UNITECH makes the indication and control of Process Parameters

Similar documents
Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Analog input module. Brief description. Page 1/8. Data Sheet

Module Type Controller SRX Temperature Control Module [Basic Type] X-TIO-A Instruction Manual

Micro Controller based Motor Protection Relay & Motor Management System

Description. functions including single duct pressure dependent or pressure independent systems.

INTECH Micro 2300-RTD6

35 35A 50 50A 1 Single phase. Solid state power controller

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

INTERNATIONAL METAL ENGINEERING

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

Turbidity and Suspended Solids Transmitter

Module Type Controller SRX Temperature Control Module for PROFIBUS X-TIO-G Instruction Manual

F-1500 SERIES INSERTION TURBINE FLOW METER

Fuji Electric s Latest High Functionality Temperature Controllers PXH, PXG and PXR, and Examples of their Application

BAPI-Stat 3 Room Sensor

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Power Switching Devices

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

mass flowmeter for compressed air

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Range of Ultrasonic Flowmeters.

Installation. Global Vision Inc Jefferson Hwy - Osseo, MN USA - ph fx

UNIVERSAL CALIBRATOR M

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

QUANTUM LX CONTROL PANEL

Operating manual. ph / mv controller type M8832N

GE Energy. The Becker * DNGP: Fail-Safe Protection for Your Gas Pipeline

USERS MANUAL MCD REMOTE OPERATOR

SAFETY PRECAUTIONS (Always read these precautions prior to use.)

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Model Q45H/ Residual Chlorine Monitor...

HIGH POWER SOLENOID DRIVER 1

NC State University Design and Construction Guidelines Division 23 Energy Management

HUMIDITY / TEMPERATURE TRANSMITTER

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

MagFlux Q 8200 Series

Optidew Vision Optical Dew-Point Meter

TTM MODEL TTM TRANSFORMER TEMPERATURE MONITOR AND COOLING CONTROL SYSTEM. BCI Bulletin BCI-TTM-01 Revision 12/03/02

EM DC Multi-Function DC Energy Meter

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

Process controller. for pneumatic and electric actuators. Process controller V. Process controller

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

MATRIX LLC LEVEL CONTROL PANEL

F-2700 SERIES INSERTION VORTEX FLOW METER

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

GS2 Series - Introduction

FX2N-2LC SPECIAL FUNCTION BLOCK

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

Quick Start Guide of CV50- ControlVIT Series

Digital Time Switches

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

CLA-VAL CPC Position Control 4-20 ma

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Harris IRT Enterprises Digital Resistance Tester Model XP

Paddle-wheel flow controller for On/Off control

PKS-FD Servo System

Magellan Utility Scale Energy Storage

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

RMF SYSTEMS CONDITION MONITORING CENTER PURE POWER

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

ProMinent S i g m a / 3 Motor Diaphragm Metering Pumps

2100 Turbine Flow Sensor

KNC-PKS-FD S-AAK-DKH

MULTI LANGUAGE KEYPAD

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

1/16 DIN Temperature Controller E5CS

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Low Profile Insertion Vortex

Industrial furnaces. Innovative solutions for your success

Flow meter Type Recordall (RCDL)

MIDDLE LOAD RELAY FOR SMART J/B

Superstatic 440. Static Heat- and Cooling Meter. Application

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Smart Series CSS & CSS-30-02

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

Paddle-wheel flow controller for On/Off control

INSTRUMENTS & TECHNOLOGY

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Energetic independence

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

Digital ph transmitter

MIC4 IGNITION CONTROLLER

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

Transcription:

T e c h n i c a l M a n u a l UT1596/UT1572/UT1584/UT1548 PID CONTROLLERS OUT AT AL1 AL2 0% 20 40 60 80 A/M OUT AT AL1 AL2 100% OUT OFF AT AL1 AL2 OUT OFF AT AL1 AL2 Model :UT 1144 Model :UT 1149 Model :UT 1177 Model :UT 1196 UNITECH makes the indication and control of Process Parameters Sure for service with hiend Universal Technology Add.78/Z/3, GIDC Makrpura, Makarpura, Vadodara390010. Ph : +91 7046223333 Sales: +91 94273 01436 Website: www.utplindia.in Email : sales@utplindia.in

