MB Series AC Centrifugal Blowers

Similar documents

US U. Speed Control Motors. Features. Safety Standards and CE Marking M o t o r. Product Number Code

Reversible Motors. Standard AC Motors. Constant Speed Motors. Standard AC Motors C-75. Reversible Motors

Electromagnetic. Brake Motors. Constant Speed Motors. Standard AC Motors A-109. Standard AC Motors Introduction. Brake Motors

Induction Motors. Standard AC Motors. Constant Speed Motors. Standard AC Motors C-19. Induction Motors

RoHS-Compliant. Watertight, Dust-Resistant Motors FPW Series

COMPONENT Type SS21-UL Type

Torque Motors 3 W, 6 W, 10 W, 20 W

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

AC centrifugal fan. forward-curved, single-intake with housing (flange)

US Series Single-Phase 110/115 VAC Single-Phase 220/230 VAC

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

AC centrifugal fan. forward-curved, dual-intake with housing (without flange)

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

Product Data Sheet ACi 4420 MLR

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

Product Data Sheet ACi 4420 HHR

Hammond Electronic Rack Packaging

NCF fans 50 Hz. Protection class IP 55

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Provided Capacitor E: Single-Phase 220V/230V. Motor

AC centrifugal module - RadiCal

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD2412PTB1-6A

Product Data Sheet 4118 N/ The engineer's choice

Conforms to Power Supply Voltages in Asia Induction Motors, Reversible Motors, and Electromagnetic Brake Motors

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS BLOWER. DIMENSIONS : 45X45X9 mm M O D E L : GB0545AFV1-8

AC centrifugal fan with housing (small flange)

PSC Thermal Solutions. size 273 x 220 x202mm

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Product Data Sheet 4184 NXHH

Product Data Sheet DV5214 NU

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

Product Data Sheet 624 NR. The engineer's choice

Product Data Sheet 3214 JH3-195

PERFORMANCE SPECIFICATIONS SINGLE-SPEED, 110 CFM VENTILATION FAN

WOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS:

Product Data Sheet 4184 NXHH

Product Data Sheet 8412 N/ The engineer's choice

Product Data Sheet 4184 NGX

AC axial fan. blades with special design (K series) with guard grille for full nozzle

VHIA High-Static Ducted Indoor Units - 60HZ

Product Data Sheet DV4118 N

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 92X92X25 mm M O D E L : KD1209PTB1 P/N : (2).H

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Plate mounted axial flow fans HXBR / HXTR Series

Product Data Sheet 4184 N/17X. The engineer's choice

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

Product Data Sheet 4414/2H

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Low Static Pressure Duct(V shape evaporator)

Product Data Sheet 8412 NHU-519

Product Data Sheet 614 N/2HH-169 The engineer's choice

C B Motors CB I W U. Clutch and Brake Motors. Features. Product Number Code. Construction A ORIENTAL MOTOR GENERAL CATALOG

Product Data Sheet 632 NU-006

Product Data Sheet 3214 J/2H3F-191

Inside Front cover White

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Service manual MIV V4+ Indoor units

product specification

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 40X40X10 mm M O D E L : KD1204PFS2-8

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

Product Data Sheet 8414 NGH

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

Service Manual. Frequency (Hz) Noise (sones) < <0.3

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

AC axial fans, AC diagonal fans

MAX FLUID TEMPERATURE

FBA08A (80 X 25.5 L )

AC centrifugal fan. backward curved

Energy-saving motors (ESM)

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

AC axial fan. sickled blades (S series), single inlet Wall ring with guard grille

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

CUSTOMER: MODEL NO: 4020III (CeraDyna Fan) PART NO: FD1240-A0241D0AL DATE: CUSTOMER APPROVAL. Taiwan. Approved QC Checked Checked Prepared

FCVC Series VERTICAL FAN COILS

High Capacity Ventilation

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Low Static Pressure Duct (V shape evaporator)

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

AC axial fan. sickled blades (S series) Wall ring with guard grille

Watertight, Dust-Resistant. Motors. Standard AC Motors A-207. Standard AC Motors Intro duction. Motors. AC Speed Control Motors Inverter.

