ESE Series Cast Iron Sewage Pumps

Similar documents
Owner s Manual Drill and Light Weight Portable Utility Pumps

Matala. VersiFlow Series. Instruction and Maintenance Manual

StormPro BA Series Sump Pump

GeyserMax-Flow Series

StormPro BCV400 Sewage Ejector Pump

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

SUBMERSIBLE SUMP PUMPS

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

SUBMERSIBLE SUMP PUMPS

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

PRE-PLUMBED SEWAGE SYSTEM

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

HALLMARK INDUSTRIES INC

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

Ion Technologies WC33 Submersible Sump Pump

SHEF30 Submersible Sump/ Effluent Pump

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

GARDEN HOSE UTILITY PUMP

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

EBARA Fluid Handling

SUNC3000 / Item #40885

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

SUBMERSIBLE SWIMMING POOL DRAINER

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

SUPER PUMP OUT SYSTEM

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

FP0S2300X FP0S3000X. Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien,

Submersible Sewage Ejector Pump

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Model E75STVT. Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien,

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

OWNER S MANUAL. INSTALLATION AND OPERATION INSTRUCTIONS FOR 12 VOLT BATTERY BACK-UP SYSTEM Models: 92900, 92910

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

SP40 Submersible Sewage Ejector Pump

Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

SPECIFICATIONS Power supply required...see Motor and Cord Specifications chart below Motor duty...intermittent Discharge Adapter...

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

ON-SITE WASTEWATER PRODUCTS

Installation Manual. Q Series Quadplex Grinder Systems. Contents

Self-Priming Centrifugal Pumps

Ion Technologies SEF100-SEF200 Heavy Duty Sewage Pumps

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B

Submersible Effluent Pump

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

SH30 High Head Effluent Pump

MH Series - Horizontal Multistage Pump OWNER'S MANUAL

TABLE OF CONTENTS. Pump Selection General Safety Electrical Installation Troubleshooting Repair Parts...

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

STOCK No. 53DH04 MODEL 6EC-CIA-SFS STOCK No. 53DH05 MODEL 6EC-CIM STOCK No. 53DH06 MODEL 10EC-CIA-SFS. Installation Guide

Pump Installation and Service Manual HRS Hydromatic Retractable System

2460 / 2472 / Series Simplex Grinder Systems

Please contact your supplier (supplying dealer or contractor) if service is necessary or if you have any questions or need further assistance.

Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

PUMP VAULT S.T.E.P. SYSTEM

Ion Technologies ES45 Effluent Pump

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

PUMP PRIMING INSTALLATION CHECK MOTOR ROTATION PUMP START-UP MOTOR REPLACEMENT DISASSEMBLY ELECTRICAL HOOKUP ASSEMBLY

Flotec Pumps FP Click here for Pricing/Ordering for Pumps and Parts MOD. FP5230. Installation/Fonctionnement/Pièces

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

IMPORTANT SAFETY INSTRUCTIONS

SHALLOW WELL JET PUMP

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

PENTEK XE-6. OWNER S MANUAL 6 Submersible Motors 293 WRIGHT STREET, DELAVAN, WI PH: PENTEK

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

INSTALLATION & OPERATION MANUAL

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Transcription:

Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting................... 6 Repair Parts...................... 7 Warranty........................ 8

STOP Before you start A sump pump is an electrical device designed to operate in inherently wet environments. ALWAYS USE EXTREME CAUTION when installing or maintaining this product! Need Help: Call 1-877-326-3561 for assistance; Do Not Return to Store GENERAL SAFETY Important Safety Instructions Carefully read and follow all safety instructions in this manual and on pump. SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation, operation, and maintenance of the product. Save this manual for future reference. Safety Labels This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury! Indicates a hazard which, if not avoided, will result in death or serious injury. Indicates a hazard which, if not avoided, could result in death or serious injury. General Safety Risk of burns. Do not touch an operating motor. Motors are designed to operate at high temperatures. To avoid burns when servicing pump, allow it to cool for 20 minutes after shut-down before handling. Do not allow pump or any system component to freeze. To do so will void warranty. Pump water only with this pump. Periodically inspect pump and system components. Wear safety glasses at all times when working on pumps. Risk of explosion. Pump body may explode if used as a booster pump. Indicates a hazard which, if not avoided, could result in minor or moderate injury. NOTICE indicates practices not related to personal injury. Keep safety labels in good condition. Replace missing or damaged safety labels. 2