AL1 AL2 DIGITAL PID CONTROLLERS UNITECH UT 1596/1572/1584/1548 INSTRUCTION MANUAL Specification Overview The UT 15 Series are microprocessorbased controllers designed with a high degree of functionality and reliability at a competitive price. The controllers are OUT AT AL1 AL2 0% 20 40 60 80 100% A/M OUT AT OUT OFF AT AL1 AL2 OUT OFF AT AL1 AL2 available in different formats: 48x48, Model :UT 1144 Model :UT 1584 Model :UT 1177 72x72, 96x96 This controller series is Model :UT 1596 Ideal for the control of temperature, Humidity, pressure, flow etc. in a variety of applications including: Dual Display and Bar graph Two large 4 digits display, SP and IP65 Front Face Protection IP65 rated front face permits use in Plastic Processing Industries configuration parameters. One 10 LED applications where it may be subjected to Packaging Machinery bargraph displays the control output moisture, dust conditions. Painting and coating Plants (MV), and up to 8 LEDs display the status Remote Setpoint Capability Semiconductor packaging / Testing of the different outputs (Control, Alarm, The setpoint can be defined from a Industrial Dryers ) and also provide indication of the remote PLC or other controller. Easy to Operate Features Different configuration levels provide easy access to parameters. Various Control Programming Several different algorithms are available as follows: PID or ON/OFF Control Heat/Cool Control with 2 PID sets Motor Position Control (without slidewire feedback) And many more... AutoTuning Capability Advanced autotuning function calculates the optimized PID values for your specific control system. Auto/Manual and programmer states. Setpoint Programming Two programs are available with a maximum of 8 segments. The 2 programs can be linked together and perform as a single 16 segment program. Extended Alarm Capability Up to three different alarm outputs are available per instrument and 17 kinds of event modes can be assigned to each of alarm output. Communications RS232 or RS485 (with ASC II & Modbus RTU Protocol) is optionally available with a maximum communication speed of 38400 bps. Parameter Lock A 4digit security code prevents any unauthorized changes of parameters or configurations. Parameters can be hidden to user to prevent any misconfiguration of the unit.

External Dimensions Mounting Procedure Mounting Cautions : (1) Use this instrument within the following ambient temperature and ambient humidity. Allowable ambient temperature: 0 to 50 C Allowable ambient humidity: 45 to 85% RH (2) Avoid the following when selecting the mounting location. Rapid changes in ambient temperature which may cause condensations. Corrosive or inflammable gases. Direct vibration or shock to the mainframe. Water, oil, chemicals, vapour or steam splashes. Excessive induction noise, static electricity, magnetic fields or noise. Direct air flow from an air conditioner. Exposure to direct sunlight. Excessive heat accumulation.

Specifications General Rated power supply voltage 85 to 265V AC, Frequency : 50/60Hz 22 to 26V AC, Frequency : 50/60Hz (Rating : 24VAC) 22 to 26V DC (Rating : 24VDC) Power Consumption 5VA Max (at 24V AC) 160mA max (at 24VDC) 7VA Max (at 100V AC) 10 VA max (at 240V AC) Insulation Resistance OVER 10MΩ UNDER DC500V megger between Input terminal and Case(Ground). OVER 10MΩ UNDER DC500V megger between Output terminal and Case(Ground). Standard Ambient Temp.. 25 + 2 C Conditions AmbientHumi. Rated Power Supply Power Frequency 55±5%RH 230V AC, 24V AC, 24VDC 50 ± 1Hz o± 60 ± 1HZ Operating Ambient Temp. 0 to 50 C Conditions Ambient Humi. Rated Power Supply Allowable Power Supply Power Frequency 20 to 90%RH (noncondensing) 85 to 265V AC 22 to 26V DC 85 to 265V AC 22 to 26VDC 50 ± 2Hz o± 60 ± 2Hz Transportation and storage Ambient Temp. Ambient Humi. 20 to +65 C 10 to +95% RH (noncondensing) conditions Vibration Resistance 20m/s 2 (Approx.2G),10to55Hzfor2hourseachinX,Y,Zdirections Exterior Mounting Case and front panel : plastic Panelmount Model UT1548 UT1584 UT1572 UT1596 Exterior Size (unit: :WXHXD mm ) inch 50X50X97 (1.97X1.97X 3.82) 50X96X97 (1.97X3.78X3.82) 74X74X97 (2.91X2.91X3.82) 96X96X97 (3.78X3.78X3.82) Panel Cutout (unit: :WXH mm ) inch 44.5 X 44.5 (1.75 X 1.75) 44.5 X 90.5 (1.75 X 3.56) 68.5 X 68.5 (2.97 X 2.97) 90.5 X 90.5 (3.56 X 3.56)

