FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System

Similar documents
FUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System

FUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System

Fuel Transfer Pumps DC Aluminum Gear Fuel Pump with Auto Nozzle

Aboveground Tank Equipment. Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co.

ABOVEGROUND STORAGE TANK PRODUCTS CATALOG

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products (VR-402-D) Single Wall Tank with Top Fill. 12 or 34. Pressure Vacuum Vent

ER V. CARB Phase I Enhanced Vapor Recovery AST Certified Products 8 5 (VR-402-B) Single Wall Tank with Top Fill. 26 Alarm. Pressure Vacuum Vent

LUBRICATION & FLUID HANDLING ACCESSORIES. Heavy duty knurled steel barrel with large threads for easy loading.

Model FR610C Pump Shown. Suction Pipe, 1/4 HP VAC/60 HZ Motor, and Model 807C1 Meter Installed.

AC 700 SERIES FUEL PUMPS Item code: FILLRITE-AC700

LD Series Electronic Meters

Model 1210C Battery Powered Pump Shown

Tank Filling Systems for Petroleum Products

Portable Fuel Dispensing Equipment

SERVICE QUALITY PRODUCTS INNOV ATION CUST OM ASSEMBL Y ADVANCED PRODUCT TECHNOLOGY CATALOG

Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

Overfill Prevention Valve

FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps

Fuel Dispensing & Accessory Packages

Model Model Model 3650 Model 3614

12V DC FUEL PUMPS Item code: FILLRITE-12V

FR600G Series AC Transfer Pumps

NOW UL LISTED. Patented

Model Model 815

Owner's Operation & Safety Manual SERIES 800C METER. For models 806C, 807C OUTSTANDING FEATURES

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

1618 Mechanical Gauge Installation, Operation, and Maintenance Instructions

PROFESSIONAL GRADE FUEL TRANSFER PUMPS CATALOG

Clay & Bailey Mfg. Co.

General information about underground storage tank (UST) fueling systems in every day language.

Dual wall sub-base diesel fuel tanks -

Tank Filling Systems. for Petroleum Products

RELIANCE G6200 MECHANICAL FLEET DISPENSER

Clay & Bailey Mfg. Co.

funnels, measures, gravity cocks, jerry cans and oil suction pumps...

Industrial Pumping Equipment Air-Operated Diaphragm Pumps

Bottom Load Adaptors. API Adaptors 891 Series. API Bottom Loading Adaptor L

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

M-3025CB-AV Fuel Pump

LEGENDARY PRODUCTS & CUSTOMER SERVICE PUMPS & METERS FULL LINE OF QUALITY PRODUCTS MADE IN THE USA. Look for the red label! DOING BUSINESS SINCE 1972

Emergency Shear Valves

.4 Emergency and normal vents and terminations. .1 CAN/CSA-B139-09, Installation Code for Oil Burning Equipment.

LT Series Lubricant Management System (LT-LMS)

Model Model Model

3) Storage at construction sites for refueling construction equipment; or. 4) Storage at airports as addressed in Section of this Part.

FR310V Parts List WARNING! DO NOT

Owners Installation, Operation, and Safety Manual. Series 300V. Fuel Transfer Pump. Series 300V 115 and 230 VOLT AC

Pro 30 Gas Caddy. Model FC-P30-UL Operator s Manual. JohnDow Industries, Inc. 151 Snyder Ave. Barberton, OH 44203

PEI/RP Recommended Practices for Installation of Bulk Storage Plants

92021 Automatic Tank Gauge. Features. Automatic Tank Gauge. 1/16 Accuracy. 90 Foot gauging range. Simple installation. Ground or roof reading

Model 5000 Level Controller

Congratulations PRE-OPERATION SETUP

FLUID HANDLING: Drum Filter Cart

INSTALLATION INSTRUCTIONS

Informational Handbook

DCAP Series 40-4 X X - X X X. Dual Check w/ Atmospheric Port Backflow Preventers

FUELTEC MODEL CF4.0. CRITICAL FUEL FILTRATION SYSTEM For Fuel Storage Up To 10,000 Gallons (38,000 liters)

CRITICAL FUEL FILTRATION SYSTEM For Fuel Storage Up To 10,000 Gallons (38,000 liters)

Operation, Installation, Maintenance and Repair Guide. HighFlo (HF) Control Handle. SERVICE BULLETIN SB 3097 Rev. A 6/14

