INSTALLATION & OPERATION MANUAL

Similar documents
OWNER S MANUAL. INSTALLATION AND OPERATION INSTRUCTIONS FOR 12 VOLT BATTERY BACK-UP SYSTEM Models: 92900, 92910

Installation Operation Parts

STEP-BY-STEP INSTALLATION GUIDE

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

MODEL H INSTALLATION INSTRUCTIONS

SUBMERSIBLE SUMP PUMPS

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

SUBMERSIBLE SUMP PUMPS

Matala. VersiFlow Series. Instruction and Maintenance Manual

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

ESE Series Cast Iron Sewage Pumps

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

GeyserMax-Flow Series

Model: SE-4020-CA Automatic Battery Charger

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer

Owner s Manual Drill and Light Weight Portable Utility Pumps

SUBMERSIBLE PUMP HSE RANGE

PRE-PLUMBED SEWAGE SYSTEM

StormPro BA Series Sump Pump

SUBMERSIBLE PUMP HSE RANGE

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

SUNC3000 / Item #40885

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Installation & Operating Manual

StormPro BCV400 Sewage Ejector Pump

POWER TO GET THE JOB DONE

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

PSJ-2212, PSJ-3612, PSJ-4424

Submersible Effluent Pump

INTELLIGENT BATTERY CHARGER/MAINTAINER

Battery. Charger Model: Save Important Safety Instructions

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

M-3025CB-AV Fuel Pump

Cruising Charger Series OWNER S MANUAL

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

QSSE, QSSEX INDUSTRIAL Battery Chargers

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

SUPER PUMP OUT SYSTEM

10 AMP ON BOARD BATTERY CHARGER

MODEL 585 BATTERY BACKUP PEDESTAL SUMP PUMP PREINSTALLATION CHECKLIST SEE BELOW FOR LIST OF WARNINGS CAUTION SEE BELOW FOR LIST OF CAUTIONS

IMPORTANT SAFETY INSTRUCTIONS

QPET, QPETXU Battery Chargers

Operating Manual Includes Pumps: PG-9000 Part #R809606

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Installation and Operating Instructions (for chargers shown below)

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

SP6. Automatic Battery Charger. Model

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

FULLY AUTOMATIC SCR BATTERY CHARGER

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

507/53 507/98 CAUTION. NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority

AUTOMATIC BATTERY CHARGER AUTOMATISCHES BATTERIELADEGERÄT CHARGEUR DE BATTERIE AUTOMATIQUE AUTOMATISCHE ACCULADER 12A RMS (8A DC) MCH12A

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

Models: SP3, SPSS3 Automatic Battery Charger

PREINSTALLATION CHECKLIST

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

INSTALLATION INSTRUCTIONS

SUBMERSIBLE SWIMMING POOL DRAINER

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

MODEL P INSTALLATION INSTRUCTIONS

S2n1 PREASSEMBLED SUMP PUMP SYSTEM

Installation and Operating Instructions (for chargers shown below)

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

OWNER S MANUAL POWER INVERTER

Powerful & Intelligent Submersible Pumps

LESTRONIC II BATTERY CHARGER MODEL 07210

SUBMERSIBLE WATER PUMPS

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

Power Inverter 400 MW Owner s Manual

SUBMERSIBLE PUMP 400 WATTS, WITH FLOAT Model 45019

GARDEN HOSE UTILITY PUMP

Combination Primary and Backup Sump Pump System

NIGHT-LITE PRO II. Electrical System Troubleshooting Guide and Procedures

1/2 HP SUMP PUMP OWNER'S MANUAL

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

Sump / Effluent Pump

12V/25A BATTERY CHARGER MAINTAINER / JUMPSTARTER

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

innovations in battery charging

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

Submersible Sewage Ejector Pump

Safety, Installation And Operating Instructions For The Following Battery Charger Models: i2412, i3612, i4809, i2425, i3625, and i4818

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

MP V 8A Electronic Smart Charger. Instruction and Information Manual

OWNERS MANUAL BATTERY CHARGER MODEL 19300

MODEL 6017 OPERATOR'S MANUAL

CRAFTSMAN+ PEDESTAL SUMP PUMP OWNER'S MANUAL. Model No Operation Installation Service

