Probabilistic Risk Assessment for Spent Fuel Pool Decommissioning in the J. Bohunice V1 NPP

Similar documents
AP1000 European 7. Instrumentation and Controls Design Control Document

Operational risks of old nuclear power plants in Switzerland

ANALYSIS OF BREST-OD-300 SAFETY DURING ANTICIPATED OPERATIONAL OCCURRENCES

AP1000 Plant Overview

DRAFT SONGS Units 2 and 3 Irradiated Fuel Management Plan

Seismic Damage Information (the 120th Release) (As of 15:00 April 29, 2011)

CC System B B 3.7 PLANT SYSTEMS. B Component Cooling Water (CC) System BASES

S. Y. Park (*), K. I. Ahn

By: Eugenijus Uspuras Algirdas Kaliatka Sigitas Rimkevicius ASME 2012 Verification & Validation Symposium May 2-4, 2012, Las Vegas, NV

A Tool for planning the Safety Review of SSCs: Development and Application

The IAEA does not normally maintain stocks of reports in this series.

Nuclear L.L. C. 10 CFR 50.55a

ams.t.andard REVIEW PLAN.

Fuel Management in EWN

Reactor Safety /22.903

TEPCO NUCLEAR SAFETY REFORM PLAN PROGRESS REPORT 1 ST QUARTER FY 2014 EXECUTIVE SUMMARY

REGULATORY CONTROL OF NUCLEAR FUEL AND CONTROL RODS

Current and Prospective Tests in Reactor MIR.M1

PIPE WHIP RESTRAINTS - PROTECTION FOR SAFETY RELATED EQUIPMENT OF WWER NUCLEAR POWER PLANTS

1: CANDU Reactor. B. Rouben McMaster University Nuclear Reactor Physics EP 4D03/6D Sept-Dec September 1

Bohunice V-2 power plant mixed core licensing and operation experiences Ondrej Grežďo

THE FUKUSHIMA ACCIDENT: CAUSES, RESULTS AND IMPLICATIONS FOR EUROPE

Seismic Damage Information (the 144th Release) (As of 15:00 May 20, 2011)

Evaluation of sealing performance of metal. CRIEPI (Central Research Institute of Electric Power Industry)

AP Plant Operational Transient Analysis

April 23, U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC

Current Status of Fukushima Daiichi Nuclear Power Station & Lessons Learned from Experiences of the Great East Japan

Fukushima Daiichi Accident Technical Causal Factor Analysis

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS

Refuelling error at Dampierre unit 4 02/04/2001 Lessons learned. EDF th and 14 th 2003 Expert Meeting KTG - error on Dampierre unit 4

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

GE ABWR & ESBWR. Jeff Suggs ESBWR I&C April 17, Copyright 2006 by GE Energy / Nuclear

LECTURE 12 MAINTENANCE: BASIC CONCEPTS

Safety Standards. of the Nuclear Safety Standards Commission (KTA) General Requirements for the Electrical Power Supply in Nuclear Power Plants

AP1000 European 5. Reactor Coolant System and Connected Systems Design Control Document

A.L. Izhutov, A.V. Burukin, Current and prospective fuel test programmes in the MIR reactor

WELCOME AND INTRODUCTORY REMARKS

Verifiably, Irreversibly Halting Operations at Yongbyon. David Albright, ISIS January 14, 2004

AP1000 Nuclear Power Plant Squib Valve Design Challenges & Regulatory Interface. September 2017

Rosatom Seminar on Russian Nuclear Energy Technologies and Solutions

American Traction Systems

Beyond Design Basis Analysis:

EXTENDED STUDY OF COOLABILITY OF VVER BUNDLE WITH BALLOONED REGION

The role of CVR in the fuel inspection at Temelín NPP

SUB-CHAPTER B.3 COMPARISON TABLE COMPARISON WITH REACTORS OF SIMILAR DESIGN (N4 AND KONVOI)

Improvements in EPR arrangements in Slovenia

Key-Words : Eddy Current Testing, Garter Spring, Coolant Channels, Eddy Current Test Coil Design etc.

