DEFROST CONTROLS PARAGON ERC-2 ELECTRONIC REFRIGERATION CONTROL

Similar documents
24HR 30A SPST TM SW. Features. Long Description

ET Basic+ Series Electronic Controls

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Electropneumatic Timing Relays Series 7000 Industrial

Product Specification Sheet #3LD2.1

Part # Features & Applications Specifications Cross Reference

7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction

A25 Series Warm Air Control with Manual Reset

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

C1000 Series Automatic Cap Bank

Special Specification 6058 Battery Back-Up System for Signal Cabinets

OTEC Transfer switch open transition

BAC Custom Engineered Controls

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

DIESEL Engine Fire Pump Controllers Features

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

TOTALINE PROTECTION CONTROLS

AccuPower AQU128B Installation Instructions

Transfer switch OTEC and OTECSE open transition

University of Houston Master Construction Specifications Insert Project Name

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

Heat Tracing Sales Mt. Airy, Maryland Controls

Enclosed Rotary Switch Product Specification Sheets Table of Contents

60T Series Snap-Action Temperature Controls

Locking-Type Mounting, Thermal Type K4500 Series

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Digital Time Switches

Central Battery Systems Loadstar AC/DC Systems

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

MiG2 TIME SWITCHES. 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches

VIBRATION SELECTION GUIDE

B BASIC HEAT TREATMENT CONSOLE

Transfer switch OTEC open or delayed transition

A22NK. Key-type Selector Switches

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

Surface mounting, flush mounting, and DIN track mounting

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

AccuPower AQU126B Installation Instructions

TOTALINE CAPACITORS RUN CAPACITORS OVAL MOTOR RUN CAPACITORS DUAL SINGLE

Remote Temperature Controllers. Quick Selection Guide

SPECIFICATION BULLETIN

CHP

24-hour/Weekly Time Switch H2F

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Multi-Pak Group Control

General Purpose Buck - Boost Wiring Diagrams... 86

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

3. Coils shall be of molded construction

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller

Design Standard. Purpose: Design Standard:

HUNTERSVILLE, NORTH CAROLINA USA. MAY Fax: Phone toll free:

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

40 Amp Resistive, VAC 40 Amp Tungsten, Inductive or 1000 VA Pilot Duty, VAC 2 HP (24 FLA) 120 VAC 5 HP (28 FLA) 240 VAC single-phase

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Class 9038 Type A Mechanical Alternator, Open Tank

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Uninterruptible Power Supplies

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

table of contents Switches J 1 SECTION SECTION J Quick Guide to Switches... J2-J3

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

LOCKNETICS Power Supplies. 510 Series Power Supply Controller 12 and 24 VDC. 505 Series Power Supply. 505DE Series Delayed Egress Controller

System 350 P352AB Electronic Pressure Control Series

RVS-DN Digital Reduced Voltage Motor Starter

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls. Instruction Sheet PA October 2007

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER

Series A DC Link Chokes

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures

BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS)

AquaMatic Series. A100 and A200 Stager Controls

IEC Limit Switches Selection Guide

JARD by MARS JARD by MARS

MERCURY CONTACTORS & RELAYS

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

TE-6300 Series Temperature Sensors

PISTON STYLE GAUGE. Mid-West Instrument

Definite Purpose Contactors Types DP, DPA, and SYD Class 8910

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel

Climate Control Products

IEC Limit Switches Selection Guide

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

Transcription:

DEFROST CONTROLS PARAGON ERC-2 ELECTRONIC REFRIGERATION CONTROL Real time clock for defrost control Integrated Control - Temperature Control Function - Defrost Control Function Output Relays [4] - Compressor - Defrost - Evaporator fan - Alarm Digital temperature display Keypad programming Two Temperature sensors [supplied] - Terminate defrost cycle - Refrigeration cycle Safe Mode Operation - Continues operation based on performance average in the event sensor fails Power Failure Recovery - All settings retained in memory - Time-of-day carried over for 100 hours NSF certified C-UR-us recognized component Rating equivalent to UL and CSA Voltage input 120/208/240VAC, 50 or 60 cycles P4396 P/N ERC-2-212111-170 ERC-2-222111-170 DESCRIPTION ERC-2 With NEMA 1 Case and Integrated Display ERC-2 With NEMA 1 Case and Remote Display 1090

