page 2 of 8 ORDERING INFORMATION Channel 5 Pin Compatible Model No. Connectors Overspeed Charge Fail Lamp Only With EPM2A One --- --- Yes KSM2A EPM2B One Yes --- Yes KSM2B EPM2C One --- Yes --- KSM2C EPM2D One Yes Yes --- KSM2D EPM2CV Two EPM2C + Aux input + outputs for: Swt +ve & Alarm EPM2CZ Two EPM2CV + Timed Pre-Heat output EPM2DV Two EPM2D + Aux input + outputs for: Swt +ve, Alarm & Meter EPM2DZ Two EPM2DV + Timed Pre-Heat output EPM2D - / XX Dummy 2 nd Connector for wiring, allowing later upgrade to RSM2, by changing modules EPM2E As EPM2D + Crank-Cut on running + Overcrank Lock-out + Meter O/P Options Features Term. EPM2 - A Open collector 'Alarm' output on term. (single connector builds only) EPM2 - H Integral (LCD) 'Hours Counter' EPM2 - - M Magnetic Pick-Up (MPU) speed sensing in place of 'Main Alternator' frequency sensing. 9 & 10 EPM2 - - - R 'Active-Low' drivers for external lamps &/or relays via a separate 8-way (top) connector. a ---- h EPM2 - - - - S 'Symbols' on front panel in place of text. EPM2 - - - - -T 'Active-Low' driver output at the end of T0 period (& no fault shutdown) EPM2 - - - - - -V Pre-Heat terminated after T0 time (max. 25sec from crank-cut) to suit certain engines EPM2 - - - - - - X LED-1 to show 'Aux.' channel 'Status' in place of 'DC on'. Please specify 'overstick' label! EPM2 - - - - - - - Y Pulsed output for Fuel pull-in coil. Typically for.yanmar engines. Input Phasing EPM2 - - - EPM2 - - - / HR EPM2 - - - / LR EPM2 - - - / HLR Het (Cooling Fault) & Lop (Low Oil Pressure) are both 'closed to ground' (Batt -Ve) on fault 'Het Reversed' - open from ground (Batt -Ve) on fault 'Lop Reversed'- open from ground (Batt -Ve) on fault 'Het & Lop Reversed' - {both of the above} - open from ground (Batt -Ve) on fault NOTE: 1/ & These Models & Options are 'Mutually Exclusive' as they all use terminal, but for different functions! These 'Active-Low' driver output(s) are open collector transistors, each rated at 40V / 150mA 2/ The X Option is only available on EPM2 DV & DZ builds. 3/ The M option is only available on the EPM2B--, EPM2D-- & EPM2E-- builds 4/ EPM2CZ & DZ builds, inhibit the Starter until the Pre-Heat time has elapsed 5/ The Y option is only available on EPM2CZ & DZ builds SPECIAL BUILDS EPM2 - - - / - - / X0? These 'X' numbers, indicate non-standard product, which has been manufactured to suit a specific customer. They do not appear in any catalogues and may only be available to the original customer. When re-ordering, please quote the full part number together with the 'Serial Number' of the original unit(s). CUSTOMISED PRODUCTS If you require spare or replacement units with 'Model Numbers' & / or 'Build Options' not listed here --- please contact our sales desk for the latest price and delivery. Always quote the serial No. of the original unit. E. & O. E. The Proven Solution to Power Controls DA01EPM1-1

Capricorn Controls DA01EPM1-1 Data & Application Note Page 3 of 8 CONNECTIONS Always ensure that the correct wire sizes are used and that all terminals are tightened correctly. Terminal Description Input / Output Connect To ------ 1 LOP Low Oil Pressure -Ve Input Low Oil Pressure switch 2 HET High Engine Temp. -Ve Input High Engine Temp. switch 3 Starter Max. Load 16 Amps (resistive) +Ve Output Solenoid or Solenoid 4 Batt+ Supply +Ve Battery positive 5 Fuel Max. Load 16 Amps (resistive) +Ve Output Solenoid or Solenoid 6 Batt - Common DC -Ve supply Battery negative (See text) 8 C.F. Charge Failure +Ve Output Charging Alternator (WL) 9 AC or MPU - Speed sensing 115/230VAC (Main Alternator or 10 AC or MPU+ Speed sensing Magnetic Pick-Up (see Options ) 11 (Reserved for RSM2) 12 Meter + Analogue Meter Output +Ve Output RPM Meter / DC Voltmeter --- see text 