SANUPS. Non Toxic Lead-Acid Batteries Online UPS. Maintenance-free for 10 Years. Compact and Lightweight. Constant, Stable-Quality Power Supply

Similar documents
Hybrid UPS Saves Energy and Achieves High Reliability. Output capacity. 3 kva. 2 kva. Output capacity. 2.1kW. 1.4kW

PARALLEL PROCESSING UPS E33A

Low energy, high quality, high reliability

Eco Products Beijing Branch Indonesia Representative Office Busan Branch Tianjin Branch Chengdu Branch

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Development of the Small-Capacity UPS SANUPS A11K Series

Development of Small-capacity OFF-LINE UPS

TECHNICAL DATA SHEET KVA UPS Systemss

Technical data sheets

3 Uninterruptible Power Systems

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

3 Uninterruptible Power Systems

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

POWER kva

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

On-line, Single Phase, Double Conversion UPS

POWER kva

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

EFFEKTA Power Supplies

POWERTRONIX QUASAR 5-40 KVA

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

M TYPE S US1D200. For Stepping motor. Instruction Manual

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Liebert PowerSure PSI UPS

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

Uninterruptible Power Systems

Sola/Hevi-Duty S3K Series Mini-Tower UPS

ELEKTRA SERIES I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 500KVA (3/3) Mission Critical & I.T Grade UPS

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

PowerValue 11/31 T kva

Development of Uninterruptible Power Supply SANUPS A11J Three-phase, Four-wire Model

MKN-DSP SERIES - THREE PHASE

Power+ CLASSIC. 20/30 kva, 3x208 Vac

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Development of the SANUPS P73K Power Conditioner with Peak Power Cut Function

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

ConceptpowerTM Modular kVA

Technical Data Sheets

Onfiniti. 1 Phase UPS

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Uninterruptible Power Systems

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.0 GENERAL

Series 120/120VAC Universal Tower/Rack Mount

Industrial PFC UPS System

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

» Sophisticated» Reliable» Intelligent

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

TLE Series UPS 400/500 kw With eboost Technology

Master Plus kva

Uninterruptible Power Supplies

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Uninterruptible Power Systems

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

TLE Series UPS 160/200/225/250 kw with eboost Technology

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Illuminator Series CR NEMA 3R

Technical data sheets

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Application. Battery. Public Grid GS HYBRID INVERTER

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

3 Uninterruptible Power Systems

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Liebert GXT-MT 1-3kVA UPS. Power Protection for Business Critical Continuity

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Technical Data Sheets

Technical Data Sheets

Liebert GXT & 6000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

Technical Data Sheets

Development of Power Conditioner with a Lithium Ion Battery

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

1. Important Safety Warning

Transcription:

ON LINE UPS

Non Toxic Lead-Acid Batteries Online UPS SANUPS ON LINE UPS With Nickel-Hydrogen Battery Online UPS Supporting Network 19-inch Rack Mountable JIS/EIA 100V model Input AC100, 110, 115, 120V Single-phase 200V model Input AC200, 220, 230, 240V Single-phase Output AC100, 110, 115, 120V Single-phase Output AC200, 220, 230, 240V Single-phase 1kVA (0.7kW) 1kVA (0.8kW) Capacity Capacity 1.5kVA (1.05kW) 1.5kVA (1.2kW) UL1778 (E226092), CE, FCC Part15 Subpart B Class A 12 min. 18 min. Standard Standard 1kVA 1.5kVA Battery backup time * UL/CE certified models are available only in AC100V input and output/1.5kva model. See the model list on page 6. Maintenance-free for 10 Years Compact and Lightweight Constant, Stable-Quality Power Supply Easy and Reliable Sequential System Start and Stop Vertical Installation Includes support brackets. Mounted in a 19-inch rack 19 inch rack installation brackets and rack support rail is optional. 2

Maintenance-free for 10 Years First UPS of its class featuring a nickel-hydrogen battery. Twice the battery life of the existing model (10-year life expectancy at 25 C). Also UPS unit life expectancy of 10 years. Existing model UPS unit and cooling fan Batteries 5-year 7-year life expectancy 7-year life expectancy SANUPS A11G-Ni UPS unit and cooling fan, batteries 10-year life expectancy 0 5 10(year) Compact and Lightweight 50% reduction in volume and 14 kg (31 lbs) reduction in weight compared with the existing model*. 50% Reduction 4U Existing model (1.5kVA) SANUPS A11G-Ni (1.5kVA) 2U Existing model (1.5kVA) SANUPS A11G-Ni (1.5kVA) 14kg Reduction *Comparison based on identical backup time. 3

