IMPORTANT: SAFETY INSTRUCTIONS

Similar documents
IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

UNPACKING THE UNIT. Alcohol cleaning pad

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

WARRANTY. Air flow. (Please note standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.

INSTALLATION TEMPLATE

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

UV-AIRE AIR PURIFYING SYSTEM

HARDWARE KIT INSTALLATION GLOVES

BIO-FIGHTER 4Xtreme 21", 33", 45" Ultraviolet Light Systems

Installation Instructions

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

Safety, Installation and Service Manual Models 1952, 1953 & 1972

Installer s Manual. PCO/UV N-Duct Model

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

INSTALLATION, MAINTENANCE & OPERATION GUIDE. MODEL Sanuvair S300 WHOLE HOUSE HEPA/UV AIR PURIFIER. ITEM # Sanuvair S V EN

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems

Ultraviolet Systems RXIU-A02A, RXIU-A03A TREATMENT SYSTEMS

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

Air Purification Unit. Operation and Maintenance Manual

Installation Instructions

Air Purification Unit. Operation and Maintenance Manual

UV100A Ultraviolet Systems UV100A1000 AND UV100A1018 AIR TREATMENT SYSTEMS UV100A1059 AND UV100A2008 SURFACE TREATMENT SYSTEMS

Installation & Maintenance of the Fresh-Aire UV Tubular Rack System for Commercial Air Handler Systems

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

CAUTION: Read manual carefully for proper procedures and operation.

UV-AIRE AIR PURIFYING SYSTEM

INSTALLATION GUIDE. Greentek. Residential use only MODEL HS 3.0

PHOTO-CATALYTIC AIR PURIFIER SYSTEMS

21", 33", 45", & 61" Installation & Operation Manual

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

INSTALLATION / OPERATION / MAINTENANCE GUIDE

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System For PTAC & ETAC Units

INSTALLATION INSTRUCTIONS

Specification Grade Contemporary Wall Mount/Technical Installation Data

Captivate Illuminated Mirror Light

COILCARE PM. Installation Instructions and Operating Manual. CoilCare Series BioZone Scientific International, Inc.

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

FOURNISSEUR : CE MANUEL DOIT ÊTRE REMIS À L UTILISATEUR DE CE PRODUIT.

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

IsoLED FLEX I CUSTOMER MANUAL

Cincinnati, OH USA

MINISTICK TM UV Germicidal Ultraviolet Light

READ AND SAVE THESE INSTRUCTIONS FOR THE DUCTSTAT TEMPERATURE SENSITIVE SWITCH

MCI. SynAIRgPURE. Owner s Manual

1600PAC. HEPA Air Filtration Machine. Operation and Maintenance Manual

WARNING Risk of property damage, injury, or death.

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

Cable Cubby 650 UT Installation Guide

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

For Mini Split Units. Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Have a bright day! Nicholas Harmon President, Verilux, Inc.

Further information: Berriman Associates Model 850P.2 Owners Manual

INSTRUCTION BOOK FOR. Dual Masking Electrol

OCTA FLUORESCENT 7 SOCKET FIXTURE

TOSHIBA Thermal Printer B-SX6T/SX8T SERIES. Maintenance Manual. Document No. EO Original Mar., 2006 (Revised ) PRINTED IN JAPAN

Owner s Manual Hydro-X Xtreme Xtractor

xtablet T7000 Vehicle Mount Kit

LED DayLite WireLess Mini

Vehicle Rear Observation System With Integrated Parking Sensors

TRAILER WINCH MODELS ST315 AND ST712. General Safety (Continued) Description. Unpacking. General Safety Information.

