A22TK Key-type Selector Switch with Direct Opening Mechanism

Similar documents
A22TK Key-type Selector Switch with Direct Opening Mechanism

Safety Interlock Switches

A22LK CSM_A22LK_DS_E_6_2

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4.

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Clicks for Three Easily Discernable Positions

A165E CSM_A165E_DS_E_11_2

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions. Ordering Information

Better Productivity by Standstill and Low-speed Monitoring

Safety Guard Switching Unit G9SX-GS

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

2NC (slow-action) Direct. Model. opening

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

DIN Track Terminal Blocks with Screw Terminals XW5T

S8JX-N/S8JX-G Series Replacement Brackets

A22E. Emergency Stop Switch (22-dia./25-dia.) Install in 22-dia. or 25-dia. Panel Cutout. Model Number Structure L M 24A 01

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

A4EG CSM_A4EG_DS_E_6_1

Digital display Pressure range ON/OFF output Linear output Model

D4BS CSM_D4BS_DS_E_8_4

D4GS-N CSM_D4GS-N_DS_E_7_2

DIN Track Terminal Blocks with Screw Terminals XW5T

DIN Track Terminal Blocks with Screw Terminals

M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

G3PE-Single-phase. Solid State Relays for Heaters

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) A22E/A22NE-P

2NC (slow-action) Direct. Model. opening

Multiple Limit Switch

D4BL. Guard Lock Safety-door Switch

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

D4BL. Guard Lock Safety-door Switch

Model Number Structure

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

Safety Limit Switch

Safety Switches & Operator Controls

D4NH CSM_D4NH_DS_E_7_1

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

High-power Solid State Relays G3PH

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

Quick Installation Manual

Redundancy Unit. Model Number Structure. Ordering Information. Model Number Legend. New Product. S8VK-R Series name

Pushbutton Switches 30-mm Pushbutton Switches Universal Design. Emphasis on Color Coding, Workability, and Safety.

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Sense7-series Non-contact coded safety switch

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

CSM_D4N-_R_DS_E_6_1

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

D4NS/D4NS-SK. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Nextgeneration. Model Number Structure. Model Number Legend

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai Ph: Mob: Fax:

A22E. Model Number Structure. Emergency Stop Switch. Model Number Legend. Completely Assembled. Install in 22-dia. or 25-dia.

A3S. Pushbutton Switch Series with Square 40-mm Body. Lighted Pushbutton Switch (Square) List of Models

High-power Solid State Relays G3PH

Smile 11 RA/-B Smile 12 RF/-G Reset button

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

EStrong-series Emergency Stop

Tina 11A Connection block

A22NK. Key-type Selector Switches

Tina 10A/B/C Adaptor unit

Tina 4A Connection block

FMC-1/2 Tina Muting unit

Smile 41 Push-button box with/without emergency stop

Small-diameter Proximity Sensor

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

A22. Install in 22-dia. or 25-dia. Panel Cutout (When Using a Ring) Pushbutton Switch (Cylindrical 22/25-dia.) List of Models

Safety Interlock Switches

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2

A22/M22. Specifications. Specifications Common to All. Complete Assemblies

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

MKey9-series Safety Interlock Switch with Guard Locking

Dimension A. Dimension B

Power ratings Input voltage Output Voltage Output current Boost Current Model number 120 W 2-phase and 3-phase

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

D4JL. Guard Lock Safety-door Switch. World's Top * Holding Force of 3,000 N. Features

D4NL. Guard Lock Safety-door Switch. Best-selling Guard Lock Safety-door Switch Available in Several Compact, Multi-contact Models

Hinged Safety Door Switch

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Safety Limit Switch

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Lighted Pushbutton Switch

Solid State Relays for Heaters

Solid State Relays G3NA. Model Number Structure. Model Number Legend

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

Transcription:

New Product Safety Key Selector Switch ATK Key-type Selector Switch with Direct Opening Mechanism Selector Switch for secure equipment activation during maintenance 30 types of exclusive keys make it more difficult to disable. The trapped key of the D4JL Guard Lock Safety-door Switch has the same shape as the lockout key of the D4GL-SK0-LK Slide Key Unit. Units can be combined to improve safety. (Specify the same key type.) Common to the switch part of Emergency Stop Switch AE. (Non-lighted model only) For safety precautions for all pushbutton switches, refer to the website at: www.ia.omron.com, and Safety Precautions on page in this catalog. Features Because the ATK Safety Key Selector Switch uses the same key as the Guard Lock Safety-door Switch, the operator is prevented from forgetting to remove the key. The result is a safer working environment when performing maintenance. Common Key for Door Switch and Selector Switch Broad range of applications include use with door locks, mode switching, and emergency stops when teaching Guard Lock Safety-door Switch D4GL-SK0-LK Safety Key Selector Switch Guard Lock Safety-door Switch D4GL-SK0-LK Safety Key Selector Switch ATK Enabling Grip Switch A4EG With the Selector Switch, it is possible to switch between normal operation mode (use of Door Switch is available) and maintenance mode (use of Enabling Grip Switch is available). ATK D4JL Safety Controllers such as Safety Guard Switching Unit G9SX-GS D4JL Common Key * To unify keys, specify the same key type.

ATK From Safety can be ensured, but there is a risk of human error occurring during operation. Guard Lock Safety-door Switch only When only the Door Switch is used, the operator is at risk of being shut inside the barrier if, for example, he/she forgets to remove the trapped key and a third party locks the door. The equipment may also be started up while the operator is inside. Guard Lock Safety-door Switch Key Selector Switch (AK) + The safety level is enhanced by switching to maintenance mode. However, because two different types of keys are required, the operator is still at risk of being shut inside if he/she forgets to remove the trapped key. Different keys I should close it. The equipment started up! I should close it. I'm trapped inside! Assumed risks Assumed risks Forgetting to remove the key Being trapped inside Starting equipment Forgetting to remove the key Being trapped inside To By using a common key, the risk of human error is reduced in operations from when the door is open/shut until the equipment is started. Guard Lock Safety-door Switch + Safety Key Selector Switch (ATK) The two locks on the door and equipment use the same key, reducing the likelihood that the user will forget to remove it. In addition, the key cannot be removed when maintenance is being performed. This prevents the key from being lost and greatly reduces the risk of an operator becoming trapped inside. Same Key Common key Unlock the door Operation stopped UNLOCK D4JL LOCK Start maintenance Operation double-stopped MAINTENANCE ATK Key: Cannot be removed RUN Guard Lock Safety-door Switch D4JL Key: Can be removed 3 Safety Key Selector Switch ATK 4 I take the key with me when I enter, so there is no worry of becoming trapped inside! 4 Lock the door Operation starts D4JL UNLOCK LOCK 3 End maintenance Operation stopped ATK MAINTENANCE RUN Key: Can be removed Key: Cannot be removed Same Key Furthermore By using the Enabling Grip Switch during maintenance and by using a Safety Laser Scanner or Safety Mat to detect the presence of operators, equipment malfunctions can be prevented when operators are inside, enabling a higher safety level.

ATK Model Number Structure Model Number Legend (Ordering as a set) The Operation Unit and Switch are delivered as a set. For information on combinations, refer to Ordering Information on page 5. () () (3) (4) ATK- LL - - K 0 () Operation Unit Symbol LL No. of notches Key release position Key position of NC contact closing (3) Key Availability Symbol Type None No key K With key (4) Key Type 0 to 30: 30 types * RL LR RR () Contact Configuration Symbol Type 0 SPST-NC SPST-NO/SPST-NC 0 DPST-NC DPST-NC + SPST-NO DPST-NO + SPST-NC 03 TPST-NC * Key can be created up to 30 types. Specify keys in order starting from 0. Key drop preventive type ATK-@ - @ - @ 0-SJ () () (3) () Operation Unit () Contact Configuration (3) Key Availability Symbol LL No. of notches Key release position Key position of NC contact closing Symbol Type 0 SPST-NC SPST-NO/SPST-NC Symbol None K Type No key With key 0 DPST-NC RL LR DPST-NC+SPST-NO DPST-NO+SPST-NC 03 TPST-NC RR Key drop preventive (on the ATK-RL-@) NC contact: ON Key: Hold Standard type Operating range NC contact: OFF Key: Removed Key drop preventive type NC contact: ON Key: Hold Operating range NC contact: OFF Key: Removed NC contact: OFF Key: Hold 3

