Diaphragm Valves Type 15

Similar documents
Diaphragm Valve Type 72

Swing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

3-Way Ball Valve Type 23H

Butterfly Valve Type 58 (PDCPD)

Butterfly Valves ASAHI AV VALVES

Butterfly Valve Type 57P

Sediment strainer (Type Y)

Constant Flow Valves ASAHI AV VALVES H-V019-E-6. Contents. Serial No. User s Manual

Rotary Damper. Type 57: 40~350mm (1 1/2 ~14 ) Type 56: 400mm (16 ) Type 75: 450~600mm (18 ~24 ) Contents

Contents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

contents (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 User s Manual

Air Release Valve (PDCPD) Air Release Valve for Water (PDCPD + Epoxy Resin Coating) User s manual. Air Release Valve. Air Release Valve for Water

Butterfly_Valve_Type57P

Diaphragm Valve Type 14 Pneumatic Actuated Type AV

Ball Valve Type 21 21α Nominal size mm (1/2-4 )

Diaphragm Valve Type 14 Pneumatic Actuated Type AP. User s Manual. Contents H-A065-E. Serial No.

Rotary Damper Pneumatic Actuated Type TA

Rotary Damper Electric Actuated Type S

Diaphragm Valves Type 14 True Union Diaphragm Valves Type14

Butterfly Valves Pneumatic Actuated Type TA Type TW

3-Way Ball Valve Type23 Pneumatic Actuated Type TA

Diaphragm Valve Type 14 Pneumatic Model Type AV

Diaphragm Valve True Union Diaphragm Valve Pneumatic Actuated Type AI

Pneumatic Actuated Type AA

Ball Valve Type Pneumatic Actuated Type TA

Diaphragm Valve Type 16 (Pneumatic Model Type AD)

3-Way Ball Valve Type 23 Electric Actuated Type T

3-Way Ball Valve Type23 Pneumatic Actuated Type AR. User s Manual. 15~50mm(1/2-2 ) Contents. Installation, Operation and Maintenance Manual

User s Manual. Compact Ball Valve Type27 Pneumatic Actuated Type AR mm (3/8-2 ) Contents. Installation, Operation and Maintenance Manual

Pneumatic Actuated Type AR. User s Manual. 15~50mm(1/2-2 ) Contents. Installation, Operation and Maintenance Manual

Pneumatic Actuated Type AR. User s Manual. 15~50mm(1/2-2 ) Contents. Installation, Operation and Maintenance Manual

Mounting and operating instructions EB 8093 EN. Series 240 Pneumatic Control Valve for Cryogenic Temperatures. Type and

Butterfly valves Figure 56 Installation & Maintenance Instructions

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

INSTALLATION & MAINTENANCE MANUAL

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

WARNING Carefully Read These Instructions Before Use

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

Installation, Operation, and Maintenance Manual

Danfoss Butterfly Valve

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

Crispin Valves Operating Guide. Crispin

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

Series 250 Pneumatic Control Valves Type and

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

OM Weir-Type Diaphragm Control Valve Model : VDD User s Manual

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Disc Brake System ( For Cross-Country)

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES

PNEUMATIC SLIDING VALVE

TBV OPERATION AND MAINTENANCE MANUAL SERIES 1800: FLANGED BALL VALVE. For technical questions, please contact the following:

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

3M TM Filter Housing 1BS-T/1BS-TW Series

Operating & Maintenance Manual For Steam Conditioning Valve

[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No:

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

Installation, Operation, and Maintenance Manual

WATERFLUX 3070 Quick Start

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

KEYSTONE. Butterfly valves Figure 9 Installation & Maintenance Instructions. Please read these instructions carefully

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

Operation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves

Installation, Operation, and Maintenance Manual

IOM-CleanFLOW TM. CleanFLOW Series Ball Valves. SV F Flow Controls I N C O R P O R A T E D

