INNOVATIVE MOBILITY. ATC Service Desk. Switch Refit

Similar documents
OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH)

Brake and Tail Light Kit Workman 1100/2100 and Twister Utility Vehicles

CASRE Disconnect Arm Retro Instructions 2/23/2016

2003 Chevrolet Impala LS

INSTALLATION INSTRUCTION

Intelligent Lift Interlock ILISCT511-A (Manual Lift Door) Ford Transit Connect

Hunter Automatics HA-8. Installation Manual

INNOVATIVE MOBILITY ATC CUV TROUBLESHOOTING GUIDE. Shipping/Mfg. Location 4654 East Markle Road Markle, IN

Electronic Entry Device Installation Instructions

Side Channel Mag Drive (SCM) Assembly

KT101 Series Governor System Installation Kit Cummins 4B(T) / 6B(T) With CAV/DPA Pump

Mag-Hytec. Installation Recommendations FORD 4R100 / E4OD TRANSMISSION PAN

INSTALLATION INSTRUCTIONS

JK8 Body Kit KIT CONTENTS 1 K

!!!! ! Lock housing dimensions: 230mm L x 44mm W x 44mm D! Receptacle housing dimensions: 120m L x 44mm W x 44mm D. ! Surface mount housing for LK120

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Installation Guide. Electronic Entry Device. LA GARD Basic & Gard Series

KT145 Series John Deere 6076 with Nippondenso Inj. Pump

CHEVORLET IMPALA

Opening Quality Doors Around The World. Installation Instructions Bi-Parting Freight Doors - Q Style (Power and Manual)

ELECTRONIC ENTRY DEVICE INSTALLATION INSTRUCTIONS FOR BASIC AND GARD SERIES

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY

KT230 Series Caterpillar 3406 Governor System Installation Kit

B CW POWER RELAY

TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall)

Solenoid valve. Solenoid Coil

Installation Instructions For Motor Control Center (MCC) Units

USER MANUAL. Item: #13246 Stand-Aid Lift. Drive Medical Design and Manufacturing Push Handle. Base Width Adjustment Handle.

Self-Deploying Rail Kit OEM INSTALLATION MANUAL

Power In - Pathways Technology Wall

Installation Instructions

INSTALLATION INSTRUCTIONS

MSD Blaster Ignition PN 5900

LOW MOUNT SPA COVERLIFT Installation Instructions

R-SE JK 4 DOOR Step Slider Install Instructions. *If any parts listed are missing or damages please call prior to install.

TURN-TiLT WiNDOWs A11.16 CHRONO ACCessORies

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

SAFETY REASONABLE EFFORT. ANY BINDING, SAGGING, LOOSE HINGES, OR DAMAGED HINGES MUST BE REPAIRED BEFORE CONTINUING WITH THIS INSTALLATION!

3/19/2017 9:49 AM. Transmission Replacement. Tools Required ^ J B Cooler Quick Connect Tool ^ J Transmission Jack Adapter

Keeping You Cool Under Pressure

MIC210 Electric Farm Conversion Instructions

CAMSHAFT TIMING CHAIN, SPROCKET, AND TENSIONER REPLACEMENT

DEMA 652 DUO-FEED INSTALLATION INSTRUCTIONS

2001 Dodge Dakota ENGINES 4.7L V8

SHIELDS COMPANY PERMANENT MAGNETIC TOW SWEEPER MODEL MKS4000

Installation Instructions QUARTER STICK Fits: 2 Speed (Powerglide) or 3 Speed (Turbo-Hydramatic)

TS93 EMF T/PT/TDE. Surface applied door closer

Car Gate - Ratio Installation Instructions.

OPERATING INSTRUCTIONS

Two Function Remote Control System (Model RC192)

INSTALLATION INSTRUCTIONS FOR PART TRIGGER TRIGGER

Mustang. Installation Manual. Revision 11/16/10

PD10-M-RIM INSTALLATION INSTRUCTIONS. The PD10-M-RIM is a storefront grade 1 exit device equipped with motor drive latch retraction.

Table of Contents. 1.0 INFORMATION 1.1 Introduction. 1.2 Product Information. 2.0 INSTALLATION 2.1 Pre-Installation. 2.2 Component Installation

= Experienced

Electric Lock Part List

Ford F150 SuperCab Ford F150 SuperCrew

Installation Instructions for the Plug & Play Remote Start Package (EVOCHR5)

Storage Basket and Clamp Vertical Oxy Holder and Clamp Pogo IV Pole / Stand - Heavy Base Provita Smart IV Stand IV Handle and Clamp

SWING DOOR SOFT ENCLOSURE (part# 16733)

Installation Instructions Lockey TB 250/450/650 Plus Hydraulic Pedestrian Gate Closer (with hydraulically adjustable closing speed)

USER MANUAL. Item: #13246 Stand-Aid Lift. Drive Medical Design and Manufacturing

655 South Lincoln Avenue / San Bernardino CA Phone / Fax / Web address: globalwest.net

INSTALLATION GUIDE. AMP RESEARCH TECH SUPPORT (Press 2) Monday - Friday, 6:00 AM - 5:00 PM PST