Constant, Stable-Quality Power Supply The online UPS supplies continuous, high quality power at a constant voltage and frequency. Continuous power is supplied even in the event of power interruptions, voltage sags, or transients. No device malfunctions due to waveform distortion. Example of power supply trouble Constant voltage, constant frequency, uninterruptible power supply Momentary power interruption Voltage fluctuation Frequency fluctuation Harmonic noise Online UPS Momentary power failure caused by thunderbolt, etc. Output voltage fluctuates when the load capacity increases as the result of connecting other loading device or when any abnormality occurs in the commercial power source. Frequency deviation occurs when operation of power generating equipment such as engine generator becomes unstable. Momentarily increased voltage caused by turning on/off switch, generates the harmonic noise in the power input line. Commercial Power SANUPS A11G-Ni Device Easy and Reliable Sequential System Start and Stop Start-up and shut-down sequences can be easily controlled for devices that have critical power-on/off sequences, such as hard disks and servers. *In the case of the 200 V model, control outputs 1 and 2 are simultaneously active. [Setting example] SANUPS A11G-Ni Start UPS 15 seconds later Start 30 seconds later Start Constantly operating Continuous power supply Control output 1 Control output 2 4

Front Input Indicator Output Indicator Inverter Switch (ON / Stand by the Inverter Operation) Clear Switch (Stop the alarm) Setting switch Alarm Indicator Battery Housing Base Battery Low Voltage Indicator Load Level Indicator Back Option card slot ON/OFF switch Remote Switch Interface Input Cable (1.8 m / 70.87 in) Option Card Interface PC Interface (RS-232C&UPS Service) DIP Switch (for setting voltage, etc.) 100V model UPS Output (Commercial power supply when the inverter switch is OFF) UPS Output (Power supply is stopped when the inverter switch is OFF) INPUT/OUTPUT Connection Chart Output capacity Model INPUT Plug OUTPUT outlet 100V model 1kVA A11GN102A001 NEMA 5-15P NEMA 5-15R 4 1.5kVA A11GN152A001 200V model 1kVA A11GN102A002 NEMA L6-20P IEC60320-C13 4 1.5kVA A11GN152A002 200V model The photograph shows the 100 V model. Option LAN Interface Card A LAN Interface Card (100Base-TX) can be inserted in the optional card slot. This allows for continuous monitoring and reporting of power conditions, and quick response during power failures. Power problems can also be reported to the System Manager via e-mail when this Card is installed. Model: PRE11A01-US Power Management Software The SANUPS SOFTWARE UPS Power Management Software increases the reliability and manageability of the entire system, including the network and the server. It provides UPS information to the System Manager, and flexible settings for handling power-related problems. Supported OS WINDOWS (Japanese/English) Linux (Japanese/English) UNIX (Japanese/English) 5

Specifications Series name A11G-Ni Notes Item Model (Note5) A11GN102A001 A11GN152A001 A11GN102A002 A11GN152A002 Output capacity 1kVA/0.7kW 1.5kVA/1.05kW 1kVA/0.8kW 1.5kVA/1.2kW Apparent power and active power (Note1) System Topology True On-Line, Double conversion Input rectify system IGBT PWM IGBT Cooling system Forced Air Inverter system High-frequency PWM AC Input Number of phase Single-phase / 2-wire (Note2) Rated Voltage 100/110/115/120 ±15% 200/220/230/240 ±15% Same as output voltage Frequency 50/60Hz ±1,3,5% The fluctuation range is the same as with the output frequency accuracy Required capacity 0.9kVA 1.3kVA 1.0kVA 1.35kVA Maximum capacity when the battery is recharged Power factor >0.95 When the input voltage distortion factor is less than 1% AC Output Number of phase / wire Single-phase / 2-wire Rated Voltage 100/110/115/120V 200/220/230/240V Voltage regulation ±2% Nominal frequency 50Hz/60Hz Same as the input frequency (auto-selection) Frequency range ±1/3/5% (default 3%) The setting can be changed Within ±0.5% during battery operation Voltage Linear load <3% On rated output distortion Non-linear load <7% On rated output Power Nominal 0.7(lag) 0.8(lag) factor Fluctuation range 0.7(lag) to 1.0 Transient 100% step load ±5% On 0-100% change or on output change voltage regulation Power recovery ±5% On rated output Input voltage step ±5% ±10% change Overcurrent protection Automatically switched to the bypass circuit (With auto return function) (Note3) Overcurrent Inverter 105% (200ms) capacity Bypass 200% (30sec.), 800% (2cycle) Battery Type Cylindrical nickel-metal hydrogen battery 10 years life (25 C) Backup time 12min. 18min. 10min.(0.7kW 12min) 15min.(1.05kW 18min) Ambient at 77 F (25 C) Operation Startup on battery This function is supported (Note4) Acoustic noise <40dB At 1 meter from the unit front Nominal heat dissipation 110W 145W 110W 145W Input current leak <3mA Safety Standard Environment UL1778 (E226092), - VCCI classa Operating temperature : 32 to 104 F (0 to 40 C), Relative humidity : 30 to 90% (Non-condensing) - - Note1 : The UL standard rated output capacity of A11GN152A001 is as follows. Output voltage: 1.25 kva/1.05 kw when 100 V is set, 1.35 kva/1.05 kw when 110 V is set, 1.45 kva/1.05 kw when 115 V is set, and 1.5 kva/1.05 kw when 120 V is set. Note2 : When grounding is connected, the grounding phase of the input and output wirings must follow the specification of the equipment. Note3 : The inverter runs in synchronization with the AC input and momentary switching without interruption become possible when the AC input frequency is within range of the rated output frequency accuracy and at the same time when the AC input voltage is within the range of nominal voltage ±15%. Note4 : The normal inverter output can be obtained using the installed battery even if the AC power input source has any abnormalities (power failure or lowered voltage, etc.) Note5 : The model varies depending on the setting of the I/O voltage. I/O voltage Model 1kVA 1.5kVA 100V A11GN102A001 A11GN152A001 110V A11GN102A001-10 A11GN152A001-10 115V A11GN102A001-15 A11GN152A001-15 120V A11GN102A001-20 A11GN152A001-20 200V A11GN102A002 A11GN152A002 220V A11GN102A002-20 A11GN152A002-20 230V A11GN102A002-30 A11GN152A002-30 240V A11GN102A002-40 A11GN152A002-40 Dimensions D H W Input: Power cable with a plug (1.8 m / 70.87 in) Output: Four outlets Painted Color: Ivory (Munsell 6.6Y8.3/0.8) Dimensions: mm (inch) Output capacity Mass: kg (lbs) Width (W) Depth (D) Height (H) 1 19 (42) 410 (16.14) 540 (21.26) 86 (3.39) 1.5 24 (53) 6

