Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Similar documents
Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Operating and Installation Instructions Diaphragm Gas Sampling Pumps

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Swing Piston Compressors and Vacuum Pumps

Diaphragm-Gas Sampling Pumps

Diaphragm Vacuum Pump

DIAPHRAGM VACUUM PUMP

Diaphragm Gas Sampling Pumps

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Mini Diaphragm Vacuum Pumps

Micro Diaphragm Gas Sampling Pumps

Micro Diaphragm Gas Sampling Pumps

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pump and Compressor

Diaphragm Vacuum Pumps and Compressors

DIAPHRAGM LIQUID PUMP NF 1.25

Analytical Diaphragm Pump Series MP MP06, MP12

DIAPHRAGM LIQUID PUMP NF 1.30

DIAPHRAGM LIQUID PUMP NF 2.35

Micro diaphragm liquid pump NF 1.5 NFB 5

DIAPHRAGM LIQUID PUMP NF 30, NFB 30

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

DIAPHRAGM VACUUM PUMP

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

High Vacuum Diaphragm-Type Dry Vacuum Pump

DIAPHRAGM LIQUID PUMP NF 100, NF 1.100, NFB 100

DIAPHRAGM LIQUID PUMP NF 10, NF 11, NF 1.11

Micro diaphragm liquid pump NF 25 NFB 25

Diaphragm-Gas Sampling Pumps N 0150 ANE N 0150 ATE N 0150 STE N ANE N ATE N STE

Diaphragm Pumps for Air, Gases and Vapours LABOPORT Mini Diaphragm Vacuum Pumps and Compressors

DIAPHRAGM METERING PUMP FEM 1.02, FEM 1.09

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS TO ATEX

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

Angle seat valve with piston actuator VZXA-...-K

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

VEM motors Thurm GmbH

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Diaphragm Vacuum Pump

MICRO DIAPHRAGM GAS PUMPS NMP 830, NMP 850 and NMP

Installation and Operation Manual

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN

Diaphragm Pumps N 1200 A_E N 1200 S_E N A_E N S_E N A_E N S_E N A_E N S_E

Betriebsanleitung Operating Instructions. Oil Mist Filter

NAF-Torex butterfly valves Maintenance and installation instructions List of spare parts

Pneumatic Axial Fan Type Tech. Doc. No. 802

ELECTRIC LIFTING HOIST

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner

BR 31a Rack-and-pinion Actuator,

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Type 6213 EV, 6281 EV

Operating Instructions

Operating Instruction for Liquid-Ring Vacuum Pumps

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Installation, Operating, Maintenance and Safety Instructions JABSCO & Series 1 40 SIZE UTILITY Pump

BOLT TENSIONERS. carefully before use and retain it for reference.

JABSCO & Series 1½ 80 SIZE UTILITY Pump

SB-E-2-CBA1 ISS.13. Operation Manual Cobra 1 Automatic Spray Gun

6066 OILLESS VACUUM PUMPS AND COMPRESSORS OPERATION & MAINTENANCE TECHNICAL MANUAL

PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions

Pressure relief valve

MINI DIAPHRAGM VACUUM PUMPS

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm²

Instruction Manual. EBV Gas Ballast Valves. EBV20 Gas Ballast Valve, 110 V, 50/60 Hz. EBV100S Gas Ballast Valve, 240 V, 50/60 Hz

Angle seat valve with diaphragm actuator VZXA-...-M

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

These installation and maintenance instructions must be read in full and completely understood before the installation!

Installation and Operating Instructions Electric Vibrators HV/VFL Series

Operation Manual Cobra 1 Automatic Spray Gun

Features. Marathon SL TECHNICAL CHARACTERISTICS. Sliding bushes: made of friction free and wear free material.

Differential Pressure Switch QBM81-

SB ISS.04. Operation Manual AGMDPRO Automatic Spray Gun

Zone 1 Linear Range - Installation Guide

PNEUMATIC PUMP Series

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

Operating Instructions for Roll-Up Door Operators / MDF

A Issue F. Instruction Manual. Outlet Mist Filters and Catchpots. MF300AE outlet mist filter

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

D58 Series Brake Instructions

Operating manual Separator

Operating Instructions

Operation & Maintenance Manual

POSITIVE DISPLACEMENT FLOWMETERS

Installation and Operating Instructions

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

Operating and Installation Instructions Pulsation Damper P Series for Pumps of the BIOCOR Series

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

PRECISION UK Ltd DUPLEX AGSS PLANT

LEAD ACID BATTERY CHARGER

Transcription:

