Input Voltage: AC: VAC HC: VAC (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL

Similar documents
SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Installation Instructions for Appleton Mercmaster LED Luminaire

Operation/Installation Instructions

Operating Instructions

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

INSTALLATION INSTRUCTION MANUAL

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

MODELS 2 & 4 Top Conduit Linears

SynergEX Panelboards for Hazardous Locations

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Operating Instructions

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

MODELS. 2 & 4 Low Profile Linears

INSTRUCTION MANUAL (ATEX / IECEx)

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

Champ MLL LED luminaires

FOR PROPER AND SAFE INSTALLATION OF THIS PRODUCT, PLEASE READ THE FOLLOWING INSTRUCTIONS.

HBDBM High Bay Series

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

INSTALLATION INSTRUCTION MANUAL

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

MODELS SafeSite LED Linear, Class I Div V, 2 & 4 Versions

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

Elle Surface Mounting Instructions

High Bay Luminaire Series

LED IMPORTANT SAFETY INSTRUCTIONS

INSTRUCTION SHEET. Installation Instructions for Mercmaster LED Luminaire. Applications. Agency Ratings. Product Safety

XPF. XPFMax Performer/al FEATURES TECHNICAL SPECIFICATIONS

Operating Instructions

Installation Instructions MX LED Enhanced Color Adjustable

CYCLOPS Z Purge Indicator

Applications. Illustrated Features

INSTRUCTION MANUAL (ATEX / IECEx)

CFP-LED Contractor Select Flat Panel. Installation Instructions


Lumination TM LED Luminaires LAL Series - Continuous Run Option

80 Watt Multi-Purpose LED Area Light

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

APPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional.

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

003 3 foot foot RUN Nominal Length* * For actual lengths see

When using electrical equipment, basic safety precautions should always be followed including the following:

LEDMPAL15 15 Watt Multi-Purpose LED Area Light

FHEZ10A24 FHEZ10A24 - CEC 24" EZ EXIT EM T-Grid

CYCLOPS Z Purge Indicator

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

Elle Surface Mounting Instructions

Max. Input Power (W) Inrush Current (A pk /µs)

Installation Instructions 4 Gravity Enhanced Color Adjustable

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Project: Type: Qty: QH2L. Options QH2L 27 3 /8" 23 3 /16" 3 1 /2" O.D. Pole. Options

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

CFL-LED-KIT Compact FloodLight, LED 2.0 Upgrade Kit kl_cfl_ledkit_spec.pdf

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

LED Adjustable Cutoff Wallpack

C4S SERPENTINE LED LINEAR COVE LIGHTING, MID-POWER

SAVE THESE INSTRUCTIONS

Operating Instructions

LED IMPORTANT SAFETY INSTRUCTIONS

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations

LED lighting for drilling & marine Pauluhn ZPL LED luminaires. Pauluhn ZPL. LED luminaires for drilling & marine applications

LAL SERIES LED LUMINAIRE

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

30in Phoebe Round Crystal Chandelier Assembly Instructions

Installation Instructions MX LED Downlight Remodel

LED CANOPY with j-box

OPERATING INSTRUCTIONS

Operating Instructions

NON MAINTAINED/MAINTAINED EMERGENCY LUMINAIRES WITH WHITE LEDs

MASTERsine Inverter PXA Series Installation Guide

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

MEDMASTER DOWNLIGHT Luminaires for Surgical Applications

Capella 3. Project Name. Construction. Optical System. Product Applications

HAZARDOUS LOCATION STREET LIGHT SLA SERIES INSTALLATION INSTRUCTIONS

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

IMPORTANT SAFETY INSTRUCTIONS

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

LED UFO High Bay with j-box Installation Instruction

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

ILED Aquarius Illuminated Windsock. User Manual

Qty: B B lm/6.9W per foot. per foot. 2B lm/15.3W per foot. 2B lm/13.