Handy Lift LT Owners Manual

SPACESAVER EC-300 A ELECTRICS

Homebrew Travel Antenna

BUICK SKYLARK & GS CHEVROLET CHEVELLE & MONTE CARLO PONTIAC GTO & LEMANS OLDSMOBILE CUTLASS & 442

7100SZ Series SafeZone Installation and Instruction Manual

UNIVERSAL PRODUCTION EDGE BELT SANDERS

Conversion Kit for HP1200 Cartridge

SLP PIPE INSTALLATION INSTRUCTIONS #09-9 & # & NEWER POLARIS INDY 650 & RXL PIPE SET EFFECTIVE 6-92

Dfuser T/C Lock Override with LED

MSD 7AL-3, Ignition Control PN 7230

NECO Pumping Systems

TOYOTA im INTERIOR LIGHT KIT Preparation

Handy Lift HD Owners Manual WARNING. BURR 500 lb. Capacity Handy Lift HD PN (40 ) PN (45 ) PN (50 )

3-5 Hours Professional installation recommended

ADDICTIVE DESERT DESIGNS

GateCrafters Automatic Gate Lock Instruction Manual GCLOCK

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Three Function Remote Control System with Alarm (Model RCA-3)

Castle Model TSM-21 Standard Screw Pocket Machine

WIRE SYSTEM PRO15 ULTRA SMALL 15 FUSE 24 CIRCUIT 118 TERMINAL PANEL WIRE SYSTEM

ACCEL/DFI 6A Sportsman Electronic Ignition Control Module for Distributor Equipped Engines

C3000 SIGNAL TRANSMITTER. Introduction

KOMBI 3 OPERATION. Fleet Line Markers Ltd PREPARING THE KOMBI 3 FOR USE

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

Lumenition Optronic Ignition System PMA 50 Power Module. Fitting Instructions

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS

GAS CONVERSION KIT INSTALLATION INSTRUCTIONS

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

Hinge technology for face frame cabinetry: Optimat

DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size

WARNING! THIS SHIFTER IS FOR RACING USE ONLY. NOT FOR STREET USE!

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

HYFIRE 6AL2 ELECTRONIC IGNITION CONTROL

Magnetic Door Jamb Switches (Ground Style) Installation Instructions

Transcription:

ATC INNOVATIVE MOBILITY Switch Refit Contents Tilt Switch Installation... 3 Pan In Limit Switch Installation... 4 Pan Out Limit Switch Installation... 5 Pan Up Limit Switch Installation... 6 Door In Limit Switch Installation... 7 VER: 10/9/2017

Tilt Switch Installation Mount new mechanical switch to H hinge as shown. Insure bracket angle will align with target dome head bolt on door hinge plate when installed. Cut and terminate the incoming switch wire, terminate black lead and use white wire to connect to new switch. Add a length of purple with white wire if needed. The switch works by grounding to the dome head bolt when the door closes. The lift out button on the remote will not operate while the switch is grounded and the door is closed. H-Hinge use this lead terminate this lead Old Magnetic Switch Existing Mag Switch Wires 2 Technical Service: (877) 291-6309 www.atconversions.com service@atconversions.com

Pan In Limit Switch Installation Mount to swing arm support as shown. Manually move the pan in and mark on the swing arm the location of where the switch contacts the swing arm. This will be the location of the target bolt. Drill and tap hole( 1/4-20) for bolt, add extra ground wire to the target bolt and connect to the out limit switch target bolt. Cut and terminate the incoming switch wire, terminate black lead and use white wire to connect to new switch. Add a length of blue with black wire if needed. The switch works by grounding to the target bolt when the pan closes. This switch can be adjusted in or out to insure pan is all the way in. Use caution not to adjust the pan in too far and cause damage. swing arm support Extra Ground (going to pan out limit switch target bolt) Technical Service: (877) 291-6309 www.atconversions.com service@atconversions.com 3

Pan Out Limit Switch Installation Mount to pan support as shown. Mount the target bolt bracket and bolt to the swing arm support as shown. Connect target bolt to extra ground wire coming from the Pan In Limit target bolt. Cut and terminate the incoming switch wire, terminate black lead and use white wire to connect to new switch. Add a length of green with black wire if needed. The switch works by grounding to the target bolt when the pan goes out. This switch can be adjusted in or out to insure pan is all the way out and clear of the floor pan, it also allows the pan to come down when actuated. Use caution not to adjust the pan out too far and cause damage. We recommend manually moving the lift in or out while installing the switch. 4 Technical Service: (877) 291-6309 www.atconversions.com service@atconversions.com

Pan Up Limit Switch Installation Mount to existing switch bracket on the lift post as shown. Manually raise the lift pan up until it stops and the hydraulics dead head. Mark the location of where the switch bolt touches the lift pan.. This will be the location of the target bolt. Drill and tap hole (1/4-20) for bolt, add extra ground wire to the target bolt, and connect to the pan in an unused area. Cut and terminate the incoming switch wire, terminate black lead, and use white wire to connect to new switch. Add a length of pink with black wire if needed. The switch works by grounding to the target bolt when the lift pan is up. This switch can be adjusted up or down to insure pan is all the way up. Insure pan is up enough not to contact the floor pan and just touches the dry slide. existing bracket Technical Service: (877) 291-6309 www.atconversions.com service@atconversions.com 5

Door In Limit Switch Installation Mount to swing arm support as shown. Manually close the door and mark the location of where the switch contacts the door. This will be the location of the target bolt. Drill and tap hole (3/8 16) for switch target bolt. Cut and terminate the incoming switch wire, terminate black lead and use white wire to connect to new switch. Add a length of purple with black wire if needed. The switch works by grounding to the target bolt when the door closes. This switch can be adjusted in or out to insure door is closed all the way in. Use caution not to adjust the door in too far and cause damage. swing arm support ground target bolt on door 6 Technical Service: (877) 291-6309 www.atconversions.com service@atconversions.com