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected a high-quality KNF product; the following tips will help you operate it safely and reliably over a long period of time. Carefully study the Operating and Installation Instructions before using the pumps and observe at all times the relevant instructions to avoid dangerous situations. The manual was produced for the serial pumps stated above. With customer-specified projects (pump types starting with PU or MPU ) there could be differences in detail. For customer-specified projects please therefore take into account any agreed technical specifications, as well as these instructions. KNF Neuberger, Inc 2 Black Forest Rd Trenton, NJ 08691-1810 Phone: 609-890-8600 Fax: 609-890-8323 www.knf.com/usa.htm Ident#121240-211582 Revision (06/12) List of Contents Page 1. Description, Operating Conditions... 2 2. Safety... 4 3. Installation... 4 4. Operation... 6 5. Servicing... 8 6. Cleaning... 11 7. Trouble Shooting... 12 8. Spare parts and accessories... 14 9. Tables... 15 10. Product Return... 16

Description, Operating Conditions Diaphragm Vacuum Pump UN813_I 1. Description, Operating Conditions KNF pumps in the UN813.3AN, UN813.4AN, and UN813.5ANE range transfer and evacuate 100% oil-free. 1.1. Electrical Equipment See the motor-plate for full electrical data. Protection class of standard version is: UN813.3ANI: IP 44 UN813.3ANDCB: IP 20 UN813.4ANI: IP 54 UN813.4ANDCB: IP 20 UN813.5ANI IP 54 The ac motors used are fitted as standard with a thermal switch to protect against overloading. The pumps with brushless DC motor are protected against overheating by a temperature sensor on the motor board and equipped with overcurrent protection. 1.2. Operating Conditions Handling air, gases, and vapours at temperatures between + 5 C + 40 C. For maximum permissible operating pressure, ultimate vacuum, and flow capacity see section 9. The pumps are not suitable for aggressive media. For aggressive media there are other pumps in the KNF product programme please ask us for detail. The pumps must not be used in areas where there is a danger of explosion. Before pumping a medium, the compatibility of materials of pump head, diaphragm and valves with the medium must be checked (for pump materials: see section 9). KNF pumps in the UN813.3AN, UN813.4AN, and UN813.5ANE range must not be used for liquids. You will find suitable liquid pumps in our Product Program. If your potential application lies outside the above limits discuss it with our technical adviser (see last page for contact telephone number). 1.3. Ambient Conditions When the pump is operating the following ambient conditions must be maintained: Ambient temperature during operation: between + 5 C + 40 C. 2

Diaphragm Vacuum Pump UN813_I Description, Operating Conditions During operation an adequate supply of air for cooling must be provided. The pumps must not be used in areas where there is a danger of explosion. 1.4. Pump materials See section 9. 3

Safety Diaphragm Vacuum Pump UN813_I 2. Safety Note that the pumps may only be used for their intended purpose (see section 9). The pumps must not be used in areas where there is a danger of explosion. The pumps are not suitable for aggressive media. For aggressive media there are other pumps in the KNF product program please ask us for detail. For vacuum pumps: The discharge of gas on the pressure side of the pump must be safely disposed. Components connected to the pump must be designed to withstand the pneumatic performance of the pump. Take care that safety regulations are observed when connecting the pump to the electricity supply. For pumps with a thermal switch: When the operation of the pump is interrupted by the thermal switch, the pump will re-start automatically after cooling down. Take all care necessary to prevent this leading to a dangerous situation. Specific safety instructions for the media being handled must be observed. Use only original KNF spare parts. EC Directives / Standards For the purposes of the Machinery Directive 2006/42/EC, pumps are partly completed machinery, and are therefore to be regarded as not ready for use. Partly completed machinery may not be commissioned until such time as it has been determined that the machine in which the partly completed machinery is to be assembled is in conformity with the provisions of the Machinery Directive 2006/42/EC. The essential requirements of Annex I of Directive 2006/42/EC (general principles) are applied and observed. The pumps conform to the EC Directive 2004/108/EC concerning Electromagnetic Compatibility. The following harmonized standards have been used: UN813.3ANI UN813.4ANI UN813.5ANI UN813ANDCB UN813ANDCB DIN EN 55014-1/2 DIN EN 55014-1/2 DIN EN 61000-3-2/3 DIN EN 60204-1 Tab. 1 4