ATK Contact Configuration ATK-@L Key position SPST-NC SPST-NO/SPST-NC DPST-NC DPST-NC + SPST-NO DPST-NO + SPST-NO TPST-NC ATK-@R Key position SPST-NC SPST-NO/SPST-NC DPST-NC DPST-NC + SPST-NO DPST-NO + SPST-NO TPST-NC Operation Angle ATK-L@ ATK-L@-SJ ATK-R@ ATK-R@-SJ FP : Free position TTP : Total travel position HP : Key hold position (drop prevention) * *. If the key is stopped at a position between FP and TTP, the contacts will not be in the states indicated above. Always be careful to turn the key completely to the FP (HP) or TTP position to ensure that the contacts are properly switched and the direct open circuit operation characteristics are obtained. *. Key drop preventive type (ATK-@-SJ or ATK-@-SJ only) 4

ATK Ordering Information Switch List of Models (Completely Assembled)... Shipped as a set which includes the Operation Unit and Switch. For the model with Operation Unit only, contact your OMRON representative. Appearance Key release position * Models with Korean S-mark certification. Key position of NC contact closing Contact Configuration Key availability Model SPST-NC ATK-LL-0-K0 * SPST-NO/SPST-NC ATK-LL--K0 * DPST-NC ATK-LL-0-K0 * DPST-NC + SPST-NO ATK-LL--K0 * DPST-NO + SPST-NC ATK-LL--K0 * TPST-NC ATK-LL-03-K0 * SPST-NC ATK-RL-0-K0 * SPST-NO/SPST-NC ATK-RL--K0 * DPST-NC ATK-RL-0-K0 * DPST-NC + SPST-NO ATK-RL--K0 * DPST-NO + SPST-NC ATK-RL--K0 * TPST-NC ATK-RL-03-K0 * Yes SPST-NC ATK-LR-0-K0 * SPST-NO/SPST-NC ATK-LR--K0 * DPST-NC ATK-LR-0-K0 * DPST-NC + SPST-NO ATK-LR--K0 * DPST-NO + SPST-NC ATK-LR--K0 * TPST-NC ATK-LR-03-K0 * SPST-NC ATK-RR-0-K0 * SPST-NO/SPST-NC ATK-RR--K0 * DPST-NC ATK-RR-0-K0 * DPST-NC + SPST-NO ATK-RR--K0 * DPST-NO + SPST-NC ATK-RR--K0 * TPST-NC ATK-RR-03-K0 * SPST-NC ATK-LL-0-0 * SPST-NO/SPST-NC ATK-LL--0 * DPST-NC ATK-LL-0-0 * DPST-NC + SPST-NO ATK-LL--0 * DPST-NO + SPST-NC ATK-LL--0 * TPST-NC ATK-LL-03-0 * SPST-NC ATK-RL-0-0 * SPST-NO/SPST-NC ATK-RL--0 * DPST-NC ATK-RL-0-0 * DPST-NC + SPST-NO ATK-RL--0 * DPST-NO + SPST-NC ATK-RL--0 * TPST-NC ATK-RL-03-0 * No SPST-NC ATK-LR-0-0 * SPST-NO/SPST-NC ATK-LR--0 * DPST-NC ATK-LR-0-0 * DPST-NC + SPST-NO ATK-LR--0 * DPST-NO + SPST-NC ATK-LR--0 * TPST-NC ATK-LR-03-0 * SPST-NC ATK-RR-0-0 * SPST-NO/SPST-NC ATK-RR--0 * DPST-NC ATK-RR-0-0 * DPST-NC + SPST-NO ATK-RR--0 * DPST-NO + SPST-NC ATK-RR--0 * TPST-NC ATK-RR-03-0 * 5

