NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

Similar documents
LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

INSTALLATION INSTRUCTIONS SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM FLUSHOMETERS EXPOSED CLOSET, URINAL & SERVICE SINK INSTALLATIONS.

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS

Royal. Flushometers. Repair Parts and Maintenance Guide PARTS LIST ITEM 10A. SLIP JOINT GASKETS AND RINGS

Maintenance Guide. OPTIMA Components:

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS

Royal Flushometer PARTS LIST

Royal Flushometer. Manual Flushometers. Repair Parts and Maintenance Guide PARTS LIST

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

Aquaflush. Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6000 Z6003

INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS

G2 Optima Plus Flushometer

AquaVantage AV Z6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual

Aquaflush. Z6100 Series Aquaflush Concealed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6140

INSTALLATION INSTRUCTIONS FOR PISTON TYPE FLUSHOMETER EXPOSED CLOSET AND URINAL INSTALLATIONS

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

AquaSense ZTR Series

INSTALLATION INSTRUCTIONS for EXPOSED PULSAR FLUSH VALVES

Aquaflush Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual

AquaVantage AV ZER6100AV Series AquaVantage Concealed Flushometer Installation, Operation, Maintenance and Parts Manual

Installation Instructions

Installation Instructions

Installation Instructions

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

ETF-600 Sensor Operated Lavatory Faucet

Sloan Flushometer. Manual Flushometers. Repair Parts and Maintenance Guide PARTS LIST ITEM 6. SLIP JOINT GASKETS AND RINGS

Aquaflush Bedpan Washer Series Installation, Operation, Maintenance, and Parts Manual

AquaSense AV ZR Series Sensor-Operated, Battery-Powered Flushometer Installation, Operation, Maintenance and Parts Manual

AquaSense ZTR Series

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

INSTALLATION INSTRUCTIONS. Automatic Sensor Retrofit Kit For Urinals and Toilets ZERK-CP Chrome-Plated Cover ZERK-CPM Chrome-Plated Metal Cover

Installation Instructions

Installation Instructions

AquaSense AV ZER Series

Control Stop H-700-A 3/4 NPTF inlet for adjustable tail H-700-A 1 NPTF inlet for adjustable tail

Control Stop. H-710 Stop, chrome plated: Screwdriver Angle Stop with H-573-A Locking Vandal Resistant Cap

Installation Instructions

AquaSense AV ZER Series

Aquaflush Bedpan Washer Series Installation, Operation, Maintenance, and Parts Manual

Installation Instructions

Optima Flushometers Current style Royal (after 09/26/10)

AquaSense AV ZEMS-IS Series Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual

INSTALLATION INSTRUCTIONS for EXPOSED SENSOR-FLUSH FLUSH VALVES

AquaSense AV Closet ZEMS Series Automatic Systems Sensor-Operated AquaVantage Flushometer Installation, Operation, Maintenance, and Parts Manual

INSTALLATION INSTRUCTIONS FOR EXPOSED GEM 2 PISTON TYPE WATER CLOSET AND URINAL FLUSHOMETERS

Installation Instructions

Installation Instructions

AquaSense ZTR Series

Installation Instructions

Sensor-Operated Exposed Systems ZEMS6200 ZEMS ZEMS ZEMS6201 ZEMS6203

AquaSense TM ZEG Series

AquaSense TM ZTS6200EV Series

Installation Instructions

AquaVantage Z6000AV Series

Aquaflush Z6000 Series

AquaSense AV TM ZEMS Series

EcoVantage AV. ZRK Dual Flush Series. Sensor-Operated, Battery-Powered Retrofit Kit. Installation, Operation, Maintenance, and Parts Manual

AquaSense ZEMS G2 Series

INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS

Troubleshooting Guide HYBRIDFLUSH AEF-801 SERIES

Installation Instructions

TABLE OF CONTENTS Flushometer Section

AquaSense AV ZEMS-IS Series w/ HW6 Power Converter Automatic Sensor-Operated Exposed Flushometer Installation, Operation, Maintenance and Parts Manual

