Operation Manual for Mag650 Three-Axis Magnetic Field Sensor

Similar documents
Operation Manual for. CU2 Helmholtz Coil System Closed-Loop Module

Operation Manual for. HC16 Three-Axis Helmholtz Coil

HC2 Three-Axis Helmholtz Coil

CU2 Closed Loop Module

PSU1 Power Supply Unit

HC1, HC2 and HC9. Helmholtz Coil Systems

Mag-03. Three-Axis Magnetic Field Sensors. Mag-03. World leaders in high precision magnetic field measurements

Switching DC Power Supply

PT100 Temperature Sensor User Manual

Model 1693, 1694 Switching DC Power Supply

Model UT601: OPERATING MANUAL

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Time Electronics DC Voltage Calibrator. Technical Manual

Commissioning Manual AC Servo Actuator LynxDrive SIEMENS SIMODRIVE

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Pan and Tilt Head CDD2416-T

Rental Industry Safety Tester Safe Check 5s

Excellence in Level Measurement

IEC 62133:2012 (2nd Edition) Understanding IEC Safety Requirements for Rechargeable Cells & Batteries used in Portable Devices

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Allen-Bradley 1397 Pulse Encoder Interface Card

Wind Power Inverter WINDY BOY 5000A/6000A

POWER REGULATOR LD -40PSU

Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No

World Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual

High Frequency SineWave Guardian TM

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

BM kv Digital Insulation Tester USER MANUAL

Installation, Operation and Maintenance Instructions

PDS V Pendant Ball Loudspeaker

323/324/325 Clamp Meter

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Atlas ESR and ESR + Equivalent Series Resistance and Capacitance Meter. Model ESR60/ESR70. Designed and manufactured with pride in the UK.

DD6 ULTRA-COMPACT DIFFERENTIAL DISPERSION SYSTEM

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Installation and Operating Instructions. Solar System Controller ISC3020

EEMB CO., LTD. Lithium Manganese Dioxide Battery Specification. Button Type. Prepared Checked Approved. Signature Checked Approved

Model UT602/603: OPERATING MANUAL

Filterpack FR-BFP2-(H)0.4K to (H)15K

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

362 Clamp Meter. Users Manual

User Manual Stealth s Power Tilt

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Operator Instructions for Tension Links

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

BEFORE USING THE PRODUCT

362 Clamp Meter. Users Manual

365 Detachable Jaw True-rms Clamp Meter

302+/303 Clamp Meter. Users Manual

Installation, Operation and Maintenance Instructions

SPEAKER SYSTEMS F-2000B F-2000BT F-2000BTWP F-2000W F-2000WT F-2000WTWP OPERATING INSTRUCTIONS

VECTOR INVERTER -INSTRUCTION MANUAL- ADDITIONAL OPEN COLLECTOR OUTPUT / PLG PULSE DIVISION OUTPUT FR-V5AY

Operators Guide: RoboSign Stop/Go Traffic Control System

Magnetism and Electricity ASSIGNMENT EDULABZ. the mere presence of magnet, is called...

SPEAKER SYSTEMS F-1000B F-1000BT F-1000BTWP F-1000W F-1000WT F-1000WTWP OPERATING INSTRUCTIONS

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

EVS RP6020. Instruction Manual

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

Operating Instructions. bluesmart Active

D Issue J. Instruction Manual. Active Inverted Magnetron Gauge. Original instructions

B-RAD Select USER MANUAL TABLE OF CONTENTS

Displacement Sensor. Model 8739, 8740, 8741

Operators Guide: RoboSign Stop/Go Traffic Control System

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

Technical Information Manual

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Atlas ESR. User Guide. Capacitance and Equivalent Series Resistance Meter. Model ESR60 (Enhanced)

BUTTON CELL CR2450S BRIEF SPECIFICATION

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

COIN CELL CR2477 BRIEF SPECIFICATION

PY-11 Voltage & Continuity Tester

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

Data Sheet P992 Low Range Differential Pressure Sensor

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

B297SB-01-1K40. AnyWireASLINK System Product Guide. ASLINKSENSOR [Photo Interrupter type] -B297SB011K40 1/7- [Function] [Notes on Safety]

Lamp House with 2.5 kw lamp

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

373 Clamp Meter. Users Manual

Installation and Operating Instructions. Solar System Controller ISC3030

Differential Pressure Transmitter

Model 134A24 Tourmaline ICP pressure bar, 1000 psi, 5 mv/psi, 0.2 microsecond rise. Installation and Operating Manual

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

Below, you can see the warning symbols used throughout the manual and their meaning.