13 Pre-Heat Open Collector Transistor -Ve Output Pre-Heat control relay 14 Alarm Open Collector Transistor -Ve Output Alarm control relay 15 Swt +Ve Switched +Ve Output +Ve Output To power, Alarm relay etc. 16 Aux Auxiliary Shutdown -Ve Input Expansion Module(s) or Spare I/P 1 (Reserved for RSM2) 18 (Reserved for RSM2) 19 L.T. Lamp Test +Ve Input Global Lamp Test circuits NOTE : De-rate to 14% for Inductive Loads (2.2A for or (Solenoid) see below Limit to 500mA Maximum. Limit to 300mA Maximum. Flywheel diode(s) should be connected across inductive Load(s) WARNING: Fuel & Starter Outputs Although the on board relays and are quite capable of directly switching small solenoids, we would recommend that slave relays are always used as a matter of course unless both the Fuel & Starter Solenoid currents are known, and are within the specification of the EPM2. In line with other manufacturers, we quote the Fuel and Starter outputs as 16A (resistive) which relates to the contact ratings of the internal relays. However, as both Solenoids & s are inductive loads this 16A rating must always be de-rated to 14%, that is maximum continuous current of 2.2A to allow for a 'seven times' inrush, when the inductive load is energised. WARNING: Voltages dangerous to human life Voltages dangerous to human life may be present at some of the terminal connections of this unit. Ensure that all AC and DC supplies isolated before attempting any connection / disconnection. Noise Suppression Components Both AC & DC inductive components (i.e. s, solenoids, etc) should be connected as shown -- C R Snubber AC COIL +V DC COIL Diode For further information or advice - Please contact the sales desk --V Designed & manufactured in England by Capricorn Controls Telephone: +44 (0) 1295 22360 Fax: +44 (0) 1295 26466 E-mail: sales@ capricorn-controls.com

Page 4 of 8 Basic Connections Standard Models EPM2A EPM2B EPM2C EPM2D EPM2E 1 2 3 4 5 6 See text Starter Fuel Low Oil Pressure sensor Cooling Fault sensor(s) F1 + Battery -- Charging Alternator WL 8 9 10 Main Alternator 40 280VAC --Ve 9 Toothed Flywheel EPM2_M Signal 10 Screened Cable Magnetic Pick-Up EPM2DV EPM2DZ ONLY 11 12 13 14 15 Used on RSM2 Remote Start Modules Pre-Heat Alarm Term.5 Fuel + + -- Meter 1mA / 5ohm Ammeter for RPM indicator.. or digital voltmeter for Calibration purposes. +V Output in RUN position 16 1 18 19 Used on RSM2 Remote Start Modules Close to Run Open to Stop Batt-Ve Auxiliary Shutdown Lamp Test (optional) NOTES : 1/ Items marked are generally available ex-stock from Capricorn Controls. 2/ Term.1 & 18, close for auto-start on RSM2. Pre-wire for upgrade path to Remote Start Module 3/ Low Oil Pressure & Cooling Fault sensors are shown close to ground on fault. See text 4/ Cooling Fault could be High Engine Temp & / or Low Coolant Level 5/ Fuse F1, rate at 5A A/S if Fuel & Starter slave relays used or 10A A/S if only starter slave fitted E. & O. E. The Proven Solution to Power Controls DA01EPM1-1

Capricorn Controls DA01EPM1-1 Data & Application Note Page 5 of 8 Wiring Instructions for Specific Build 'Options' 1/ EPM2--M-- Speed sensing via Magnetic Pick-Up (in place of main alternator frequency sensing). Term. 9 (-Ve) and term.10 (signal) should be connected to the Magnetic Pick-Up terminals via a screened cable. Always ensure that -- (a) The screen is ONLY connected to term.9 and if wired via a terminal block, that the integrity of the screen is maintained. (b) If one of the Magnetic Pick-Up connections is connected to it's case, that this one is connected to term.9 (c) The correct gap is set between the Magnetic Pick-Up and the Flywheel teeth. 