Section 3 FLUSHOMETER. Table of Contents. Phone Fax

Sloan & Zurn Flush Valves

Section 3 FLUSHOMETER. Table of Contents. Phone (650) Fax (650)

GENUINE REPAIR PARTS FOR

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL AND REGAL XL FLUSHOMETER

Installation Instructions

INSTALLATION INSTRUCTIONS FOR SLOAN SF ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

Model 8309WC Barrier Free Shower & Eye/Face Wash

Installation Instructions

Model 8309WC Barrier Free Shower & Eye/Face Wash

Installation and Owner s Manual HYBRIDFLUSH AEF-801 SERIES

Installation and Maintenance Instructions

Installation Instructions

FOR TECHNICAL ASSISTANCE

OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC)

Model 8317 Combination Shower Eye/Face Wash

Geberit Flushing Technologies Electronic and Manual Flush Valves

FIP 2 Outlet Angle Valve 3/8" V1-AB M2-AB006 3/8 IPS Escutcheon. M2-AB008 1/2" IPS CP Escutcheon. Hose Bibb Celecon V2-AB /4"

Installation Instructions

RSV16 Retro-Fit Cartridge Acorn Controls SV16 Valve Cartridge

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

Colt Series C400, C500

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

Model 0390 EZFILL TOP FILL MULTIFEED KIT WITH 1.32 GAL. (5L) CONTAINER EZFILL KIT* INSTALLATION AND MAINTENANCE GUIDE

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

INSTALLATION INSTRUCTIONS SINGLE, DOUBLE, TRIPLE AND QUADRUPLE STATION SENSOR OPERATED SOLID SURFACE AND BIO-DECK LAVATORY SYSTEMS ELC-41000

Model 8346/8346CRP Shower & Eye/Face Wash

INSTALLATION, OPERATING AND SERVICE MANUAL

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

Transcription:

NAVAL NAVAL I.I. Code No. 0816176 Rev. 1 INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS Certified Made in the U.S.A Exposed Closet Flushometer 1-1/2" Top Spud NAVAL 110/111 NAVAL 115 NAVAL 116 Exposed Urinal Flushometer 1-1/4" Top Spud NAVAL 180 Exposed Urinal Flushometer 3/4" Top Spud NAVAL 186 Exposed Closet Flushometer 1-1/2" Back Spud NAVAL 120 NAVAL 121 NAVAL 122 The Sloan Naval is a piston type Flushometer of superior design. It employs an exclusive Xpelor By-Pass Feature that ensures consistent metering operation even under the most severe water conditions. Navel Brass, Stainless Steel and High Grade Thermoplastics insure that vital inside parts will not be affected by corrosive water conditions. The Naval is especially suited for marine use, gray water systems or any other application where aggressive or corrosive water conditions would reduce the life and efficiency of an ordinary flushometer. The Naval Flushometer is designed for easy installation and maintenance and comes complete with a metal oscillating Non-Hold-Open lever actuator, Bak-Chek control stop, adjustable tailpiece (ground joint tailpiece available for salt water applications), vacuum breaker flush connection, spud coupling, and wall and spud flanges. The following instructions will serve as a guide when installing the Sloan Naval Flushometer. As always, good safety practices and care are recommended when installing your new Flushometer. If further assistance is required, contact your nearest Sloan Representative office. LIMITED WARRANTY Sloan Valve Company warrants its Naval Flushometer to be made of first class materials, free from defects of material or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years (1 year for special finishes) from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer s cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company s products directly from Sloan Valve Company for purpose of resale. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.