Appearance * These models will receive Korean S-mark certification Accessories Key release position Key position of NC contact closing ATK Contact Configuration Key availability Model b ATK-LL-0-K0-SJ * ab ATK-LL--K0-SJ * b ATK-LL-0-K0-SJ * ab ATK-LL--K0-SJ * ab ATK-LL--K0-SJ * 3b ATK-LL-03-K0-SJ * b ATK-RL-0-K0-SJ * ab ATK-RL--K0-SJ * b ATK-RL-0-K0-SJ * ab ATK-RL--K0-SJ * ab ATK-RL--K0-SJ * 3b ATK-RL-03-K0-SJ * Yes b ATK-LR-0-K0-SJ * ab ATK-LR--K0-SJ * b ATK-LR-0-K0-SJ * ab ATK-LR--K0-SJ * ab ATK-LR--K0-SJ * 3b ATK-LR-03-K0-SJ * b ATK-RR-0-K0-SJ * ab ATK-RR--K0-SJ * b ATK-RR-0-K0-SJ * ab ATK-RR--K0-SJ * ab ATK-RR--K0-SJ * 3b ATK-RR-03-K0-SJ * b ATK-LL-0-0-SJ * ab ATK-LL--0-SJ * b ATK-LL-0-0-SJ * ab ATK-LL--0-SJ * ab ATK-LL--0-SJ * 3b ATK-LL-03-0-SJ * b ATK-RL-0-0-SJ * ab ATK-RL--0-SJ * b ATK-RL-0-0-SJ * ab ATK-RL--0-SJ * ab ATK-RL--0-SJ * 3b ATK-RL-03-0-SJ * No b ATK-LR-0-0-SJ * ab ATK-LR--0-SJ * b ATK-LR-0-0-SJ * ab ATK-LR--0-SJ * ab ATK-LR--0-SJ * 3b ATK-LR-03-0-SJ * b ATK-RR-0-0-SJ * ab ATK-RR--0-SJ * b ATK-RR-0-0-SJ * ab ATK-RR--0-SJ * ab ATK-RR--0-SJ * 3b ATK-RR-03-0-SJ * Name Appearance Classification Model Remarks Control Box One hole, yellow box (for emergency stop) AZ-B0Y Material: Polycarbonate resin Note: For information on two-hole and three-hole control boxes, contact your OMRON representative. The Switch Block, Mounting Latch, Connector, and Lock Plate of AE can be used. 6

ATK Specifications Approved Standard Ratings UL, cul (File No. E455): 6 A at 0 VAC, 0 A at 0 VAC TÜV (EN60947-5-) (Low Voltage Directive): 3 A at 0 VAC CCC (GB4048.5): 3 A at 40 VAC,.5 A at 4 VDC Certified Standards Certification body Standards File No. UL * UL508, C. No.4 E455 TÜV SÜD EN60947-5- (certified direct opening mechanism) Inquire CQC(CCC) GB4048.5 00300303070635 KOSHA EN60947-5- 009-56 Note: Only models with NC contacts have a direct opening mechanism. *. UL-certification for CSA C. No. 4 and bears the mark. Ratings Contacts (Standard load) Rated carry current (A) 0 380 0. 0. Note:. Rated current values are determined according to the testing conditions. The above ratings were obtained by conducting tests under the following conditions. () Ambient temperature: 0±C () Ambient humidity: 65±5% RH (3)Operating frequency: 0 operations/minute. Minimum applicable load: 0 ma at 5 VDC Characteristics Rated voltage (V) AC5 (inductive load) AC (resistive load) 4 VAC 0 0 Rated current (A) DC3 (inductive load) DC (resistive load) 0 5 0 0 3 6 - - 380 3 440 4 VDC.5 0 0 0.5 - - 0 0. 0.6 Item Model ATK Allowable operating Mechanical 30 operations/minute max. frequency Electrical 30 operations/minute max. Insulation resistance Dielectric strength Vibration resistance * Shock resistance Durability Between terminals of same polarity Between each terminal and ground Destruction 000 m/s Malfunction * Mechanical Electrical Ambient operating temperature * Ambient operating humidity Ambient storage temperature 00 MΩ min. (at 500 VDC),500 VAC, 50/60 Hz for min.,500 VAC, 50/60 Hz for min. 0 to 55 Hz,.5-mm double amplitude (within ms) 50 m/s max. 00,000 operations min. 00,000 operations min. -0 to +70 C 35% to 85%RH -40 to +70 C Degree of protection IP65 *3 Electric shock protection class PTI (tracking characteristic) 75 Degree of contamination Class II 3 (EN60947-5-) *. Malfunction within ms. *. With no icing or condensation. *3. The degree of protection from the front of the panel. Note:. Do not allow the load current to exceed the rated value.. The contact ON/OFF timing is not synchronized. Confirm performance before application. 3. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced. 7