2/ EPM2--R-- Seven, 'active-low' drivers allow external lamps &/or relays (150mA / 30VDC max each output) to be connected via an 8 way (top) connector. Typical applications include: remote indication (i.e. using an LPM2 Lamp Module) and volt-free contacts for 'Dial-Out' Alarm Systems. a Low Oil Pressure A A RL1 Bb RL2 Cooling Fault B Cc RL3 Overspeed C Dd Auxiliary D RL4 Ee Fail to Start E RL5 Ff Running F RL6 Gg Alarm G RL Hh (Lamp Test) H Do not connect term.15 (EPM2DVR or DZR) (EPM2) term.15 Batt +Ve 4/ EPM2--T-- 'Active-Low' driver output (on term.) at the end of the 'T0' hold-off timer period RSM2 - - T - Auxiliary I/P 16 Connected as shown above, the 'Aux.' channel is subject to the 'T0' timer, and provided with 'First-up Interlock'. This 'T0' output is capable of sinking 150mA / 30VDC and could be used to drive an external relay (connect to term.15 SW+ or term.5 Fuel +). Designed & manufactured in England by Capricorn Controls Telephone: +44 (0) 1295 22360 Fax: +44 (0) 1295 26466 E-mail: sales@ capricorn-controls.com

Page 6 of 8 5/ EPM2 - - A Active Low Alarm Output A Option : Alarm Output 5 6 Slave Batt +Ve 6/ EPM2 - - J Active High Manual Pre-Heat Output J Option : Manual Pre-Heat 5 6 Slave Batt -Ve / EPM2 - - Y Active Low (1sec) Pulse Output for fuel solenoids with separate pull-in coil. Y Option : 1 sec Pulse O/P 5 6 Slave Fuel + to Hold coil Here the Slave will be used to switch Batt +Ve (at perhaps > 30A, for 1 sec) to the fuel solenoid Pulse Coil. The Hold coil current would normally be within the rating of the on-board relay. Connection to an EXM2 Expansion Module The EXM2 Expansion Module should be connected as shown. It provides up to four shutdown channels and incorporates its own T0 Timer and a wealth of other features. EPM2DV or DZ Remote Start Module Fuel+ 5 Aux 16 Alarm 14 4 +Ve EXM2 Expansion Module INT 9 HoldOff Please refer to the EXM2 Data & Application Note for further information E. & O. E. The Proven Solution to Power Controls DA01EPM1-1

Capricorn Controls DA01EPM1-1 Data & Application Note Page of 8 Always check the obvious first ---- FAULT FINDING ----- EPM2 BASED SYSTEMS System correctly wired Correct EPM2 type fitted for the specific application EPM2 suitably calibrated All connections use suitably rated cables to comply with all appropriate regulations. All terminal screw connections tight. Battery(s) charged, in good condition, clean & tight connections and of the correct voltage The Module MUST be fitted in a control panel with adequate protection from extremes of Temperature, Humidity & Vibration WARNING - Incorrect wiring could damage the module i.e. - 1/ Loose connections on battery negative (term.6) & / or battery +Ve (term.4) 2/ Connecting any Active low outputs (i.e. Pre-Heat, Alarm, etc.) directly to a positive supply. 3/ connecting any positive DC outputs (i.e. Starter, Fuel, Exc.+, etc.) directly to a negative supply. 4/ connecting any DC terminals to an AC supply. Unit Dead - set will not start : Check for battery supply on term.4(b+) and term.6(b-) of the EPM2 using a DC voltmeter or by shorting term.4 to term.19 (lamp test) [EPM2DV or DV models] and observing if the Led s light. False tripping of Overspeed shutdown : (a) Module requires calibration (see below) (b) Open-circuit probe (magnetic pick-up version ONLY). Always use a screened cable where the screen is connected to Batt-Ve at the controller end only. (c) Engine over-speeding. (d) External relays and Contactor coils may require noise suppression components (see page 2). Fuel operates but no Starter : (a) Preheat timer set near maximum (50secs), wait for this time to elapse. Engine starts correctly and then shuts-down on Over-Crank : (a) (c) Short-circuit probe or probe too far from flywheel teeth (magnetic pick-up version ONLY). AC sensing version - short-circuit, open-circuit or with a voltage <50VAC or frequency incompatible with the EPM2 type fitted. No Pre-Heat output [EPM2DZ]: Pre-Heat timer (0-50 sec) set near minimum, adjust to suit application. Low oil pressure shutdown : Faulty pressure switch, incorrect type or trip setting Cooling Fault (High engine temp.) shutdown : (b) Faulty temperature switch, incorrect type or trip setting (c) Incorrect EPM2 type for use with Temperature switch fitted Charging Alternator fails to excite : (a) incorrect type of EPM2 fitted (b) rear mounted 82R resistor damaged, missing or too high a value (may require 4R on certain 12VDC Alternators). (c) charge fail (term.8) not connected to WL. connection on the charging alternator Overspeed and / or Nominal-Speed Calibration : (a) Connect a digital (or other D.C voltmeter) to term.12 (meter +) and battery negative (b) Run engine at or close to normal speed, measure & note the actual frequency (or speed using a tacho) (c) Calculate: Meter output (at required Overspeed) = OS / Nominal x 2.50 (i.e. [5Hz / 50Hz] x 2.50V = 2.85V) (d) Set Overspeed Trip pot fully anti-clockwise, adjust the Speed Cal pot until the meter reads 2.85V (e) Slowly, wind the Overspeed Trip pot clockwise until the unit (just) shutsdown on Overspeed. (f) Wind Cal potentiometer 3 turns anti-clockwise. Repeat (b). (g) Adjust Cal pot for meter output = Actual / Nominal x 2.50V (i.e. [52Hz / 50Hz] x 2.50V = 2.60V) Designed & manufactured in England by Capricorn Controls Telephone: +44 (0) 1295 22360 Fax: +44 (0) 1295 26466 E-mail: sales@ capricorn-controls.com

Page 8 of 8 SPECIFICATION Supply 12 / 24V Single range supply, operating from 6V to 30VDC Drop Out : < 4 VDC Absolute maximum supply : 40VDC Speed Sensing Magnetic Pickup Alternator 600 Hz to 6 khz at rated speed. (5V to 100Vac pk - pk) 50 Hz to 400 Hz at rated speed. (40V to 280V Rms. absolute Maximum) User Adjustable Functions Pre-Heat Timer 0-50 sec (set at minimum, unless requested otherwise) [EPM2CZ or DZ] Over-crank Delay - 24 sec (set at 15sec, unless requested otherwise) [EPM2E] Hold-Off Timer 5-25 sec (set at 25sec, unless requested otherwise) Speed Calibration --- Set Cal potentiometer for meter output = 2.50Vat Nominal Speed EPM2B, D or E] Crank Cut Threshold 15-60% of Rated Speed (set at 40% unless requested otherwise) [EPM2E] Overspeed Trip Level 102-125% of Rated Speed (set at 11% unless requested otherwise) General Ambient temperature -10 0 C to +55 0 C Operating, -25 0 C to +0 0 C Storage Construction Through panel fitting, 2mm sq. DIN standard case. Reverse screen-printed LEXAN front panel. Printed Circuit Boards are varnished as standard. Dimensions 2 Notes: 1/ Not to Scale 2/ All dimensions in mm 3/ Panel cut-out 68 x 68 mm 2 152 MOUNTING The module must be fitted into a suitable control panel that provides adequate protection from the extremes of Temperature, Humidity & Vibration. If the control panel is set-mounted then suitable Anti-Vibration mounts MUST be used Note: If specific information or a replacement unit is required, please ensure that the Serial Number of the original unit is quoted. CAPRICORN CONTROLS LIMITED INDUSTRIAL ELECTRONIC ENGINEERS SPECIALIST CONTROLS FOR ENGINE APPLICATIONS Thorpe Close, Banbury, Oxon., OX16 4SW. England Tel: +44 (0) 1295 22360 Fax: +44 (0) 1295 26466 E-mail: sales@capricorn-controls.com Web: www.capricorn-controls.com Keystart, Remote Start, Start-on-Demand, Mains Failure, Mutual Standby & Multi-set Controllers. Annunciators and Lamp Modules. Voltage, Current, Frequency, Speed, and Temperature Monitors. Timers. Transport Refrigeration Spares. Batteries, Battery Chargers and Power Supplies. Spares and Accessories. Customised Products and Bespoke Designs. E. & O. E. The Proven Solution to Power Controls DA01EPM1-1