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Series 2200/2220 Control Valve. Operation and Maintenance SCOPE OF MANUAL MAINTENANCE DESCRIPTION VALVE INSTALLATION

Surplussing Valve SP-COSR-16

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

V-SEGMENT SERIES V-Port Segment Control Valves (VS/VV/VM) Installation & Maintenance Manual

Pressure relief valve

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves

Voltmaster Centrifugal Trash Pumps

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual

Installation and Operating Instructions

Instruction Manual For Auto Shift Hydraulic Lift Table

Installation, Operation and Maintenance Instructions

Fisher 657 Diaphragm Actuator Sizes and 87

11.Preparation for Overhaul

Baumann Sanitary Diaphragm Angle and Inline Control Valve

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

High Vacuum Diaphragm-Type Dry Vacuum Pump

Declaration of Conformity as per Directive 97/23/EC

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

GT-200 GATE VALVES PN16, Screwed end

METERING VALVE 2" STEM GUIDED

These installation and maintenance instructions must be read in full and completely understood before the installation!

Transcription:

Serial No. H-V031-E-8 Diaphragm Valves Type 15 User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation, unpacking and storage 3 (4) Name of parts 4 (5) Working pressure vs. temperature 6 (6) Specification of limit switch 7 (7) Installation procedure 7 (8) Connection of limit switch procedure 8 (9) Operating procedure 9 (10) Adjustment procedure for stopper 10 (11) Diaphragm replacement procedure 11 (12) Inspection items 12 (13) Troubleshooting 12 (14) Handling of residual and waste materials 12 Diaphragm Valves Type 15

This user s guide contains information important to the proper installation, maintenance and safe use of an ASAHI AV Product. Please store this manual in an easily accessible location. <Warning & Signs> Warning This symbol reminds the user to take caution due to the potential for serious injury or death. <Prohibited & Mandatory Action Signs> This symbol reminds the user to take caution due to the potential for damage to the valve if used in such a manner. Prohibited: When operating the valve, this symbol indicates an action that should not be taken. Mandatory action: When operating the valve, this symbol indicates mandatory actions that must be adhered to. (1) Be sure to read the following warranty clauses of our product - Always observe the specifications of and the precautions and instructions on using our product. - We always strive to improve product quality and reliability, but cannot guarantee perfection. Therefore, should you intend to use this product with any equipment or machinery that may pose the risk of serious or even fatal injury, or property damage, ensure an appropriate safety design or take other measures with sufficient consideration given to possible problems. We shall assume no responsibility for any inconvenience stemming from any action on your part without our written consent in the form of specifications or other documented approval. - The related technical documents, operation manuals, and other documentation prescribe precautions on selecting, constructing, installing, operating, maintaining, and servicing our products. For details, consult with our nearest distributor or agent. - Our product warranty extends for one and a half years after the product is shipped from our factory or one year after the product is installed, whichever comes first. Any product abnormality that occurs during the warranty period or which is reported to us will be investigated immediately to identify its cause. Should our product be deemed defective, we shall assume the responsibility to repair or replace it free of charge. - Any repair or replacement needed after the warranty period ends shall be charged to the customer. - The warranty does not cover the following cases: (1) Using our product under any condition not covered by our defined scope of warranty. (2) Failure to observe our defined precautions or instructions regarding the construction, installation, handling, maintenance, or servicing of our product. (3) Any inconvenience caused by any product other than ours. (4) Remodeling or otherwise modifying our product by anyone other than us. (5) Using any part of our product for anything other than the intended use of the product. (6) Any abnormality that occurs due to a natural disaster, accident, or other incident not stemming from something inside our product. Diaphragm Valves Type 15 1