Toll Free 1(800)

Fuel removal from the spent fuel pool at Fukushima Daiichi Nuclear Power Station Unit 3

*TATSUYA KUNISHI, HITOSHI MUTA, KEN MURAMATSU AND YUKI KAMEKO TOKYO CITY UNIVERSITY GRADUATE SCHOOL

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER C: DESIGN BASIS AND GENERAL LAYOUT 4. CONTROL-ROD DRIVE MECHANISM

Single-phase Coolant Flow and Heat Transfer

Aoý. 0Constellation Nuclear. Calvert Cliffs Nuclear Power Plant. February 27, U. S. Nuclear Regulatory Commission Washington, DC 20555

ExxonMobil SYU LFC Interim Trucking Industrial Risk Analysis

Event sequences Fukushima

POWER RAMPING AND CYCLING TESTING OF VVER FUEL RODS IN THE MIR REACTOR

Current Status of the Melcor Nodalization for Atucha I Nuclear Power Plant. Zárate. S.M. and Valle Cepero, R.

Radiation protection aspects of a fuel handling incident at Forsmark NPP 2013

Methods of brake efficiency evaluation for heavy duty vehicles in Slovakia

An Application of the Fault Tree Analysis for the Power System Reliability Estimation

Case Study: Silver Lining in Plants Oil Analysis Program Prevents Catastrophic Generator Failure

WM2012 Conference, February 26 March 1, 2012, Phoenix, Arizona, USA. Treatment of Uranium Slugs at the CEA Marcoule site 12026

TREAT Startup Update

FRM II Converter Facility

STANDARD REVIEW PLAN

74 ow. 10 CFR 50.46(a)(3)(ii)

JAMES F. GLEASON, P.E. CHAIRMAN QUALIFICATION COMMITTEE

Impact of the Niigata Chuestu-oki Earthquake on the Tokyo Electric Power Company (TEPCO) Kashiwazaki-Kariwa Nuclear Power Station and Countermeasures

Duke Power Company DOCUMENT TRANSMITTAL FORM REFERENCE MCGUIRE NUCLEAR STATION SELECTED LICENSEE COMMITMENTS MANUAL. Page 2 of 3

The Establishment and Application of TRACE/FRAPTRAN Model for Kuosheng Nuclear Power Plant

Updated information of Fukushima Daiichi NPP. October Ki Sig Kang 1

IMPLEMENTATION OF THE RCP SHIELD MECHANICAL SEAL MODEL IN THE COMANCHE PEAK PRA

PUBLIC SERVICE COMMISSION OF WEST VIRGINIA %% CHARLESTON

Next Phase of Fukushima Daiichi D&D (Enhanced institutional and technical efforts by Team Japan )

5.0 REACTOR COOLANT SYSTEM AND CONNECTED SYSTEMS

Primary Heat Transport (PHT) Motor Rotor Retaining Ring Failure

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

AS Augstsprieguma tikls the part of integrated Baltic and European power system

Journal of Engineering Sciences and Innovation Volume 2, Issue 4 / 2017, pp

CONSIDERATIONS REGARDING THE HORIZONTAL FUEL CHANNELS IN THE CANDU 6 NUCLEAR REACTOR. PART 1 - PRESENTATION OF THE FUEL CHANNEL

DEVELOPMENT OF A 3D MODEL OF TUBE BUNDLE OF VVER REACTOR STEAM GENERATOR

Health Monitoring of Rotating Equipment from Torsional Vibration Features

PROF. UNIV. EMERIT DR. ING.

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

Fukushima Daiichi NPP. May , Ki Sig Kang

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER D: REACTOR AND CORE

FBR and ATR fuel developments in JNC

Seabrook Substation Reliability Improvement Project

The Swedish Government Inquiry on Smart Grids

Hope Creek Variable Frequency Drive

Fukushima Accident and Safety Assurance Measures for TEPCO NPP

ExxonMobil SYU LFC Interim Trucking Industrial Risk Analysis

Profile SFR-77 METL USA. LOCATION (address): Bldg. 308 / 9700 South Cass Avenue / Lemont, IL / USA

NEW TYPES OF NUCLEAR FUEL D. Krylov JSC TVEL

SUB-CHAPTER E.4 DESIGN OF COMPONENTS AND SUB-SYSTEMS

Part 1 What Do I Want/Need in a Vehicle?

