OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100

Similar documents
Pump Specifications 250 Series Submersible Sump / Effluent Pump

Pump Specifications 290 Series 3/4 hp Submersible Effluent Pump

Pump Specifications 280 Series 1/2 hp Submersible Effluent Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

Pump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump

Pump Specifications FL100 Series Submersible Effluent Pump

Pump Specifications FL150 Series Submersible Effluent Pump

Pump Specifications 405 Series Commercial Drain Pump (High-Temp)

Pump Specifications. ELV Series Submersible Sump Pump with OilTector Control. ELV250 1/3 hp ELV280 1/2 hp ELV290 3/4 hp

Pump Specifications. Omnivore 2HP Submersible Grinder Pumps LSG200-SERIES (SINGLE STAGE) LSGX200-SERIES (TWO STAGE)

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

LITERS PER MINUTE TOTAL HEAD IN FEET TOTAL HEAD IN METERS GALLONS PER MINUTE

LITERS PER MINUTE GALLONS PER MINUTE

SKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:

SPD50H/100H. Performance Data SPD100H SPD50H. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

SKHS SERIES 2 HP 1-1/2 HP 1 HP 1/2 HP CAPACITY-U.S. G.P.M.

HYDROMATIC SKHS SERIES SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

HYDROMATIC SPD50H/100H SUBMERSIBLE HIGH HEAD, DOUBLE SEAL EFFLUENT

Boand Arena Septic to Sewer Duplex Grinder Pumps (Commercial) Engineering Analysis

HYDROMATIC SK75/100 SUBMERSIBLE SEWAGE EJECTOR

HYDROMATIC SPX50/SPX50H EXPLOSION PROOF, SEWAGE EJECTOR

Pump Specifications Series. Pre-assembled Duplex Sewage System 30 x 36, 110 Gallon

HYDROMATIC HE8/HE12/HE20/HE25/ HE30/HE35/HE50 HIGH HEAD FILTERED EFFLUENT

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

KW Submersible, Single-Vane Impeller

GR NDER PUMPS. Technical Catalog

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

GR NDER PUMPS. 505 Woodland Rd., Mt. Pocono, PA Phone: (570) Fax: (570)

Electric Submersible Pumps

MYERS 3MW VERTICAL DISCHARGE WASTEWATER PUMPS. Sewage, high-capacity sump, effluent

MYERS MODELS 4R AND 4RX

Series MSC Sewage Chopper Pumps

KG(X)3. Grinder Pumps. 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Total Head (FT) Capacity (GPM)

ECC ECC Flow(USGPM) Sump & Effluent De-watering Drainage. Phase Voltage Approx Weight (lbs)

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

Commercial Sewage & Waste Water Systems

MYERS MODELS 4V AND 4VX

50 Hz Products. Commercial Duty Pumps Heavy Duty Solids Handling Pumps Grinder Pumps Lift Station Accessories. Trusted. Tested. Tough.

MYERS MODELS 4RC AND 4RCX

MYERS 4VCDP. 4" Solids Handling

Contents Project: Model: Chk d: Date:

Installation Manual. Q Series Quadplex Grinder Systems. Contents

Series 8SHDU. Specifications: Series: 8SHDU 25-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3.50" Spherical Solids Handling

MYERS MODELS 4VC & 4VCX

JDL SYSTEMS Submersible Sump / Sewage Pumps Table of Contents Project: Model: Chk d: Date:

MYERS MODELS 6VC & 6VCX

Your Premier Pump Choice!

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

Series 6SHV. Specifications: Series: 6SHV 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

KGX2-21. Grinder Pumps. 2HP Dual Seal Grinder Pump, External Start (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve

DSZ3. EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

Series 6XSHD. Specifications: Series: 6XSHD 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

P U M P. Pumps for Municipal and Commercial Operations

DARTMOUTH COLLEGE DESIGN February 15, 2006 & CONSTRUCTION GUIDELINES

Series SFA Hz, 3450RPM. Submersible. ADI Water Garden Pumps

Series 4XSHV. Specifications: Series: 4XSHV , 3450RPM, 60Hz 2-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling

4400JF (120V) Aerating Fountain Specifications

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

Series: PF33, PF33X, PF33X-30 PF33A, PF33AX, F33AX-30, PF33VF, PF33VFX, PF50X, PF50AX, PF50VFX

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

Series 6SHM. Specifications: Series: 6SHM 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