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

User s Manual. Automatic Switch-Mode Battery Charger

Transcription:

INSTALLATION & OPERATION MANUAL PRE-ASSEMBLED PRIMARY & BATTERY BACK-UP SUMP PUMP SYSTEM 5030CVSPBUSS, 5033CVSPBUSS www.aymcdonald.com A.Y. McDonald BBU Manual Revised 8-13 3210-479 Rev. A 12

This pump has been manufactured with your needs in mind. Properly installed in the right application, your new A.Y. McDonald pump will give you years of carefree performance. Notes: Important Safety Information: Carefully read and understand all of the Warnings and installation instructions in this manual. Failure to follow these instructions could lead to serious bodily injury and/or property damage. Retain these instructions for future reference. RISK OF ELECTRICAL SHOCK. Always disconnect the power source before attempting to install, service or perform maintenance on the pump. Failure to do so may result in fatal electrical shock. RISK OF ELECTRICAL SHOCK. This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electrical shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. RISK OF ELECTRICAL SHOCK. Do not plug in or unplug the AC transformer while standing on a wet floor. If basement floor is wet, disconnect the power before walking on the floor. Water and electricity can be dangerous if certain precautions are not adhered to. This pump is designed to operate perfectly safe in a water environment; however, improper use and installation can result in personal harm from electrical shock. Please pay attention to the following warnings. Never touch any electrical device, including this pump, when it is touching water, in water, or even in a moist environment. Always unplug (disconnect the electricity) when working on or installing the unit. Keep all electrical connections away from wet and moist environments. Wet connections can cause electrical shock resulting in personal injury. Do not use this unit to pump chemicals, flammable liquids, sewage or corrosive liquids. You could injure yourself and the pump will fail. Pumping these types of liquids voids the warranty. A.Y. McDonald and other pump companies manufacture pumps for these types of liquids. Make sure you purchase a pump designed for your specific needs. This pump will handle fluids with the same characteristics as water. Battery acid is corrosive. Do not spill on skin, clothing, or parts of this system. Wear gloves and eye protection when handling the battery. 2 11

Notes: Always use a grounded outlet to attach the plug. A three-prong mating type receptacle is needed for safe use. This should be in accordance with the National Electric Code and any additional codes or laws required by your local government. It is strongly recommended to use a ground fault interrupt device on any electrical appliance, including this pump, when used in a wet or moist environment. This GFCI (ground fault circuit interrupter) should be listed by Underwriters Laboratories (UL). This is required by many local codes and enforcement agencies. It is strongly recommended by A.Y. McDonald as it provides a much safer installation and will greatly reduce possible injury from electrical shock. EXTENSION CORDS: For best performance, it is recommended to connect the AC transformer power cord directly to a grounded GFCI outlet. The use of extension cords is NOT recommended. Do not use the power cord or discharge hose to carry or handle the pump. Doing so may cause damage to the power cord or discharge hose. Use the carrying handle supplied with the pump. EXTENSION CORDS: For best performance, it is recommended to connect the power cord directly to the grounded GFCI outlet. If the use of an extension cord is, always use a grounded waterproof type cord. Never use longer than a 25-ft. cord that is lighter than 14/3 gauge. A qualified electrician must perform all wiring. Your pump has thermal over-load protection built in. It is not recommended for pumping liquids over 120 F. The thermal overload protector will automatically shut down the pump in an overheat situation. It will then reset itself once the pump cools down. The pump will then work again. This overload is designed as a safety device and it will fail after repeated use. Normal operation is for fluids between 32 F & 120 F. DO NOT RUN THE PUMPS DRY. The pumps depends on water for cooling and lubrication. Operating the pumps without water may cause the motor to overheat or cause damage to parts of the pump. It may also shorten the life of your pumps. 10 3