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Installation and Maintenance Manual (2014)

Quick Facts LED RECESSED LUMINAIRES

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Hazardous Area LED Lighting Champ FMV LED Luminaires. Champ FMV. LED floodlights for harsh and hazardous areas

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

Transcription:

WLL MOUNT INSTLLTION E477827 E477829 PPLICTION RS luminaires are designed for use in hazardous locations, indoors, outdoors, wet location, and areas containing moisture, dirt, corrosion, vibration, and rough usage. The RS luminaire has been certified for use on marine vessels inside, outside, and in other severely wet saltwater environments. s defined by the National Electrical Code (NEC) and the Canadian Electrical Code (CEC), they are suitable for use in the following areas: Certified to: UL 844, UL 1598, UL 1598, and UL 8750; CS 22.2 No. 137, CS 22.2 No. 250.0 and CS22.2 No. 250.13; S Listed Hazardous Location Zone pprovals: Class I, Division 2, Groups CD, T3; Class II, Division 2, Groups FG; Class III, T4 (Flood Models, T4 (Optical Models); Class I, Zone 2, Group IIC; Zone 22 Housing: Copper-free luminium with Polycarbonate lens Input Voltage: : 120-277 V : 347-480 V (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL MODEL RS10 RS15 RS20 RS25 RS30 INPUT VOLTGE RTED POWER 107 107 140 140 181 181 230 230 290 290 POWER (TYP) 104 104 136 136 176 176 223 223 281 281 @120V 0.86 1.13 1.46 1.86 2.40 @277V 0.38 0.49 0.63 0.81 1.02 @347 V 0.30 0.39 0.51 0.64 0.81 @480 V 0.22 0.28 0.37 0.46 0.59 OPTICL MODELS Connections: Temperature Range:: Ingress Protection: MODEL RS10 RS15 RS20 INPUT VOLTGE RTED POWER 109 109 175 175 225 225 POWER (TYP) 106 106 170 170 218 218 @120V 0.88 1.41 1.82 @277V 0.38 0.61 0.79 2 x 3/4 NPT Conduit lack: Line White: Neutral Green: Ground For connections use wire rated to a minimum of 90 C. Class 1 Wiring only. WF: -40 C to +55 C M, N, O, T2, T4: -40 C to +50 C IP66 Suitable For Wet Locations. Marine Outside Type (Salt Water) @347 V 0.30 0.49 0.63 @480 V 0.22 0.35 0.45 1-5

THIS LUMINIRE MUST E MOUNTED OR SUPPORTED INDEPENDENTLY OF N OUTLET OX. WLL MOUNT ONLY. To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accordance with all applicable electrical codes. The equipment is required to be installed with metallic conduit or other wiring method acceptable for specific hazardous locations per NEC and CEC. To avoid electric shock: e certain electrical power is OFF before and during installation and maintenance. Luminaire must be connected to a wiring system with an equipment-grounding conductor. POTENTIL ELECTROSTTIC CHRGING HZRD void electrostatic discharge : Clean Lens surface with damp cloth only To reduce the risk of ignition of hazardous atmospheres and to avoid electric shock, disconnect the luminaire from the supply circuit before opening for installation and servicing. Keep tightly closed when in operation. WLLPK INSTLLTION 1. Inspect shipping package and contents to ensure no damage has occurred during shipping. Step 2 2. Remove Wall racket from RS ox. 3. ssemble RS fixture ox to Head in desired configuration. *The main pivot bolt and arm to box fasteners are M6. **The angle adjustment bolts are M5. djustable in 15 increments Step 3 The RS Head must not face upwards by any degree beyond the vertical position for Class II, Division 2, and Zone 22 hazardous locations. LIGHT EM HORIZON 2-5

WLLPK INSTLLTION 4. Mount Wall racket to desired location. Step 4 *Ensure you use a minimum of two (2) 3/8 bolts to secure RS to wall surface. One in each of the upper and lower hole clusters. **Recommended to use four (4) in high wind and vibration environments. 1.5 38mm Step 5 4.3 111mm 5.9 150mm 5. Slide assembled fixture onto Wall racket. lign and mount lower four (4) M6 hardware first then proceed with top four (4) M6 bolts. djust Head angle if required. 6. Open RS ox lid. Step 6 7. Connect desired conduit/wire runs to the desired 3/4 NPT entry and run wire as per applicable standards for area of use. NOTE: To aid in assembly and protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant/sealant is necessary. 3-5