Structure and Nomenclature ATK Key * Two keys are provided. Operation Unit Switch Contact Ratings 0 A at 0 VAC (resistive load) 0 A at 4 VDC (resistive load) Contact Configuration SPST-NC, SPST-NO/SPST-NC, DPST-NC, DPST-NC + SPST-NO, DPST-NO + SPST-NC, and TPST-NC Lock Plate (attached with the Switch) (Refer to "Mounting the Lock Plate" on page for use.) (The above figures are examples of the model with key.) Dimensions (Unit: mm) ATK-LL Lock Plate (included) (AZ-3380) ATK-RL Lock Plate (included) (AZ-3380) Key Key 30 dia. 7 dia. 9.5 dia. 34 30 dia. 7 dia. 9.5 dia. 34 6.5 0.5 0.9 5.9 6.5 0.5 0.9 5.9 3. 3.6 54.7 3. 3.6 54.7 Terminal Arrangement (Bottom View) Contacts 3 Contacts 0.7 0 OPEN LOC OPEN LOC 6.7 6.7 M3.5 screws Switch blocks Switch blocks Terminal Connection Terminal connection (Bottom View) Type SPST-NO/SPST-NC DPST-NC DPST-NC + SPST-NO DPST-NO + SPST-NC TPST-NC 3 3 3 3 Non-lighted 4 4 4 4 8

ATK Application Examples G9SX-BC : Manual reset, cross fault detection: ON (category 4 wiring) G9SX-GS : Manual reset, cross fault detection: ON (category 4 wiring), logical AND connection setting: AND OFF-delay time setting: Time is set. Switching mode: Manual External indicator diagnosis: Enabled Emergency Stop Switch S Feedback loop KM KM Lock release signal S5 KM3 KM4 S4 S A T T T T T3 T3 T33 Y G9SX-BC0 (Unit ) +4V Open KM KM M 4 4 Guard lock Safety-door Switch +4V Control circuit A S4 S4 L L X X S3 Enabling Switch Door S6 Feedback loop GND KM KM PLC etc. () (4) OPEN KM3 +4V () (3) S8 Selector Switch ATK Open Open A T T T T Y Y3 M M T6 T6 T7 T7 Y Y4 T3 T3 T33 T4 T4 G9SX-GS6-T5 (Unit ) Stop signal +4V Control circuit Open Open S7 KM4 +4V AND OFF Manual Auto KM3 KM4 S: Emergency Stop Switch S, S7: Reset switches S3: Enabling Switch S4: Guard lock Safety-door Switch S5: Lock release switch S6: Safety limit switch S8: ATK Safety Key Selector Switch KM to KM4: Contactors M to M: 3-phase motor A S4 S4 S44 S54 L X X X3 X4 UA UB M KM3 KM4 PLC etc. GND Timing Chart <G9SX-BC0(Unit )> Emergency Stop Switch S Reset switch S Unit S4, S4 KM, KM NC contact KM, KM NO contact Unit Logical AND output L <G9SX-GS6-T5(Unit )> Unit Logical AND input T4 Guard lock safety-door switch S4 Enabling Switch S3 Reset switch S7 Mode selection input M Mode selection input M Unit S4, S4 () () (3) (4) (6) Indicator (Diagnostic check enabled) (8) (5) (7) (9) Indicator (Diagnostic check enabled) (0) () The G9SX-GS starts in operation mode. () The mode switches to maintenance mode. (3) The operator opens the door and performs maintenance work. (4) The Enabling Switch is gripped to the middle position. (5) The G9SX-GS starts in maintenance mode. (6) The G9SX-GS will stop when the Enabling Switch is released or gripped. (7) The G9SX-GS will start again after the door is closed and the mode is switched to operation mode. (8) The G9SX-GS will stop when the door is open while in operation mode. (9) The door is closed and the G9SX-GS starts again. (0)All the units will stop if the emergency stop is pressed. KM3, KM4 NC contact KM3, KM4 NO contact OFF-delay time OFF-delay time OFF-delay time OFF-delay time 9