BATTERY SELECTION This system is designed to work with 12 volt, lead-acid deep cycle marine / RV batteries. Either a flooded cell (serviceable or maintenance free) or sealed AGM battery are acceptable. Choose a battery with a minimum 90 amp-hour rating and a 175 minute reserve capacity or larger. Avoid using automobile batteries as these types of batteries are not intended to be charged/discharged for extended periods of time. The battery case will accommodate size 24 or 27 batteries. 1 PARTS LIST 5000 5030, 5033 11 3 During prolonged periods of power failure or in an emergency, your automobile battery may be used. Make sure to replace the deep cycle battery as soon as possible as the automobile battery will be quickly ruined by the continuous charge/discharge cycles. GENERAL INFORMATION 3 2 2 1 This battery back-up system is not intended to replace your primary sump pump. It is intended to provide temporary back-up during power failures or malfunctions with the primary pump. 9 13 9 CARBON MONOXIDE (CO) DETECTORS All back-up pump systems that use lead acid batteries, regardless of brand, give off gaseous by-products when the battery is charging. Some of these by-products can cause a carbon monoxide (CO) detector to give a false alarm. When installing this system, position the battery as far away from the CO detector as possible. DO NOT move or remove CO detectors from their original location. Always follow the instructions that accompany your CO detector. If your CO detector alarm sounds, take the following actions. 4 5 6 14 12 5 4 6 10 1. Take immediate action for personal safety as outlined in the CO detector manual. 2. Contact the appropriate utility agency to determine if the CO is coming from your furnace, water heater or other appliance that uses natural gas 7 8 7 If it s determined that a charging battery is causing the CO detector to activate, contact the manufacturer for recommendations on how to alleviate the problem. A qualified electrician must perform all wiring. INSTALLATION RISK OF ELECTRICAL SHOCK. Always disconnect the power source before attempting to install, service or perform maintenance on the pump. Failure to do so may result in fatal electrical shock. This pump kit is completely assembled. To install, simply place the pump assembly in the bottom of your basin and connect to your new or existing discharge pipe. The pump should be placed on a solid foundation. Do not place the pump directly on the ground or sandy or rocky surfaces. Sand and small stones may clog or cause damage to your pump. Make sure the float switches will operate freely without coming in contact with the sides of the sump basin. Contact with the side of the sump basin may cause the switch to malfunction. See figure. 10 Ref Description 1 Power Cord 2 Handle 3 Oil Fill Plug with O-ring 4 Shaft Seal 5 Impeller 6 Gasket 7 Volute/Base 8 Intake Screen 9 Float Switch 10 Vertical Float Switch Bracket 11 Battery Box (Complete Unit) 12 Control Panel 13 AC Power Cord 14 Battery Terminals (+ & - ) 15 Check Valve 15 PARTS FOR MODEL# 5030CVSP 5000PVSPBU 5033CVSP Please call your Professional Plumber for price and availability 8 4 9

NOTICE: Height and/or piping restriction will reduce the pump output performance. See the performance chart below to insure you have the proper pump for your application. Whenever possible use the same size or larger pipe as the pump discharge for optimum performance. Reducing the pipe size will not harm your pump; it will just reduce the output. PERFORMANCES Model # Output in gallons per minute at listed discharge height above pumping level 0 5 10 15 20 25 5000PVSPBU 23 22 18 13 8-5030CVSP 46 36 30 25 12 1 5033CVSP 60 56 50 35 15 6 *Performance ratings are based on using a 27M, 12 volt deep cycle marine battery with a 100 Ah rating Motor SPECIFICATIONS 12 VOLT DC PUMP - MODEL 5000PVSPBU Amps 12 Battery Requirements Low Voltage Shut off Solids Handling 1/8 12 volt DC 12 Volt Deep Cycle Marine 10 Volts Discharge Size 1-1/4 or 1-1/2 Battery Charger Liquid Temperature Range 2 amp 32-120 F (0-49 C) WIRING & ELECTRICAL CONNECTIONS 1. If, attach the provided battery terminals to the battery. (Many deep cycle marine batteries come with a threaded post terminal built in.) NOTE: The provided battery terminals are labeled (+) positive and (-) negative. Make sure the terminals are connected to the proper terminal on the battery. Place the battery in the battery box. 2. Connect the battery lead wires from the control panel to the corresponding terminals on the battery. Connect the red (+) positive lead to the positive battery terminal and tighten the wing nut. Connect the black (-) negative lead to the negative battery terminal and tighten the wing nut. Secure the battery box cover to the lower case. 3. Next connect the pump power cord, the float switch and the AC adapter to the corresponding terminals on the control panel. Make sure they are fully seated in the terminals. 4. Plug the AC adapter into the wall outlet and turn the power back on. 5. If your battery is fully charged you will notice a green light on the AC adapter. If the battery is not fully charged a red light will indicate that the battery is charging. Once fully charged, the light will change to green. SPECIFICATIONS 120 VOLT PRIMARY PUMP Motor 120 VOLT AC Liquid Temperature Range 32-120 F (0-49 C) Power Supply Requirements 120V, 60 Hz (15 amp) Motor Continuous Duty, Capacitor Start, Thermally Protected Model # 5030CVSP 5033CVSP HP 3/10 1/3 Amps 4.1 5.9 6. Once all connections are made, press the MUTE/ALARM button on the control panel until the ALARM light illuminates. This indicates that the alarm will sound once the pump is activated. To mute the alarm, press the MUTE/ALARM button on the control panel until the ALARM light turns off. 7. Test the float switch and pump by lifting and holding the float. The alarm will sound and the PUMP ON light on the control panel will illuminate. The pump should start after lifting the float. If it does not run, check your connections and retry. Solids Handling 3/8 1/2 Discharge Size 1 1 / 2 1 1 / 2 8 5

