Directional Control Valve Series D3W Soft Shift

Similar documents
Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series D1VW

Directional Control Valve

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Chapter 2: Directional Control Valves

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Pilot-Operated Proportional DC Valve Series D*1FH

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT

Directional Seat Valve Series D4S (Denison)

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison)

Proportional Pressure Relief Valve Series RE*T

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Chapter 6: Check Valves

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction

Proportional Directional Control Valves Series D*1FE. General Description. Features. D41FE Standard

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

DIRECTIONAL CONTROL VALVES CETOP3

Chapter 6: Check Valves

DIRECTIONAL CONTROL VALVES CETOP3

Chapter 7: Sandwich Valves

Explosion-Proof Valves. According to Directive 94/9/EC (ATEX) and IECEx Requirements

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

General Specifications DRV DRV-Exm DRV-Exd

Chapter 5: Flow Valves

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

Proportional Directional Control Valves Series D*1FB. General Description. Features D91FB OBE

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min

Chapter 10: Valves for Pipe Mounting

Throttle Check Valve Series FM

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve

4/3, 4/2 proportional directional valves solenoid operated (for open loop control)

Introduction. Pressure drops

Series PD directly operated solenoid valves

D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 41

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Seated valves 500 bar

DSH* /117 ED LEVER OPERATED DIRECTIONAL CONTROL VALVE MOUNTING SURFACES DSH3 ISO DSH5 ISO

Q max (see specifications table)

DIRECTIONAL CONTROL VALVES CETOP 3/NG6

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

Cartridge Valves Technical Information Directional Valves DCV 03

NG06. General Size NG6 NG10 Design

Chapter 3: Proportional DC Valves

Series PD directly operated solenoid valves

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Seated valves. Type WV700 NG 6 ISO up to 25 l/min, up to 700 bar. Features. Applications. Design. Technical data

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Directional Control Valves. General Description. Features. Specifications

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

RPEW4-06. Functional Description HA /2005. Solenoid Operated Directional Control Valves with Wirebox 1/2 NPT 1/2 NPT. Replaces HA /2004

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

Chapter 3: Proportional DC Valves

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Type of operation Depending on requirement either one or two dry DC-solenoid,

PRM2-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013. Size 06 p max 350 bar Q max 40 L/min

6/2 WAY DIRECTIONAL VALVE KV (NG 6)

4/3-4/2 Directional valve with solenoid actuation

DIRECTIONAL CONTROL VALVE SOLENOID OPERATED TYPE HD3-ES-*-/10 CETOP MPa HD3 - ES - (1) (C) - * - (024C) (-) / 10

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002

EV FT3 ES-FT5 ES/GB :09 Pagina 4 FT3 ES* 4

Series P directly operated solenoid valves

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Directional Controls

Chapter 5: Flow Valves

DS5JB /110 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE. Q max 32 GPM ALTERNATING CURRENT SERIES 10

Servo solenoid valves with on-board electronics (OBE)

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Proportional Throttle Valves Series TDL

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198

MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Proportional pressure relief valve

3/2-way Solenoid Valve for pneumatics

Remote Process Actuation Control System AirLINE - Siemens ET 200S

LOGIC ELEMENTS SERIES 10 LC* LP* /103 ED CARTRIDGE VALVES ISO DIN COVERS FOR CARTRIDGE VALVES ND

APPLICATION OF SYSTEM 8

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Miniature coil (3W) encapsulated in synthetic material. Connection with 3-pin DIN type B plug. Degree of protection IP 65.

Servo solenoid valves with on-board electronics (OBE)

High Pressure Valves

ADB.3... DIRECTIONAL CONTROL

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

3/2 Solenoid Cartridge Valve, Size 6

Transcription:

Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this valve is achieved by damping the plunger in the tube with an orifice. Orifice in plunger Technical data General Design Directional spool valve Actuation Solenoid Size DIN NG10 / CETOP 05 / NFPA D05 Mounting interface DIN 4340 A10 / ISO 4401 / CETOP RP 11-H / NFPA D05 Mounting position Unrestricted, preferably horizontal Ambient temperature [ C] -5...+50 Weight [kg] 4.8 (1 solenoid), 6.3 ( solenoids) Hydraulic Max. operating pressure [bar] P, A B: 350 T: 10 (DC) Fluid Hydraulic oil in accordance with DIN 5154 / 5155 Fluid temperature [ C] -5... +70 Viscosity permitted [mm²/s].8...400 (.8...400 cst) Viscosity recommended [mm²/s] 30...80 Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) Flow max. [l/min] 150 (DC) Leakage at 50 bar [ml/min] Up to 0 per flow path, depending on spool Static / Dynamic Step response at 95% [ms] See table response time Electrical characteristics Duty ratio 100% ED; CAUTION: coil temperature up to 150 C possible Protection class IP 65 in accordance with DIN 40050 (plugged and mounted) Code K J U G Supply voltage / ripple [V] 1 VDC 4 VDC 98 VDC 05 VDC Tolerance supply voltage [%] ±10 ±10 ±10 ±10 Current consumption hold [A] 3 1.5 0.37 0.18 Power consumption hold [W] 36 36 36 36 Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461. Wiring min. [mm²] 3 x 1.5 recommended Wiring length max. [m] 50 recommended With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. -47

Ordering Code D 3 W Directional control valve Size DIN NG 10 CETOP 5 NFPA D05 3-chamber valve Wet pin armature solenoid, threaded in tube Spool type Style Seals Code N V Seals NBR FPM -48

Ordering Code W Solenoid voltage Solenoid connection Connector as per EN 175301-803, without plug Please order plug separately. See chapter, Accessories Manual override option Shift response option Design series Not required for ordering Code S4 S7 Shift response Orifice diameter 1.0 mm Orifice diameter 1.75 mm Code Manual override omit T With manual override Without manual override Code Voltage K 1V= J 4V= U* 98V= G* 05V= * For AC voltage use plug with rectifier. Please order rectifier plug separately. Further spool types, styles and voltages on request. -49

Flow Curve The flow curve diagram shows the flow versus pressure drop curves for all spools shown. To read the values in the diagram, the curve number for the selected spool and desired operating position must first be determined from the table below. Position "b" Position "a" Position "0" Spool P->A B->T P->B A->T P->A P->B A->T B->T P->T A->B 1 4 3 4 3 - - - - - - 4 1 4 1 3 3 1 1 5 1 3 4 3 5 - - 4 - - - 4 4 4 - - 3 3-5 5 4 3 5 3 5 - - - - - 6 4 3 4 3 6 6 - - - 6 7 5 1 4 3-4 - 6-10 4-4 - - - - - - - 11 4 3 4 3 - - 8 8 - - 1 4 3 4 3 7 7 7 7 8 8 14 4 3 5 1 4 - - 6-15 5 4 3 - - - 4 - - 16 5 3 4 3-5 - - - - 0 4 3 4 3 - - - - - - 6 4-4 - - - - - - - 30 4 4 - - - - - - P->B A->T P->A B->T P->A P->B A->T B->T P->T A-> B 8 4 3 4 3 - - - - 6-9 4 4 4 4 - - - - 6 - Position "b" Position "a" P->A P->B A->B P->B A->T 1 5 4 6 3 3 P->A B->T P->A P->B A->B 3 3 4 5 6 Flow curve Pressure drop [bar] Flow [l/min] -50

Shift Limits / Response Times Shift limits The diagram below specifies the shift limits for valves with DC solenoids. Valves of style F and M may only be loaded at 70% of the value. The specifications apply to a viscosity of 35 mm /s and equal flow at A and B port. These values can be considerably lower than the represented ones by unequal flow at A and B port. To avoid flow rates above the shift limits of the valve, a plug-in orifice can be inserted in the P port. Supply pressure [bar] Measured at 90% U nom and warm solenoids. Flow [l/min] Response times D3W Soft Shift Code Orifice size Energize Deenergize S4 1.0 mm 30 ms 550 ms S7 1.75 mm 160 ms 370 ms Step response times were obtained under the following conditions: υ = 35 mm /s at 50 C with the valve operating at 175 bar and 65 l/min. Published response times are nominal and may vary with spool, flow, pressure and temperature. Acceleration for different orifice sizes (archived against a valve without soft shift) Acceleration Standard 100% app. 70% Soft shift S7 app. 40% Soft shift S4 Operation by solenoid Standard 100% app. 60% Soft shift S7 app. 30% Soft shift S4 Operation by spring For even softer shifting, the proportional spools 81, 8, 101 and 10 can be used. -51

Dimensions Interface EN 175301-803, DC-solenoid B, E, F -style H, K, M -style C, D -style Ø6.5 Ø6.5 Ø6.5 Surface finish BK385 4x M6x40 11 Nm ± 15% NBR: SK-D3W-30 DIN 91 1.9 FPM: SK-D3W-V30 The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm. -5