Instructions for Installation, Operation, Care and Maintenance

Farm & Residential Tanks Angle skids


TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

DC 12V 8GPM Fuel Transfer Pump Kit User s Manual

Portable Filter Carts Models 5MF and 10MF

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

PREPACKAGED AVIATION FUEL TANKS AND EQUIPMENT CITY OF HORNELL, NEW YORK 82 MAIN STREET HORNELL, NEW YORK 14843

Instructions Parts List

Instructions for Installation, Operation, Care and Maintenance

M-1115S Series Fuel Pump

Industrial Generator Set Accessories

ACCESSORIES. Adaptor for ex100 spin-on ex100 UL/ULC Spin-on filter complete 10 µm, 17 gph UL/ULC Spin-on element 10micron for EX200 UL/ULC

Stay-put scuff guard helps to protect the dispensers from scratches and the breakaway during a drive-off event

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

1/2" AIR DRIVEN DIAPHRAGM PUMP

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi) " Stainless Steel " Polymer

12 Volt DC Diaphragm Pumps Series 400

07 Oil Change & Diesel Transfer Pumps

FLUID HANDLING: Drum Filter Cart

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

Emco Logo on Scuff INSTALLATION INSTRUCTIONS

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

O-Ring Swivel Joints

Fluid Dispensing Systems

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

Control valves, meters and accessories

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

Oil & Light Fluid Pumps

CONTENTS. Foreword...iii. 1. Introduction...1

Fast-Flo Pump INSTRUCTIONS-PARTS LIST. Table of Contents 1:1 RATIO

HIGH PRESSURE SPRAY GUNS &ACCESSORIES

Calcium Chloride Pump

EZ-View. Flow Meters ISO CERTIFIED 9001

Operating instructions Form no safety definitions

CAT 401. North American Version PUMPS & ACCESSORIES

Transcription:

FUEL DISPENSING SYSTEMS Component Details SE-27 12V DC - 15 GPM Metered Tank-top Dispensing System 12V DC Electric Pump - 1 Inlet - 3/4 Outlet 3-Wheel Mechanical Meter 1 Automatic Nozzle, Swivel & Hose 40 GPM Particulate Filter - 30 Micron 2 - Emergency Vents - MNPT - 16 oz Pop-up Leak Gauge Swing-arm or Clock Level Gauge Overfill Prevention Valve Atmospheric Vent with Pipe Drop Tube - Pump Suction Pipe - 3 Lift Spill Bowl or Remote Fill Maximum tank diameter 64 Proudly made in America

12V DC Electric Pump - 1" Inlet - 3/4" Outlet This industry standard DC pump dispenses up to 15 GPM (57 LPM). The FR1204G is ideal for pumping gas, diesel fuel and kerosene. With an amp draw that's easy on your DC power source. Explosion proof UL/cUL listed 1/4 HP motor. The FR1204G is a pump only unit allowing you to customize your own system. Please see our full line up of meters and accessories to complement your system. Features & Benefits Up to 15 GPM 1/4 HP motor UL/cUL listed motor Compatible with Diesel, Gasoline, Kerosene, E15, and Biodiesel up to B20 2 year warranty Built in strainer 2 in. threaded base for tank mounting Heavy duty cast iron construction Cast bronze rotor with bronze rotary vanes http://www.fillrite.com/index.cfm/products/productdetail/?p=105&ps=80 1/4

3-Wheel Mechanical Meter The 807C Mechanical flow meter has a large easy to read display, flow ports can be positioned vertically or horizontally, UL/cUL listed, handles fluid of any viscosity, rated for Gasoline, Diesel, Kerosene, mineral spirits, Stoddard solvents and heptane. Fill Rite meters provide precision and durability in a cost effective design. The 807C is a 3 wheel mechanical meter designed for transfer pumps with a flow rate of 5 to 20 GPM. this meter has a 3/4 in. inlet and outlet. Features & Benefits +/ 1% accuracy UL/cUL, CE listed 5 20 GPM 50 PSI 3/4 in. inlet, 3/4 in. outlet Large easy to read display NPT threads tp://www.fillrite.com/index.cfm/products/productdetail/?p=165&ps=91 1/4

3/4" Automatic Nozzle, Swivel & Hose, Gas & Diesel The N Series nozzles are well suited for a broad range of high flow fueling applications from farm tractors and combines, heavy earth moving equipment, fleet re fueling, to above ground storage tanks and portable truck mounted fueling operations. This rugged series of automatic nozzles will provide years of service with minimal down time and quick fueling. Features & Benefits Compatible with diesel UL listed 3/4 in aluminum nozzle 3/4 in NPT F outlet Automatic shut off 50 PSI working pressure Green body cover to indicate diesel compatibility Heavy duty hanging hook compatible with all Fill Rite products Convenient one finger hold open clip to set flow rate ttp://www.fillrite.com/index.cfm/products/productdetail/?p=295&ps=120 1/4