VALVE ROUGH-IN NAVAL 110 Water Saver, 3.5 gpf (13.2 Lpf) NAVAL 111 Low Consumption, 1.6 gpf (6.0 Lpf) NAVAL 115 & 116 Water Saver, 3.5 gpf (13.2 Lpf) NAVAL 115-1.6 & 116-1.6 Low Consumption, 1.6 gpf (6.0 Lpf) 1" I.P.S. 1" I.P.S. 11-1/2" (292 mm) (NAVAL 115) 24" (610 mm) (NAVAL 116) 27" (686 mm) C/L OF WASTE C/L OF WASTE FIN. WALL NAVAL 120, 121 & 122 Water Saver, 3.5 gpf (13.2 Lpf) NAVAL 120-1.6, 121-1.6 & 122-1.6 Low Consumption, 1.6 gpf (6.0 Lpf) NAVAL 180-1 Low Consumption, 1 gpf (3.8 Lpf) 1" I.P.S. 1" I.P.S. 11-1/2" (292 mm) (NAVAL 120) 11-1/2" (292 mm) (NAVAL 121) 16" (406 mm) (NAVAL 122) 24" (610 mm) 6-1/2" (165 mm) MIN. MODEL 186-1 Low Consumption, 1 gpf (3.8 Lpf) 11-1/2" (292 mm) 3/4" I.P.S. (20 mm DN) SUPPLY For Salt Water applications, Sloan Valve Company recommends furnishing Naval Valves with a Ground Joint Supply Stop. Specify -GJ (Ground Joint) variation. Salt Water and other non-potable water supplies typically do not require the use of vacuum breakers. To furnish the valves less the vacuum breaker, specify the -XYV variation. FLUSH VOLUMES NOTED ABOVE ARE FACTORY SET. VALVE FLUSH VOLUME ADJUSTMENT RANGE Urinal: Closet: 0.5 to 3 gpf (1.9 to 11.4 Lpf) 1.5 to 7 gpf (5.7 to 26.5 Lpf) Figure 1

PRIOR TO INSTALLATION Prior to installing the Sloan Navel Flushometer, install the items listed below as illustrated in Figure 1. Closet/urinal fixture Drain line Water supply line Important: ALL PLUMBING IS TO BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS. WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE. FLUSH ALL WATER LINES PRIOR TO INSTALLING FLUSHOMETER The Sloan Naval is designed to operate with 10 to 100 psi (69 to 689 kpa) of water pressure. THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED. Consult fixture manufacturer for minimum pressure requirements. Most Low Consumption water closets (1.6 gallon/6 liter) require a minimum flowing pressure of 25 psi (172 kpa). Protect the Chrome or Special finish of this flushometer DO NOT USE TOOTHED TOOLS TO INSTALL OR SERVICE THE VALVE. Also, see Care and Cleaning section of this manual. IMPORTANT: WITH THE EXCEPTION OF CONTROL STOP INLET, DO NOT USE PIPE SEALANT OR PLUMBING GREASE ON ANY VALVE COMPONENT OR! TOOLS REQUIRED FOR INSTALLATION Slotted screwdriver Sloan A-50 Super-Wrench or smooth jawed spud wrench INSTALLATION Step 1 - Control Stop Installation (Figure 2) Install the Sloan Bak-Chek Control Stop and Supply Flange to the water supply SET SCREW SUPPLY Figure 2 IRON PIPE NIPPLE OR COPPER PIPE WITH SWEAT SOLDER ADAPTER COVERING TUBE BAK-CHEK CONTROL STOP STOP CAP YBYC VARIATION SHOWN line with the outlet positioned as required. For Sweat Solder applications, see the following instructions & Figure 3: A. Measure distance from finished wall to centerline of Fixture Spud. Cut water supply pipe 1-1/4" (32 mm) shorter than this measurement. Chamfer O.D. and I.D. of water supply pipe. B. Slide Threaded Adapter onto water supply pipe until end of pipe rests against shoulder of Adapter. Sweat solder Adapter to water supply pipe. C. Determine length of Covering Tube by measuring distance from finished wall to the first thread of Adapter (dimension X in Figure 3). Cut Covering Tube to this length. D. Slide Covering Tube onto water supply pipe. Slide Wall Flange over Covering Tube until it rests against the finished wall. E. Install the Sloan Bak-Chek Control Stop to the water supply line with the Figure 3 outlet positioned as required. Step 2 - Install Vacuum Breaker Flush Connection (Figure 4) Slide the Spud Coupling, Nylon Slip Gasket, Rubber Gasket and Spud Flange over the Vacuum Breaker Tube and insert tube into Fixture Spud. Hand tighten Spud Coupling onto Fixture Spud. Note: On valves furnished less vacuum breaker, (XYV variation), connect flush MODEL 110/111 MODEL 113/115/116 MODEL 117 Figure 4 tube to the bottom of the valve using the slip gasket supplied. Step 3 - Install Flushometer SLOAN ADJUSTABLE TAILPIECE (Figure 5) The Sloan Adjustable Tailpiece compensates for off-center roughing-in on the job. Maximum adjustment is 1/2" (13 mm) IN or 1/2" (13 mm) OUT from the standard (centerline of Flushometer to centerline of Control Stop). If a ground joint tailpiece has been specified (recommended for seawater applications), there is no lateral adjustment; therefore, the NOTE: If roughing-in measurement exceeds 5-1/4" (133 mm), a longer tail may be supplied. Figure 5 WATER SUPPLY PIPE TUBE NYLON SLIP RUBBER X MODEL 120 MODEL 121 MODEL 122 NYLON SLIP ELBOW FLUSH CONNECTION RUBBER 1-1/4" (32 mm) MODEL 180 MODEL 186 4-1/4" (108 mm) MIN. 5-1/4" (133 mm) MAX. FINISHED WALL ADAPTER COVERING TUBE WALL TUBE NYLON SLIP RUBBER