SINGLE STAGE TWO STAGES

AC Motor Systems US Series

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Vertical Air Handling Unit type

AC Line / Load Reactors

HIGH-POWERED VENTILATORS

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

CUSTOMER: MODEL NO: 4020II (CeraDyna Fan) NO: FD2440-C0151D2AL. DATE : September 3, 2007 CUSTOMER APPROVAL

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

Engineering Data Book

Transcription:

MB Series AC Centrifugal Blowers Impeller Diameter 6.3 in. dia. ( 16 mm) SAFETY STD. AC INPUT Specifications c Materials Motor Case: Casing: Impeller: Aluminum Voltage Frequency Current Input Power Max. Air Flow Max. Noise level V Hz A W r/min CFM m 3 /min in H2O Pa db(a) F Single-Phase 1 5 2.6 26 275 283 8. 1.97 49 76 MB1665-B Single-Phase 1 6 3.7 36 31 318 9. 2.76 686 8 4 Single-Phase 11 6 3.7 38 32 318 9. 2.76 686 8 Single-Phase 115 6 3.7 4 32 318 9. 2.76 686 8 Single-Phase 2 5 1.3 245 27 272 7.7 1.97 49 75 Single-Phase 2 6 1.8 34 3 297 8.4 2.76 686 76 MB1665-D Single-Phase 22 6 1.8 36 315 37 8.7 2.76 686 77 8. Single-Phase 23 5 1.3 27 275 283 8. 1.97 49 75 Single-Phase 23 6 1.8 37 315 314 8.9 2.76 686 77 Three-Phase 2 5 1.8 28 275 283 8. 1.97 49 76 MB1665-T Three-Phase 2 6 1.8 36 31 318 9. 2.76 686 8 Three-Phase 23 6 1.8 4 32 318 9. 2.76 686 8 Values for maximum air flow and maximum static pressure are measured by the double-chamber method. Noise level is measured in the A range, at a distance of 3.3 feet from the fan intake side. A thermal protector is installed. If the fan heats up, the thermal protector goes into operation and the fan stops. Once the fan temperature drops, it will automatically restart. Perform inspection work after turning off the power source. Fans bearing the CE mark should only be used with class1equipment. When installing into the equipment, either ground the fan or ensure that there is no contact with bare hands. Standards specifications are listed on page D-2. See page D-4 for VDE certified products. Air Flow Characteristics Audible Noise Frequency Analysis Measure at a distance of 3.3 feet from the fan intake side [r/min] 35 3 25 2 15 1 5 [in H2O] 3. 2.5 2. 1.5 1..5 [Pa] 7 6 5 4 3 2 1 5Hz 6Hz 5Hz Static Pressure 6Hz 2. 4. 6. 8. 1. 12. 14. Air Flow [m 3 /min] Noise Level(dB) 9 8 7 6 5 4 3 6Hz 5Hz 31.5 63 125 25 5 1K 2K 4K 8K 16K 1/3 Octave Band Center Frequency [Hz] 1 2 3 4 Air Flow [CFM] C-72 2-21 ORIENTAL MOTOR GENERAL CATALOG

Dimensions Scale1/4, Unit inch (mm) Weight (Mass): 11 lb. (5kg) 4.76 DIA. ( 121) 4.45(113) 8.74(222) (2) 3.94(1).39(1) AIR FLOW 3.27(83) 2.99(76) 8.98(228) 3.66(93) 1.57(4) PROTECTIVE EARTHING TERMINAL M4 8mm PROTECTIVE EARTHING MARK.39 DIA.( 1) UNPAINTED.98 (25) ROTATION 22.5.96(24.5) 8.94(227) 5.2 DIA.( 132) 3.54( 9) 1.18 (3) 3-LEADS 11.81(3) UL Style 3271, AWG2.51(13).28(7) 2.99(76) A 5.2 DIA. ( 132).17DIA ( 4.3) (2).24(6).16(4) C Panel Cut-Out Scale1/4, Unit inch (mm) ( and capacitor cap are provided with the blower.) 3.66(93) B B+.59(15).28(7).39 (1) R.39(1) Intake side Outlet side MB1665-B MB1665-D Dimensions inch (mm) Weight (Mass) A B C oz. (g) CH4CFAUL 2.28 (58) 1.61 (41) 2.28 (58) 6.7 (19) CH8BFAUL 2.28 (58) 1.14 (29) 1.61 (41) 5.3 (15) Wiring Diagrams MB1665-B, D Line Black Red White Accessories (Sold separately) Item Page Mounting PAS5A C-18 MB1665-T U Line V W Black Red White Mounting 2-21 ORIENTAL MOTOR GENERAL CATALOG C-73