WLLPK INSTLLTION 8. Connect in feed to labeled wires in RS box as per applicable standards for area of use. For connections to existing terminals use solid or stranded conductors 18-12 WG rated for a minimum of 90ºC. Step 9 Connect each branch circuit conductor into appropriate connectors. For dimming, connect 18WG conductors to dimming connection points. - Use Violet (+) & Gray (-) for connection to 0-10vDC. - Wiring Violet & Gray together provides mininimum light output. - Capping Violet & Gray separately provides 100% light output. - 0-10V interface can be wired as Class 1 or Class 2 Circuit. - Driver will source a maximum of 200μ for control needs. - Controller must sink current from the 0-10V control leads. Note: Dimming controls must be certified and suitable for the classification of the area of their installation. See last page for Wiring Diagram. 9. Close RS ox lid. Torque lids screws according to diagram. 8 4 10 70 in lbs 2 9 6 CESSORIES Optional 2-3/8 Tenon Pole Mount can be attached directly to the RS ox. To be utilized with 2-3/8" OD minimum pole. Secure to Pole with supplied 3x3/8" Hex bolts and Jam nuts. Torque to 200 in-lbs (16.7 ft-lbs). Note: Wiring inside of the pole shall comply with the wiring methods acceptable for the specific Hazardous Location per the NEC and CEC and shall terminate in the threaded entry surrounded by the mount. If pole mount is used only for support of the luminaire ensure that the entry surrounded by the mount is plugged. To aid in assembly and protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant/- sealant is necessary. 7 1 3 5 10. Energize fixture. 4-5

WIRING DIGRM Depending on power level an RS Model may have 1 or 2 LED Drivers installed. Follow the appropriate wiring for your model of RS luminaire. Single Driver Model: LINE LK Factory Grounded Head and Power Supplies ranch Circuit Supply Wires NEUTRL WHITE PS GREEN GREEN/ (Factory) RS HED DIM (+) PURPLE Line In Ground to be terminated on Grounding Post of RS ox DIM (-) GREY Dual Driver Model: LINE Factory Grounded Head and Power Supplies LK ranch Circuit Supply Wires NEUTRL WHITE GREEN PS 1 GREEN/ (Factory) RS HED PS 2 DIM (+) PURPLE Line In Ground to be terminated on Grounding Post of RS ox DIM (-) GREY 5-5

HIGH Y INSTLLTION (SURFE) E477827 E477829 PPLICTION RS luminaires are designed for use in hazardous locations, indoors, outdoors, wet location, and areas containing moisture, dirt, corrosion, vibration, and rough usage. The RS luminaire has been certified for use on marine vessels inside, outside, and in other severely wet saltwater environments. s defined by the National Electrical Code (NEC) and the Canadian Electrical Code (CEC), they are suitable for use in the following areas: Certified to: CS 22.2 No. 137, CS 22.2 No. 250.0 and CS22.2 No. 250.13 ; UL 844, UL 1598, UL 1598, and UL 8750; S Listed Hazardous Location Zone pprovals: Class I, Division 2, Groups CD, T3C; Class II, Division 2, Groups FG; Class III, T4 (Flood models, T4 (Optical models); Class I, Zone 2, Group IIC; Zone 22 Housing: Copper-free luminium with Polycarbonate lens Input Voltage: : 120-277 V : 347-480 V (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL MODEL RS10 RS15 RS20 RS25 RS30 INPUT VOLTGE RTED POWER 107 107 140 140 181 181 230 230 290 290 POWER (TYP) 104 104 136 136 176 176 223 223 281 281 @120V 0.86 1.13 1.46 1.86 2.40 @277V 0.38 0.49 0.63 0.81 1.02 @347 V 0.30 0.39 0.51 0.64 0.81 @480 V 0.22 0.28 0.37 0.46 0.59 OPTICL MODELS MODEL RS10 RS15 RS20 INPUT VOLTGE RTED POWER 109 109 175 175 225 225 POWER (TYP) 106 106 170 170 218 218 @120V 0.88 1.41 1.82 @277V 0.38 0.61 0.79 @347 V 0.30 0.49 0.63 @480 V 0.22 0.35 0.45 Connections: Temperature Range: Ingress Protection: 2 x 3/4 NPT Conduit lack: Line White: Neutral Green: Ground For connections use wire rated to a minimum of 90 C. Class 1 Wiring only. WF: -40 C to +55 C N,M,O,T2: -40 C to +50 C IP66 Suitable For Wet Locations. Marine Outside Type (Salt Water) 1-5