rough-in must be exact. IMPORTANT: WITH THE EXCEPTION OF CONTROL STOP INLET, DO NOT USE PIPE SEALANT OR PLUMBING GREASE ON ANY VALVE COMPONENT OR! Sloan Adjustable Tailpiece Insert Adjustable Tailpiece into Control Stop. Wet O-ring seal with water to lubricate. Secure by hand tightening Tailpiece Coupling. Sloan Ground Joint Tailpiece Place end of tailpiece against control stop. Secure by hand tightening tailpiece coupling. All Flushometers Align Flushometer on top of Vacuum Breaker Flush Connection and secure by hand tightening Vacuum Breaker Coupling. Align Flushometer Body and securely tighten Tailpiece Coupling, Vacuum Breaker Coupling and Spud Coupling, respectively. Important Note: Use a Sloan A-50 Super -Wrench or smooth jawed spud wrench to secure all couplings. This will eliminate damage to chrome or HANDLE ASSEMBLY Figure 6 A-31 FLUSHOMETER BODY FLUSH CONNECTION TAILPIECE ADJUSTABLE TAILPIECE C/L FIXTURE O-RING G-44 FRICTION RING 4-3/4" (121 mm) CONTROL STOP C/L SUPPLY special finish that normally occurs when slip-joint pliers, pipe wrenches or other toothed tools are used. Step 4 - Flush Out Supply Line (Figure 7) Shut off Control Stop and remove Flushometer Cover. Lift out the Piston Assembly. Install Flushometer Cover wrench tight and open Control Stop. Turn on water supply to flush line of any debris or sediment. After completion, shut off Control Stop, remove Flushometer Cover and reinstall Piston Assembly. Install Flushometer Cover wrench tight. Open Control Stop and Figure 8 Step 6 - Volume Adjustment (Figure 9) The Sloan Naval Flushometer can be adjusted to meet the flushing requirements of any plumbing fixture. The flush volume (gallons per flush) may be increased or decreased by turning the adjustment screw located beneath the hex nut in the center of the cover. CLOCKWISE reduces flush volume COUNTERCLOCKWISE increases flush volume ADJUSTMENT RANGE: Urinal: 0.5 to 3 gpf (1.9 to 11.4 Lpf) Closet: 1.5 to 7 gpf (5.7 to 26.5 Lpf) Important: Many local plumbing codes prohibit adjustable Flushometers. For these applications, the Naval Flushometer can be supplied in a non-adjustable style. Figure 9 Figure 7 activate Flushometer Valve. Step 5 - Adjust Control Stop (Figure 8) Adjust Control Stop to meet the flow rate required for the proper cleansing of the fixture. Open Control Stop COUNTERCLOCKWISE l/2 turn from the closed position. Activate Flushometer. Adjust Control Stop after each flush until the rate of flow delivered properly cleanses the fixture. Important: The Sloan NAVAL Flushometer is engineered for quiet operation. Excessive water flow creates noise, while too little water flow may not satisfy the needs of the fixture. Proper adjustment is made when: 1. The plumbing fixture is cleansed after each flush without splashing water out from the lip. 2. A quiet flushing cycle is achieved. After adjustment: Wrench Tighten Control Stop Cap to Eliminate Vandalism. CARE AND CLEANING OF CHROME AND SPECIAL FINISHES DO NOT use abrasive or chemical cleaners to clean Flushometers as they may dull the luster and attack the chrome or special decorative finishes. Use ONLY soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom tile, the Flushometer should be protected from any splattering of cleaner. Acids and cleaning fluids can discolor or remove chrome plating.