DEFROST CONTROLS PARAGON COMMERCIAL DEFROST CONTROLS Special Features Time Initiated, Temperature or Pressure Terminated High amp switch contacts, 40 amps, 2 hp Positive slider bar switch designed, assures positive electrical contact and wipes the contact surface of contaminates Designed for defrost termination using an external temperature or pressure device Safety back-up mechanical time driven defrost termination Heavy duty synchronous design drive motor Choice of three contact arrangements Frequency of defrost initiation is adjustable from 1 to 6 cycles per day with a minimum of 4 hours between successive operations Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments Enclosed is constructed of heavy-duty steel with knockouts on the bottom, back and sides. Hasp and staple for padlock is part of the enclosure Models Time Initiated, Time Terminated High amp switch contacts, 40 amps, 2 hp Positive slider bar switch designed, assures positive electrical contact and wipes the contact surface of contaminates Choice of three contact arrangements Heavy duty synchronous design drive motor Frequency of defrost initiation is adjustable from 1 to 6 cycles per day with a minimum of 4 hours between successive operations Duration of the defrost cycle is adjustable from 4 to 110 minutes in 2 minute increments Accuracy of defrost duration is +/ - 2 minutes Enclosed is constructed of heavy-duty steel with knockouts on the bottom, back and sides. Hasp and staple for padlock is part of the enclosure Applications Defrost controls for commercial freezers and refrigerators P1170 P/N 120 VAC 208/240 VAC Time Initiated, Time Terminated Time Initiated, Temperature or Pressure Terminated 8041-00 8041-20 8045-00 8045-20 8047-00 8047-20 8141-00 8141-20 8143-00 8143-20 8145-00 8145-20 1091