1. Specifications Input/Output Analog Input 1 Number of Point Type Note : Sampling cycle Indication Accuracy 1 point (TC, RTD or Linear) TC: RTD : K,J,R,S,B,E, T Pt100 Linear : 4~20mA / 2~10V DC (500Ω Resistance connected Across) Refer to Table A. For input Type symbols and Ranges. 250 ms 0~20mA / 0~10V DC (500Ω ± 0.2% FS ± 1digit (for details Table11) Resistance connected Across) Cold accuracy junction ±1.0ºC (under standard conditions) Input bias (offset) Digital Filter LSPL ~ USPL 0 200 sec (0: filter off) Decimal Point 0000, 000.0, 00.00, 0.000 Output Alarm Output Relay Contact Output : 250V AC, 3A (Resistive Load) Control Output Relay Contact Output : 250V AC, 3A (Resistive Load) Voltage Pulse 0/12V DC. (Load Resistance 600 Ω or More) Current Output 4 to 20mA DC. (Load Resistance 500 Ω or Less) Trigger Output (For TRIAC Driving) 100A or LessCurrent Output 2. Mounting Mounting Cautions : (1) Use this instrument within the following ambient temperature and ambient humidity. Allowable ambient temperature: 0 to 50 C Allowable ambient humidity: 45 to 85% RH (2) Avoid the following when selecting the mounting location. Rapid changes in ambient temperature which may cause condensations. Corrosive or inflammable gases. Direct vibration or shock to the mainframe. Water, oil, chemicals, vapour or steam splashes. Excessive induction noise, static electricity, magnetic fields or noise. Direct air flow from an air conditioner. Exposure to direct sunlight. Excessive heat accumulation.

V, ma, Current Voltage for SSR OUT: Relay Mounting Procedures (1) Prepare the panel cutout as specified in 2.2 Dimensions. (2) Insert the instrument through the panel cutout. (3) Insert the mounting bracket into the mounting groove of the instrument. (As Fig.1) (4) Pull till chick sounds to the direction shown by the arrow. (As Fig.2) (5) The other mounting bracket should be installed the same way described in 3.To 4. 3. WIRING Wiring Cautions : (1) For thermocouple input, use the specified compensation wire. (2) For RTD input, use leads with low resistance and having no resistance differences among the 3 leads. (3) Conduct input signal wiring away from instrument power, electric equipment power and load lines to avoid noise induction. (4) Conduct instrument power wiring so as not to be influenced by noise from the electric equipment power. If the instrument may be affected by external noise, a noise filter should be used. * shorten the distance between twisted power supply wire pitches. The shorter the distance between the pitches, the more effective for noise reduction. * Install the noise filter on the panel which is always grounded and minimize the wiring distance between the noise filter output side and the instrument power terminals. * Do not install fuses and/or switches on the filter output signal since this may lessen filter effect. (5) For wiring, use wires conforming to the domestic standard of each country. (6) About 4 to 5 seconds is required as the preparation time for contact output after power on. Use the delay relay when the output line is used for an external interlock circuit. (7) This instrument has no power supply switch nor fuses. Therefore, install the fuse close to the instrument and the switch, if required. * Recommended fuse rating: Rated voltage; 250 V Rated current; 1A * Fuse type; Timelag fuse (8) Do not excessively tighten the terminal screws. In addition, use the solder less terminal appropriate to the screw size. (9) To the instrument with power supply of 24V, please be sure to supply the power from SELV circuit Terminal Configuration : (1) All the under hookups are only for reference. (2) For wiring, please according to the hookup label which was glued on the plastic case of controller. 1 2 UT1584 & UT1596 L AC 85~265V AL 2 N C 11 12 1 2 AL 1 3 UT1548 L AC 85~265V N AL 2 11 VDC + 12 OUT: Relay DC420mA 4 5 + + 420mA OR 020mA RTD A B TC B + 6 7 8 9 10 1 L AC 85~265V 2 N AL 1 3 4 5 6 7 NC C + UT1572 8 9 10 + VDC 11 420mA OR RTD 12 020mA A B 13 TC B 14 + AL 2 C NC + OUT: Relay DC420mA 3 4 + + AL 1 5 6 7 VDC 8 9 + TC 10 RTD A B B + 420mA OR 020mA NC 13 14 15 16 17 18 19 20

4. FRONT DESCRIPTION 5. SETTING

6. PID Autotuning (AT) Function 7. Error Display 8. Input Range Table

TES : Sure for service with hiend Universal Technology Add.78/Z/3, GIDC Makrpura, Makarpura, Vadodara390010. Ph : +91 7046223333 Sales: +91 94273 01436 Website: www.utplindia.in Email : sales@utplindia.in

