BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Similar documents
BASYS Infrared Sensor Activated

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

ETF-600 Sensor Operated Lavatory Faucet

INSTALLATION INSTRUCTIONS FOR SLOAN SF ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR-ACTIVATED LAVATORY FAUCETS

BASYS Infrared Sensor Activated

Optima ETF-600/ETF-610

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

INSTALLATION INSTRUCTIONS FOR ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

INSTALLATION INSTRUCTIONS FOR EAF-350 SERIES ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

G2 Optima Plus Flushometer

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED LAVATORY FAUCETS

Maintenance Guide. OPTIMA Components:

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

Sloan Automatic Infrared Sensing Faucets

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet

INSTALLATION INSTRUCTIONS SINGLE, DOUBLE, TRIPLE AND QUADRUPLE STATION SENSOR OPERATED SOLID SURFACE AND BIO-DECK LAVATORY SYSTEMS ELC-41000

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

Aqua-FIT Serio Series TM

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

OPERATION & MAINTENANCE MANUAL 5000E Series Faucet

Installation For Service Only

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC ACTIVE IR LAVATORY FAUCETS

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

AquaSense ZTR Series

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Milano AUTOMATIC FAUCET

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

LIGATURE RESISTANT SENSOR FAUCET

INSTALLATION INSTRUCTIONS SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM FLUSHOMETERS EXPOSED CLOSET, URINAL & SERVICE SINK INSTALLATIONS.

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

Electronic Hand Washing Faucet

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

Installation Instructions

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

Troubleshooting Guide HYBRIDFLUSH AEF-801 SERIES

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS

EBF-550. Battery Powered Hand Washing Faucet

AquaSense ZTR Series

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS

MAC FAUCETS. FA400 Wall Mount Sensor

EcoVantage AV. ZRK Dual Flush Series. Sensor-Operated, Battery-Powered Retrofit Kit. Installation, Operation, Maintenance, and Parts Manual

MAC FAUCETS. FA400 Autoluxe Faucets

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

Installation Instructions

Installation Instructions

MAC FAUCETS FA400 WALL MOUNT FAUCETS

AquaSense AV ZR Series Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance and Parts Manual

Effective Date: May Rev. 1/9/2018- Void After: May Product: Lead Free Plumbing Products File No. 6905

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

Installation Instructions

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS

Installation Instructions / Warranty. Citterio 39115XX1

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

Sensor Activated Lavatory Faucet Installation, Operation & Service Instructions Model Numbers Tools & Materials Need Help?

Installation. Tools. Single Handle Kitchen Faucet With Optional Spray. Maintenance. Safety Tips. Important Points. Need Help? For Model:

Installation Instructions / Warranty

Installation Instructions

Installation Instructions

6-12 WIDESPREAD 6-12 W. Cleopatra Series INSTRUCTION GUIDE SAVE THIS INSTRUCTION GUIDE

Installation Instructions

Outdoor Bottle Fillers

Artec Pro Single Handle Commercial Kitchen Faucet

INSTALLATION INSTRUCTIONS

Installation Instructions

Electronic Faucet - 591T Series

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

Camaya Series Soap Dispenser

Allura. Widespread Lavatory Faucet SLW-4712 Installation and Service Instructions. Quick Install Guide Allura Widespread Lavatory Faucet, SLW-4712

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

INSTALLATION INSTRUCTIONS. Automatic Sensor Retrofit Kit For Urinals and Toilets ZERK-CP Chrome-Plated Cover ZERK-CPM Chrome-Plated Metal Cover

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

FOR TECHNICAL ASSISTANCE

G SERIES - E TOUCH MIXER / TAP

Installation Instructions

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

Installation Instructions

Automatic Sensor Faucet Installation Manual CAT ALL-IN-ONE AUTO VALVE FAUCET HORIZONTAL WATER SPOUT. Revision

Transcription:

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets Any Application. Any Environment. Code No. 0816407 Rev. 5 (05/16) EFX-6XX Integrated Base, Sensor Activated Lavatory Faucets MODEL GUIDE EFX 0. 1. 0 0 Body Type Power Crown. Mix Sensing Flow Rate. Batteries Base Plate Adapters 0 Hardwire Bowed. None 0.5 gpm Multi-Lam. Alkaline None None No 1. 2. Below Deck Mechanical Below Deck Thermostatic 3 Pedestal. Drain Pop- Up Capacitance. 4-inch US Plug-in 1.5 gpm (5.7 Lpm) Aerated Insert 1.5 gpm (5.7 Lpm) Laminar Insert. 8-inch. 4.. 5 Battery.. 6 Integrated Base.. 7.. 8 Turbine.. Base Plates are not intended for the integrated base models. LIMITED WARRANTY Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship for a period of three (3) years (1 year for SF faucets, special finish and PWT electronics and 30 days on PWT software) from date of first purchase. During this period, Sloan Valve Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned to Sloan Valve Company, at customer s cost. No claims will be allowed for labor, transportation or other costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the battery. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER. PRIOR TO INSTALLATION Prior to installing the Sloan BASYS Series Faucets, install the items listed below. Also, refer to rough-in illustrations. IMPORTANT: ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS. FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS. KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT COMPONENT PART DAMAGE! DO NOT USE ANY SEALANT ON COMPRESSION FITTINGS. Base Plates When the BASYS Faucet is installed on a sink that has three (3) hole punchings, a base plate should be used. Base Plates should be specified at the time of ordering. EFX-20-A 4 (102 mm) Centerset Sinks EFX-26-A 8 (203 mm) Centerset Sinks IMPORTANT Not for installation on a metal sink or deck (i.e. stainless steel or cast metal).

TOOLS REQUIRED FOR INSTALLATION 13 mm open end wrench or nut driver for faucet retainer nut 2.5 mm hex allen wrench 5/8 open end wrench for female end of flex hose FAUCET ROUGH-IN 6.25 (159 mm) 2 (51 mm) 4 (106 mm) 5 (126 mm) 2 (47.5 mm) 42 2.5 (63 mm) 1.25 (31 mm) 5.7 (147 mm) 6 (152 mm) 2 (51 mm) 4 (106 mm) 5 (124 mm) 2 (46 mm) 42 2.5 (63 mm) 1.25 (31 mm) 2.25 (57 mm) 2

FAUCET ROUGH-IN (CONTINUED) EFX-3X0.X1X.0000 WITH HOT/COLD WATER SUPPLY SPOUT EFX-3X0.01X.0100 WITH TEMPERED WATER SUPPLY AND 4-INCH BASE PLATE SPOUT EFX-6X0.X1X.0000 WITH HOT/COLD WATER SUPPLY SPOUT 1-3/16 (30 mm) MIN. DIA. REQUIRED BASE PLATE 1-3/16 (30 mm) MIN. DIA. REQUIRED 1-3/16 (30 mm) MIN. DIA. REQUIRED MOUNTING HARDWARE MOUNTING HARDWARE MOUNTING HARDWARE OPTIONAL ADAPTER CONTROL MODULE OPTIONAL ADAPTER CONTROL MODULE OPTIONAL ADAPTER CONTROL MODULE 3/8 (10 mm) SUPPLY TUBE (BY OTHERS) BELOW DECK THERMOSTATIC MIXING VALVE TEMPERED SUPPLY 3/8 (10 mm) SUPPLY TUBE (BY OTHERS) BELOW DECK THERMOSTATIC MIXING VALVE HOT SUPPLY BELOW DECK MECHANICAL MIXING VALVE SHOWN INSTALLED COLD SUPPLY 3/8 (10 mm) COMPRESSION STOPS (BY OTHERS) HOT SUPPLY BELOW DECK MECHANICAL MIXING VALVE SHOWN INSTALLED COLD SUPPLY 3/8 (10 mm) COMPRESSION STOPS (BY OTHERS) 3/8 (10 mm) COMPRESSION STOPS (BY OTHERS) IMPORTANT Not for installation on a metal sink or deck (i.e. stainless steel or cast metal). EFX Faucets are available with a 0.5 gpm (1.9 Lpm) multi-laminar spray, 1.5 gpm (5.7 Lpm) aerated stream, and 1.5 gpm (5.7 Lpm) laminar stream. 1 - INSTALL FAUCET AND MOUNT CONTROL MODULE A Remove nut, faucet retainer and gasket. B Install faucet into the center hole in deck or lavatory 1-3/16 (30 mm) minimum hole required. C Install mounting bracket under deck or lavatory ensuring there is enough clearance for the flexible supply hose from the faucet to connect to the control module. Install control module at a 45º angle and turn right to secure. 3