TIMERS PARAGON ELECTRONIC TIME CONTROLS P1178 P1179 EC4000 EC1015 EC11 & EC11D EC7000 EC7005PC EC71 & EC71D EC4000 SERIES 24-HOUR OR 7-DAY The EC4000 Series are 24-hour, single-channel, electronic time controls that provide simple, inexpensive control of electrical loads with a time-of-day schedule. As a 24-hr. control, the same ON/OFF schedule is utilized each day. Saturday and/or Sunday, or any other day(s) of the week may be skipped. The skipped day(s) can be either load ON all day or load OFF all day, depending upon application. Sixteen events are available to provide programming versatility. An event defines an activity either load ON or load OFF. The EC4000 Series are available in either a NEMA 1 steel enclosure or a NEMA Type 3R non-metallic enclosure for indoor or outdoor use. 24-hr. programming with skip-a-day. Four-day min. power outage carry-over without the use of a battery. 20 amp ballast switch rating on DPST model (UL only). 16 ON or OFFs per day. SPST, SPDT and DPST switching. NEMA 1 or NEMA Type 3R enclosure. Large display & simple programming with just 4 keys. P1180 P1181 RATING PER POLE OF OUTPUT P1182 ENCLOSURE NEMA P1183 SHIPPING WGT. Lb Kg EC4000 Series - 24-hour, single-channel, capacitor carry-over EC4000/120V 20A SPDT 1 2 0.9 EC4000PC/120V 20A SPDT 3R 2-1/2 1.1 EC4000PC/120V-RT 20A SPDT 3R 2-1/2 1.1 EC4000/208-277V 20A SPDT 1 2 0.9 EC4000PC/208-277V PC/240V 30A SPDT 3R 2-1/2 1.1 EC4004/120V 30A SPST 1 2 0.9 EC4004/120V-RT 30A SPST 1 2 0.9 EC4004PC/120V 30A SPST 3R 2-1/2 1.1 EC4004PC/120V-RT 30A SPST 3R 2-1/2 1.1 EC4004/208-277V 30A SPST 1 2 0.9 EC4004/208-277V-RT 30A SPST 1 2 0.9 EC4004PC/208-277V 30A SPST 3R 2-1/2 1.1 EC4004PC/208-277V-RT 30A SPST 3R 2-1/2 1.1 EC4005PC/120, 208-240V 30A DPST 3R 2-1/2 1.1 EC4005PC/120, 208-240V-RT 30A DPST 3R 2-1/2 1.1 EC7000 SERIES 24-HOUR OR 7-DAY EC7000 Series are single-channel, electronic time controls that provide simple, inexpensive control of electrical loads with a time-of-day schedule. When schedules vary from day to day, the 7-day programming capability allows a different schedule for each day of the week. With 16 set points available, the EC7000 Series provides programming versatility. Models are also available to provide two individually programmable durations of one to 59 seconds in addition to the maintained ON & OFF set points. This provides ideal control for bell or chime ringing in schools & factories. The EC7000 Series Controls are ideal for indoor & outdoor lighting, billboard & security lighting, school crossing lights, heating, ventilating, bell, chime & buzzer ringing, water heater & security system control. 24-hr. or 7-day programming - 7-day programming allows greater flexibility thus added energy savings by allowing loads to remain on only when needed. 4-day min. power outage carry-over without the use of batteries. Eliminates the need to replace batteries & the environmental concerns of battery disposal 16 set points 30 amp heavy duty relay-output allows switching most electrical loads without the use of contractors. To-the-minute programming with just four keys & a large easy to read display that uses visual prompts for ease of programming. SPST, SPDT, DPST switching designed for high immunity to electrical noise Momentary feature available. Recessed reset button Available in NEMA Type 3R (EC7005) or NEMA 1 enclosures. NOTE: Also available in 50 amp. Contact your nearest branch for details and other available models. RATING PER POLE OF OUTPUT ENCLOSURE NEMA SHIPPING WGT. Lb Kg EC7000 Series - 24-hour and 7-day, single-channel, capacitor carry-over EC7000/24V 20A SPDT 1 2 0.9 EC7000/120V 20A SPDT 1 2 0.9 EC7000PC/120V-RT 20A SPDT 3R 2 0.9 EC7000/208-277V 20A SPDT 1 2 0.9 EC7001PC/12VDC 10A SPDT 3R 1-1/2 0.7 EC7001/24V 20A SPDT 1 2 0.9 EC7001/120V 20A SPDT 1 2 0.9 EC7001/208-277V 20A SPDT 1 2 0.9 EC7004/120V 30A SPST 1 2 0.9 EC7004/208-277V 30A SPST 1 2 0.9 EC7005PC/120V, 208-240V 30A DPST 3R 2 0.9 EC7005PC/277V 30A DPST 3R 2 0.9 EC71/18S Series - 365-day, single channel EC71/18S/120V 15A SPDT 1 2 0.9 EC71D/18S/24V 15A SPDT DIN 1-1/8 0.5 EC71D/18S/120V 15A SPDT DIN 1-1/8 0.5 EC71D/18S/240V 10A SPDT DIN 1-1/8 0.5 1092