THIS LUMINIRE MUST E MOUNTED OR SUPPORTED INDEPENDENTLY OF N OUTLET OX. To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accordance with all applicable electrical codes. The equipment is required to be installed with metallic conduit or other wiring method acceptable for specific hazardous locations per NEC and CEC. To avoid electric shock: e certain electrical power is OFF before and during installation and maintenance. Luminaire must be connected to a wiring system with an equipment-grounding conductor. POTENTIL ELECTROSTTIC CHRGING HZRD void electrostatic discharge : Clean Lens surface with damp cloth only To reduce the risk of ignition of hazardous atmospheres and to avoid electric shock, disconnect the luminaire from the supply circuit before opening for installation and servicing. Keep tightly closed when in operation. HIGH Y INSTLLTION (SURFE) 1. Inspect shipping package and contents to ensure no damage has occurred during shipping. Step 2 2. Remove Surface/Wall racket from RS ox. 3. Mount Wall racket to desired location with two (2) 3/8 bolts to secure RS to ceiling surface. Ensure placement of bolts in X pattern as shown by and 2.4 60mm Step 3 **Recommended to use four (4) in high wind and vibration environments. 3.2 81mm 1.8 46mm 2-5

HIGH Y INSTLLTION (SURFE) 4. Slide assembled fixture onto Surface/Wall racket. Step 4 5. lign and mount lower four (4) M6 hardware first then proceed with side four (4) M6 bolts. Step 5 6. If required, connect safety backup connection to High ay backup bracket. 7. Open RS ox lid. Step 6 8. Connect desired conduit/wire runs to the desired 3/4 NPT entry and run wire as per applicable standards for area of use. For connections use solid or stranded conductors 18-12 WG rated for a minimum of 90ºC. See last page for Wiring Diagram. Step 7 NOTE: To aid in assembly and protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant/sealant is necessary. 3-5

HIGH Y INSTLLTION (SURFE) 9. Connect in feed to labeled wires in RS box as per applicable standards for area of use. For connections to existing terminals use solid or stranded conductors 18-12 WG rated for a minimum of 90ºC. Connect each branch circuit conductor into appropriate connectors. For dimming, connect 18WG conductors to dimming connection points. - Use Violet (+) & Gray (-) for connection to 0-10vDC. - Wiring Violet & Gray together provides mininimum light output. - Capping Violet & Gray separately provides 100% light output. - 0-10V interface can be wired as Class 1 or Class 2 Circuit. - Driver will source a maximum of 200μ for control needs. - Controller must sink current from the 0-10V control leads. Note: Dimming controls must be certified and suitable for the classification of the area of their installation. Step 10 See last page for Wiring Diagram. 10. Close RS ox lid. Torque lids screws according to diagram. 8 4 2 6 10 70 in lbs 9 7 1 3 5 11. Energize fixture. 4-5

WIRING DIGRM Depending on power level an RS Model may have 1 or 2 LED Drivers installed. Follow the appropriate wiring for your model of RS luminaire. Single Driver Model: LINE LK Factory Grounded Head and Power Supplies ranch Circuit Supply Wires NEUTRL WHITE PS GREEN GREEN/ (Factory) RS HED DIM (+) PURPLE Line In Ground to be terminated on Grounding Post of RS ox DIM (-) GREY Dual Driver Model: LINE Factory Grounded Head and Power Supplies LK ranch Circuit Supply Wires NEUTRL WHITE GREEN PS 1 GREEN/ (Factory) RS HED PS 2 DIM (+) PURPLE Line In Ground to be terminated on Grounding Post of RS ox DIM (-) GREY 5-5