8400JF (240V Single Phase) Aerating Fountain Specifications

ESE Series Cast Iron Sewage Pumps

CPG 2HP Grinder Series

SUBMERSIBLE PUMP HSE RANGE

Series 4XSHM 18 Frame Driver 3" Spherical Solids Handling

Series 4XSHD. Specifications: Series: 4XSHD 3-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

Turbine STEP System SIMPLEX OR DUPLEX

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

50 Hz Products. Your Peace of Mind is Our Top Priority. Utility Pumps. Sump / Effluent Pumps. Sewage Pumps. Grinder Pumps. Specialty Products

2014 Auxiliary Catalog. Controllers Packages Systems Accessories. 37 Forestwood Dr., Romeoville, IL

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

Series 4SHM. Specifications: Series: 4SHM 3-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling. Solids Handling Submersible Pumps

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

MODELS WGL20, WGL20H and WGL20F

Access Riser Fits PRO370 and PRO380 Series

Section 200 Page 1 Effective: January 15, 2013 Supersedes: June 1, 2012

Technical Data 5430 M & W SUBMERSIBLE SOLIDS HANDLING PUMPS

2460 / 2472 / Series Simplex Grinder Systems

D51 D61 D71 D91 Series

CARRY PUMPS CARRY MANUFACTURING, INC.

Complete Grinder Package Offering

Wilo Helix Vertical Multi-Stage, High Pressure Pumps. Engineering Specification

4-Way Mixing Panel Submittal - Page 1 of 6

Transcription:

OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100 The Oil Smart OSS-100 System, when combined with a manual sump pump, will automatically pump water without the risk of pumping oil into the environment. Additionally, the system alerts maintenance or building personnel in the event of a high oil or high water condition. Installation of the OSS-100 allows you to comply with Elevator Code ASME A17.1 and State/Federal regulations while reducing the risk of adverse publicity, fines and expensive cleanup costs. The system is a plug and play system that includes the Oil Smart Pump Controller, Model #OSS20PBPR6 and the Oil Smart Alarm, Model #OSA-05. OSS-100 Pump not included Oil Smart Alarm (OSA-05) Liquid Smart Alarm Switch - HIGH LIQUID - Oil Smart Pump Switch - ON - - OFF - Applications: Elevator Sumps Transformer Containment Areas Underground Vaults Manufacturing Facilities Any application where there is a need to remove water while containing oil OSS-100 Features: Plug & Play for Easy Installation Includes Oil Smart Pump Switch (OSS20PBPR6) with 20 cord and piggy back plug Includes Oil Smart Alarm (OSA-05) with 10 power cord and Liquid Smart Alarm Switch Pump control and alarm components differentiate between oil and water 120VAC Single Phase, 60Hz UL/CSA Certified for the United States and Canada Alarm Visible Indicators: High Red Beacon Alarm Light, Yellow Light for Oil, White Light for Water, Alarm Test and Silence Buttons High 85 Decibel Audible Alarm Complete Panel Remote Monitoring Dry Contacts: Oil, Water, High Liquid www.seewaterinc.com or www.oilsmart.org 951.487.8073 888.733.9283 Email: Carlos@CarlosRivera.org 121 North Dillon Street San Jacinto, CA 92583 P.O. Box 1269 San Jacinto, CA 92581 carlosrivera.org

Pump Specifications 250 Series Submersible Sump / Effluent Pump 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

250-Series Dimensional Data 250_P2 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

250-Series Electrical Data MODEL HP VOLTAGE PHASE FULL LOAD AMPS LOCKED ROTOR AMPS THERMAL OVERLOAD TEMP STATOR WINDING CLASS CORD LENGTH FT DISCHARGE AUTOMATIC 250 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 251 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 253 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 257 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 NO MANUAL YES INTEGRAL FLOAT YES PIGGY BACK FLOAT YES INTEGRAL VERTICLE FLOAT 250-Series Cord Length Options* Model 10' 25'(-2) 35'(-3) 50'(-5) 250 Standard Optional Optional Optional 251 Standard Optional Optional Optional 253 Standard Optional Optional N/A 257 Standard Optional N/A N/A 10' cord length standard on all models. For optional lengths, add -2, -3 or -5 suffix to model number. Example: for model 250 with 35' cord. Order 250-3 WARNING: *Always use a replacement power cord assembly of the same length and type as originally installed on the Liberty product. Using a cord of improper gauge or length may lead to exceeding the electrical rating of the cord and could result in death, injury, fire or other significant failure. 250_P3 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