PARAGON 24-HOUR TIME SWITCHES 4000 & 4000S SERIES 24-HOUR The 4000 series has a 24-hour dial with 2 to 14 replaceable trippers for 1 to 7 On and Off operations per day. The 4000-S series is the same as the 4000 series but with Skip-A-Day feature to allow skipping operations on any day or days of the week without disturbing the preset schedule. 1/2 hour min. On or Off time; 22-1/2 hour max. On or Off time. Manual On/Off lever transfers switch operation without disturbing preset schedule. Switch slider bar assures positive switching. Heavy duty terminals accommodate up to AWG #8 wire. NEMA type 1 indoor case with combination 1/2-3/4 in. knockouts in bottom and sides; hasp for padlock or seal. 4000 SERIES 4010 SERIES P1203 P1204 TIMERS 4000, 4010 AND 4210 SERIES 1-1/2 Hour Minimum On or Off Time, 1 to 7 On/Off Operations Per Day ENCLOSURE SHIPPING SWITCH HP AC LINE WGT. VOLTS NEMA Lb Kg. 4000 Series - Standard NEMA 1 indoor metal enclosure 4001-00 SPST 1 120 1 2-1/2 1.1 4001-00-RT SPST 1 120 1 2-1/2 1.1 4001-00B SPST 1 120-2-1/2 1.1 4001-00M SPST 1 120-1-1/8 0.5 4002-71 SPST 1 208-277 1 2-1/2 1.1 4002-71B SPST 1 208-277 - 2-1/2 1.1 4003-00 DPST 1 120 1 2-1/2 1.1 4003-00-RT DPST 1 208-277 1 2-1/2 1.1 4003-00M DPST 1 208-277 - 1-1/8 0.5 4004-71 DPST 1 208-277 - 2-1/2 1.1 4004-71-RT DPST 1 208-277 - 2-1/2 1.1 4004-71B DPST 1 208-277 1 2-1/2 1.1 4004-71M DPST 1 208-277 - 1-1/8 0.5 4005-00B SPDT 1 120-2-1/2 1.1 With skip-a-day, allows schedule to be omitted on any day(s) without permanently disturbing preset schedule 4003-00S DPST 1 120 1 2-1/2 1.1 4003-00SB DPST 1 120-2-1/2 1.1 4003-00SM DPST 1 120-1-1/8 0.5 4004-06S DPST - 24 1 2-1/2 1.1 4004-21S DPST 1 208-277 1 2-1/2 1.1 4005-00S SPDT 1 120 1 2-1/2 1.1 4005-00SB SPDT 1 120-2-1/2 1.1 4006-71S SPDT 1 208-277 1 2-1/2 1.1 4007-06S SPDT - 24 1 3-1/2 1.6 4007-06SB SPDT - 24-2 1.1 With skip-a-day and astro dial, adjusts for seasonal changes in sunrise and sunset times 4003-00SZ32 DPST 1 120 1 3 1.4 4003-00SZ42 DPST 1 120 1 3 1.4 4004-71SZ32 DPST 1 208-277 1 3 1.4 4004-71SZ42 DPST 1 208-277 1 3 1.4 4005-00SZ32 SPDT 1 120 1 3 1.4 4005-00SZ42 SPDT 1 120 1 3 1.4 4006-71SZ32 SPDT 1 208-277 1 3 1.4 4006-71SZ42 SPDT 1 208-277 1 3 1.4 Leaves load on during day(s) scheduled to be skipped 4008-20S DPST 1 208-240 1 2-1/2 1.1 4010 Series - Standard NEMA 3 indoor/outdoor metal or NEMA type 3R plastic enclosure 4011-00 SPST 1 120 3 4-3/4 2.2 4011-00P SPST 1 120 3R 1-3/8 0.6 4011-00PC-RT SPST 1 120 3R 1-3/8 0.6 4013-00 DPST 1 120 3 4-3/4 2.2 4013-00P DPST 1 120 3R 1-3/8 0.6 4013-00PC-RT DPST 1 120 3R 1-3/8 0.6 4014-71 DPST 2 208-277 3 4-3/4 2.2 4014-71P DPST 2 208/277 3R 1-3/8 0.6 4014-71PC-RT DPST 2 208/277 3R 1-3/8 0.6 With skip-a-day, allows schedule to be omitted on any day(s) without permanently disturbing preset schedule 4013-00S DPST 1 120 3 4-3/4 2.2 4014-71S DPST 1 208-277 3 4-3/4 2.2 With skip-a-day and astro dial, adjusts for seasonal changes in sunrise and sunset times 4013-00SZ32 DPST 1 120 3 5-1/2 2.5 4013-00SZ42 DPST 1 120 3 5-1/2 2.5 P1205 4210 SERIES 1093