TROUBLESHOOTING GUIDE I. Valve does not function. II. III. A. Control Stop or Main Valve is Closed. Open Control Stop or Main Valve. B. Handle Assembly is worn. Install Handle Repair Kit (B-50-A) or replace handle. Insufficient volume of water to adequately siphon fixture. A. Control Stop not open enough. Adjust Control Stop for desired delivery of water. B. Urinal or Shower Piston installed in a Closet Valve or older Blow Out Urinal. Replace Piston with proper Closet Piston (CN-1002-A). C. Regulating Screw (on top of valve) improperly set. Turn Regulating Screw counterclockwise to increase flush. VALVE FLUSH VOLUME ADJUSTMENT RANGE Urinal: 0.5 to 3 gpf (1.9 to 11.4 Lpf) Closet: 1.5 to 7 gpf (5.7 to 26.5 Lpf) D. Piston worn out. Repair or replace Piston. E. Inadequate volume or pressure at supply. If no gauges are available to properly measure supply pressure or volume of water at the Valve, then completely remove the entire Piston from the valve, reassemble cover and open Control Stop to allow water to pass through the empty Valve. If the supply is adequate to siphon the fixture, remove the Flow Ring from the bottom of the Piston to provide additional flow. If the supply is not adequate to siphon the fixture, steps should be taken to increase the pressure and/or supply. Length of flush too short (Short Flushing) or Valve closes off immediately. A. Regulating Screw not at a proper setting. Turn Regulating Screw counterclockwise to lengthen flush. B. Water passing by damaged or worn Piston Cup. Repair or replace Piston. C. Loose Piston Assembly or loose Top Plate Screw. Tighten Top Plate Screws. Screw Piston Body and Guide together (hand tighten ONLY - rubber Relief Valve Seat will distort if screwed too tight). D. Damaged or worn Piston Top Plate or Expelor. Repair or replace Piston. E. Urinal or Shower Piston installed in a Closet Valve or older Blow Out Urinal. Replace Piston with Closet Piston (CN-1002-A). IV. Length of flush too long (Long Flushing) or fails to close off. A. Regulating Screw not at proper setting. Turn Regulating Screw clockwise to shorten flush. B. Relief Valve in Piston is not seating properly due to wear or debris. Disassemble Piston Assembly and wash under running water. Repair or replace Piston if necessary. C. Bypass holes in Piston or Top Plate clogged or fouled with debris. Disassemble Piston Assembly and wash under running water. Repair or replace Piston if necessary. D. Closet Piston installed in Urinal Valve. Replace Piston with Urinal Piston (CN-1003-A). E. Line has dropped and is not sufficient to force Relief Valve to Seat. Shut off Control Stop until pressure has been restored, then reopen Stop. V. Water splashes from fixture. A. Supply volume is more than necessary. Adjust Control Stop to meet flow rate required for proper cleansing of the fixture. B. Lime or mineral accumulation on fixture vortex or spreader holes. Remove lime or mineral build-up in fixture. VI. Flush is not considered Quiet or makes noise at close off. A. Control Stop not properly adjusted. Adjust Control Stop to meet flow rate required for proper cleansing of the fixture. B. Worn, damaged or loose Main Seat. Replace Main Seat. C. Worn Piston. Repair or replace Piston. VII. Leaking at Handle Assembly. A. The B-39 Handle Seal may be deteriorated. Install new B-39 Handle Seal. NOTE: The B-39 Seal will easily slide onto the Bushing if it is wet. B. Handle Gasket has been omitted. Install A-31 Handle Gasket or Handle Repair Kit (B-50-A). C. Valve Handle Bushing is worn. Install Handle Repair Kit (B-50-A). Refer to the Naval Flushometer Maintenance Guide for additional Troubleshooting and Repair Part information. If further assistance is required, please contact the Sloan Valve Company Installation Engineering Department at 847/671-4300.