250-Series Technical Data IMPELLER VORTEX ENGINEERED POLYMER SOLIDS HANDLING SIZE ½ PAINT MAX LIQUID TEMP MAX STATOR TEMP THERMAL OVERLOAD POWER CORD TYPE MOTOR HOUSING / VOLUTE SHAFT HARDWARE ORINGS SEAL WEIGHT POWDER COAT 60 C 140 C CLASS B 130 C/ 266 F 105 C / 221 F SJTW (10ft & 25ft models) SJTOOW (35ft & 50ft models) CLASS 25 CAST IRON STAINLESS STAINLESS BUNA N ENGINEERED DOUBLE LIP SEAL WITH STAINLESS STEEL SPRINGS 23 LBS 250-Series Specifications 1.01 GENERAL: The contractor shall provide labor, material, equipment, and incidentals required to provide (QTY) centrifugal pumps as specified herein. The pump models covered in this specification are Series 250 single phase pumps. The pump furnished for this application shall be model as manufactured by Liberty pumps. 2.01 OPERATING CONDITIONS: Each submersible pump shall be rated at 1/3 hp, 115 volts, single phase, 60 Hz., 3450 RPM. The unit shall produce G.P.M. at feet of total dynamic head. The submersible pump shall be capable of handling effluent with 1/2 solid handling capability. The submersible pump shall have a shut-off head of 23 feet and a maximum flow of 44 GPM @ 5 feet of total dynamic head. The pump shall be controlled with: A piggy back style on/off float switch. An integrally wired on/off float switch. A Vertical Mechanical Float (VMF) type on/off switch. A NEMA 4X outdoor simplex control panel with three float switches and a high water alarm. A NEMA 1 indoor simplex control panel with three float switches and a high water alarm. A NEMA 4X outdoor simplex control panel with four float switches and a high water alarm. A NEMA 1 indoor simplex control panel with four float switches and a high water alarm. A NEMA 4X outdoor duplex control panel with three float switches and a high water alarm. 250_P4 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

A NEMA 1 indoor duplex control panel with three float switches and a high water alarm. A NEMA 4X outdoor duplex control panel with four float switches and a high water alarm. A NEMA 1 indoor duplex control panel with four float switches and a high water alarm. 3.01 CONSTRUCTION: Each centrifugal effluent pump shall be equal to the certified Series 250 SERIES pumps as manufactured by Liberty Pumps, Bergen NY. The castings shall be constructed of class 25 cast iron. The motor housing shall be oil filled to dissipate heat. Air filled motors shall not be considered equal since they do not properly dissipate heat from the motor. All mating parts shall be machined and sealed with a Buna-N o-ring. All fasteners exposed to the liquid shall be stainless steel. The motor shall be protected on the top side with sealed cord entry plate with molded pins to conduct electricity eliminating the ability of water to enter internally through the cord. The motor shall be protected on the lower side with an engineered double lip seal with stainless steel springs. The pump shall be furnished with stainless steel handle. 4.01 ELECTRICAL POWER CORD The submersible pump shall be supplied with 10, 25, 35, or 50 feet of multiconductor power cord. It shall be cord type SJTW, or SJTOOW capable of continued exposure to the pumped liquid. The power cord shall be sized for the rated full load amps of the pump in accordance with the National Electric Code. The power cable shall not enter the motor housing directly but will conduct electricity to the motor by means of a water tight compression fitting cord plate assembly, with molded pins to conduct electricity. This will eliminate the ability of water to enter internally through the cord, by means of a damaged or wicking cord. 5.01 MOTORS Single phase motors shall be oil filled, permanent split capacitor, class B insulated NEMA B design, rated for continuous duty. At maximum load the winding temperature shall not exceed 130 degrees C unsubmerged. Since air filled motors are not capable of dissipating heat they shall not be considered equal. The pump motor shall have an integral thermal overload switch in the windings for protecting the motor. The capacitor circuit shall be mounted internally in the pump. 6.01 BEARINGS AND SHAFT Upper and lower ball bearings shall be required. The bearings shall be a single ball / race type bearing. Both bearings shall be permanently lubricated by the oil, which fills the motor housing. The motor shaft shall be made of 300 or 400 series stainless steel and have a minimum diameter of.311". 7.01 SEALS The pump shall have an engineered double lip seal with stainless steel springs. The motor plate / housing interface shall be sealed with a Buna-N o-ring. 8.01 IMPELLER The impeller shall be engineered polymer, with pump out vanes on the back shroud to keep debris away from the seal area. It shall be threaded to the motor shaft. 9.01 CONTROLS All pumps can be supplied with a CSA and UL approved VMF type switch, an integrally wired wide angle tilt float switch, or piggy back type wide angle tilt float switches. The piggy back style switches are equipped with a plug that allows the pump to be operated manually without the removal of the pump in the event that a switch becomes inoperable. Manual pumps are operable by means of a pump control panel. 250_P5 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