80 Litre Suction Oil Drainer With Inspection Chamber

Permanent Magnet DC Motor

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

INTRODUCTION WARNING SIGNS AND THEIR MEANINGS

Model 1900, 1901, 1902 Switching DC Power Supply

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

MANUAL NO E1.2 Published in Dec.2004 Revised in Aug LF Series Linear Variable Differential Transformer INSTRUCTION MANUAL

HIGH VOLTAGE PROXIMITY DETECTOR

3.25 Ton Heavy Duty Floor Jack

Transcription:

Operation Manual for Mag650 Three-Axis Magnetic Field Sensor

Table of Contents 1. About this Manual 3 1.1. Symbols Glossary 3 2. Safe Use 3 3. Introduction 4 4. Overview 4 4.1. Vector Measurements and Conventions 5 5. Installation 5 5.1. Unpacking 5 5.2. Orientation 5 5.3. Mounting 6 6. Connection Recommendations 6 7. Pre-Installation Tests 6 8. Operating Instructions 7 9. Troubleshooting 7 10. Storage & Transport 8 11. Environmental Precautions 8 12. End of Life Disposal 9 Page 2 of 10

1. About this Manual This manual describes the installation, operation and maintenance of the Mag650 three-axis magnetic field sensor from Bartington Instruments. It should be read in conjunction with product brochure DS3403 which can be found on the product page on the Bartington Instruments website. 1.1. Symbols Glossary The following symbols used within this manual call your attention to specific types of information: WARNING: Indicates a situation in which serious bodily injury or death could result if the warning is ignored. Caution: Indicates a situation in which bodily injury or damage to your instrument, or both, could result if the caution is ignored. Identifies a risk of damage by electrostatic discharge. Identifies items that must be disposed of safely to prevent unnecessary damage to the environment. Note: A note provides useful supporting information and sometimes suggests how to make better use of your purchase. 2. Safe Use WARNING: This product is not qualified for use in explosive atmospheres or life support systems. Consult Bartington Instruments for advice. Page 3 of 10

3. Introduction Figure 1.Mag 650U. The Mag650 is an unpackaged, three-axis, low power sensor intended for customer system integration. It is designed to be installed in a cylindrical enclosure. Technical specifications for the Mag650 are provided in the product brochure. 4. Overview The Mag650 is a sensor consisting of a cluster of three feedback stabilised, fluxgate sensors arranged along X, Y and Z axes. Each axis provides a highly linear magnetic response with low hysteresis, and low crosstalk between axes. These characteristics, combined with the compact design and very low power consumption, make this sensor ideally suited for integration in a multi sensor surveillance system. Internal regulation of the power supply ensures the Mag650 is suitable for battery powered operation, over both long and short cables (subject to the minimum supply voltage specified in the product brochure). Page 4 of 10

4.1. Vector Measurements and Conventions Each sensor produces three independent analogue output voltages in response to the magnitude and direction of the orthogonal components of a magnetic field. A right-hand coordinate system is adopted. In this system the X, Y and Z axis correspond to the thumb, first and second finger respectively of the right hand. East +Y 1st Finger North +X Thumb Down +Z 2nd Finger Figure 2. Illustration of the Right Hand Rule The centres of the three vector sensors are superimposed. Refer to outline drawing DR3403 for the orientation of each sensor and the centre of the sensing elements. The point of each vector arrow in DR3403 indicates the positive direction of each axis. 5. Installation The Mag650 is intended for integration into the customer s own system. Bartington Instruments cannot advise on the operation of third-party systems. 5.1. Unpacking Caution: Safe handling precautions must be observed. 5.2. Orientation Note: The direction of the geomagnetic field will vary with geographical location. It is generally vertical at the poles, becoming horizontal at the equator. Page 5 of 10