Diaphragm Vacuum Pumps N 813 Installation Mechanical Electrical Pneumatic 3. Installation The pumps are OEM models intended for installation in equipment. When installing them make certain that accident prevention regulations, and safety instructions, including those for subsequent operation are observed. The safety instructions in section 2 must be observed. The dimensions of the mountings are given in Data Sheet. Install the pump so that the fan can draw in sufficient cooling air. Fit the pump at the highest point in the system, so that condensate cannot collect in the head of the pump - that prolongs working life. When making the electrical installation the safety regulations must be observed. In particular make sure that the electricity supply is isolated before trying to connect the pump. Compare the supply data with the data on the motor-plate. The voltage must not vary by more than +10% and -10% from that shown on the type-plate. The motor must be connected to earth (ground) wire (not necessary on dc motors up to 24 V). With dc motors the wires must be connected to the correct polarity. In the electrical installation, arrangements (complying with EN 60335-1) must be made for disconnecting the pump motor from the electrical supply. The pump must be installed so that contact with live parts is impossible. For pumps with ac motor: We recommend that a fuse is installed in the supply circuit; the operating current is given in Data Sheet. Remove the protection plugs from the port threads. The accessories, silencer, and hose connectors (where applicable) are screwed into the port threads. Connect the suction and pressure lines. For flow direction, see marking on the pump head or data sheet. Arrange the suction and pressure lines so that condensate cannot run into the pump (sloping lines). For vacuum pumps: The discharge of gas on the pressure side of the pump must be safely disposed. 5

Operation Diaphragm Vacuum Pumps N 813 4. Operation The pumps may not be used in areas where there is a danger of explosion. Specific safety instructions for the media being handled must be observed. If combustible media are used: Hazard of fires and explosions due to excessively high media temperature. Be aware that the pumps are not designed to be explosion-proof. Make sure the temperature of the medium is always sufficiently below the ignition temperature of the medium, to avoid ignition or explosion. This also applies for unusual operational situations. Note that the temperature of the medium increases when the pump compresses the medium. Hence, make sure the temperature of the medium is sufficiently below the ignition temperature of the medium, even when it is compressed to the maximum permissible operating pressure of the pump. The maximum permissible operating pressure of the pump is stated in the technical specifications (table 1). If necessary, consider any external sources of energy, such as radiation, that may add heat to the medium. In case of doubt, consult the KNF customer service. Before pumping a medium, the compatibility of materials of pump head, diaphragm and valves with the medium must be checked (for pump materials: see section 9). The pump must not start against pressure. This must be so even when the pump restarts after the power has been cut off for a short period. The maximum permissible operating pressure (see section 9) must not be exceeded. To prevent the maximum permissible operating pressure being exceeded, restriction or control of the air or gas flow should only be carried out in the suction line. If restriction or control of the air or gas flow is made on the pressure side ensure that the maximum permissible operating pressure is not exceeded. For vacuum pumps, the exhaust gases must be safely disposed. When the pump has been at a standstill the inlet and exhaust must be at normal atmospheric pressure. Diaphragm and valve plates are the only parts subject to wear. Wear is usually indicated by a drastic reduction in the pneumatic 6

Diaphragm Vacuum Pumps N 813 Operation performance. When replacing parts proceed as described in section 5. Ambient conditions: see section 1.3. 7

Servicing Diaphragm Vacuum Pumps N 813 Fig. 3: Pump elements (for all pump types) 5. Servicing Before working on the pump, isolate the power supply securely, then check that the lines are not live. Diaphragm and valve plates are the only parts of the pump subject to wear. They are simple to change. Always change diaphragm, valve plates and sealing rings at the same time. In the case of models with two or four heads service all heads. If a pump has been used for toxic substances or other types of substances which are hazardous, hazardous to health, or injurious, the following points must be observed: 1. Clean the pump and its components before servicing. 2. Ensure that the safety personnel is not subject to health hazard. Apply the safety and protection measures that are necessary for the medium that has been handled by the pump (example: the use of protective gloves). 3. Ensure that discarded parts and materials are safely and correctly disposed of. Use only original KNF replacement parts. Fig. 4: Two-headed types Fig. 5: Four-headed types Fig. 6: Pneumatic Connection (principle sketch) Specification Pos. Description 1 Housing 2 Intermediate plate 3 Ribbed plate 4 Hexagon socket head cap screw 5 Cover plate 6 Valve plate 7 Sealing ring 8 Structured diaphragm 9 Diaphragm Spacer(s) 10 Connecting rod 11 Counter weight 12 Pneumatic connection.3 13 Union 14 Pneumatic connection.4* 15 Pneumatic connection.5** *: UN813.4AN_: 2 pieces UN813.5ANI: 1 piece **: UN813.5ANI: 2 pieces 8