10.01 PAINT The exterior of the casting shall be protected with Powder Coat paint. 11.01 SUPPORT The pump shall have cast iron support legs, enabling it to be a free standing unit. 12.01 SERVICEABILTY Components required for the repair of the pump shall be shipped within a period of 24 hours. 13.01 FACTORY ASSEMBLED TANK SYSTEMS WITH GUIDE RAIL AND QUICK DISCONNECT DISCHARGE Guide factory mounted rail system with pump suspended by means of bolt on quick disconnect which is sealed by means of nitrile grommets or o-rings. Discharge piping shall be schedule 80 PVC and furnished with a PVC shut-off ball valve. The Tank shall be wound fiberglass or roto-molded plastic. An inlet hub shall be provided with the fiberglass systems. Stainless steel Guide Rail Zinc plated steel Guide Rail "diameter of basin size "height of basin size "distance from top of tank to discharge pipe outlet Fiberglass cover Structural foam polymer cover Steel cover Simplex System with Outdoor panel and alarm Duplex System with Outdoor panel and alarm Separate Outdoor Alarm Remote Outdoor Alarm 14.01 TESTING The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity, moisture content and insulation defects. The motor and volute housing shall be pressurized, and an air leak decay test is performed to ensure integrity of the motor housing. The pump shall be run, voltage current monitored, and the tester checks for noise or other malfunction. 15.01 QUALITY CONTROL The pump shall be manufactured in an ISO 9001 certified Facility. 16.01 WARRANTY Standard limited warranty shall be 3 years. 250_P6 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

Pump Specifications 250 Series Submersible Sump / Effluent Pump 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

250-Series Dimensional Data 250_P2 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

250-Series Electrical Data MODEL HP VOLTAGE PHASE FULL LOAD AMPS LOCKED ROTOR AMPS THERMAL OVERLOAD TEMP STATOR WINDING CLASS CORD LENGTH FT DISCHARGE AUTOMATIC 250 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 251 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 253 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 257 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 NO MANUAL YES INTEGRAL FLOAT YES PIGGY BACK FLOAT YES INTEGRAL VERTICLE FLOAT 250-Series Cord Length Options* Model 10' 25'(-2) 35'(-3) 50'(-5) 250 Standard Optional Optional Optional 251 Standard Optional Optional Optional 253 Standard Optional Optional N/A 257 Standard Optional N/A N/A 10' cord length standard on all models. For optional lengths, add -2, -3 or -5 suffix to model number. Example: for model 250 with 35' cord. Order 250-3 WARNING: *Always use a replacement power cord assembly of the same length and type as originally installed on the Liberty product. Using a cord of improper gauge or length may lead to exceeding the electrical rating of the cord and could result in death, injury, fire or other significant failure. 250_P3 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

250-Series Technical Data IMPELLER VORTEX ENGINEERED POLYMER SOLIDS HANDLING SIZE ½ PAINT MAX LIQUID TEMP MAX STATOR TEMP THERMAL OVERLOAD POWER CORD TYPE MOTOR HOUSING / VOLUTE SHAFT HARDWARE ORINGS SEAL WEIGHT POWDER COAT 60 C 140 C CLASS B 130 C/ 266 F 105 C / 221 F SJTW (10ft & 25ft models) SJTOOW (35ft & 50ft models) CLASS 25 CAST IRON STAINLESS STAINLESS BUNA N ENGINEERED DOUBLE LIP SEAL WITH STAINLESS STEEL SPRINGS 23 LBS 250-Series Specifications 1.01 GENERAL: The contractor shall provide labor, material, equipment, and incidentals required to provide (QTY) centrifugal pumps as specified herein. The pump models covered in this specification are Series 250 single phase pumps. The pump furnished for this application shall be model as manufactured by Liberty pumps. 2.01 OPERATING CONDITIONS: Each submersible pump shall be rated at 1/3 hp, 115 volts, single phase, 60 Hz., 3450 RPM. The unit shall produce G.P.M. at feet of total dynamic head. The submersible pump shall be capable of handling effluent with 1/2 solid handling capability. The submersible pump shall have a shut-off head of 23 feet and a maximum flow of 44 GPM @ 5 feet of total dynamic head. The pump shall be controlled with: A piggy back style on/off float switch. An integrally wired on/off float switch. A Vertical Mechanical Float (VMF) type on/off switch. A NEMA 4X outdoor simplex control panel with three float switches and a high water alarm. A NEMA 1 indoor simplex control panel with three float switches and a high water alarm. A NEMA 4X outdoor simplex control panel with four float switches and a high water alarm. A NEMA 1 indoor simplex control panel with four float switches and a high water alarm. A NEMA 4X outdoor duplex control panel with three float switches and a high water alarm. 250_P4 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