5.3. Mounting The Mag650 sensor assembly should be mounted in a stress-free manner using the three mounting holes on the PCB. Dimensions and locations of the holes are shown in outline drawing DR3403. Note: Use nylon or plastic screws for mounting. 6. Connection Recommendations The connection configuration and function information can be found on outline drawing DR3403. The Mag650 provides differential output lines for analogue signal transmission. The advantages of this differential arrangement are very high common-mode noise rejection. Each of the two anti-phase output lines has low output impedance at the signal source, damping the lines and preventing ringing. The Mag650 must be terminated with a differential amplifier having a circa 50kΩ input impedance, due to cable inductance and capacitance considerations. This arrangement will provide some damping to high frequencies but will attenuate the signals above the frequency range of the sensor. Note: The pair loop resistance should not exceed 0.1Ω per metre. The pair loop inductance should not exceed 0.5 micro-henry per metre. The capacitance between should not exceed 52pF per metre. The capacitance between conductors and shield should not exceed 120pF per metre. 7. Pre-Installation Tests Prior to the installation into the customer s system, the Mag650 must be fully tested to ensure correct function as follows: Caution: Ensure the polarity is correct. Incorrect polarity is likely to damage the sensor irreparably. Note: Use a current-limited power supply. Check the power supply output voltage using a voltmeter. Refer to the product brochure for the required values. Page 6 of 10

Connect the sensor to the power supply. Switch on the power supply and wait until the sensor has stabilised. Refer to the product brochure for warm-up times. Confirm no magnetic objects are moving in the vicinity. For each of the three (X, Y and Z) axes in turn: a. Connect a voltmeter to the axis sensor outputs. b. Whilst monitoring the voltmeter readings, align the sensor with the terrestrial field until the maximum voltage value is determined. c. Confirm the measured readings approach the local geomagnetic field value. Note: Geomagnetic field values can be provided by your local magnetic observatory. A margin of error due to local disturbance should be taken into account. 8. Operating Instructions Switch on the power supply to the Mag650. Allow the system to warm up after switching on. Refer to the product brochure for warm-up times. The Mag650 is designed to have an extremely low magnetic hysteresis. However, your sensor should not be subjected to magnetic fields greater than their stated measuring range for extended periods as this could alter the DC offset. If this occurs, the offset will exhibit drift as it returns to its original offset specification. Caution: Subjecting the Mag650 to fields in excess of 2 x the nominal range may cause inaccuracy in future measurements. Degaussing the sensor can reverse such an effect. 9. Troubleshooting Your sensor is unlikely to suffer any defects in normal use: no internal components are serviceable. The most likely causes of failure, and their solutions, are detailed in the following table. In the event of any apparent malfunction beyond those described in the table below, please email service@bartington.com, or telephone the Bartington Instruments service team on +44 (0)1993 706565. Page 7 of 10

Cause Solution No operation Damaged sensor Check the power supply. If this is operating correctly then contact Bartington Instruments. If any physical damage is apparent to the sensor then it may need to be replaced. For information about disposal of a damaged unit, refer to End of Life Disposal. 10. Storage & Transport Your sensor is a precision electronic instrument and should be treated as such. Note: Avoid exposing this instrument to shocks or continuous vibration. Note: The sensor should be stored and transported in the original shipment packaging, or that of similar protective standard. Note: Store only within the temperature range specified in the product brochure. Caution: Do not expose this instrument to strong magnetic fields while being stored. Caution: Take particular care when cleaning around electrical connections. Bent or damaged pins may cause the Mag650 to malfunction. 11. Environmental Precautions Refer to the product brochure for maximum environmental, electrical and mechanical ratings. Caution: Exceeding the maximum environmental ratings may cause irreparable damage to the probe and electronics board. Caution: This unpackaged product is susceptible to damage by electrostatic discharge. Page 8 of 10

12. End of Life Disposal This product (electrical and electronic equipment) should not be placed in municipal waste. Check local regulations for disposal of electronic products. Page 9 of 10

T: +44 (0)1993 706565 F: +44 (0)1993 774813 E: sales@bartington.com Bartington Instruments Limited 5 Thorney Leys Business Park, Witney, Oxford, OX28 4GE, England. www.bartington.com The copyright of this document is the property of Bartington Instruments Ltd. Bartington is a registered trade mark of Bartington Instruments Limited in the following countries: United Kingdom, Australia, Brazil, Canada, China, European Union, India, Japan, Norway and the United States of America.