Diaphragm Vacuum Pumps N 813 Servicing Spare part Spare part* Valve plates Structured diaphragm Sealing rings Quantity 2 (per pump head) 1 (per pump head) 2 (per pump head) Tab. 2: Spare parts * According to Spare parts list, section 8 Tools Type range UN813.4 AN_ and UN813.5 ANI Tab. 3: Tools and material Tools/Material Ring spanner 14 mm (alternative: open-ended spanner 14 mm) Open-ended spanner 17 mm Phillips screwdriver No. 1 Felt-tip pen Change the diaphragms, valve plates and sealing rings in the following sequence: a) Removing head connection(s) b) Removing cover plate from housing c) Removing pump head d) Changing diaphragm e) Changing valve plates and sealing rings f) Refitting pump head g) Refitting the cover plate h) Refitting the head connection(s) With the exception of removal and refitting of the cover plate (or cover plates), and the head connections, all operations are to be carried out separately for each head. This prevents the parts getting mixed up (the ribbed plates are not identical). The position numbers in the following text refer to figs. 3 to 6. Proceed as follows: a) Removing pneumatic head connections (once for all pump heads) UN813.3AN : 1. Remove pneumatic connection (12): Use a 14 mm spanner to release the unions (13) on each head, and remove the pneumatic connection upwards. UN813.4AN : 1. Remove pneumatic connection (12): Use a 14 mm spanner to release the unions (13) on each head, and remove the pneumatic connection upwards. 2. Release both pneumatic connections (14) with a 17 mm open-ended spanner, and remove them. 9

Servicing Diaphragm Vacuum Pumps N 813 UN813.5ANI: 1. Remove pneumatic connection (12): Use a 14 mm spanner to release the unions (13) on each head, and remove the pneumatic connection upwards. 2. Release both pneumatic connections (14) with a 17 mm open-ended spanner, and remove them. 3. Open both pneumatic connections (15) with a 17 mm open-ended spanner, and remove them. b) Removing cover plate 1. Undo the 4 screws and remove the cover plate (5) from housing (1) (UN813.3AN : 1 cover plate; UN813.4AN, and UN813.5ANI: each two cover plates). c) Removing the pump head (for each head separately) 1. Make a mark (M) on the ribbed plate (3), intermediate plate (2), and housing (1) with a felt-tip pen. This helps avoid incorrect assembly later. 2. Undo the 4 screws (4) in the ribbed plate and lift the ribbed plate with the intermediate plate off the pump housing. d) Changing diaphragms 1. Turn the counter weight (11) to bring the structured diaphragm (8) to top dead centre. 2. Lift the edge of the diaphragm and, gripping it on opposite sides, unscrew it by turning anti-clock-wise. 3. Take the diaphragm spacer(s) (9) off the threaded portion of the structured diaphragm and put them on the thread of the new structured diaphragm (8). 4. Check that all parts are free from dirt and clean them if necessary (see section 6. Cleaning). 5. Turn the counter weight (11) until the connecting rod (10) is at the top dead centre. 6. Screw the structured diaphragm, complete with diaphragm spacer(s), into the connecting rod (clockwise) and tighten it by hand. e) Changing valve plates and sealing rings 1. Separate the ribbed plate (3) from intermediate plate (2). 2. Remove the valve plates (6) and sealing rings (7) from the intermediate plate. 3. Check that the valve seats, the ribbed plate and intermediate plate are clean. If scratches, distortion, or corrosion are evident on these parts they should be replaced. 4. Lay the new valve plates in the recesses in the intermediate plate. The valve plates for suction and pressure sides are identical, as are upper and lower sides of the plates. 5. Check that the valve plates are not deformed by moving them gently sideways in their recesses. 10

Diaphragm Vacuum Pumps N 813 Cleaning 6. Lay the sealing rings on the intermediate plate. f) Refitting the pump heads 1. Turn the counter weight (11) to bring the structured diaphragm (8) to top dead centre. 2. Place the intermediate plate (2), with valve plates (6) and sealing rings (7), and ribbed plate (3) on the housing, in the position indicated by the markings (M). 3. Gently tighten the screws (4), evenly and diagonally. 4. Turn the counter weight to check that the pump rotates freely. 5. Now tighten screws (4) firmly. Repeat operations c), d), e), and f) for the remaining pump head (or heads). g) Refitting the cover plate 1. Refit the cover plate (5) to housing (1). h) Refitting the pneumatic head connection(s) 1. Refit the pneumatic head connection(s). If you have any questions about servicing call our technical adviser (see last page for contact telephone number). 6. Cleaning When changing valve plates and wave diaphragm, inspect all parts for dirt before assembling the pump head, and clean them if necessary. If a compressed air line is available, blow the parts out with it. 11