ATK G9SX-LM4 (4 VDC) (Guard lock safety-door switch (Mechanical lock), -channel safety limit switch input/-channel enabling switch input/auto reset) + G9SX-BC0 (4 VDC) (-channel emergency stop switch input/manual reset) Lock release switch S5 E E 4 S4 Guard lock Safety-door Switch Emergency Stop Switch S7 Enabling Switch Guard open S6 +4V Selector Switch ATK 4 S8 Stop signal S3 Feedback loop KM KM S +4V S Open A T T T T T3 T3 T33 Y G9SX-BC0 Control circuit A S4 S4 L L X X PLC etc. +4V +4V Open Open A T T T T Y M M T6 T6 T7 T7 Y T3 T3 G9SX-LM4-F0 Control circuit A S4 S4 ES ES L X X X3 X4 D D D D Brown Black Brown Black KM KM Indicator Blue T33 T4 T4 AND OFF S: Emergency Stop Switch S: Reset switch S3: Safety limit switch S4: Guard lock Safety-door Switch S5: Lock release switch S6: ATK Safety Key Selector Switch S7: Enabling switch S8: Stop signal KM, KM: Contactor M: 3-phase motor GND Motor controller KM Rotator (interlocked with M) KM M Note: This circuit diagram is for Category 3. Timing Chart Emergency Stop Switch S Reset switch S Logical AND output L Safety limit switch S3 Guard lock Safety-door Switch S4 Guard closed --> opened KM, KM NC contact KM, KM NO contact (Operation instruction to the motor) Motor rotation Lock release signal (Safe speed detection output) ES Lock release switch S5 Mode selection input M Mode selection input M Enabling Switch S7 High speed rotation Low speed rotation Guard can be opened. 0

ATK Installation Mounting to the Panel The panel dimensions are shown below. Recommended panel thickness: to 5 mm. 3. +0. 0 () Preparing the Panel (3) Mounting the Switch on the Operation Unit -R0.8MAX. Insert the Operation Unit into the Switch Unit, aligning the arrow mark inscribed on the Case with the lever on the Switch Blocks, then move the lever in the direction indicated by the arrow in the following figure. Lever +0.4 4. 0 Switch Unit +0.4.3 0 dia. Arrow mark A Lock Ring is provided as a standard feature. When painting or coating the panel, make sure that the specified panel dimensions apply to the panel after painting or coating. Operation Unit () Mounting the Operation Unit on the Panel (4) Removing the Switch Insert the Operation Unit from the front surface of the panel, insert the Lock Ring and the mounting ring from the terminal side, then tighten the ring. Before tightening, check that the rubber washer is present between the Operation Unit and the panel. Tighten the mounting ring at a torque of 0.98 to.96 N m. When using a Lock Ring, insert the projecting part into the lock slot, and then tighten the mounting ring. Move the lever in the direction indicated by the arrow in the following figure, then pull the Operation Unit or the Switch Blocks. Since the lever has a hole with an inside diameter of 6.5 mm, the lever can be moved in the specified direction by inserting a screwdriver into the hole and then moving the screwdriver. Key Operation Unit Arrow mark Projecting part Mounting ring OPEN LOCK Screwdriver +0.4 dia. 0 dia. 4. +0.4 0 Rubber washer Panel Lock Ring Installing/Removing the Switch Blocks () Installing the Switch Blocks () Removing the Switch Blocks Wiring Hook the small protrusion on the Mounting Latch into the groove on the other side of the lever, then push up the Switch Block in the direction indicated by the arrow in the figure below. Insert a screwdriver between the Mounting Latch and the Switch Block, then push down the screwdriver in the direction indicated by the arrow in the following figure. Loosen the terminal screw from the Switch Unit until it completely comes off the groove, insert a screwdriver as shown in the following figure, then push up the washer in the direction indicated by the arrow to temporarily secure it. Now, a round crimp terminal can be connected. After inserting the terminal, tighten the screws to complete wiring. Washer Mounting Latch Lever Screwdriver Screw Protrusion Screwdriver Switch block Use either of the following screwdrivers. Flat-head screwdriver 3 to 6 mm Phillips screwdriver 3 to 6 mm dia.

