AquaMatic Series. A100 and A200 Stager Controls

Similar documents
AQT-275 SERIES SERVICE MANUAL CONTROL VALVES

AquaMatic Control Valves, Stagers and Controllers

SRC. An Outdoor Reset Control for Sub-Atmosphere Steam Systems OUTDOOR TEMPERATURE

AQUAMATIC CONTROL VALVES, STAGERS AND CONTROLLERS

WATER SOFTENER SERIES DAY TIMER INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

AquaMatic Products. Valves, Stagers and Controllers OVERVIEW. GE Water & Process Technologies

or OWNER S MANUAL MODEL R

3200NT Timer Service Manual

Commercial Softeners

65 Series. Valve Operation Manual

COMMERCIAL CONTROL VALVES. Magnum Control Valve

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS

INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES

Installation and Operations Manual

IRON & MANGANESE REMOVAL FILTER INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

AQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES

INDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES

FLECK 2900S SERVICE MANUAL. waterpurification.pentair.com

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

PRESSURE GAGES AND TEST TAPS

Installation and Operations Manual

Chemical Free Iron Sulphur Filtration System Owner's Operation and Maintenance Manual

Pre-Treatment Control Valve (Fleck 2850s) & Timer (Fleck SXT)

FLECK 2850S SERVICE MANUAL. waterpurification.pentair.com

DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS

Logix Magnum IT and Cv Valves. Installation and Service Manual

Pressure Independent Control Series

Model Downlow & Uplow

FLECK 2750 DOWNFLOW SERVICE MANUAL. waterpurification.pentair.com

PMV P36C AND P41C POSITIONERS ACTUATORS

TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES WATER PURIFICATION VALVES - AUTOTROL

FLECK 5600 SERVICE MANUAL. waterpurification.pentair.com

Fleck 2510 Manual Sediment Filter Installation & Start-Up Guide

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

INSTALLATION, OPERATING AND SERVICE MANUAL

WATER SOFTENER SEMI AUTOMATIC INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

Pressure Independent Control Series

Richdel 300 SERIES MECHANICAL CONTROLLERS INSTALLATION AND OPERATING GUIDE FOR ALL MODELS

FLECK 2850 CONTROL VALVE

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

To ensure proper installation, digital pictures with contact information to before startup.

FLECK 2750 DOWNFLOW SERVICE MANUAL.

Pre-Treatment Control Valve (Fleck 3150) & Timer (Fleck SXT)

Troubleshooting Bosch Proportional Valves

Model 7000XTR. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

Superior Water And Air OWNER S MANUAL Model 32-CL770 & 48-CL770

DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

F76 Water Filters. Specifications. and MV876 Automatic-Backwash Control Accessory (not included)

Specifications. Autotrol 255 Valve. Autotrol 255 Series Valve Specifications. Flow Rates (Valve Only) Regeneration Operation

Cleaning Systems Inc. 2 P Rev:03

Water Specialist PR Control Valve Programming and Cover Drawing Manual

wd-2

DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions

CONTROLLERS & SPECIAL VALVES

CAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER

3 Spin Klin Battery Operation and Maintenance Manual

GAA. GasApps Australia P/L. MultiTimer MKII. Manual. Prepared By GasApps Australia P/L 2/11/05

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Tech Manual Powerline Filter (PF) Series

INSTALLATION/OPERATING INSTRUCTIONS TSC

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

INSTALLATION/OPERATING INSTRUCTIONS MCP

Updated: October 2012

Fleck 2510 & 2510 Econominder

INSTRUMENTATION & CONTROL

MF /MS Series

CAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø

LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

Owners Manual Installation Instructions. For Models PTCF PTCF PTCF

3200ET TIMER. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

Superior Water And Air

AQUASWITCH AQUASWITCH & 760-A AQUASWITCH

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

Nordson Airless Nozzle Tester

12 STATION MANUAL CONTROLLER INSTALLATION AND OPERATING GUIDE MODEL HRM-12

Light switch timer 3 step Installation overview 3 minute quick programming guide. A police accredited product.