(2) General operating instructions Warning - Using a positive-pressure gas with our plastic piping may pose a dangerous condition due to the repellent force particular to compressible fluids even when the gas is under similar pressures used for liquids. Therefore, be sure to take the necessary safety precautions such as covering the piping with protective material. For inquiries, please contact us. For conducting a leak test on newly installed piping, be sure to check for leaks under water pressure. If absolutely necessary to use a gas in testing, please consult your nearest service station beforehand. - Do not step on or apply excessive weight on valve. (It can be damaged.) - Do not use the valve in conditions where the fluid may have crystallized. (The valve will not operate properly.) - Keep the valve away from excessive heat or fire. (It can be damaged, or destroyed.) - Always operate the valve within the pressure vs. temperature range. (The valve can be damaged or deformed by operating beyond the allowable range.) - Allow sufficient space for maintenance and inspection. - Select a valve material that is compatible with the media. For chemical resistance information, refer to CHEMICAL RESISTANCE ON ASAHI AV VALVE. (Some chemicals may damage incompatible valve materials.) - Keep the valve out of direct sunlight, water and dust. Use cover to shield the valve. (The valve will not operate properly.) - Perform periodic maintenance. (Leakage may develop due to temperature changes or periods of prolonged storage, rest, or operation.) - The travel stop may have to be adjusted if media leakage is detected between the upstream & downstream sides of the valve. - Bonnet bolt torque should be checked before installation, as they may become loose after long-term storage. A periodic check of the valve condition as well as bonnet & flange bolt torque should be made part of preventative maintenance program properly re-tightening the bolts as necessary. It is especially important to re-tighten all bolts during the first shutdown. Nom. Size mm (inch) 125 (5) Bonnet tightening torque value N m {kgf cm} [lb inch] Rubber PTEF 45.0 {459} [400] 45.0 {459} [400] 150 (6) 45.0 {459} [400] 45.0 {459} [400] Diaphragm Valves Type 15 2

(3) General instructions for transportation, unpacking and storage Installation, Operation and Maintenance Manual Warning - When suspending and supporting a valve, take care and do not stand under a suspended valve. - This valve is not designed to handle impacts of any kind. Avoid throwing or dropping the valve. - Avoid scratching the valve with any sharp object. - Do not over-stack cardboard shipping boxes. Excessively stacked packages may collapse. - Avoid contact with any coal tar creosote, insecticides, vermicides or paint. (These chemicals may cause damage to the valve.) - When transporting a valve, do not carry it by the handle. - Store products in their corrugated cardboard boxes. Avoid exposing products to direct sunlight, and store them indoors (at room temperature). Also avoid storing products in areas with excessive temperatures. (Corrugated cardboard packages become weaker as they become wet with water or other liquid. Take care in storage and handling.) - After unpacking the products, check that they are defect-free and meet the specifications. Diaphragm Valves Type 15 3

(4) Name of parts Nominal Size: 125, 150mm (5, 6 ) No. DESCRIPTION No. DESCRIPTION No. DESCRIPTION [1] Body [9] Sleeve(A) [20] Nut [1a] Inserted Nut [10] Thrust bearing(a) [21] Gauge cover [2] Bonnet [11] O-ring (A) [22] Bonnet liner [3] Diaphragm [12] Grease Nipple [23] Stud bolt nut [3a] Inserted metal of DIA [13] Hand wheel [24] Bolt Nut [4] Cushion [14] Name Plate [26] Body liner [4a] Cushion cover [15] Cap [27] Rib liner [5] Compressor [17] Sheet ring [28] U-bolt nut [7] Compressor Pin [18] Stopper [29] Conical spring washer [8] Stem [19] Spring washer [22], [26], [27], [28], [29] are used with special specification. Diaphragm Valves Type 15 4

Nominal Size: 125, 150mm (5, 6 ) with Limit Switch (Option) No. DESCRIPTION No. DESCRIPTION [36] Limit Switch [38] Nut (A) [37] Bracket (A) [40] Limit Switch Rod Diaphragm Valves Type 15 5