PARTS LIST 8 7 3 1 2 4A 4D 4B 4C 5 6A 6A 6B 6C Item Part Description No. No. 1 Valve Assembly 2 B-32-A Handle Assembly 3 H-710-A Bak-Chek Control Stop 4A V-500-AA 1-1/2" (38 mm) x 9" (229 mm) Vacuum Breaker Assembly CP (Model 110) V-500-AA 1-1/2" (38 mm) x 21" (533 mm) Vacuum Breaker Assembly CP (Model 115) V-500-AA 1-1/2" (38 mm) x 24" (610 mm) Vacuum Breaker Assembly CP (Model 116) 4B V-500-AA 1-1/4" (32 mm) x 9" (229 mm) Vacuum Breaker Assembly CP (Model 180) 4C V-500-AA 3/4" (19 mm) x 9" (229 mm) Vacuum Breaker Assembly CP (Model 186) 4D V-500-A 1-1/2" (38 mm) Vacuum Breaker Assembly CP 5 F-109 1-1/2" (38 mm) Elbow Flush Connection CP 6A F-5-A 1-1/2" (38 mm) Spud Coupling Assembly (Models 110, 115, 116, 120, 121 and 122) 6B F-5-A 1-1/4" (32 mm) Spud Coupling Assembly (Model 180) 6C F-5-A 3/4" (19 mm) Spud Coupling Assembly (Model 186) 7 F-7 Supply Flange (Supplied When Valve is Not Ordered with Sweat Solder Kit) 8 H-633-AA 1" (25 mm) Sweat Solder Kit with Cast Set Screw Flange ( YBYC Variation) H-636-AA 3/4" (19 mm) Sweat Solder Kit with Cast Set Screw Flange ( YBYC Variation) Part number varies with valve model variation; consult factory. Refer to the Naval Flushometer Maintenance and Repair Guide for a complete listing of Naval Components and Repair Kits. NOTICE The information contained in this document is subject to change without notice. 10500 SEYMOUR AVE. - FRANKLIN PARK, IL 60131 PHONE: 1-800-9-VALVE-9 - FAX: 1-800-447-8329 http://www.sloanvalve.com 11170 SW 5TH STREET, SUITE 100 - BEAVERTON, OR 97005 PHONE: 1-800-440-5556 - FAX: 1-503-643-8224 http://www.airdelights.com - Customer_Service@AirDelights.com