Owner s Manual Drill and Light Weight Portable Utility Pumps

Similar documents
ESE Series Cast Iron Sewage Pumps

Matala. VersiFlow Series. Instruction and Maintenance Manual

StormPro BA Series Sump Pump

GeyserMax-Flow Series

StormPro BCV400 Sewage Ejector Pump

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUPER PUMP OUT SYSTEM

Ion Technologies WC33 Submersible Sump Pump

AUTOMATIC SUBMERSIBLE UTILITY PUMP

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

Pump Installation and Service Manual HRS Hydromatic Retractable System

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

EBARA Fluid Handling

Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

SUNC3000 / Item #40885

GARDEN HOSE UTILITY PUMP

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

INSTALLATION & OPERATION MANUAL

1/2 HP SUMP PUMP OWNER'S MANUAL

SUBMERSIBLE POND PUMP

SUBMERSIBLE DIRTY WATER PUMP

ProFlo FatBoy

PRE-PLUMBED SEWAGE SYSTEM

MODEL P INSTALLATION INSTRUCTIONS

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

SPC-PANEL Simplex, Single Phase Pump Control Panel

HALLMARK INDUSTRIES INC

SHEF30 Submersible Sump/ Effluent Pump

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

ALITA LINEAR AIR COMPRESSORS INSTRUCTION MANUAL

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

ALITA INDUSTRIES, INC. Efficient and Reliable Air Moving Products ALITA LINEAR AIR COMPRESSORS OPERATION & MAINTENANCE MANUAL

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

Please contact your supplier (supplying dealer or contractor) if service is necessary or if you have any questions or need further assistance.

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

30ACi+, 30ACi Deluxe, 35ACi+ and 35ACi Deluxe Battery Backup System

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Air Curtain. Installation, Operating and Maintenance Instructions

Installation Operation Parts

user s manual Model number

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

36 VOLT AUTOMATIC BATTERY CHARGER PART NO

SUBMERSIBLE WATER PUMP

OPERATION & MAINTENANCE INSTRUCTIONS

Operating Manual Includes Pumps: PG-9000 Part #R809606

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

PUMP VAULT S.T.E.P. SYSTEM

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

IMPORTANT SAFETY INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

SUBMERSIBLE MINI-PUMP

STEP-BY-STEP INSTALLATION GUIDE

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

QPET, QPETXU Battery Chargers

TPAK Series COOLANT PUMP

TPHK Series Immersible Pump

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

SH30 High Head Effluent Pump

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

Transcription:

Owner s Manual Drill and Light Weight Portable Utility Pumps PUP61 Light Weight Utility Pump PUP62 Drill Pump with Kit PUP63 Drill Pump PUP61DC Light Weight Utility Pump LIMITED WARRANTY This pump is warranted to be free from defects in material and workmanship and to perform within applicable specifications for a period of one (1) year. Obligation under this warranty is limited to repairing or replacing any part thereof, which shall within two years be returned to us with transportation charges prepaid, and proved to be defective. The above limited warranty takes the place of all other warranties, express or implied and correction of such defects by replacement or repair shall constitute a fulfillment of all obligations under the terms of the warranty, which specifically EXCLUDES any incidental damages caused by or associated with this product or its use. The warranty does not cover any unit which has been damaged either in transit or by misuse, accident or negligence. No warranty or representative not contained herein shall be binding. MARKS AND MEANING: 1899 Cottage Street, Ashland, Ohio 44805 Teléfono: 1-877-326-3561 Fax: 1-877-326-1994 www.ecofloproducts.com 12 Copyright 2015, ECO-FLO PRODUCTS, INC. EF-DUOM-118 415 Keep pump equipment out of the reach of children! Failure to follow the directions given could cause serious risk to individuals or objects. This sign warns the operator that the failure to follow an instruction may damage the pump and/or the system. LIMITATIONS This pump is suitable to pump water and also can be used both for permanent and temporary installation. The pump can be placed in a sump pit to pump rain water containing suspended solid particles 1/4 or less in diameter.