MB Series AC Centrifugal Blowers Impeller Diameter 4.72 in. dia. ( 12 mm) SAFETY STD. AC INPUT Specifications MB1255-B c Materials Motor Case: Casing: Impeller: Voltage Frequency Current Input Power Max. Air Flow Max. Noise level V Hz A W r/min CFM m 3 /min in H2O Pa db(a) F Single-Phase 1 5 1.3 11 285 155 4.4 1.24 39 67 Single-Phase 1 6 1.6 15 33 18 5.1 1.77 441 71 Single-Phase 11 6 1.6 15 33 18 5.1 1.77 441 71 Aluminum Single-Phase 115 6 1.6 15 33 18 5.1 1.77 441 72 Single-Phase 2 5.6 11 285 155 4.4 1.26 314 67 Single-Phase 2 6.8 145 32 173 4.9 1.81 451 69 MB1255-D Single-Phase 22 6.8 145 33 18 5.1 1.81 451 71 2. Single-Phase 23 5.6 11 29 159 4.5 1.26 314 67 Single-Phase 23 6.8 15 33 184 5.2 1.81 451 71 Values for maximum air flow and maximum static pressure are measured by the double-chamber method. Noise level is measured in the A range, at a distance of 3.3 feet from the fan intake side. A thermal protector is installed. If the fan heats up, the thermal protector goes into operation and the fan stops. Once the fan temperature drops, it will automatically restart. Perform inspection work after turning off the power source. Fans bearing the CE mark should only be used with class1equipment. When installing into the equipment, either ground the fan or ensure that there is no contact with bare hands. For protection, use the optional finger guard. Standards specifications are listed on page D-2. See page D-4 for VDE certified products. 1 Air Flow Characteristics Audible Noise Frequency Analysis Measure at a distance of 3.3 feet from the fan intake side [r/min] 45 4 35 3 25 2 15 1 5 [in H2O] 1.6 1.4 1.2 1..8.6.4.2 [Pa] 45 4 35 3 25 2 15 1 5 5Hz 6Hz 5Hz Static Pressure 6Hz 1. 2. 3. 4. 5. 6. 7. Air Flow [m 3 /min] Noise Level(dB) 8 7 6 5 4 3 2 6Hz 5Hz 31.5 63 125 25 5 1K 2K 4K 8K 16K 1/3 Octave Band Center Frequency [Hz] 5 1 15 2 Air Flow [CFM] C-74 2-21 ORIENTAL MOTOR GENERAL CATALOG