A NEMA 1 indoor duplex control panel with three float switches and a high water alarm. A NEMA 4X outdoor duplex control panel with four float switches and a high water alarm. A NEMA 1 indoor duplex control panel with four float switches and a high water alarm. 3.01 CONSTRUCTION: Each centrifugal effluent pump shall be equal to the certified Series 250 SERIES pumps as manufactured by Liberty Pumps, Bergen NY. The castings shall be constructed of class 25 cast iron. The motor housing shall be oil filled to dissipate heat. Air filled motors shall not be considered equal since they do not properly dissipate heat from the motor. All mating parts shall be machined and sealed with a Buna-N o-ring. All fasteners exposed to the liquid shall be stainless steel. The motor shall be protected on the top side with sealed cord entry plate with molded pins to conduct electricity eliminating the ability of water to enter internally through the cord. The motor shall be protected on the lower side with an engineered double lip seal with stainless steel springs. The pump shall be furnished with stainless steel handle. 4.01 ELECTRICAL POWER CORD The submersible pump shall be supplied with 10, 25, 35, or 50 feet of multiconductor power cord. It shall be cord type SJTW, or SJTOOW capable of continued exposure to the pumped liquid. The power cord shall be sized for the rated full load amps of the pump in accordance with the National Electric Code. The power cable shall not enter the motor housing directly but will conduct electricity to the motor by means of a water tight compression fitting cord plate assembly, with molded pins to conduct electricity. This will eliminate the ability of water to enter internally through the cord, by means of a damaged or wicking cord. 5.01 MOTORS Single phase motors shall be oil filled, permanent split capacitor, class B insulated NEMA B design, rated for continuous duty. At maximum load the winding temperature shall not exceed 130 degrees C unsubmerged. Since air filled motors are not capable of dissipating heat they shall not be considered equal. The pump motor shall have an integral thermal overload switch in the windings for protecting the motor. The capacitor circuit shall be mounted internally in the pump. 6.01 BEARINGS AND SHAFT Upper and lower ball bearings shall be required. The bearings shall be a single ball / race type bearing. Both bearings shall be permanently lubricated by the oil, which fills the motor housing. The motor shaft shall be made of 300 or 400 series stainless steel and have a minimum diameter of.311". 7.01 SEALS The pump shall have an engineered double lip seal with stainless steel springs. The motor plate / housing interface shall be sealed with a Buna-N o-ring. 8.01 IMPELLER The impeller shall be engineered polymer, with pump out vanes on the back shroud to keep debris away from the seal area. It shall be threaded to the motor shaft. 9.01 CONTROLS All pumps can be supplied with a CSA and UL approved VMF type switch, an integrally wired wide angle tilt float switch, or piggy back type wide angle tilt float switches. The piggy back style switches are equipped with a plug that allows the pump to be operated manually without the removal of the pump in the event that a switch becomes inoperable. Manual pumps are operable by means of a pump control panel. 250_P5 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