Safety Precautions Be sure to read the precautions for all pushbutton switches in the website at www.ia.omron.com. DANGER Always confirm that safety functions are operational before stating operation. Wiring mistakes, setting mistakes, switch failure or other factors may prevent safety functions from operating. This may result in the machine continuing to operate, possibly resulting in human accidents. CAUTION If the Operation Unit is separated from the Socket Unit, the equipment will not stop, creating a hazardous condition. Secure the lever on the Socket Unit by using the AZ- 3380 Lock Plate so that the Operation Unit cannot be easily separated from the Socket Unit. (Refer to Mounting the Lock Plate at the right.) [Used in combination with a Slide Key] The machine may operate, possibly causing injury. Do not disable safety function by using a spare door switch operation key or spare key with the door open. [Used outside/inside hazardous area] The machine may operate, possibly causing injury. Do not disable safety function by using a spare key outside or inside the hazardous area. Precautions for Safe Use Installation Environment Do not use the switch in locations where explosive or flammable gasses may be present. Do not use the switch submerged in oil or water or in locations continuously subject to splashes of oil or water. Doing so may result in oil or water entering the switch. Wiring Connect a fuse in series with the ATK to protect it from shortcircuit damage. The value of the breaking current of the fuse must be calculated by multiplying the rated current by 50% to 00%. When using the ATK for an EN rating, use a 0-A fuse of type gi or gg that complies with IEC 6069. Always make sure that the power is turned OFF before wiring the Switch. Also, do not touch the terminals or other current-carrying ports while power is being supplied. Check the contact specifications before mounting the Switch Block. Use an NC contact for a safety circuit. It may not operate properly. Check the Switch Block for safe operation before use. Check the operating specification before mounting the Operation Unit. It may not operate properly. Check the Operation Unit for safe operation before use. Installation Do not drop the Switch. Doing so may prevent the Switch from functioning to its full capability. Make sure the Switch is mounted securely to prevent it from falling off. Otherwise injury may result. Mount the Operation Key so that it will not come into contact with persons in the area when the door is opened and closed. Injury may result. Do not use a Switch as a stopper. Otherwise, the switch may be ATK damaged and may not operate properly. Be sure to use the supplied Lock Ring. Otherwise, the switch may rotate and may not operate properly. Others Do not attempt to disassemble or modify the Switch. Doing so may cause the Switch to malfunction. The durability of the Switch is greatly influenced by the switching conditions. Always test the switch under actual working conditions before application and use it in a switching circuit for which there are no problems with performance. The user must not maintain or repair equipment incorporating the Switch. Contact the manufacturer of the equipment for any maintenance or repairs required. Operating Environment This Switch is designed for use indoors. Using the Switch outdoors may damage it. Do not use the Switch where corrosive gases (e.g., HS, SO, NH3, HNO3, or CI) are present or in locations subject to high temperature and humidity. Doing so may result in damage to the Switch as a result of contact failure or corrosion. Do not use the Switch in any of the following locations. Locations subject to extreme temperature changes Locations subject to high humidity or condensation Locations subject to excessive vibration Locations where metal dust, processing waste, oil, or chemicals may enter through the protective door Locations subject to detergents, thinners, or other solvents Storage Do not store the Switch where corrosive gases (e.g., HS, SO, NH3, HNO3, or Cl) or dust is present, or in locations subject to high temperature or high humidity. Mounting Do not tighten the mounting ring more than necessary using tools such as pointed-nose pliers. Doing so will damage the mounting ring. The tightening torque is 0.98 to.96 N m. Recommended panel thickness: to 5 mm. Mounting the Lock Plate. Confirm that the lever on the Mounting Latch is on the side where the Operation Unit is secured and then insert the protrusion on the Lock Plate into the hole in the lever on the Mounting Latch.. Press the hole on the Lock Plate onto the protrusion on the Mounting Latch until it clicks into place. After mounting the Lock Plate, check that the lever does not move. Operation Unit Mounting Latch Precautions for Correct Use Lever OPEN LOCK Lock Plate. Operating the Key When rotating the key to the total travel position or free position, the operating force must be.47 N m max..