Troubleshooting Guide

INSTRUCTION BOOK FOR. Tensioned Dual Masking Electrol

TOSHIBA Thermal Printer B-852-R SERIES. Maintenance Manual. Document No. EO Original Mar., 2006 (Revised ) PRINTED IN JAPAN

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

MiniForce II. HEPA Air Filtration Machine. Operation and Maintenance Manual

POST LANTERN ITEM # MODEL #39487 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

Installation Instructions

Fan Relay Board (FRBii) Assembly

SINK SPECIFICATIONS. ELONGATED DOUBLE BOWL Undermount Model VGR3218BL NOMINAL DIMENSIONS FEATURED MODELVGR3218BL 9" BOWL DEPTH

HEPA Filtration. HEPA DM 3000P Air Filtration System IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

INSTALLATION INSTRUCTIONS UNDERMOUNT SINKS

OWNER S MANUAL OM F

MODUL-CONNECT 1.2. Owner s Manual. Modular, digital wiring and control system. Document Part Number MSMC Rev 9 (04/18)

INSTALLATION INSTRUCTIONS TOP MOUNT SINKS

A1100 GUARDIAN OVERFILL PREVENTION SYSTEM

Cable Cubby 1202 and 1402 Installation Guide

Mania EF1 user manual

Installation Guide for EcoBrite EndLite LED Light Fixtures

Swing Arm Magnifying Lamp

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Toggle Button Kit. Installation Instructions

Air Knight REME by RGF

RESPA -SD or Gideon HVAC Fresh Air Filtration System Installation Guidelines for John Deere 450J, 550J, 650J, 700J, 750J, 850J Crawlers

Bulbs are not included. FF-OF4 Octa 4 Socket Fluorescent Fixture INSTRUCTIONS

Automatic Butter Dispenser Instruction Manual Model #2395NS

HONEYCOMB & PLEATED SHADES

OPERATION MANUAL MODEL MODEL MODEL MODEL MODEL NON-CONDUCTIVE ARTICULATING FIBERSCOPE INSTRUMENT TECHNOLOGY, INC.

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

Transcription:

MUV-401H GERMICIDAL AIR PURIFIER Installation & Maintenance Instructions UNPACKING THE UNIT Each MUV-401H germicidal air purifier is shipped with the germicidal lamp placed in a lamp box. Carefully remove lamp from the lamp box taking care to not touch the glass portion with bare hands. Oils from the hands can cause hot spots which reduce lamp life. Handle by the plastic end cap or use a soft cloth. Clean the lamp, using the included alcohol cleaning pad or a soft cloth dampened with rubbing alcohol. The lamp is fragile and proper care must be taken when removing from packaging. The following parts are included: MUV-401H Multivoltage Germicidal Air Purifier Germicidal Twin H Lamp (packed in lamp box) Four Sheet Metal Screws Installation & maintenance instructions 120 VAC Power Cord Alcohol cleaning pad IMPORTANT: SAFETY INSTRUCTIONS IMPORTANT: Instructions de securité When installing and using this electrical equipment, basic safety precautions should always be followed including the following: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. SAVE THESE INSTRUCTIONS. 3. Always be sure the unit is unplugged during installation or service procedures. 4. The ultraviolet light produced by the UV lamp is harmful to your eyes. Do not look directly at the lamp. Should it become necessary to view the lamp, use UV-protected sunglasses. Lors de l installation et de l utilisation de cet équipement, des précautions devront être suivies. 1- Lire et suivre les étapes attentivement. 2- Conserver ces instructions. 3- Assurez vous de toujours débrancher avant l installation ou le service. 4- Ne pas regarder la lampe directement avec les yeux. Si nécessaire de le faire, veuillez porter les lunettes de soleil contre les rayons U.V.