3/4" Swivel & Hose Multi Plane, Full 360 spherical rotation for easy movement of the nozzle. Features & Benefits Double O ring Seals at each Swivel Provide Long Life at Low Temps ( 40 F/C) Compatible with unleaded Gasoline, Diesel & Ethanol Blends through E10 Dispense Diesel Fuel, Gasoline, Grease Kerosene and Petroleum Oils. The Fill Rite hose is a blend of Nitrile and PVC external materials provides rugged protection against cuts, abrasions, snags. Puncture Resistant. Features & Benefits 3/4 x 12' fuel transfer hose Dispense diesel fuel, gasoline, kerosene, and petroleum oils Neoprene exterior Designed for use with all electric pumps High quality Nitrile inner tube

18 GPM Particulate Filter - 10 Micron & Filter Head Particulate Fuel Dispenser Filter is designed with resin impregnated cellulose media for the removal of dirt, rust and microbes. Features & Benefits 10 Micron Filter 50 psi 18 gpm 1 12 UNF Compatible with gasoline, diesel, ethanol blends up to 15% and ultra low sulfur diesel

Emergency Vents - MNPT - 16 oz UL Listed Emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire. Emergency vents must be used in conjunction with a normal vent. Correct application of this vent requires proper vent size and selection for the tank system in order to meet the specific venting capacity. Code Compliance: API 2000 International Fire Code National Fire Code of Canada NFPA 1, 30, 30A, 31, 37, 110 PEI RP200 & PEI RP800 Underwriters Laboratories Inc. - UL-142, UL-2085 & UL- 2244 Underwriters Laboratories of Canada - CAN/ULC S601-07, CAN/ULC S602-07 & CAN/ULC S652-08 California Air Resource Board (CARB) Phase 1 Enhanced Vapor Recovery (EVR) AST Certified Products (VR-402-B) Fig. 244OM WARNING: DO NOT FILL OR UNLOAD FUEL FROM A STORAGE TANK UNLESS IT IS CERTAIN THAT THE TANK VENTS WILL OPERATE PROPERLY. Emergency vents are designed only for use on shop fabricated atmospheric tanks which have been built and tested in accordance with UL 142, NFPA 30 & 30A, and API 650 and in accordance with all applicable local, state, and federal laws. In normal operation, dust and debris can accumulate in vent openings and block air passages. Certain atmospheric conditions such as a sudden drop in temperature, below freezing temperatures, and freezing rain can cause moisture to enter the vent and freeze which can restrict internal movement of vent mechanisms and block air passages. All storage tank vent air passages must be completely free of restriction and all vent mechanisms must have free movement in order to insure proper operation. Any restriction of airfl ow can cause excessive pressure or vacuum to build up in the storage tank, which can result in structural damage to the tank, fuel spillage, property damage, fire, injury, and death. Monthly inspection, and immediate inspection during freezing conditions, by someone familiar with the proper operation of storage tank vents, is required to insure venting devices are functioning properly before filling or unloading a tank.

Leak Gauge - Pop-Up Top mounted liquid leak gauge that can measure from 6" to 170" in depth. Gauges are custom made in house to fit your tank. This gauge is designed to monitor either the interstitial space of a double wall containment system, or it can mount into an external monitoring pipe. Calibration: Consists of 3 pieces. Outer plastic piece, inner plastic piece, and a piece of paper in between. Red Lock Nut: HDPE Plastic. This gauge is a simple visual tool. If the red indicator rises into the viewing window, it is indicating that there is a leak occurring in the double wall containment system. Bushing: Aluminum bushing, can be 2 or 1.5. Once installed, simply view the calibration to monitor the interstitial space. The indicator is not calibrated. It simply indicates leak or no leak. Internal Rods: Standard construction is aluminum rods. Additional Options Leak Union: Compression union Audible Alarm Accessory: This feature can turn the mechanical gauge into an audible Hi or Lo level alarm. Gauge Guard: A cover that protects the exposed plastic components on top of the gauge. Environmental Protection The Leak gauge is officially approved for use in double wall containment systems by several state environmental protection agencies. Float: HDPE Plastic