APPLICATIONS Ideal for Below Grade Toilets, Laundry Facilities and for Use at Construction Sites. SPECIFICATIONS & PERFORMANCE Capacity Cord Solids Model HP Volt Ph Amps (GPH at 0 ) Max Head Construction Impeller Length Pumped ESE40M 4/10 115 1 11.0 6600 26 Cast Iron Thermoplastic 20 2 ESE40W 4/10 115 1 11.0 6600 26 Cast Iron Thermoplastic 20 2 ESE50M 1/2 115 1 12.0 7800 27 Cast Iron Thermoplastic 20 2 ESE50W 1/2 115 1 12.0 7800 27 Cast Iron Thermoplastic 20 2 ESE60M 6/10 115 1 12.0 9910 26 Cast Iron Thermoplastic 20 2 ESE60W 6/10 115 1 12.0 9910 26 Cast Iron Thermoplastic 20 2 281.8 [11.10] 380.4 [14.99] 137.4 [5.41] 2"NPT 212[8.35] 138.8 [5.47] 49.9 [1.97] 3

INSTALLATION Do not use an extension cord. Do not work on pump until power is unplugged. Do not cut off ground pin or use an adapter fitting. The pump power cord should be connected to a separately fused, grounded line with a minimum capacity of 15 amps. It can be connected to nonfuse breaker at the recommended amperes. 1. Before installing or servicing this pump, be certain pump s power source is disconnected. 2. Installation and electrical wiring must adhere to state and local codes and must be completed before priming pump. Check appropriate community agencies, or contact local electrical and pump professionals. 3. Call an electrician when in doubt. Pump should be connected to a separate 15 amp circuit breaker or 15 amp fuse block. Note that plugging into existing outlets may cause Entry pipe low voltage at motor. This could cause blown fuses, tripping of motor overload or burned out motor. 4. A permanent ground connection from pump to the grounding bar at the service panel is mandatory. These sump pumps come with a grounding conductor and a grounding-type attachment plug. Do not connect pump to a power supply until permanently grounded. For maximum safety, connect pump to a circuit equipped with a fault interrupter device when positioning the pump s grounding wire. 5. Voltage of power supply must match the voltage of the pump. 6. Before installing pump, clear sump basin of any water, debris or sediment. Sump basin must be vented in accordance with local plumbing codes. These Sump pumps are not designed for and CANNOT be installed in locations classified as hazardous. 7. The following may cause injury and/or severe damage to pump and will void the warranty. (a) Using an extension cord. (b) Cutting off the ground pin or using an adapter fitting. (c) Working on pump or switch while plugged in. (d) Removing motor housing, unscrewing impeller, or otherwise removing impeller seal. (e) Running the pump continuously. (f) Pumping chemicals or corrosive liquids. (g) Pumping gasoline or other flammable liquids 8. Plastic PVC pipe can be installed in the outlet piping. Drain hose, galvanized steel or copper pipe may be used if desired. All piping must be clean and free of all foreign matter to prevent clogging. 9. Pump will be inadequate if suspension liquids contain solid particles larger than 2. ELECTRICAL WIRE CONNECTION Verify that the voltage and frequency of the pump shown on the nameplate corresponds to those available on the mains. The installer must make sure that the electric system is grounded in accordance with code. For outdoor use it is necessary to use cable with a length of at least 8. The plug and connection should be protected from water splashes. Before using the pump, always inspect it visually (especially power cable and plug) Do not use pump if it is damaged If the pump is damaged, have it inspected by an authorized service center. Make sure that electric connections are protected from flooding. Protect the plug and the power cable from heat or sharp edges. The power cable must be replaced by qualified personnel only. Grounding: The plug of the power cable has a double grounding contact, so that grounding can be performed by simply inserting the plug. OVERLOAD PROTECTION This pump series has a built in thermal protection switch. The pump stops if an overload condition occurs. The motor restarts automatically after it has cooled down. If it doesn t start automatically, unplug the pump and plug it back in. 4

INSTALLATION Vent To control panel For automatic operation, pump must be plugged or wired into remote float switch or liquid level controller. Installation instructions included with switches and controllers should be referred to for installation. Pump will run continuously if plugged directly into an electrical outlet. Care should be taken to prevent pump running in a dry sump. Pump must be installed in a suitable gas tight basin which is at least 24 in diameter and 30 deep and vented in accordance with local plumbing codes. Pump must be placed on a hard level surface. Never place pump directly on clay, earth or gravel surfaces. Pump can be installed with ABS, PVC, polyethylene or galvanized steel pipe. Proper adapters are required to connect plastic pipe to pump.. Union Discharge pipe Gate valve Check valve Air bleed hole Always install a union in the discharge line, just above the sump pit to allow for easy removal of the pump for cleaning or repair. A check valve must be used in the discharge line to prevent back flow of liquid into the basin. The check valve should be a free flow valve that will easily pass solids. CAUTION: For best performance of check valves when handling solids install in a horizontal position or at an angle of not more then 45. Do not install check valve in a vertical position as solids may settle in valve and prevent opening start-up. When check valve is used, drill a relief hole 3/16 in diameter in the discharge pipe. This hole should be located below the floor line between the pump discharge and the check valve. Unless such a relief hole is provided, the pump could air-lock and will not pump water even though it will run. A gate valve should follow the check valve to allow periodic cleaning of the check valve or removal of the pump. The remainder of the discharge line should be as short as possible with a minimum of turns to minimize friction head loss. Do not restrict the discharge to sizes below 2. Sewage and effluent applications will require a separate sump vent. A connection is provided on top of the sump or cover which must be piped to the existing building vent or extended outside with its own standpipe. 5