INSTALLATION Do not locate the unit within 20 of any plastic material that will be directly exposed to the UV light, such as wiring, a return side humidifier or certain types of air filters. Check with the filter manufacturer to see if their material is UV resistant. Over time, UV light may degrade plastic materials. Do not touch the glass portion of the lamp with bare hands because oils from the hands can cause hot spots which reduce lamp life. Handle either by the porcelain caps or use a soft cloth. If you accidentally touch a lamp, wipe it off, using a soft cloth dampened with rubbing alcohol. 1. Cut out the shaded area of the installation template (See page insert). Center the template on the longitudinal axis of the plenum and attach with tape. Trace the hole pattern for the unit and mark centers for mounting screws. 2. Cut opening for the unit using a 2" hole saw or tin snips. 3. Attach the unit to the air duct using the four self tapping sheet metal screws provided. 4. Remove the cover from the unit by removing the top and bottom retaining nuts using a 11/32 size nut driver. 5. Remove germicidal lamp holder using a 11/32 size nut driver (Figure B). 6. Slide germicidal lamp into lamp opening and reinstall lamp holder 7. Plug lamp into lamp connector. 8. Supply power by wiring unit according to instructions below. 9. Replace and secure cover using the two retaining nuts. WIRING There is no need to cycle the germicidal air purifier with the furnace blower. The multivoltage ballast is self-adjusting and operates with voltages from 120-240 VAC. Install provided 120 VAC power cord and plug the unit into a 120 VAC outlet which is interlocked with the furnace blower. If an EAC terminal is available, supply power to the outlet from the EAC terminal. Connect in accordance with local wiring codes. If there is no EAC terminal, interlock the UV unit with the furnace blower using an appropriate alternate. After installing verify voltage is operating between 120-240 VAC with air handler operating. For 240VAC wiring install 5 amp inline fuses and use optional 240 VAC power cord, Part #PC-240. MAINTENANCE This maintenance schedule is only a guideline, determined by average conditions. Actual conditions will dictate the frequency of cleaning and/or replacement of lamps. Do not touch the glass portion of the lamp with bare hands because oils from the hands can cause hot spots which reduce lamp life. Handle either by the porcelain caps or use a soft cloth. Clean the lamp using a soft cloth dampened with rubbing alcohol.

CLEANING THE LAMP - Recommended interval: 12 months 1. Unplug the power cord from the outlet, or disconnect power to the unit. 2. Remove the cover from the unit by removing the top and bottom retaining nuts using a 11/32 size nut driver. 3. Unplug the lamp connector from the end of the lamp. 4. Remove lamp holder using a 11/32 size nut driver. (Figure B) 5. Remove the lamp by grasping the porcelain cap and extract carefully. 6. Using a soft cloth moistened with rubbing alcohol, wipe down the lamp. If there is a large build-up of dust particles, you may wish to use a can of air first. Always handle lamp by the end caps. 7. Slide the lamp back into lamp opening and reinstall lamp holder. 8. Plug the lamp into the lamp connector. 9. Replace and secure the cover using the two retaining nuts. 10. Plug power cord back into outlet, or restore power to unit. REPLACING THE LAMP - Recommended interval: 24 months Replacement lamps are available through your HVAC contractor. Follow above procedure excluding #6. (Please note standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.) Germicidal Lamp Holder (Figure B)

TOP MUV-401H INSTALLATION TEMPLATE Cut out opening indicated in grey. You may also use a 2 hole saw centered over this area 1. Cut out area of template indicated by the dotted line. 2. Place template on the return path of the HVAC system and trace the hole pattern for the unit and mark centers for mounting screws. 3. Cut opening for the unit. 4. Install unit into air duct using the four self tapping sheet metal screws provided.

TROUBLESHOOTING The LED should light when the unit is operating. If the LED does not light: 1. Check to be sure there is power to the unit. 2. Be sure lamp connector is fastened securely. 3. If the LED still does not light, replace lamp. 4. If still not operating, replace ballast. WARRANTY All electronic components carry a lifetime warranty to the original homeowner. In addition there is a four- year warranty from the date of installation for any subsequent owner. The manufacturer reserves the right to send replacement parts or to replace the unit at its discretion. This warranty does not cover any labor or damage resulting from improper installation or abuse. Use of any lamp other than the manufacturer s lamp designed for this device will void the warranty. The original lamps are warranted for a period of two years. This warranty does not cover lamps broken during shipping, installation or as a result of improper handling. All returns are routed through your contractor/wholesaler and must be approved and accompanied by an RGA#. Please call 800-982-1840 and we will guide you through the return procedure. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. 18 Air flow 16 Twin Germicidal UV-C Lamp Box size is 8.75 high x 4.25 wide. 401H Furnace 2.75 Return Air Duct 2016 For technical support please call (800) 982-1840