(5) Working pressure vs. temperature Diaphragm Valves Type 15 6

(6) Specification of limit switch (option) Nominal Size Type Code Protection Grade 125, 150mm (5, 6 ) 1LS1-J IP67 Limit Switch Rating Rate Voltage (V) Resistive Load (A) Inductive Load (A) AC125 10 6 AC250 10 6 DC115 0.8 0.2 DC230 0.4 0.1 Connection Diagram (7) Installation procedure - When suspending and supporting a valve, take care and do not stand under a suspended valve. Warning - Be sure to conduct a safety check on all hand and power tools to be used before beginning work. - Wear protective gloves and safety goggles as fluid remain in the valve even if the pipeline is empty. (You may be injured.) - When installing a pipe support by means of a U-band or something similar, take care not to over-tighten. (Excessive force may damage the pipe.) - When installing pipes and valves, ensure that they are not subjected to tension, compression, bending, impact, or other excessive stress. - When installing, disassembling, or reassembling the piping, fix the End Connector. - When connecting an ASAHI AV Valve to metal piping, take care not to let the pipe stress on the ASAHI AV Valve. - Be sure to use sealing gaskets (AV Gasket), bolts, nuts, and washers and tighten them to specified torques. (When a non-av gasket is used, a different tightening torque specification should be followed.) Necessary items Torque wrench Spanner wrench Bolt, Nut, Washer (For many flanges specification) AV gasket Procedure 1) Set the AV gasket between the flanges. 2) Insert washers and bolts from the pipe side, insert washers and nuts from the valve side, then temporarily tighten them by hand. Diaphragm Valves Type 15 7

- The parallelism and axial misalignment of the flange surface should be under the values in the shown following table to prevent damage the valve. (A failure to observe them can cause destruction due to stress application to the pipe) (Axial misalignment) (Parallelism) Nom. Size 125,150mm (5, 6 ) Axial Misalignment Unit : mm (inch) Parallelism (a-b) 1.0 (0.04) 1.0 (0.04) 3) Using a torque wrench, tighten the bolts and nuts gradually to the specified torque in a diagonal manner (Refer to fig.1.) Specified torque value Unit : N m{kgf cm}[lb inch] Nom. Size 125mm (5 ) 150mm (6 ) Torque value 40.0{408} [355] 40.0{408} [355] - Tighten the bolts and nuts gradually with a torque wrench to the specified torque level in a diagonal manner. (8) Connection of limit switch procedure (option) Warning - Shut down the power on the equipment before connecting wires. There are risks of electrical shock depending on the level of operating voltage. - Be sure that the terminal cover and body cover are put on during the operation. - If you use the limit switch at 1mA-100mA or 5-30V, consult near Asahi dealer. Necessary items Screw driver (+) Connector (G1/2) Crimp-style terminal Wire stripper Terminal crimping tool Diaphragm Valves Type 15 8

Procedure Installation, Operation and Maintenance Manual 1) Loosen the three screws used to attach the limit switch cover with a screwdriver (+) and remove the cover from the limit switch. *These screws are captive. 2) Pull and remove the protective cap, made of resin, from the cover. 3) Draw the cable through the connector. 4) Strip the cable with a wire stripper. 5) Install a crimp-style terminal on the lead wire with a terminal crimping tool. 6) Connect the terminal screw with a screwdriver (+) according to the internal circuit diagram show in page 7. * Tighten the screws. (If not, electric leaks or shocks may occur.) 7) Tighten the above three screws with a screw driver (+) to install the cover on the limit switch. 8) Tighten the cable by connector. (9) Operating procedure - Do not exert excessive force in closing the valve. - Do not use the valve to fluid containing slurry. (The valve will not operate properly.) - The installed valve must never be opened or closed when foreign matter such as sand is present in the pipeline. - When operating the handle, be sure to do so with your hand. (Using a tool may damage the handle.) - If a stopper is loose, adjust it. (To learn how to adjust it, see the operation manual.) Open and close the valve by rotating hand wheel. The top of the travel stop will be flush with the top of the hand wheel when the valve is fully closed. Full shut Half open Full open Diaphragm Valves Type 15 9