Super-Critical Water-cooled Reactors

HAZARDOUS AREA. Multi ac THE VERY BEST IN HAZARDOUS AREA VACUUM RECOVERY SYSTEMS INNOVATION THROUGH EXPERIENCE.

Case Study: Silver Lining in Plants Oil Analysis Program Prevents Catastrophic Generator Failure

Requirements and rationale for the acceptance of petrol filling stations located under residential, hotels or commercial property

Transcription:

Probabilistic Risk Assessment for Spent Fuel Pool Decommissioning in the J. Bohunice V1 NPP by Zoltán Kovács, Robert Spenlinger and Helena Novakova RELKO Ltd, Engineering and Consulting Services Račianska 75, P.O.Box 95, 830 08 Bratislava, Slovak Republic Email: kovacs@relko,sk, www.relko.sk 1/20

Contents Introduction The spent fuel pool The risk assessment The results Conclusions 2/20

Introduction The first working nuclear power plant in Slovak Republic is situated near the village of J. Bohunice in West Slovakia. The plant consists of four reactor units. The first two units (the J. Bohunice V1 plant) are equipped with Russian WWER440/230 type reactor which was designed in the early 1960s. After decision of the Slovak government the V1 plant will be permanently shutdown in the end of 2008. 3/20

V1 V2 4/20

Introduction The time schedule for termination of the J. Bohunice V1 plant operation has two phases. In the first phase from the beginning of 2007 to the end of 2008 the reactor of the Unit 1 is shutdown and its operation is terminated. The Unit 2 is in power operation or shutdown modes for refuelling outage. The second phase is the time period after 2008. Both units will be shutdown; the operation of the second unit will be also terminated. 5/20

Introduction After the permanent shutdown of the unit 1 in December 2006, immediate fuel unloading and fuel transportation to the spent fuel pool (SFP) was planned. A study was prepared to evaluate of SFP accident risk at the decommissioning plant. The study was undertaken to develop a risk-informed technical basis for the Slovak Nuclear Regulatory Authority. The main results of the study are summarized in this paper. 6/20

The spent fuel pool BA20A-4 BA20A-18 BA12A-3 BA11A-3 BO10N-1 TVD BA12T-1 TVD BA11T-1 BA12A-2 BA11A-2 BA12Č-1 BA11Č-1 HD10N-1 BA12A-1 BA11A-1 BA20A-01 BA20A-3 BA20A-3 BA20A-2 BA20Č-1 BA20A-1 7/20

The spent fuel pool The spent fuel pool cooling system is consisting of motor-driven pumps, heat exchangers, the ultimate heat sink, a makeup tank, and isolation valves. Coolant is drawn from the SFP by one of the two pumps, passed through the heat exchanger, and returned to the pool. The essential service water system is used on the secondary side of the heat exchanger for heat removal. A filtration system is connected to the spent fuel pool. Small amount of water is diverted to the filtration process and is returned into the discharge line within a selected time periods. During loss of the SFPC system or loss of pool inventory, inventory can be made up using the HD10N-1 tank. In addition, several other water sources are available to compensate losses from the SFP (CD system, RB system, HD60N-1 tank and mobile water source). The analysis takes into account all water sources. 8/20

The spent fuel pool The fuel can be stored in two levels in the pool. During normal plant operation the second level is used only in operating mode 7, when there is check of the reactor vessel and all fuels are located to the spent fuel pool (once per 4 years for several hours). The delivery line of the SFPC system is ended at the level of -1.7 m and it is protected against siphoning effect. The suction line is ended at the level of +4.5 m. It is not protected against siphoning effect. Given a piping rupture in the suction line of SFPC system, the fuel stored in the second level can be uncovered due to the siphoning effect. There is a weak point in the design. The single failure criterion is not met for the case when the fuel is stored in two levels. After termination of the Unit 1 operation a solution was needed for this problem. 9/20

The spent fuel pool delivery line suction line water level for storage in two levels protection against siphoning effect +10.5m +8.4m 73.54 m 3 +6.3m 73.54 m 3 water level for storage in one level +5.0m +4.5m 28.01 m 3 5.91 m 3 3.94 m +5.2m 3 +5.47m spent fuel 69.00 m 3 +2.5m +1.5m 56 m 3 spent fuel 65.06 m 3-1.0m -1.7m -1.8m 10/20