Battery backup time Output capacity A11GN102 A11GN152 (W) (min.) (min.) 1200-15* 1050-18 1000-19 900-22 800 10* 26 700 12 31 600 16 38 500 19 46 400 25 55 300 37 76 200 52-100 90 - *Only apply to the 200 V model. Option Item Model Rack mounting brackets (EIA standard) RMASEB02R Used to mount and fasten the UPS to a 19-inch rack. Rack support rail RM014R Used for mounting the UPS onto a 19 inch rack. Remote switch RSW006R Used for remotely turning on or off outlets 1,2 of the UPS by wired control. Contact signal interface card PRASE02R Transmits the operation status of the UPS by contact signals. Use to interface with UPS surveillance systems or customer equipment. Rack support rail Effective dimensions (when the rail is retracted to the minimum) B Effective dimensions (when the rail is extended to the maximum) C A A A B C 86.6 mm (3.41 in) 555 mm (21.85 in) 913 mm (35.94 in) 7

Eco Products Sanyo Denki s ECO PRODUCTS are designed with the concept of lessening impact on the environment in the process from product development to waste.the product units and packaging materials are designed for reduced environmental impact.we have established our own assessment criteria on the environmental impacts applicable to all processes,ranging from design to manufacture.those products that satisfy the criteria are accredited as ECO PRODUCTS. Notes when investigating use of this product in your applications Before starting installation, assembling and use, read the Operation Manual carefully and use the product correctly in your applications. When you are going to use this product in the following application, the special considerations are required for operation, running, maintenance and control. Be sure to consult with our company as a part of your investigations. (a) Medical equipment and other equipment that are related directly to human life. (b) Train or elevator that can give injury to human body. (c) Socially and publicly important computer systems. (d) And other equipment that are related to safety of human life and that can affect severe effects on maintenance of public functions. For the applications that undergo vibration such as vehicles, ships and transportation facilities, please consult with our company. Never modify this product or give additional processing to this product. For the installation andmaintenance work, please consult with our company or with specialized company. http://www.sanyodenki.com 1-15-1, 3-33-1, Kita-Otsuka, Minami-Otsuka, Toshima-ku, Toshima-ku, Tokyo Tokyo, 170-8451, 170-8451, Japan Japan Phone: TEL: +81 3 5927 39171020 5157 468 Amapola Avenue Torrance, CA 90501 U.S.A. Phone: TEL: +1 +1 310 783 5400 P.A. Paris Nord,, 48 Allée des Erables-VILLEPINTE, BP.57286, F-95958 ROISSY CDG Cedex, France Phone: TEL: +33 1 48 4863 6326 2661 61 Frankfurter Strasse 63-69, 92, 65760 65760 Eschborn, Germany Phone: TEL: +49 6196 76113 0 9F 5-2, Sunwha-dong Jung-gu Seoul, 100-130, Korea Phone: TEL: +82 2 773 5623 Rm2108-2109, Rm2107-2109, Bldg A, Far East International Plaza, No.319, Xianxia Rd., Shanghai, 200051, China Phone: TEL: +86 21 216235 1107 Room 1208, 12F, No.96 Chung Shan N, Rd., Sec.2, Taipei 104, Taiwan, R.O.C. Phone: TEL: +886 2 2511 3938 Room 2305, 23/F, South Tower, Concordia Plaza, 1 Science Museum Rd., TST East, Kowloon, Hong Kong Phone: TEL: +852 2312 6250 10, Hoe Chiang Road, #14-03A/04, Keppel Towers, Singapore 089315 Phone: TEL: +65 6223 1071 CATALOG CATALOG No.P0966B002 966-1 10.11.IT 13.8.IT