TESTING YOUR INSTALLATION 1. Once your installation and wiring connections are complete, unplug or disconnect the power to the primary pump. 2. Fill the basin using buckets or a hose. Observe the float switches to make sure they are positioned properly when the basin is filling. Fill the basin until the back-up float activates the alarm. 3. Make any adjustments to the float(s) and/or pumps at this time. OPERATION 1. When the power fails or when there is a problem with the primary pump, the back-up pump will automatically start. The back-up pump will operate for many hours intermittently. During prolonged periods of power outage the pump may stop pumping when the battery voltage drops below 10 volts. When this happens the alarm will sound signaling that the voltage is too low to operate the pump. 2. This unit is equipped with a 2 amp charger. It will charge a discharged battery at a rate of 2 Ah (Amp hours). Once the battery reaches a full charge, the charger will gradually reduce the charge rate. It will also maintain a charged battery by periodically checking the voltage of the battery. 3. The charger is equipped with over charge protection. It will not let the battery become over charged. 120 VOLT AC PRIMARY PUMP TROUBLESHOOTING PROBLEM POSSIBLE CAUSES HOW TO CORRECT If the pump does not start or run The pump starts and stops too often Pump is not plugged in, switch or breaker is off Check for blown fuses or tripped circuit breakers or tripped GFCI outlets Float switch is defective Motor thermal protector tripped Float switch is stuck or obstructed Backflow of water from discharge hose/pipe Float switch is defective Clogged intake screen Clogged discharge hose/pipe Plug pump in or turn on switch/ breaker Replace fuse, reset breaker, reset GFCI outlet Check and replace if Allow pump to cool. Pump will reset Remove obstruction or position pump so it will not become stuck Install or replace check valve Replace float switch Clean or replace screen Remove clog 12 VOLT DC BACK-UP PUMP TROUBLESHOOTING Frozen discharge hose/pipe Pump is air locked Allow hose/pipe to thaw Clean out airlock hole with a paper clip or pipe cleaner PROBLEM POSSIBLE CAUSES HOW TO CORRECT Pump won t run. Pump hums but won t run Loose, corroded or reversed wire connections Discharged battery Defective battery Blown fuse Float switch is stuck Tighten, clean or reconnect if Charge battery Replace battery Replace with 20 amp fuse Position float so it moves freely If the pump runs but moves little or no water Low line voltage Check valve is stuck in the closed position Check valve is installed backwards Worn, damaged or clogged pump parts Check wire size and increase if Inspect, repair or replace if Make sure check valve is installed in the correct direction of flow Inspect for wear, damage or clog and clean or replace if Pump cycles too often Battery is discharged below 10 volts Float switch positioned improperly Defective or missing check valve Fully charge battery Reposition float switch Install or replace check valve Pump does not shut off Discharge head exceeds pump capacity Float switch is obstructed or stuck Defective Float Switch If pumping height is over 25, the pump will not move water. See performance chart Remove obstruction Replace switch Low or discharged battery Fully charge battery Pump runs but moves little or no water Obstruction in pipe Discharge pipe height/length exceeds the capacity of the pump Defective check valve Clear obstruction Check performance section for capacity of this pump Replace Check Valve if 6 7