Trouble Shooting Diaphragm Vacuum Pumps N 813 7. Trouble Shooting Before working on the pump isolate the power supply securely, then check that the lines are not live. The following tips for fault-finding are best employed in the sequence shown. Pump produces no flow Overload protection has actuated. Disconnect pump from mains. Trace cause of overload and eliminate it. Connections or lines are blocked An external valve is closed, or a filter blocked. Liquid (condensate) has collected in the pump head. Let the pump run for a few minutes pumping air (if necessary for safety reasons: pumping an inert gas.) Install the pump at the highest point in the system. Diaphragms or valve plates are worn: Section 5 Servicing. Flow, pressure, or vacuum too low Compare the actual performance with the figures in section 9 or the data sheet. Liquid (condensate) has collected in the pump head. Let the pump run for a few minutes pumping air (if necessary for safety reasons: pumping an inert gas.) Install the pump at the highest point in the system. There is pressure on the pressure side, and at the same time vacuum, or a pressure above atmospheric, on the suction side. The pump is not designed for this condition. Please call our technical advisor (see last page for contact telephone number). The cross-section of pneumatic lines, or connected components is too small, or they are restricted. To measure the performance, disconnect the pump from the system (small diameter tubing or a valve can significantly affect performance). There is a leak at a connector, in a line, or in the pump head. Diaphragm or valve plates are worn, or dirt is in the head. Section 5 Servicing. 12

Diaphragm Vacuum Pumps N 813 Trouble Shooting After changing the diaphragms or valve plates, a head has been reassembled in the wrong position. If the pump does not operate properly and you cannot find any of the above faults, send it to the KNF Service Department. In order for KNF to repair the pump, the customer must provide a statement on the media which were pumped and on pump cleaning. Please fill out the corresponding KNF form, and submit it together with the pump. A sample statement for copying can be found in section 10 of these Operating and Installation Instructions. 13

Spare parts and accessories Diaphragm Vacuum Pumps N 813 8. Spare parts and accessories Spare parts Pos. No* Spare part Order No. (2) Intermediate plate 200221 (5) Cover plate 026311 (6) Valve plate 024597 (7) Sealing ring 024598 (8) Structured diaphragm 044402 (9) Shim Ring 209483 (12) Pneumatic connection.3 203455 (14) Pneumatic connection.4 206623 (15) Pneumatic connection.5 206625 Tab. 4 *according Fig. 3 to 6 Accessories Description Order No. Filter/ Silencer 072233 Hose Connector 1/8 MPTM, ¼ HID 072235 Tab. 5: Accessories 14

Diaphragm Vacuum Pumps N 813 Tables 9. Tables Pump type Max. permissible operating pressure (bar g) Ultimate vacuum (mbar abs.) UN813.3ANI 1 3 13 UN813.3ANDCB 1 3 13 UN813.4ANI 1 0.5 13 UN813.4ANDCB 1 0.5 13 UN813.5ANI 1 1 19 Delivery rate* (l/min) at atm. pressure Tab. 6: Pneumatic Data *Litre at STP (1013 mbar); Pump type UN813.3ANI UN813.3ANDCB UN813.4ANI UN813.4ANDCB UN813.5ANI Material* Pump head Wave diaphragm Valve Aluminium EPDM EPDM alloy Aluminium EPDM EPDM alloy Aluminium EPDM EPDM alloy Aluminium EPDM EPDM alloy Aluminium EPDM EPDM alloy Tab. 7: Pump Materials *Material abbreviations according DIN ISO 1629 15

Product Return Diaphragm Vacuum Pumps N 813 KNF Neuberger, Inc 2 Black Forest Rd Trenton, NJ 08691-1810 Phone 609-890-8600 Fax 609-890-8323 10. Product Return KNF provides warranty and non-warranty repair services for all products. A Return Material Authorization (RMA) number is required for all product returns. To receive an RMA number, submit a completed Decontamination Declaration form to rma@knf.com The Decontamination Declaration form can obtained from our website or by contacting KNF Technical Services. http://www.knf.com/pdfs/decontamdec.doc Phone: 609-890-8600 Product return instructions will be provided when the RMA is issued. www.knf.com/usa.htm 16