TIMERS PARAGON 7-DAY TIME SWITCHES 7000 SERIES 7-day calendar permits different On/Off schedules on different days of the week. Maximum of 4 On/Off operations per day and 28 per week. 3 hour min. On or Off time per day; 21 hour max. On or Off time per day. Independent 4-pole design allows for SPST, DPST or SPDT switching. Manual overrride lever temporarily reverses switch operation without permanently disturbing preset schedule. Switch slider bar assures positive switching Heavy duty industrial type synchronous motor. Heavy duty terminals accommodate up to AWG #8 wire. Standard NEMA 1 indoor metal enclosure side hinged with combination 1/2-3/4 in. knockouts in bottom and side. Hasp for padlock or seal. 7210 SERIES 7-day calendar permits different On/Off schedules on different days of the week. Maximum of 4 On/Off operations per day and 28 per week. 3 hour min. On or Off time per day; 21 hour max. On or Off time per day. Independent 4-pole design allows for SPST, DPST or SPDT switching. Manual overrride lever temporarily reverses switch operation without permanently disturbing preset schedule. Switch slider bar assures positive switching Heavy duty industrial type synchronous motor. Heavy duty terminals accommodate up to AWG #8 wire. Standard NEMA 3 indoor/outdoor metal enclosure side hinged with combination 1/2-3/4 in. knockouts in bottom and sides. Hasp for padlock or seal. Spring wound carry-over to take over during power outages, keeping control running up to 10 hours. Only two hour wind up required for each hour of power outage. 7000 and 7210 SERIES 4-Pole, 3 Hour Minimum On or Off Time, 4 On/Off Operations per Day, 28 per Week P1177 AC LINE ENC. SWITCH SWITCH RATING PER POLE SHIPPING WGT. 60 HZ AMP AMP T VA HP VOLTS NEMA Lb Kg 7000 Series 7007-00 4PST-4 NO 40 40 690-120 1 6-1/2 2.9 * 7007-06 4PST-4 NO 40-345 - 24 1 6-1/2 2.9 7007-71 4PST-4 NO 40 40 690-208-277 1 6-1/2 2.9 7008-00 2 NO-2 NC 40-690 1 120 1 6-1/2 2.9 7008-00B 2 NO-2 NC 40-690 1 120-6-1/2 2.9 * 7008-06 2 NO-2 NC 40-345 - 24 1 6-1/2 2.9 7008-71 2 NO-2 NC 40-690 1 208-277 1 6-1/2 2.9 7210 Series - With spring wound carry-over 7217-00 4PST-4 NO 40 40 690-120 3 10 4.5 7217-20 4PST-4 NO 40 40 690-208-240 3 10 4.5 *Not UL or CSA listed. Hp rating one pole only. Furnished with 7 sets of on/off trippers. Switch rating per pole = 40 amp. Hertz = 60. 1094

REFRIGERATION DEFROST CONTROLS PARAGON COMMERCIAL REFRIGERATION DEFROST CONTROLS 8040 SERIES Frequency of defrost initiation is adjustable from 1-6 cycles per day. Min of 4 hours between successive operations. Duration of defrost cycle is adjustable from 4-110 minutes in 2 minute increments. Accuracy of defrost duration ± 2 minutes. Choice of 4 contact arrangements for electric heat, hot gas or compressor shutdown defrost. Positive switch action slider bar. Heavy duty synchronous motor. Heavy steel enclosure. Grey finish. Knockouts on bottom, back and sides. Hasp and staple for padlock. Available on bracket for sub-panel mounting. 8140 SERIES Frequency of defrost is 1-6 cycles per day. Min of 4 hours between successive defrost cycles. Adjustable back-up defrost termination from 4-110 minutes in 2 minute increments. Control works with an external temperature or pressure sensor. Choice of 3 contact arrangements for electric heat, compressor shutdown defrost or hot gas defrost. Positive switch action slider bar. Heavy duty synchronous industrial type motor. Heavy steel enclosure. Grey finish. Knockouts on bottom, back and sides. Hasp and staple for padlock. Available on bracket for sub-panel mounting. 8040 SERIES Time Initiated, Time Terminated, 40 Amp P1170 8040 & 8140 SERIES AC LINE SWITCH ARRANGEMENT ADJ. LENGTH 60 HZ CONTACTS OF DEFROST VOLTS 2-4 1-3 3-N 8041-00 120 Closed Open Closed 4-110 Min. 8041-20 208-240 Closed Open Closed 4-110 Min. 8045-00 120 Closed Open None 4-110 Min. 8041-20 208-240 Closed Open None 4-110 Min. 8047-00 120 Open Open Closed 4-110 Min. 8047-20 208-240 Open Open Closed 4-110 Min. NEMA 1 indoor metal enclosure. 8140 SERIES Time Initiated, Remote Temperature or Pressure Terminated, 40 Amp NORMAL POSITION OF CONTACTS AC LINE DURING REFRIGERATION CYCLE 60 HZ CONTACT CONTACT CONTACT VOLTS N-3 1-3 2-4 NEMA 1 indoor metal enclosure 8141-00 120 Closed Open Closed 8141-20 208-240 Closed Open Closed 8143-00 120 Open Closed Open 8143-20 208-240 Open Closed Open 8145-00 120 None Open Closed 8145-20 208-240 None Open Closed NEMA 1 indoor metal enclosure. 1095