Dimensions Scale1/4, Unit inch (mm) Weight (Mass): 8.8 lb. (4kg) PROTECTIVE EARTHING MARK.39 DIA.( 1) UNPAINTED.98 (25) PROTECTIVE EARTHING TERMINAL M4 8mm 7.5(179).26(6.5) 2.56(65).8(2) 2.28(58).39(1) 6.85(174) 3.54(9) 3.9(78.5) AIR FLOW 3.35(85) 1.18 (3) 4.2 DIA.( 12) 3.78 DIA.( 96) 6.93(176).59 (15) 22.5 3.31 DIA. ( 84) ROTATION.51(13) 3-LEADS 11.81(3) UL Style 3271, AWG2.71 (18) Panel Cut-Out Scale1/4, Unit inch (mm) 2.3(58.5) ( and capacitor cap are provided with the blower.) A 3.9(78.5) 3.78 DIA. ( 96).17DIA. ( 4.3) (2) B.18(4.5) B+.39(1).39 (1).24(6) Outlet side Intake side.16(4) C MB1255-B MB1255-D CH1CFAUL Dimensions inch (mm) Weight (Mass) A B C oz. (g) 1.89 (48).89 (22.5) 1.24 (31.5) 1.4 (4) CH2BFAUL 1.89 (48).75 (19) 1.14 (29) 1.4 (4) Wiring Diagram Black Red White Line Accessories (Sold separately) Item Page Finger Guard FGB12 C-1 Filter FLB12 C-13 Mounting PAS6A C-18 Duct Joint FD12 C-19 Filter Duct Joint Mounting A finger guard can be installed in place of the filter. 2-21 ORIENTAL MOTOR GENERAL CATALOG C-75

MB Series AC Centrifugal Blowers Impeller Diameter 3.94 in. dia. ( 1 mm) SAFETY STD. AC INPUT Specifications MB14-B c Materials Motor Case: Casing: Impeller: Voltage Frequency Current Input Power Max. Air Flow Max. Noise level V Hz A W r/min CFM m 3 /min in H2O Pa db(a) F Single-Phase 1 5.5 45 275 81.2 2.3.83 26 6 Single-Phase 1 6.55 55 35 91.8 2.6 1.14 284 63 Single-Phase 11 6.55 55 32 91.8 2.6 1.14 284 64 Aluminum Single-Phase 115 6.55 55 32 91.8 2.6 1.14 284 64 Single-Phase 2 5.25 4 275 81.2 2.3.83 26 61 Single-Phase 2 6.3 5 31 91.8 2.6 1.22 34 64 MB14-D Single-Phase 22 6.3 55 32 95.3 2.7 1.22 34 65 1.2 Single-Phase 23 5.3 5 275 84.8 2.4.83 26 61 Single-Phase 23 6.3 55 325 95.3 2.7 1.22 34 65 Values for maximum air flow and maximum static pressure are measured by the double-chamber method. Noise level is measured in the A range, at a distance of 3.3 feet from the fan intake side. A thermal protector is installed. If the fan heats up, the thermal protector goes into operation and the fan stops. Once the fan temperature drops, it will automatically restart. Perform inspection work after turning off the power source. Fans bearing the CE mark should only be used with class 1 equipment. When installing into the equipment, either ground the fan or ensure that there is no contact with bare hands. For protection, use the optional finger guard. Standards specifications are listed on page D-2. See page D-4 for VDE certified products. 3. Air Flow Characteristics Audible Noise Frequency Analysis Measure at a distance of 3.3 feet from the fan intake side [r/min] 4 35 [in H2O] 1.2 [Pa] 28 1. 3 24 25.8 2 2.6 16 15 12.4 1 8.2 5 4.4.8 Static Pressure 1.2 5Hz 6Hz 5Hz 6Hz 1.6 2. 2.4 2.8 Air Flow [m 3 /min] 2 4 6 8 Air Flow [CFM] Noise Level(dB) 8 7 6 5 4 3 2 31.5 63 125 25 5 1K 2K 4K 8K 16K 1/3 Octave Band 6Hz 5Hz Center Frequency [Hz] C-76 2-21 ORIENTAL MOTOR GENERAL CATALOG