Level Gauge - Swing Arm Top mounted liquid level gauge that can measure from 6" to 144 in depth. This gauge is a simple volume reading tool. The top of the red indicator is an indication of approximate fuel level in the tank. Once installed, simply view the calibration to monitor tank level. Indicator is calibrated in eighths of a tank on one side, and quarters of a tank on the other. Calibration: Consists of 3 pieces. Outer plastic piece, inner plastic piece, and a piece of paper in between. Red Lock Nut: HDPE Plastic. Bushing: Aluminum bushing, can be 2 or 1.5. Gauges are custom made in house to fit your tank. Can also accommodate for double walls and pipe risers. HDPE Float: High Density Polyethylene Plastic. Additional Options Audible Alarm Accessory: This feature can turn the mechanical gauge into an audible Hi or Lo level alarm. LED At-A-Glance Accessory: This feature can give mechanical gauge remote reading capability. Gauge Guard: A cover that protects the exposed plastic components on top of the gauge. Internal Rods: Standard construction is galvanized steel rods with brass rivets. These replacement parts are available. Red HDPE Plastic Nut Duro Nitrile Gasket Plastic cellulose acetate inner and outer calibration Aluminum Lock Nut Glass inner calibration

Overfill Prevention Valve The overfill prevention valve is installed at the fill port of a storage tank. Used in a pressurized tight fill application, the valve helps prevent tank overfills by closing when the liquid level reaches a pre-set warning level (90-95% full). The valve is installed through a 4" or 6" threaded opening and has a built-in bleed hole that allows the fill hose pressure to be relieved after the valve closes. This bleed hole also provides anti-siphon protection for the valve. When installed to manufacturer requirements, the overfill prevention valve can eliminate hazardous liquid spills. The valve can be used in conjunction with AST spill containers or remote fill boxes for added spill protection. All models are supplied with an adaptor to mount an aluminum drop tube. A test mechanism is also sold separately if needed. The test mechanism allows a technician to pull on the test line at any time during the filling process to actuate the float and stop the filling process. This allows a technician to verify the valve is working properly. Features The 3" valve can be used with 6" Sch. 40 or 80 pipe. The 2" valves can only be used with 4" Sch. 40 pipe. Construction Details Anodized aluminum body Brass/stainless steel internal components Stainless steel linkage Failure to follow any or all of the warnings listed below may render the valve non-functional and could result in an accidental product spill, property damage, fire, explosion, injury or death. Warnings and Cautions 5 PSI & 5 GPM is the minimum flow requirement for valve operation. Valve will NOT function in gravity fill applications. Maximum viscosities (in centistokes): 2" Valve-150, 3" Valve-60. Flow rate of the 2" valve is 350 GPM maximum flow (183 GPM @ 10 PSI pressure drop). The 3" valve is 800 GPM maximum flow rate (566 GPM @ 10 PSI pressure drop). Once closed the valve will allow fl ow of less than 2% of max fl ow rate to relieve fill line pressure. A tight fill is required for the valve to operate. Do not substitute any other fill adaptors for the special adaptor supplied. The valve must be used with clean product. Debris from products such as contaminated used oil may cause the valve to function improperly. These valves are rated for a maximum pressure of 100 PSI. Not suitable for motor oil or other heavy oils. Consult Morrison Bros. Co. for product compatibility with the valve. Code Compliance ULC, NFPA 30, 30A, UFC, IFC and PEI /RP200, PEI /RP600, Florida DEP EQ356, CARB VR 402A

Drop Tube & Normal (Mushroom) Vent with Pipe The drop tube directs product flow to liquid level when filling a storage tank. The drop tube prevents free fill and reduces agitation of liquid when filling. The flanges fits between tight fill adaptor riser pipe. The tube extends to near bottom for submerged fill. All drop tubes are extruded aluminum. The 2 and 3 drop tubes can also be attached to the AST Overfill Prevention Valve. Drop tube length determined by tank diameter. Mushroom style free flow vent Stainless-steel mesh screen. Domed vent top prevents tank contamination from entering vent lines. NPT threads Cast iron, zinc plated 2" diameter galvanized steel vent pipe Length determined by tank volume/size

Spill Bowl Tank top spill containers are designed tocontain small spills that occur at the fill point on aboveground storage tanks. Features 3½ gallon (13.25 liters) capacity Hinged cover is lockable with a padlock Centered connection Female threaded inlet and outlet Includes removable screen for use as used oil collection point, male threads Construction Details 16 gauge spun steel, powder-coated white body and cover Capacity: 3.5 Gallons Mounting Connection: Female Mounting Location: Center Size: 2 NPT threads Drain: No Screen: No Height: 8 Width: 17.25 Body diameter: 13.14 517 Certifications & Listings Florida DEP EQ 345 Meets the new and revised requirements for CAN-ULC-S663-11 (effective September 25, 2015)