REFRIGERATION DEFROST CONTROLS PARAGON COMMERCIAL REFRIGERATION DEFROST CONTROLS 8240 SERIES Frequency of defrost is 1-6 cycles per day. Min. of 4 hours between successive defrost cycles. Adjustable back-up defrost termination from 4-110 minutes in 2 minute increments. Choice of 3 contact arrangements for electric heat, compressor shutdown defrost or hot gas defrost. Positive switch action slider bar. Heavy duty synchronous industrial type motor. Heavy steel enclosure. Grey finish. Knockouts on top. Available on bracket for sub-panel mounting. P1202 8240 SERIES 8240 SERIES Time Initiated, Pressure Terminated, 40 Amp NORMAL POSITION OF CONTACTS AC LINE UPC NO. DURING REFRIGERATION CYCLE 60 HZ 79046 CONTACT CONTACT CONTACT VOLTS N-3 1-3 2-4 8245-00 00580 120 Closed Open None 8245-20 00590 208-240 Closed Open None 8247-20 00610 208-240 Open Open Closed NEMA 1 indoor metal enclosure. 1096

REFRIGERATION DEFROST CONTROLS/ACCESSORIES PARAGON ACCESSORIES DIAL TRIPPERS, PINS AND BATTERIES PART NUMBER USE WITH SERIES QUANTITY PER SET X2772 4000 4210 47017 4010 47217 1ON,1OFF X3495 4000-S 4210-S 47017-S 4000-SZ 4210-SZ 47017-SZ 6 cutout pins X3596 8025þ 8140* 8040* 8240* 5 trippers X4296 4000-S 47017-S 4210-S 47217-S Cutout index tripper (ON) X4299 7000 7210 1 ON, 1 OFF X7248 RM* 12 X8348 4008-S 1 ON, 1 OFF X9242 P100 1 ON, 1 OFF X9246 P100-S Cutout pins (6) X9249 4008-S Cutout Index tripper (OFF) X9250 P100-S Cutout Index tripper (ON) *See Bulletin #3010. P1184 P1185 P1186 P1187 P1188 P1189 P1190 P1191 X2772 X3495 X3596 X4296 X4299 X8348 X9242 X9246 X9249 X9250 Brackets For Panel Mounting PART SHIPPING WGT. USE WITH SERIES NOTES NUMBER LB KG A454-W (X2626) 8025 8040 8140 1-1/2 0.7 A536 (X4105) A537-W (X3967) A569 (X5815) D874-99 Intermatic Adapter Bracket A1408-99* *Must be used with 4010PC. 4000 4000-S 4000-SZ 4010 4010-S 4010-SZ 41010 EC4000 P100 EC7000 not for carry-over models 1-1/2 0.7 623 42010 1015-40TS 1015 not for carry-over models 1-1/2 0.7 47017 7000 47217 7010 7210 may be used with carry-over models 1-1/2 0.7 4000 4010-S EC4000 4000-S P100 EC7000 not for carry-over models 3 oz. 0.1 4010 EC4000 4010PC EC7001 EC4004 EC7000 EC7004 3 oz. 0.1 P1192 P1193 P1194 P1195 P1196 P1197 A454 (X2626) A569 (X5815) A536 (X4105) D874-99 A537 (X3967) A1408-99 1097