Value Super Filter Max Installation Manual

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

Instruction Manual. Series E7 Metering Pumps. For file reference, please record the following data:

Magnum Cv Valve Specifications. Magnum IT and Standard Configurations. imagination at work

255 Valve Specifications

Senior Swing Control Box. Table of Contents

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

TNT SERIES WATER CONDITIONERS

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

Clean and soft water for business needs. Commercial softening equipment. COMMERCIAL WATER SOFTENERS

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

DF Series Hydrostatic Head Level Switches

PARTS LIST CONTROL PANEL COMPONENTS

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

REVISION HISTORY REVISION HISTORY

SILVER COMPOSITE SERIES VALVE Manufactured After June, 2000

Transcription:

AquaMatic Series A100 and A200 Stager Controls

2

Table of Contents Introduction To AquaMatic Series A100 and A200 Stager Controls3 Specifications 4 Applications 5 Features 6 Cycle Time Programming 7 Setting A100 Regeneration Frequency 9 Series A100 Standard Wiring Diagram 10 Series A200 Standard Wiring Diagram 11 Regeneration Initiation Options 12 Troubleshooting 13 Table of Contents 3

Introduction To AquaMatic Series A100 and A200 Stager Controls This series of AquaMatic controls combines an electromechanical timer with a stager. A stager is a rotary pilot valve with multiple ports through which control fluid (air or water) is directed to either pressurize or vent AquaMatic diaphragm valves. Control of a wide range of water treatment systems such as water softeners and filters is possible. Customer applications are also available. There are two base models which vary with regard to the timer furnished. The A100 series initiates a regeneration based on a time set on the built-in time clock. The A200 series initiates a regeneration when a signal is received from a water meter, sensor, pressure differential switch, push button or other remote device. Either series of controls is equipped with a cycle timer which may have from one to 10 cycles if desired. The maximum cumulative time available for timed cycles is 102 minutes. The cycle times can be programmed in three minute increments with a minimum cycle length of three minutes. A variety of stager models may be used with the A100 and A200 series controls. There are five stager designs available: Series 48 brass stager with six ports Series 51 and 96 brass stagers with eight ports Series 58 PVC stager and 59 brass stager with sixteen ports The 48 stager can control typical softener or filter systems as well as sequential backwash filters. For more complex systems such as non-standard softeners, twin alternating softeners or filters, the 51 or 58 stagers are required. The 96 stager design is similar to that of the 51, but is rated for 250 psi (17 bar) and used for high pressure systems. The 59 brass stager design is identical to the 58 PVC stager. 4 Introduction To AquaMatic Series A100 and A200 Stager Controls

Specifications Power Requirements:....................................................... 120 VAC/60 Hz/3 Watts 220 VAC/50 Hz/3 Watts 220 VAC/60 Hz/3 Watts 24 VAC/50 Hz/3 Watts Initiation Signal (A200 only):............................. Line voltage (minimum of 3 minute signal duration) Stager Port Sizes:.............................. All inlet, control, and drain ports have 1/8 inch NPT threads (except Series 58 and 59 inlet and drain ports are 1/4 inch NPT) Control Fluid:................................................................. Clean Air or Water Control Pressure:................................ 125 psi (8.5 bar) maximum for Series 48, 51, 58, and 59 250 psi (17 bar) maximum for Series 96 stager Control Temperature:....................................................140 o F (60 o C) (Atmospheric) Enclosure Options:.................................................................. NEMA 1 NEMA 4 NEMA 4XFG Specifications 5