Dimensions Scale1/4, Unit inch (mm) Weight (Mass): 4.4 lb. (2kg) PROTECTIVE EARTHING MARK.39 DIA.( 1) UNPAINTED.98 (25) PROTECTIVE EARTHING TERMINAL M4 8mm 1.81 (3) 3.11 DIA.( 79) 5.28(134).18(4.5) 1.97(5).8(2) 1.75(44.5).39(1) 2.72(69) 3.39 DIA ( 86) AIR FLOW 6.14(156) 2.95(75).59 (15) 22.5 5.83(148) 2.91(74) 2.91 DIA. ( 74) ROTATION.39(1) 3-LEADS 11.81(3) UL Style 3266, AWG2.47 (12) Panel Cut-Out Scale1/4, Unit inch (mm) 1.75(44.5) ( and capacitor cap are provided with the blower.) A 2.72(69) 3.39 DIA. ( 86).17DIA. ( 4.3) (2) B.18(4.5) B+.39(1).39 (1).24(6) Outlet side Intake side.16(4) C MB14-B MB14-D Dimensions inch (mm) Weight (Mass) A B C oz. (g) CH3BFAUL 2.28 (58).83 (21) 1.22 (31) 1.8 (5) CH12BFAUL 1.46 (37).71 (18) 1.6 (27) 1.1 (3) Wiring Diagram Black Red White Line Accessories (Sold separately) Item Page Finger Guard FGB1 C-1 Filter FLB1 C-13 Mounting PAS4B C-18 Duct Joint FD1 C-19 Filter Duct Joint Mounting A finger guard can be installed in place of the filter. 2-21 ORIENTAL MOTOR GENERAL CATALOG C-77

MB Series AC Centrifugal Blowers Impeller Diameter 3.15 in. dia. ( 8 mm) SAFETY STD. AC INPUT Specifications MB84-B c Materials Motor Case: Casing: Impeller: Voltage Frequency Current Input Power Max. Air Flow Max. Noise level V Hz A W r/min CFM m 3 /min in H2O Pa db(a) F Single-Phase 1 5.29 28 28 56.5 1.6.61 152 55 Single-Phase 1 6.37 32 315 63.6 1.8.89 221 58 Single-Phase 11 6.37 35 33 63.6 1.8.91 226 59 Aluminum Single-Phase 115 6.37 36 335 63.6 1.8.91 226 59 Single-Phase 2 5.14 28 28 56.5 1.6.61 152 55 Single-Phase 2 6.18 32 32 63.6 1.8.89 221 58 MB84-D Single-Phase 22 6.18 35 335 63.6 1.8.91 226 59 2.5 Single-Phase 23 5.15 35 285 56.5 1.6.63 157 55 Single-Phase 23 6.18 36 335 63.6 1.8.91 226 59 Values for maximum air flow and maximum static pressure are measured by the double-chamber method. Noise level is measured in the A range, at a distance of 3.3 feet from the fan intake side. A thermal protector is installed. If the fan heats up, the thermal protector goes into operation and the fan stops. Once the fan temperature drops, it will automatically restart. Perform inspection work after turning off the power source. The MB84 is protected with impedance protection that prevents the temperature from rising to the temperature at which the thermal protector is triggered even if the fan is locked due to the usage voltage or ambient temperature. Fans bearing the CE mark should only be used with class 1 equipment. When installing into the equipment, either ground the fan or ensure that there is no contact with bare hands. For protection, use the optional finger guard. Standards specifications are listed on page D-2. See page D-4 for VDE certified products. 1.5 Air Flow - Characteristics [r/min] 4 35 3 25 2 15 1 5 [inh2o] 1.2 1..8.6.4.2 [Pa] 28 24 2 16 12 8 4.4.8 5Hz 1.2 5Hz 6Hz Static Pressure 6Hz 1.6 2. 2.4 2.8 Air Flow [m 3 /min] 2 4 6 8 Air Flow [CFM] Audible Noise Frequency Analysis Measure at a distance of 3.3 feet from the fan intake side Noise Level(dB) 6 5 4 3 2 1 31.5 63 125 25 5 1K 2K 4K 8K 16K 1/3 Octave Band 6Hz 5Hz Center Frequency [Hz] C-78 2-21 ORIENTAL MOTOR GENERAL CATALOG

