Technical Datasheet SNK6047D00 Catalogue Page ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral Simplify your PE.N connection with ZS35-PE block connected to ZS35-BL through a premounted jumper. SNK6063F004 SNK500F0000 3D CAD outline drawings available on "Control Product 3D" portal SNC60007 F0000 Screw Clamp Terminal Blocks 35 mm² Ordering Details Color Green-Yellow Green-Yellow 3 mm.60 in Spacing Type Order Code EAN Code Pack (ing) Weight ( pce) g ZS35-PEN SNK5670R0000 3475956706 0 36.00 Declarations and Certificates CE RoHS EAC
Declarations and Certificates CE CE SND50U0* RoHS RoHS SND3049F0* EAC EAC SND600A* Explosive Atmosphere: ATEX Classification Group Category Protection Method General Information TH 35-5 IP0 TH 35-7.5, TH 35-5 NEMA Ex e: increased security In the presence of explosive dust atmosphere, terminal blocks are to be installed in certified enclosure II D The following information must be strictly adhered to in order to guarantee the terminal block electrical, mechanical and environmental performance. Protection Rail IEC 60947- Wire stripping length Denudage 7 mm 0.669 in Operating tool Torque Flat screwdriver Tete de viscouple Screw clamp Flat screwdriver 6.5 mm 0.56 in.65 N.m 3.5 N.m ± 0.5 N.m ±.33 N.m Screw rail contact (Maximum value) 5.5 mm.6 N.m 0.7 in 4. lb.in Disconnect device Material Specifications Insulating material CTI Flammability Polyamide UL94 V0 NF F 60 IF3 Connecting capacity per clamp Rigid - Solid / Stranded conductor Flexible conductor Flexible conductor with non insulated ferrule Flexible conductor with insulated ferrule Gauge Ferrule maximum outer diameter or conductor insulation maximum outer diameter A9 IEC 60947- Needle flame testec 6065--5 Screw clamp 0... AWG 0 mm 0.394 in Ferrule 4 mm 0.55 in The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to 0 mm²). Technical Datasheet SNK6047D00 ABB
Multi Connecting capacity per clamp Rigid - Solid / Stranded conductors Flexible conductors Flexible conductors with twin ferrule Don't mix solid and flexible conductors in the same clamp Don't mix solid or flexible conductors of different sizes in the same clamp The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to 0 mm²) Cross section Rated cross section 35 mm² Maximum Cross section 35 mm² Electrical characteristics Current Rated current Field and factory wiring Cat. UL 059 Factory wiring Cat. UL 059 CSA-C-. n 58 Maximum Exe current IEC/EN 60079-7 Rated short-time withstand current s (Icw) 400 A Short-time withstand current 0.5 s 5 s 0 s 30 s min Rated short-circuit withstand current UL 059 Max. current (45 temperature increase) / Max. cross section (mm²) Maximum short circuit current (s) 400 A 35 mm² Short Circuit Current Rating (SCCR) SA UL 059 supplement SCCR UL 059 With the following configurations: Suitable conductor wire range Maximum voltage Fuse class / Max. amp. Rating J T RK RK5 G CC Voltage Rated voltage IEC 60947- Rated voltage UL 059 Use Group UL 059 Rated voltage CSA-C-. n 58 Rated voltage Ex e IEC/ EN 60079-7 Rated impulse withstand voltage IEC 60947-8000 V Dielectric test voltage IEC 60947-00 V Pollution degree IEC 60947-3 Overvoltage category IEC 60947- III ABB Technical Datasheet SNK6047D00 3
Temperature range Ambient temperature min/max Storage -55... +0 C Installing -5... +40 C Service -55... +0 C -67... +30 F +3... +04 F -67... +30 F Current Derating curve for continuous service temperature Dissipated power Maximum dissipated power at rated current IEC 60947- Maximum dissipated power at maximum Exe current IEC 60079-7 Rated power dissipation at an ambient temperature of 3 C - IEC 60947-7-3 Separate arrangement / Overload and short-circuit protection Separate arrangement / Exclusive short-circuit protection fuse and 4 feed-through blocks Compound arrangement / Overload and short-circuit protection Compound arrangement / Exclusive short-circuit protection 5 fuse blocks Environmental Characteristics Additional climatic tests Dry heat Cyclic damp heat Cold Damp heat steady state IEC 60068- Compliant Temperature +00 C 96 h IEC 60068-30 Compliant Temperature +55 C Relative humidity Number of cycles ( cycle = 4h) IEC 60068- Compliant Temperature -40 C 96 h IEC 60068--78 Temperature Relative humidity Corrosion Salt mist IEC 60068- Compliant 96 h Concentration 5 % SO ISO 6988 Compliant 48 h Concentration 0. dm³ Flowing mixed gas corrosion test IEC 60068-60 Number of the test method 4 Technical Datasheet SNK6047D00 ABB
Vibrations and shocks Sinusoidal vibrations IEC 60068--6 Compliant Frequency range 0... 55 Hz Number of cycles 0 Acceleration 0 m/s² Functional random vibrations IEC 6373 Category Class B 3 axes Frequency range Acceleration Long life testing at increased random vibrations Category Class B 3 axes Shock Category Class B 3 axes ZS35-PEN Terminal Block Accessories Compatibility Some accessories may modify the terminal block's rating. See complete information in the accessories catalog page. IEC 6373 Frequency range Acceleration IEC 6373 Acceleration Description Type Order Code Pack (ing) Weight pieces g ( pce) MG-CPM 3 SNB0479R06 680 0.73 3 4 5 6 End Stops Circuit Separators Protecting Covers Protecting Cover Kits MC8 MC8-YL MC8PA UMH PROCAP8 SAT8 PR3.G PR4 PR5 PR30 PR3.Z BAZH CS-R CO KCO SNK60000R0000 SNK60004R0000 SNK69999R0000 SNK9006R0000 SNK90063R0000 SNK90066R0000 SNA64800R0300 SNA68500R00 SNA68700R00 SNA730R0500 SNA74300R700 SNK9000R0000 SNK90003R0000 SNK900604R0000 SNK90064R0000 0 0 0 5 0 0 0.00 0.00 4.00 0.0.00 6.00 78.00 95.00 700 38.00 78.00 4.00 5.0 300.00 47.80 ABB Technical Datasheet SNK6047D00 5
Contact us ABB France Electrification Products Division PG Connection 3, rue Jean Perrin F-69687 Chassieu cedex / France Tel. +33 (0)4 7 7 Fax +33 (0)4 7 935 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 0 ABB All rights reserved SNK6047D00 - PDF