2 - INSTALL FLEX HOSE ASSEMBLY TO SUPPLY STOP AND CONTROL MODULES A Connect LED power plug and capacitance plug to control module. D Secure flex hoses to the control module by opening supply hose stainless steel clips. FROM FAUCET LED POWER PLUG CAPACITANCE PLUG IMPORTANT: IF CAPACITANCE PLUG/WIRE IS BENT/DAMAGED/ BROKEN FAUCET WILL NOT WORK. ENSURE CAPACITANCE WIRE IS AT LEAST 1/2 FROM ANY METAL, SUCH AS WATER SUPPLY. FLUSH DIRT, DEBRIS AND SEDIMENT FROM SUPPLY LINE(S) BEFORE CONNECTING FLEX HOSES. B C Install flex hose(s) onto supply stop(s). Connect hot and cold supply stop hoses to mixing valve and flex hose to connect to control module. Tighten the flex hose securely to the supply. E Close supply hose stainless steel clips. NOTE: NEVER OPEN STAINLESS STEEL CLIPS WHEN WATER SUPPLY IS TURNED ON. FROM MIXING VALVE OR TEMPERED WATER SUPPLY LINE F Insert battery assembly. G Turn on water. 3 - ACTIVATION AND OPERATION OF FAUCET A continuous ambient field is emitted and monitored by the faucet system. As the user s hands enter the effective range the sensor activates the solenoid valve allowing tempered water to flow from the faucet. Water will flow until the hands are removed or until the faucet reaches its automatic time out setting. When hands are moved away from the faucet, the capacitance sensor deactivates the solenoid valve, shutting off the water flow. The system automatically resets and is ready for the next user. 4

4 - BATTERY REPLACEMENT NOTE: REPLACE BATTERY WHEN RED BATTERY INDICATOR LED FLASHES 4 TIMES EACH TIME FAUCET IS IN USE OR WHEN FAUCET STOPS FUNCTIONING. A B No need to turn off water. Loosen screw with hex wrench and remove cover. NOTE: IT IS POSSIBLE FOR THE FAUCET TO ACTIVATE WHEN THE CAP WIRE OR SOLENOID IS TOUCHED OR WHEN THE CONTROL MODULE COVER IS BEING SCREWED ONTO THE MANIFOLD. E Twist top of battery pack counter-clockwise to open. Remove batteries and replace batteries with four (4) new AA batteries. Twist top of battery pack clockwise to close. C Slide cover forward and lift off. D Remove battery case. F Replace cover. 5

REPLACE FILTER A Disconnect solenoid wire from control module. E Remove new filter from control module cover. B Turn solenoid caddy counterclockwise lining up arrows on control module and solenoid caddy assembly. F Snap new filter onto solenoid caddy assembly. C Remove solenoid caddy assembly from control module by pulling straight out. G Insert solenoid caddy assembly into control module lining up arrows. Turn solenoid caddy assembly clockwise 45º. Reconnect solenoid caddy wire to control module. D Remove filter from solenoid caddy assembly. 6