Dimensions Scale1/4, Unit inch (mm) Weight (Mass): 2.9 lb. (1.3kg) PROTECTIVE EARTHING MARK.39DIA. UNPAINTED.98 (25) PROTECTIVE EARTHING TERMINAL M4 8mm 4.49(114) 1.97(5) 1.73(44).8(2).39(1) 2.36(6) 4.8(122) 1.81 (3) 3.15DIA.( 8) 2.13 (54) 2.99DIA.( 76) AIR FLOW 5.4(128).55(14) 2.36(6) 22.5 2.52DIA. ( 64) ROTATION.22.51(13) (5.5) 3-LEADS 11.81(3) UL Style 3266, AWG2.39(1) Panel Cut-Out Scale1/4, Unit inch (mm) 1.73(44) ( and capacitor cap are provided with the blower.) A 2.13(54) 2.99 DIA. ( 76).17DIA. ( 4.3) (2) B.18(4.5) B+.39(1).39 (1).24(6) Outlet side Intake side.16(4) C MB84-B MB84-D CH15FAUL Dimensions inch (mm) Weight (Mass) A B C oz. (g) 1.22 (31).57 (14.5).93 (23.5) 1.2 (35) CH25FAUL 1.22 (31).67 (17) 1.6 (27) 1.4 (4) Wiring Diagram Black Red White Line Accessories (Sold separately) Item Page Finger Guard FGB8 C-1 Filter FLB8 C-13 Mounting PAS4B C-18 Duct Joint FD8 C-19 Filter Duct Joint Mounting A finger guard can be installed in place of the filter. 2-21 ORIENTAL MOTOR GENERAL CATALOG C-79

MB Series AC Centrifugal Blowers Impeller Diameter 2.36 in. dia. ( 6 mm) SAFETY STD. AC INPUT Specifications c Materials Motor Case: Casing: Impeller: Voltage Frequency Current Input Power Max. Air Flow Max. Noise level V Hz A W r/min CFM m 3 /min in H2O Pa db(a) Single-Phase 1 5.11 8. 23 15.5.44.21 53 37 MB63-B Single-Phase 1 6.11 8. 19 12.7.36.3 76 33 Single-Phase 11 6.12 9.5 23 15.9.45.31 77 38 Single-Phase 115 6.12 1. 25 17.3.49.31 79 4 Single-Phase 2 5.8 12. 25 17.3.49.224 56 38 Single-Phase 2 6.8 11. 26 17.7.5.334 83 39 MB63-D Single-Phase 22 6.8 13. 29 19.4.55.334 83 42 Single-Phase 23 5.9 16. 26 17.7.5.224 56 39 Single-Phase 23 6.8 14. 29 19.4.55.334 83 43 Aluminum Values for maximum air flow and maximum static pressure are measured by the double-chamber method. Noise level is measured in the A range, at a distance of 3.3 feet from the fan intake side. These products are impedance protected. Fans bearing the CE mark should only be used with class1equipment. When installing into the equipment, either ground the fan or ensure that there is no contact with bare hands. Standards specifications are listed on page D-2. Air Flow - Characteristics Audible Noise Frequency Analysis Measure at a distance of 3.3 feet from the fan intake side [r/min] 4 8.3 35 7 3 25 2 15 1 5 [in H2O].25.2.15.1.5 [Pa] 6 5 4 3 2 1 5Hz 5Hz 6Hz Static Pressure 6Hz Noise Level(dB) 6 5 4 3 2 1 6Hz 5Hz 31.5 63 125 25 5 1K 2K 4K 8K 16K 1/3 Octave Band Center Frequency [Hz].1.2.3.4.5.6.7 Air Flow [m 3 /min] 5 1 15 2 Air Flow [CFM] C-8 2-21 ORIENTAL MOTOR GENERAL CATALOG