TROUBLESHOOTING CHECKLIST (Caution: shut off power to pump) PROBLEMS PUMP DOES NOT RUN AND MAKES HUMMING SOUND PUMP RUNS BUT DOES NOT DELIVER WATER PUMP RUNS AND PUMPS OUT SUMP, BUT DOES NOT STOP PUMP RUNS BUT ONLY DELIVERS A SMALL AMOUNT OF WATER FUSE BLOWS OR CIRCUIT BREAKER TRIPS WHEN PUMP STARTS MOTOR RUNS FOR A SHORT TIME, THEN STOPS POSSIBLE CAUSES/SOLUTIONS Line circuit breaker is off, or fuse is blown or loose Water level in sump has not reached turn-on level as indicated in installation drawing. Pump cord is not making contact in receptacle. Float is stuck. It should operate freely in basin. If all of the above are OK, then the motor could be malfunctioning. Check if valve is installed backwards. Arrow on valve should point direction of flow Discharge shut-off valve (if used) may be closed. Impeller or volute openings are fully or partially clogged. Remove pump and clean. Pump is air-locked. Start and stop several times by plugging and unplugging cord. Check for clogged vent hole in pump case. Inlet holes in pump base are clogged. Remove pump and clean the openings. Vertical pumping distance is too high. Reduce distance or change the discharge fittings of the pump. Float is stuck in up position. Be sure float operates freely in basin. Defective float switch. Replace float switch. Pump is air-locked. Start and stop several times by plugging in and unplugging cord. Check for clogged vent hole in pump case. Vertical pumping distance is too high. Reduce distance or change the discharge fitting of the pump. Inlet holes in pump base are clogged. Remove pump and clean the strainer and openings. Impeller or volute openings are fully or partially clogged. Remove pump and clean. Pump impeller is partially clogged with tar or paint, causing motor to run slow and overload. Remove pump and clean. Pump impeller is partially clogged causing motor to run slow and overload. Remove pump and clean. Motor stator may be defective. Fuse size or circuit breaker may be too small. (must be 15 amps). Impeller or volute opening are fully or partially clogged. Remove pump and clean. Inlet holes in pump base are clogged. Remove pump and clean the openings. Pump impeller is partially clogged causing motor to run slow and overload. Remove pump and clean. Motor stator may be defective. Impeller or volute openings are fully or partially clogged. Remove pump and clean. Also clean the strainer if one is installed. ELECTRICAL PRECAUTIONS Before servicing a pump, always shut off the main power breaker and then unplug the pump. Make sure you are not standing in water and are wearing insulated protective sole shoes, under flooded conditions. Contact your local electric company or a qualified licensed electrician for disconnecting electrical service prior to pump removal 6

Retain Original Purchase Receipt for Warranty Eligibility WARRANTY Limited Warranty Manufacturer warrants to the original consumer purchaser ( Purchaser or You ) that its products are free from defects in material and workmanship for a period of twenty-four (24) months from the date of the original consumer purchase. If, within twenty-four (24) months from the original consumer purchase, any such product shall prove to be defective, it shall be repaired or replaced at manufacturer s option, subject to the terms and conditions set forth herein. Note that this limited warranty applies to manufacturing defects only and not to ordinary wear and tear. All mechanical devices need periodic parts and service to perform well. This limited warranty does not cover repair when normal use has exhausted the life of a part or the equipment. The original purchase receipt and product warranty information label are required to determine warranty eligibility. Eligibility is based on purchase date or original product not the date of replacement under warranty. The warranty is limited to repair or replacement of original purchased product only, not replacement product (i.e. one warranty replacement allowed per purchase). Purchaser pays all removal, installation, labor, shipping, and incidental charges. Claims made under this warranty shall be made by returning the product to the retail outlet where it was purchased or to the factory immediately after the discovery or any alleged defect. Manufacturer will subsequently take corrective action as promptly as reasonably possible. No requests for service will be accepted if received more than 30 days after the warranty expires. Warranty is not transferable and does not apply to products used in commercial/rental applications. General Terms and Conditions; Limitations of Remedies You must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty does not apply to the following: (1) acts of God; (2) products which, in manufacturer s sole judgment, have been subject to negligence, abuse, accident, misapplication, tampering, or alteration; (3) failures due to improper installation, operation, maintenance or storage; (4) atypical or unapproved application, use or service; (5) failures caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended maximums. This warranty sets forth manufacturer s sole obligation and purchaser s exclusive remedy for defective products. MANUFACTURER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state. 1899 Cottage Street, Ashland, Ohio 44805 Telephone: 1-877-326-3561 Fax: 1-877-326-1994 www.ecofloproducts.com 7