The risk assessment The probabilistic safety analysis of the SFP was performed for the following scenarios: 1. the suction line is modified so, that the suction is on the level of +8.4 m, the fuel is stored in both levels, the water level is on +10.5 m (this solution allows to meet the single failure criterion for the SFP), 2. the suction line is not modified, the suction is on the level of +4.5 m, the fuel is stored in both levels, the water level is on +10.5 m (the fuel is uncovered given a piping rupture in the suction line), 3. the suction line is not modified, the suction is on the level of + 4.5 m, the fuel is stored only in one level, the water level is on +5.2 m (the fuel is not uncovered given a piping rupture in the suction line), 4. the suction line is not modified, the suction is on the level of + 4.5 m, the fuel is stored only in one level, the water level is on +10.5 m (the fuel is not uncovered given a piping rupture in the suction line). 11/20

The risk assesment The following initiating events are identified for the SFP: loss of cooling, loss of coolant, loss of offsite power, internal fires, extreme meteorological conditions, impact of neighbouring industry, heavy load drop, aircraft crash, seismic event. 12/20

Loss of cooling Time to fuel uncovery scenario 1 and 2 Decay time [day] Decay heat [kw] 10 3 384 37 15 2 855 45 20 2 525 49 50 1 636 76 100 1 123 111 365 428 292 730 233 536 1 095 154 813 Time to fuel uncovery [h] 13/20

Loss of coolant Break No. Scenario Time to fuel uncovery 1 1 24 h 10 min 2 24 h 12 min 3 25 h 17 min 4 24 h 29 min 1 2 16 min 2 20 min 3 11 h 4 67 min 1 3 12 h 49 min 2 12 h 48 min 3 15 h 46 min 1 4 13 h 6 min 2 13 h 8 min 3 26 h 4 min 4 13 h 56 min 14/20

Internal fire Loss of SFP cooling caused by internal fires. Fire in the room V110/1 leads to this event. There is automatic fire detection but no automatic fire suppression for the SFP cooling area. Manual fire suppression is needed. Recovery times are the same as for loss of cooling. 15/20

Other IE The other initiating events: extreme meteorological conditions, impact of neighbouring industry, heavy load drop, aircraft crash and seismic event were screened out from the analysis due to negligible impact on the risk. 16/20

The results The fuel damage frequency was calculated for the different scenarios: scenario 1: 2.55E-8/y scenario 2: 3.73E-5/y scenario 3: 3.27E-8/y scenario 4: 2.62E-8/y 17/20

The results The large early release frequency is the same as the fuel damage frequency because the SFP is located outside the confinement. In case of scenario 1 the most dominant initiating event is the loss of cooling, (54.9%), then loss of coolant (22.5%), loss of offsite power (18.1%) and fire in the room V110/1 (4.5%). The highest risk is in scenario 2 with dominant contribution from loss of coolant (99.99%). The contribution to the risk in case of scenario 3 is the following: loss of cooling (42.8%), loss of coolant (34.9%), loss of offsite power (18.7%) and fire in the room V110/1 (3.6%). The contribution to the risk in case of scenario 4 is the following: loss of cooling (53.4%), loss of coolant (24.9%), loss of offsite power (17.4%) and fire in the room V110/1 (4.3%). 18/20

The results The results of the study indicate that the risk at SFP is low when the fuel is located only in one level (scenario 3 and 4). If the fuel storage is in two levels, the risk is high (scenario 2). In scenario 1 modification of the design is needed (modification of suction line) to achieve low risk with the fuel located in two levels. The risk is highest in scenario 2. Given piping break of the suction line, fuel uncovery can occur within 16 minutes. In addition, the single failure criterion is not met. 19/20

Conclusions After termination of the Unit 1 operation the fuel would be located in two levels because the SFP is not empty. Fuel from the former campaigns is located there. However, the results of risk assessment have shown us that the risk of fuel storage in two levels is high. Design modification of the spent fuel pool is needed. Alternative solution for this problem is to leave the fuel in the reactor vessel for a limited time period and to remove the residual heat in operating mode 5. Probabilistic safety analysis was performed also for this solution and the conclusion was to have the fuel located in the reactor vessel for the time period of one year. Then, the SFP will be empty and the fuel from the reactor vessel can be stored in one level. 20/20