ATK Wiring Terminal screws must be Phillips or slotted M3.5 screws with a square washer. The tightening torque is.08 to.7 N m. Single wires, stranded wires, and crimp terminals can be connected to the Switch Applicable Wiring Materials: Twisted strands: mm max. Solid wire:.6 mm dia. max. Naked Crimp Terminals 8 mm max. Crimp Terminals with Insulating Sheaths 8 mm dia. max. 8 mm max. 8 mm dia. max. Others If the panel is to be coated, make sure that the panel meets the specified dimensions after coating. Due to the structure of the Switch, severe shock or vibration may cause malfunctions or damage to the Switch. Also, most Switches are made from resin and will be damaged if they come into contact with sharp objects. Particularly scratches on the Operation Unit may create visual and operational obtrusions. Handle the Switches with care, and do not throw or drop them. 6.0 mm max. 6.0 mm max. 0. mm max. 0. mm max. Do not allow the Switch to drop and hit the floor. After wiring the Switch, maintain an appropriate clearance and creepage distance. Do not pull the lead wires with excessive force. Doing so may disconnect them. The cable cannot be bended repeatedly. When bending the cable, provide a bending radius of 45 mm min. so as not to damage the cable insulation or sheath. Excessive bending may cause fire or leakage current. Operating Environment The IP65 model is designed with a protective structure so that it will not sustain damage if it is subjected to water from any direction to the front of the panel. The Switch is intended for indoor use only. Using the Switch outdoor may cause it to fail. Using the Microload Contact failure may occur if a Switch designed for a standard load is used to switch a microload. Use Switches within the application ranges shown in the following graph. Even within the application range, insert a contact protection circuit, if necessary, to prevent the reduction of life expectancy due to extreme wear on the contacts caused by loads where inrush current occurs when the contact is opened and closed. The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% (λ 60) (conforming to JIS C5003). The equation, λ 60 = 0.5 x 0-6 /time indicates that the estimated malfunction rate is less than /,000,000 with a reliability level of 60%. Hammer Screwdriver Do not place or drop heavy objects on the Switch. Do not operate the Switch with hard or sharp objects. Perform maintenance inspections periodically. Do not use the key switch to stop/start the machine. Mode switching by key must be performed by the operator specified in the operating manual. Apply load current not to exceed the rated value. The contact ON/OFF timing is not synchronized. Confirm performance before application. Voltage (V) 30 0.6mA.6mA 00mA 4 Microload area Area of use Standard load area 5 Invalid area ma 0mA 0 0. 0 00,000 Current (ma) 3

READ AND UNDERSTAND THIS CATALOG Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer s application or use of the product. At the customer s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user s programming of a programmable product, or any consequence thereof. Copyright and Copy Permission COPYRIGHT AND COPY PERMISSION This document shall not be copied for sales or promotions without permission. This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.

OMRON Corporation Industrial Automation Company Tokyo, JAPAN Contact: www.ia.omron.com Authorized Distributor: Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-3 JD Hoofddorp The Netherlands Tel: (3)356-8-300/Fax: (3)356-8-388 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby ), Alexandra Technopark, Singapore 9967 Tel: (65) 6835-30/Fax: (65) 6835-7 OMRON SCIENTIFIC TECHNOLOGIES INC. 6550 Dumbarton Circle, Fremont CA 94555-3605 U.S.A. Tel: () 50-608-3400/Fax: () 50-744-44 OMRON (CHINA) CO., LTD. Room, Bank of China Tower, 00 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 000, China Tel: (86) -5037-/Fax: (86) -5037-00 OMRON Corporation 009 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM 0 Cat. No. A89-E-0 Printed in Japan 0409