Dimensions Scale1/4, Unit inch (mm) Weight (Mass): 1.1 lb. (.5kg) PROTECTIVE EARTHING MARK.39DIA.( 1) UNPAINTED.59 PROTECTIVE (15) EARTHING TERMINAL M4 8mm (2) 2.36DIA. ( 6) 1.42(36) 2.95(75) 1.57(4) 1.38 (35).4(1).24(6) 1.89DIA. ( 48).35(9).4(1) AIR FLOW 2.64DIA. ( 67) 3.54(9).39(1) 1.57(4) 3.54(9) 1.81(46).31(8) 22.5 3-M3P.5 1.65DIA. ( 42).28DIA. ( 7) ROTATION 2-LEADS 11.81(3) UL Style 3266, AWG2 Panel Cut-Out Scale1/4, Unit inch (mm) 1.38 (35) 1.42 (36).14 DIA. 3 HOLES ( 3.5) 1.89 DIA. ( 48) 12 2.64 DIA. ( 67) Outlet side Intake side Wiring Diagram Line Accessories (Sold separately) Item Page Mounting PAS2B C-18 Mounting 2-21 ORIENTAL MOTOR GENERAL CATALOG C-81

MB Series AC Centrifugal Blowers Impeller Diameter 1.97 in. dia. ( 5 mm) SAFETY STD. AC INPUT Specifications c Materials Motor Case: Casing: Impeller: Voltage Frequency Current Input Power Max. Air Flow Max. Noise level V Hz A W r/min CFM m 3 /min in H2O Pa db(a) Single-Phase 1 5.11 8 26 7.4.21.149 37 33 MB52-B Single-Phase 1 6.1 7 3 8.5.24.212 53 37 Single-Phase 11 6.11 8.5 32 8.8.25.22 55 38 Single-Phase 115 6.11 9 32 8.8.25.22 55 38 Single-Phase 2 5.9 11 265 7.8.22.153 38 33 Single-Phase 2 6.8 1 32 9.5.27.232 58 38 MB52-D Single-Phase 22 6.9 12 33 9.5.27.24 6 38 Single-Phase 23 5.1 16 275 8.1.23.161 4 33 Single-Phase 23 6.9 13 33 9.5.27.24 6 38 Aluminum Values for maximum air flow and maximum static pressure are measured by the double-chamber method. Noise level is measured in the A range, at a distance of 3.3 feet from the fan intake side. These products are impedance protected. Fans bearing the CE mark should only be used with class1equipment. When installing into the equipment, either ground the fan or ensure that there is no contact with bare hands. Standards specifications are listed on page D-2. Air Flow - Characteristics Audible Noise Frequency Analysis Measure at a distance of 3.3 feet from the fan intake side [r/min] 4 8.3 35 7 3 25 2 15 1 5 [in H2O].25.2.15.1.5 [Pa] 6 5 4 3 2 1 5Hz 5Hz 6Hz Static Pressure 6Hz Noise Level(dB) 6 5 4 3 2 1 6Hz 5Hz 31.5 63 125 25 5 1K 2K 4K 8K 16K 1/3 Octave Band Center Frequency [Hz].4.8.12.16.2.24.28 Air Flow [m 3 /min] 2. 4. 6. 8. Air Flow [CFM] C-82 2-21 ORIENTAL MOTOR GENERAL CATALOG

Dimensions Scale1/4, Unit inch (mm) Weight (Mass):.66 lb. (.3kg) PROTECTIVE EARTHING MARK.39DIA. ( 1) UNPAINTED.39(1) PROTECTIVE EARTHING TERMINAL M4 8mm (2) 2.36DIA. ( 6) 2.26(57.5).98 (25) 1.42 (36).2(.5).16(4).81(2.5) 1.57.DIA ( 4).31(8).2(.5) 2.2DIA. ( 56) AIR FLOW 3.7(78) 1.57(4).16(4).31 (8) 1.57(4) 3.7(78) 22.5 3-M3P.5 1.42DIA. ( 36).28DIA. ( 7) ROTATION 2-LEADS 11.81(3) UL Style 3266, AWG2 Panel Cut-Out Scale1/4, Unit inch (mm).81(2.5) 12 1.42(36).14 DIA. 3 HOLES ( 3.5) 1.57 DIA. ( 4) 2.2 DIA. ( 56) Outlet side Intake side Wiring Diagram Line Accessories (Sold separately) Item Page Mounting PAS2B C-18 Mounting 2-21 ORIENTAL MOTOR GENERAL CATALOG C-83