(10) Adjustment procedure for stopper - If a stopper is loose, adjust it. (To learn how to adjust it, see the operation manual.) - Tighten the stoppers securely. (Too weak a torque on a stopper may cause it to loosen.) Necessary items Spanner wrench Allen wrench Driver(-) Protective Gloves Goggles Travel stop adjustment 1) Loosen the gauge cover [21] with hand. 2) Loosen the nut [18] from the stopper [20] with spanner wrench. 3) Loosen the stopper [20]. 4) Operate the hand wheel to tighten gradually until the leakage of fluid stops. 5) Tighten the stopper [20] until it stop, and then turn it back (counter-clockwise) 180. 6) Tighten the nut [18] to the stopper [20] with spanner wrench. 7) Tighten the gauge cover [21]. Tightening torque of the screw Unit : N m {kgf cm} [lb inch] Nom. Size 125mm (5 ), 150mm(6 ) Torque valve 10.0 {102} [89] Diaphragm Valves Type 15 10

(11) Diaphragm replacement procedure - If you do work with the piping installed, drain the piping of all its fluid. Some fluid will remain in the valve. Therefore wear protective goggles and protective gloves. (You may otherwise get injured.) Necessary items Torque wrench Protective gloves Spanner wrench Safety goggles 1) Drain fluid completely from the pipeline. 2) Remove valve bonnet from the body. 3) Turn handle of valve clockwise until it stops. (Do not force it). The compressor should be fully extended out of the bonnet. 4) Turn the diaphragm clockwise to remove the diaphragm and mount the new diaphragm by reversing step. 5) Mount the bonnet to the valve by reversing step 2. Tighten bonnet bolts by hand only. 6) Rotate the handle 360 counter-clockwise. 7) Using a torque wrench, tighten the bonnet bolts in a diagonal, cross-cross pattern. Bonnet torque value Unit : N m {kgf cm} [lb inch] Nom. Size Diaphragm 125mm (5 ),150mm (6 ) Rubber 45 {459} [400] PTFE 45 {459} [400] 8) Re-adjust the stopper if necessary. Diaphragm Valves Type 15 11

(12) Inspection items - Perform periodic maintenance. (Leakage may develop due to temperature changes or over periods of prolonged storage, rest or operation.) Inspect the following items. (1) Check for any flaw, crack, or deformation on the outside. (2) Check whether fluid leaks to the outside. (3) Check the tightness of coupled bolt nut between the body and the bonnet and that of the gauge cover (loose or not). (4) Check whether the operation of the handle is smooth. (13) Troubleshooting and action Problem Cause Treatment Fluid is leaking past the fully closed position. Valve can not be fully open. The handle spins freely. Valve leaks between body and bonnet. The travel stop is not set correctly. Solid particles have lodged in the valve. Media has worn diaphragm and / or weir. The diaphragm has pulled off the stem. The metal joint failed. The stem is broken. The metal joint failed. Bonnet bolts have loosened. Media has crystallized on the diaphragm. The diaphragm has failed due to fatigue. Adjust the travel stop. Clear the solid particles from the valve. Replace. Replace diaphragm. If the valve is in vacuum service, special vacuum valves may be required. Consult factory. Remove diaphragm & compressor and replace joint. Disassemble bonnet and replace the stem. Remove diaphragm & compressor and replace joint. Re-tighten. Disassemble and clean on a regular basis. Replace failed diaphragm, if necessary. Replace. Valve leaks from stem. The diaphragm has failed. Replace. (14) Handling of residual and waste materials Warning - Make sure to consult a waste treatment dealer for recommendations on the proper disposal of plastic valves. (Poisonous gas is generated when the valve is burned improperly.) Diaphragm Valves Type 15 12

Installation,Operation and Maintenance Manual Diaphragm Valve Type 15 Distributor http://asahi-yukizai.co.jp./en/ Information in this manual is subject to change without notice. 2016.4 Diaphragm Valves Type 15