10.01 PAINT The exterior of the casting shall be protected with Powder Coat paint. 11.01 SUPPORT The pump shall have cast iron support legs, enabling it to be a free standing unit. 12.01 SERVICEABILTY Components required for the repair of the pump shall be shipped within a period of 24 hours. 13.01 FACTORY ASSEMBLED TANK SYSTEMS WITH GUIDE RAIL AND QUICK DISCONNECT DISCHARGE Guide factory mounted rail system with pump suspended by means of bolt on quick disconnect which is sealed by means of nitrile grommets or o-rings. Discharge piping shall be schedule 80 PVC and furnished with a PVC shut-off ball valve. The Tank shall be wound fiberglass or roto-molded plastic. An inlet hub shall be provided with the fiberglass systems. Stainless steel Guide Rail Zinc plated steel Guide Rail "diameter of basin size "height of basin size "distance from top of tank to discharge pipe outlet Fiberglass cover Structural foam polymer cover Steel cover Simplex System with Outdoor panel and alarm Duplex System with Outdoor panel and alarm Separate Outdoor Alarm Remote Outdoor Alarm 14.01 TESTING The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity, moisture content and insulation defects. The motor and volute housing shall be pressurized, and an air leak decay test is performed to ensure integrity of the motor housing. The pump shall be run, voltage current monitored, and the tester checks for noise or other malfunction. 15.01 QUALITY CONTROL The pump shall be manufactured in an ISO 9001 certified Facility. 16.01 WARRANTY Standard limited warranty shall be 3 years. 250_P6 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

Pump Specifications 250 Series Submersible Sump / Effluent Pump 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

250-Series Dimensional Data 250_P2 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

250-Series Electrical Data MODEL HP VOLTAGE PHASE FULL LOAD AMPS LOCKED ROTOR AMPS THERMAL OVERLOAD TEMP STATOR WINDING CLASS CORD LENGTH FT DISCHARGE AUTOMATIC 250 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 251 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 253 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 257 1/3 115 1 5.2 8 105 C / 221 F B 10 1 1/2 NO MANUAL YES INTEGRAL FLOAT YES PIGGY BACK FLOAT YES INTEGRAL VERTICLE FLOAT 250-Series Cord Length Options* Model 10' 25'(-2) 35'(-3) 50'(-5) 250 Standard Optional Optional Optional 251 Standard Optional Optional Optional 253 Standard Optional Optional N/A 257 Standard Optional N/A N/A 10' cord length standard on all models. For optional lengths, add -2, -3 or -5 suffix to model number. Example: for model 250 with 35' cord. Order 250-3 WARNING: *Always use a replacement power cord assembly of the same length and type as originally installed on the Liberty product. Using a cord of improper gauge or length may lead to exceeding the electrical rating of the cord and could result in death, injury, fire or other significant failure. 250_P3 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

250-Series Technical Data IMPELLER VORTEX ENGINEERED POLYMER SOLIDS HANDLING SIZE ½ PAINT MAX LIQUID TEMP MAX STATOR TEMP THERMAL OVERLOAD POWER CORD TYPE MOTOR HOUSING / VOLUTE SHAFT HARDWARE ORINGS SEAL WEIGHT POWDER COAT 60 C 140 C CLASS B 130 C/ 266 F 105 C / 221 F SJTW (10ft & 25ft models) SJTOOW (35ft & 50ft models) CLASS 25 CAST IRON STAINLESS STAINLESS BUNA N ENGINEERED DOUBLE LIP SEAL WITH STAINLESS STEEL SPRINGS 23 LBS 250-Series Specifications 1.01 GENERAL: The contractor shall provide labor, material, equipment, and incidentals required to provide (QTY) centrifugal pumps as specified herein. The pump models covered in this specification are Series 250 single phase pumps. The pump furnished for this application shall be model as manufactured by Liberty pumps. 2.01 OPERATING CONDITIONS: Each submersible pump shall be rated at 1/3 hp, 115 volts, single phase, 60 Hz., 3450 RPM. The unit shall produce G.P.M. at feet of total dynamic head. The submersible pump shall be capable of handling effluent with 1/2 solid handling capability. The submersible pump shall have a shut-off head of 23 feet and a maximum flow of 44 GPM @ 5 feet of total dynamic head. The pump shall be controlled with: A piggy back style on/off float switch. An integrally wired on/off float switch. A Vertical Mechanical Float (VMF) type on/off switch. A NEMA 4X outdoor simplex control panel with three float switches and a high water alarm. A NEMA 1 indoor simplex control panel with three float switches and a high water alarm. A NEMA 4X outdoor simplex control panel with four float switches and a high water alarm. A NEMA 1 indoor simplex control panel with four float switches and a high water alarm. A NEMA 4X outdoor duplex control panel with three float switches and a high water alarm. 250_P4 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