AL1 AL2 COM CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 UNITECH Sure for service with hiend universal technology Manufacturers of process Controls Instruments Process automaton (PLCs,HMI, SCADA,servo,drives) Instruments calibration ( ARC/AMC/validation ) Manufacturers of process Controls Instruments SMART CLEAN ROOM INDICATOR FLOW RATE122.65 TOT 12345678.25 FLOW RATE122.65 TOT 12345678.25 UNITECH AL1 AL2 AL3 AL4 COM TEMP. PRES. S.F./R.F. TEMP. PRES. SF/RF Www.unitechinstrument.com TEMPRETURE+RH Temp. Sensor and temp.2 wire transmitter Single channel universal indicator controller Dual channel universal indicator controller Multy channel temp indicator(4,8,12,16,20) PID and PROFILE controller Temp. Scanner with software (4,,8,12,16,20) data logger with pc software (4,8,12,16,20) Temp.+Rh transmitter (sensor) Temp.+Rh indicator cum controller Humidity sensor/ indicator/ controller SCADA SOFTWARE This software gives you access to real time process parameters in numeric and graphical form. It is a preengineered software package that provides all benefits of on line data logging and trending, the software can interface with multiple scanners, indicator.pid,plc,and data acquisitions systems using. multidrop Rs485 communication. With the feature of historical data logging function the entire precess history can be recorded for future analysis or validation. LEVEL Flow Metering Systems(volume / mass) PRESSURE FLOW Flow : Rate/Totlizer/Comuper/Batch Orifice Flow Meter ((NG) gas / steam) Steam Flow meter Flow indi.& Cont. (420 ma & frequency) Flow indicator & Totalizers (universali/p) Natural gas & standard gas Flow meter Batch indicator cum controller Thermel Dispenser Air Flow Meter Natural Gas flow computer (as per AGA3) Magnetic Flow Meter (water) On line temp.& Pressure compensation) Ultrasonic Flow Meter Steam flow computer (saturated &superheated) Low cost ½ & 1 Air/Gas Flow meter On line temp.& Pressure compensation) SCADA software (Online and Offline Report / Trend / part lading ) for flow analysis CLEAN ROOM/HVAC /PHARMA Temp. & pressure & vacuum & magnehelic gauge Diffrancial pressure swich and sensor PH sensor indicator(on line & table top ) Temp.+humidity transmitter Synchronized Digital Clocks / masters and slaves FLP temp indicator & contr. FLP temp scanner and data loggers with software AHU control panel with SCADA Temp.+humidity indicator Controller. Conductivity sensor indicator Temp.+RH +dp clean room indicator with sensor Control valve (on/off & modulating) We can gives all instruments in SS or flame proof panels and box Isolator /convertor High pressurizes tank level indication sys. Differantial pressure type level indicator. Ultrasonic level transmitter & controller Conductivity level transmitter & contr. Water Level Control systems. Level Switch/Sensor. Single/Dual channel indicator contr. Pressure & vacuum transmitter Differantial Pressure transmitter Hi accurate digital pressure gauge. Loop power indicator (PT/DP) I to P / E to P convertor. Universal input Signal isolator & convertor & multiplexer Multi channel Signal isolator & convertor & multiplexer Loop powered Signal isolator & square root extractors Equations computation modual & Linearization modual Convertor Load cell to ma MV to ma AC V to ma Ohms to ma/v Amp. to ma DC V to ma Sensor JUMBO DISPLAY OTHERES Temprature Humidity Photo sensor Pressure Vacuum Thayrister Gas Proxi Ssr Procces value big indicator Display size : 2,4,6,8,12 Clocks with date and years Production monitoring systems RPM/MPM indicator controller Alarm annunciator(2 to 200 chnl.) Auto manual station Manual loaders & celebrators We can provide GSM mobile comm. and modbus RTU 232/485 connectivity with pc software in our entire product range. We provide SCADA software (Online and Offline Report / Trend / part lading ) for flow analysis and data logging systems. We can provide our all instruments in MS or SS panel and also provide in flame proof and weather proof housing. We can accept to make customized instruments & trucky systems (hardware and computer software) as per customers needs. industrials procces automaton Total solution provider for Industrials Automaton PLC and HMI and hi speed communications module. SCADA system (standard and customized computer software) Servo Motors & Drives & AC drives / inverter Unitech Technocrats Pvt. Ltd. 78/1/Z/3, Makarpura GIDC, Makarpura, Vadodra390010,Gujarat,India Phone.: 02656623551 / 7046223333 Email :salse@utplindia.in,kuntal_unitech@yahoo.com URL :www.utplindia.in, cell no :094273 01436 Vibration sensors indicators Gas starilizers control systems Bagging controller (cements) Control valves and positioners