Applications Single Unit Controls Model Number Typical Softeners and Filters Time Initiated Signal Initiated A148 A248 More Complex Softeners and Filters Time Initiated Signal Initiated A151 A251 High Pressure (250 psi/17 bar) Stagers for Typical and Complex Softeners and Filters Time Initiated Signal Initiated A196 A296 Multiple Unit Controls Model Number Twin Alternating Softeners and Filters Time Initiated Signal Initiated A158TA A258TA Sequential Filters (Backwash Only) Time Initiated Signal Initiated A148 A248 2 Unit Sequential Filters (Backwash and Rinse) Time Initiated Signal Initiated A151 A251 3 or 4 Unit Sequential Filters (Backwash and Rinse) Time Initiated Signal Initiated A158 A258 6 Applications

Features Standard Features: NEMA 1 Enclosure 120 VAC/60 Hz/3 Watts Homing Feature If the stager gets out of sequence with the timer, the homing feature returns the stager to the service position when the timer returns to the service position. 7 Day Time Clock (Series A100 only) Optional Features: NEMA 4 or NEMA 4XFG Enclosure 220 VAC/50 Hz/3 Watts 220 VAC/60 Hz/3 Watts 24 VAC/50 Hz/3 Watts 6 Day Time Clock (Series A100 only) External push-button for Regeneration (Series A200 only) Status Lights Extra cam and switch option to provide either a dry or powered contact closure during any or all cycles Features 7

Cycle Time Programming Series A100 and A200 1. Remove the thumbscrew from the mounting bracket of the timer and swing the timer to the left. 2. Pull up on the first pin (Start Cycle #1) of the pinwheel to mark the start of the regeneration sequence (see Figure 1). 3. Use the PIN TIME CHART below, to determine the number of pins to be left in the DOWN position. The number of pins left in the DOWN position represent the duration of the cycle (each pin equals approximately 3 minutes). 4. Pull up the pin that represents start of the next cycle (Start Cycle #2) and repeat step 3 to determine the duration of this cycle. 5. Repeat steps 3 and 4 as needed for the remainder of steps in the regeneration process. The last pin that is left in the UP position will send the controller back into the Service position. 6. Return the timer to the proper mounting position and secure it using the thumbscrew provided. Ensure that all electrical wires are located away from the bottom of the timer. NOTE: The number of pins in the UP position on the pinwheel must equal exactly the number of positions of the stager. Total regeneration time cannot exceed 102 minutes. PIN TIME CHART Number of Pins DOWN Time (Min.) Number of Pins DOWN Time (Min.) Number of Pins DOWN Time (Min.) 0 3 12 39 24 75 1 6 13 42 25 78 2 9 14 45 26 81 3 12 15 48 27 84 4 15 16 51 28 87 5 18 17 54 29 90 6 21 18 57 30 93 7 24 19 60 31 967 8 27 20 63 32 99 9 30 21 66 33 102 10 33 22 69 11 36 23 72 8 Cycle Time Programming

3 MIN/PIN Cycle Time Programming (Continued) Start cycle #3 Cycle #2 = 45 min Cycle #3 = 9 min Return to service 60 48 36 24 72 84 12 Start cycle #2 96 0 Cycle #1 = 15 min Service notch Start cycle #1 (First pin) Pin up Pin down Figure 1 Typical Pinwheel Setting Cycle Time Programming 9

Setting A100 Regeneration Frequency Setting Days: 1. Pull all skipper pins outward away from dial face (see Figure 2). 2. Rotate skipper wheel until Day Arrow is aligned with either the current day (for the 7 day wheel) or the number 1 (for the 6 day wheel). 3. Depress skipper pin(s) at day(s) regeneration is desired. Setting Time of Day: 1. Grasp timer knob and pull outward. 2. Rotate in either direction until actual time of day is aligned with Time Arrow. 3. Release timer knob. NOTE: With the time of day properly set, the controller will regenerate at approximately 2:30 AM. If you prefer to have the unit regenerate at an earlier or later time, set the current time of day accordingly. A label has been provided so that you can apply it to indicate the correct time of day. EXAMPLE: To set the unit to regenerate at 4:30 AM (2 hours later), set the clock 2 hours earlier than the actual current time. Position the label provided on the 24 hour dial while aligning the mark of the current time with the Time Arrow. Press the label in place. NOON 3 PM 9 AM Timer knob 6 PM 6 AM Skipper wheel PM 3 AM 24-hour dial Skipper pin SUN SAT MIDNIGHT MON FRI Time arrow Day arrow TUE WED DAY THU START SERVICE Pointer knob Figure 2 A100 Timer Faceplate 10 Setting A100 Regeneration Frequency