INSTALLATION Do not work on pump until power is unplugged. Do not cut off ground pin or use an adapter fitting. Do not use an extension cord. The pump power cord should be connected to a grounded line with a minimum capacity of 15 amps. 1. Before installing or servicing this pump, be certain pump source is disconnected. 2. Installation and electrical wiring must adhere to state and local codes and must be completed before priming pump. Check appropriate community agencies, or contact local electrical and pump professionals. 3. Call an electrician when in doubt. Note that plugging into existing outlets may cause low voltage at motor. This could cause blown fuses, tripping of motor overload or burned out motor. 4. For maximum safety, connect pump to a circuit equipped with a fault interrupter device when positioning the pump s grounding wire. 5. Voltage of power supply must match the voltage of the pump. 6. Before installing pump, clear of any debris or sediment. 7. The following may cause severe damage to pump and will void the warranty. (a) Using an extension cord. (b) Cutting off the ground pin or using an adapter fitting. (c) Working on pump or switch while plugged in. (d) Removing motor housing, unscrewing impeller, or otherwise removing impeller seal. (e) Running the pump continuously. (f) Pumping chemicals or corrosive liquids, other than motor oil. (g) Pumping gasoline or other flammable liquids (h) All piping must be clean and free of all foreign matter to prevent clogging. ( l ) Pump will be inadequate if suspension liquids contain solid particles larger than 1/4. ELECTRICAL WIRE CONNECTION Verify that the voltage and frequency of the pump shown on the name plate corresponds to those available on the mains. The installer must make sure that the electric system is grounded in accordance with code. For outdoor use it is necessary to use cable with a length of at least 8. The plug and connection should be protected from water splashes. Before using the pump, always inspect it visually (especially power cable and plug) Do not use pump if it is damaged If the pump is damaged, have it inspected by an authorized service center. Make sure that electric connections are protected from flooding. Protect the plug and the power cable from heat or shape edges. The power cable must be replaced by qualified personnel only. Grounding: The plug of the power cable has a double grounding contact, so that grounding can be performed by simply inserting the plug. OVERLOAD PROTECTION This pump series has a built in thermal protection switch. The pump stops if an overload condition occurs. The motor restarts automatically after it has cooled down. For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561 2

TROUBLESHOOTING CHECKLIST (Caution: shut off power to pump) PROBLEMS PUMP DOES NOT RUN AND MAKES HUMMING SOUND POSSIBLE CAUSES/SOLUTIONS Line circuit breaker is off, or fuse is blown or loose Pump cord is not making contact in receptacle. If all of the above are OK, then the motor could be malfunctioning. PUMP RUNS BUT DOES NOT DELIVER WATER Impeller or volute openings are fully or partially clogged. Remove pump and clean. Pump is air-locked. Start and stop several times by plugging and unplugging cord. Inlet holes in pump base are clogged. Remove pump and clean the openings. Vertical pumping distance is too high. Reduce distance or change the discharge fittings of the pump. PUMP RUNS BUT ONLY DELIVERS A SMALL AMOUNT OF WATER FUSE BLOWS OR CIRCUIT BREAKER TRIPS WHEN PUMP STARTS MOTOR RUNS FOR A SHORT TIME, THEN STOPS Pump is air-locked. Start and stop several times by plugging in and unplugging cord. Vertical pumping distance is too high. Reduce distance or change the discharge fitting of the pump. Remove pump and clean the strainer and openings. Impeller or volute openings are fully or partially clogged. Remove pump and clean. Pump impeller is partially clogged with tar or paint, causing motor to run slow and overload. Remove pump and clean. Pump impeller is partially clogged causing motor to run slow and overload. Remove pump and clean. Motor stator may be defective. Fuse size or circuit breaker may be too small. (must be 15 amps). Impeller or volute opening are fully or partially clogged. Remove pump and clean. Inlet holes in pump base are clogged. Remove pump and clean the openings. Pump impeller is partially clogged causing motor to run slow and overload. Remove pump and clean. Motor stator may be defective. Impeller or volute openings are fully or partially clogged. Remove pump and clean. Also clean the strainer if one is installed. ELECTRICAL PRECAUTIONS Before servicing a pump, always shut off the main power breaker and then unplug the pump. Make sure you are not standing in water and are wearing insulated protective sole shoes, under flooded conditions. Contact your local electric company or a qualified licensed electrician for disconnecting electrical service prior to pump removal For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561 3

For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561