A NEMA 1 indoor duplex control panel with three float switches and a high water alarm. A NEMA 4X outdoor duplex control panel with four float switches and a high water alarm. A NEMA 1 indoor duplex control panel with four float switches and a high water alarm. 3.01 CONSTRUCTION: Each centrifugal effluent pump shall be equal to the certified Series 250 SERIES pumps as manufactured by Liberty Pumps, Bergen NY. The castings shall be constructed of class 25 cast iron. The motor housing shall be oil filled to dissipate heat. Air filled motors shall not be considered equal since they do not properly dissipate heat from the motor. All mating parts shall be machined and sealed with a Buna-N o-ring. All fasteners exposed to the liquid shall be stainless steel. The motor shall be protected on the top side with sealed cord entry plate with molded pins to conduct electricity eliminating the ability of water to enter internally through the cord. The motor shall be protected on the lower side with an engineered double lip seal with stainless steel springs. The pump shall be furnished with stainless steel handle. 4.01 ELECTRICAL POWER CORD The submersible pump shall be supplied with 10, 25, 35, or 50 feet of multiconductor power cord. It shall be cord type SJTW, or SJTOOW capable of continued exposure to the pumped liquid. The power cord shall be sized for the rated full load amps of the pump in accordance with the National Electric Code. The power cable shall not enter the motor housing directly but will conduct electricity to the motor by means of a water tight compression fitting cord plate assembly, with molded pins to conduct electricity. This will eliminate the ability of water to enter internally through the cord, by means of a damaged or wicking cord. 5.01 MOTORS Single phase motors shall be oil filled, permanent split capacitor, class B insulated NEMA B design, rated for continuous duty. At maximum load the winding temperature shall not exceed 130 degrees C unsubmerged. Since air filled motors are not capable of dissipating heat they shall not be considered equal. The pump motor shall have an integral thermal overload switch in the windings for protecting the motor. The capacitor circuit shall be mounted internally in the pump. 6.01 BEARINGS AND SHAFT Upper and lower ball bearings shall be required. The bearings shall be a single ball / race type bearing. Both bearings shall be permanently lubricated by the oil, which fills the motor housing. The motor shaft shall be made of 300 or 400 series stainless steel and have a minimum diameter of.311". 7.01 SEALS The pump shall have an engineered double lip seal with stainless steel springs. The motor plate / housing interface shall be sealed with a Buna-N o-ring. 8.01 IMPELLER The impeller shall be engineered polymer, with pump out vanes on the back shroud to keep debris away from the seal area. It shall be threaded to the motor shaft. 9.01 CONTROLS All pumps can be supplied with a CSA and UL approved VMF type switch, an integrally wired wide angle tilt float switch, or piggy back type wide angle tilt float switches. The piggy back style switches are equipped with a plug that allows the pump to be operated manually without the removal of the pump in the event that a switch becomes inoperable. Manual pumps are operable by means of a pump control panel. 250_P5 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

10.01 PAINT The exterior of the casting shall be protected with Powder Coat paint. 11.01 SUPPORT The pump shall have cast iron support legs, enabling it to be a free standing unit. 12.01 SERVICEABILTY Components required for the repair of the pump shall be shipped within a period of 24 hours. 13.01 FACTORY ASSEMBLED TANK SYSTEMS WITH GUIDE RAIL AND QUICK DISCONNECT DISCHARGE Guide factory mounted rail system with pump suspended by means of bolt on quick disconnect which is sealed by means of nitrile grommets or o-rings. Discharge piping shall be schedule 80 PVC and furnished with a PVC shut-off ball valve. The Tank shall be wound fiberglass or roto-molded plastic. An inlet hub shall be provided with the fiberglass systems. Stainless steel Guide Rail Zinc plated steel Guide Rail "diameter of basin size "height of basin size "distance from top of tank to discharge pipe outlet Fiberglass cover Structural foam polymer cover Steel cover Simplex System with Outdoor panel and alarm Duplex System with Outdoor panel and alarm Separate Outdoor Alarm Remote Outdoor Alarm 14.01 TESTING The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity, moisture content and insulation defects. The motor and volute housing shall be pressurized, and an air leak decay test is performed to ensure integrity of the motor housing. The pump shall be run, voltage current monitored, and the tester checks for noise or other malfunction. 15.01 QUALITY CONTROL The pump shall be manufactured in an ISO 9001 certified Facility. 16.01 WARRANTY Standard limited warranty shall be 3 years. 250_P6 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.