Series A100 Standard Wiring Diagram 2 Line Power Supply Neutral 1 Timer 4 Motor M White Aquamatic Stager 3 C. Upper Timer Switch N. O. N.C. Red (Run) Orange (Start) N.O. C. N.C. Black Index Switch Motor M Black White (Neutral) 6 C. N. O. Lower Timer Switch N. C. Blue 10 9 Blue C. N. O. 1st Aux. Switch N.C. (Homing - Shown In Service) Violet Yellow 7 8 5 Output During Timer Regeneration Figure 3 Series A100 Standard Wiring Diagram 11

Series A200 Standard Wiring Diagram 2 Line Power Supply Neutral 1 Timer Aquamatic Stager 4 C. N. O. Upper Timer Switch N.C. Red (Run) Orange (Start) N.O. C. N.C. Black Index Switch Motor M Black White (Neutral) 6 3 C. N.O. Internal N.C. Timer Switch (Shown in SVC.) Blue 10 9 Blue C. 1st Aux. Switch (Homing - Shown In Service) N.O. N.C. Violet Yellow 7 8 MOTOR M WHITE Grey 5 Initiation Signal Input Figure 4 12 Series A200 Standard Wiring Diagram

Regeneration Initiations Options Series A100: Manual (internal): Automatic: Open enclosure. Depress RED BUTTON and turn counterclockwise to the START position (see Figure 2). Preset day and time. Series A200: Manual Regeneration (internal):open enclosure. Depress RED BUTTON and release. External Electrical Signal: (3 minute duration) Differential Pressure Switch, water meter, or other remote device (See Figure 5). Series A200 Regeneration Initiation Options 1 2 3 Badger Auto Reset Meter With Relay Less Relay 3 4 5 6 7 8 5 4 1 2 3 45 6 3 5 4 Badger Model AR/E 1 2 3 4 5 3 4 6 5 E ARTH G R OUND Pressure Differential Switch Neptune 25B Reset Meter 4 5 Minimum 3 Minute Switch Closure 5 4 3 Figure 5 Regeneration Initiations Options 13

Troubleshooting Problem Solution Timer and Stager are out of sequence. Check that the number of pins that are in the UP position on the timer pinwheel (Figure 2), match EXACTLY the number of notches in the stager cam assembly Make sure that there are no wires coming in contact with the pinwheel assembly. Manually rotate the stager assembly to the Service position. Then, check the operation of the timer pinwheel assembly by depressing and then releasing the micro-switch located on the pinwheel. You can repeat this for each step of the regeneration cycle to ensure that the stager and timer are working properly. Verify the connections of the Homing feature. (If Applicable, See Figures 3 and 4) Stager does not advance automatically, Initiation signal will not start the control. (A200 Stager Control Only) Manually rotate the stager assembly approximately 1/4 inch. The stager motor should take over the operation and advance the stager to the next step. The Homing feature will return the stager to the Service position automatically. Verify that all wiring connections are made correctly. (See Figures 3 and 4) Check that the correct voltage and frequency are being used as specified for the control. Verify that the initiation signal is connected properly to terminal #5 on TB1. (See Figure 4) Check that the correct voltage and frequency are being used as specified for the initiation input signal. Ensure that the initiation signal has a minimum duration of 3 minutes. Check all wiring according to the wiring diagram provided with the control. 14 Troubleshooting

Troubleshooting 15

2009 Pentair Residential Filtration, LLC P/N 3007646 JA09