TROUBLESHOOTING 1. Green LED in spout does not blink 2 seconds after battery installation. Battery placement incorrect or batteries have been discharged. Ensure alkaline batteries are installed properly. Check the orientation of each battery matches the positive (+) and negative (-) symbols shown on the battery compartment. 2. Faucet does not function. Capacitance cable not connected. Connect cable. 3. Faucet delivers water in an uncontrolled manner. Faucet is not working properly. Clean sensor window; if problem persists contact Sloan Tech Support (see below). 4. Faucet does not deliver any water when sensor is activated. Solenoid valve produces an audible CLICK. A. Water supply stop(s) closed. Open water supply stop(s). B. Strainer is clogged. Remove, clean, and reinstall strainer. Replace strainer (filter), if needed (refer to page 6) Solenoid valve DOES NOT produce an audible CLICK. A. Batteries low (battery powered models). Replace batteries (refer to battery replacement on page 5). B. Power failure (hardwire models). Check power supply. 5. Faucet delivers only a slow flow or dribble when sensor is activated. Water supply stop(s) are partially closed. Completely open water supply stop(s). 6. Faucet does not stop delivering water or continues to drip after user is no longer detected. Faucet is not working properly. Clean sensor window; if problem persists contact Sloan Tech Support (see below). 7. LED indicator blinks RED when faucet is in use. Batteries low (battery powered models). Replace batteries (refer to battery replacement on page 5). 8. The water temperature is too hot or too cold on a faucet connected to hot and cold water supply lines. A. Supply stops are not adjusted properly. Adjust supply stops. B. For models with integral side mixing valve Mixing valve is set improperly for the water temperature desired. Rotate mixing valve handle clockwise to decrease water temperature or counterclockwise to increase water temperature. C. Inadequate hot water supply. Adjust supply stops. LED DISPLAY DIAGNOSTIC CODES LED1 LED3 LED2 Function LED1 LED2 LED3 Notes Power Up Success (Battery Only Models) Power Up Success (Adapter Models) Low Battery Clean Mode Blinks 5x Blinks 1 every second (5 seconds); for battery power Blinks 3-5x Blinks 3-5x Blinks 1 every second (3-5 seconds); for adapter power Blinks 4x Blinks NOTE: LED1 (RED) and LED2 (GREEN) are for battery and programming related items. LED3 (RED) is for solenoid service. Battery power is low; During hand detection Once every 2 seconds; Touch faucet body more than 8 seconds, water hold for 2 minutes Water Hold Blinks Once every 1 second; If water turns on/off 5 times in 20 seconds, faucet turns off for 1 minute Solenoid Latch Failure Blinks Two RED LED blinks; After hand removed from detection zone Cap Sensor Fails to Calibrate Blinks 4 times per second; Before first water burst Detection for cable is not installed correctly Ambient Electrical Noise Too High Blinks 4 times per seconds; After first water burst CARE AND CLEANING DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean faucets that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom sink, protect the faucet from any splattering of cleaner. Acids and cleaning fluids will discolor or remove chrome plating. 7

PARTS LIST Item Part No. No. Description 1 EFX-2 Bowed Crown 2 EFX-36 Control Module Mounting Kit 3 EFX-8-A Battery Pack Assembly 4 EFX-13-A Solenoid Valve Caddy 0.5 gpm (1.9 Lpm) EFX-14-A Solenoid Valve Caddy 1.5 gpm (5.7 Lpm) 5 EFX-19 Filter / Strainers 6 EFX-1003-A Control Module Assembly 0.5 gpm (1.9 Lpm) EFX-1004-A Control Module Assembly with Turbine 0.5 gpm (1.9 Lpm) EFX-1005-A Control Module Assembly 1.5 gpm (5.7 Lpm) EFX-1006-A Control Module Assembly with Turbine 1.5 gpm (5.7 Lpm) 7 EFX-31 120 VAC/6.75 VDC Plug-in Voltage Adapter 8A EAF-1 Faucet Spout Mounting Kit (Pedestal) 8B EFX-21-A Faucet Spout Mounting Kit (Integrated Base) 9 EFX-20-A Base Plate for 4 Centerset Sink 10 EFX-26-A Base Plate for 8 Centerset Sink 11 MIX-60-A Below Deck Mechanical Mixing Valve 12 MIX-135-A Below Deck Thermostatic Mixing Valve 13 ETF-617-A Bak-Chek Tee 14 EFX-33 Inlet Hose Fitting 15 EFX-34 Flexible Supply Hose 18 (45 mm) 16 EFX-1002-A 0.5 gpm (1.9 Lpm) Multi-Lam Spray Insert (includes: insert, o-ring, removal tool, and 2.5 mm allen key) EFX-1001-A 1.5 gpm (5.7 Lpm) Aerated Stream Insert (includes: insert, o-ring, removal tool, and 2.5 mm allen key) EFX-1000-A 1.5 gpm (5.7 Lpm) Laminar Stream Insert (includes: insert, o-ring, removal tool, and 2.5 mm allen key) 17 EAF-23-A Splitter 18 EFX-24-A 11-13/16 (300 mm) Extension Cable EFX-25-A 47-1/4 (1200 mm) Extension Cable EFX-17-A 126 (3200 mm) Extension Cable 2 14 11 12 1 8B 15 7 9 8A 10 6 4 3 5 17 16 18 NOTE: If changing flow rate, caddy and spray insert must be changed in conjunction. 13 Manufactured by Sloan Valve Company under one or more of the following U.S. Patents: 7,690, 623; 7,069,941; 6,619,320. The information contained in this document is subject to change without notice. SLOAN 10500 SEYMOUR AVENUE FRANKLIN PARK, IL 60133 Phone: 1-800-9-VALVE-9 (1-800-982-5839) Fax: 1-800-447-8329 www.sloan.com Copyright 2016 SLOAN Code No. 0816407 Rev. 5 (05/16)