Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

Similar documents
Milano AUTOMATIC FAUCET

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance

Installation For Service Only

Installation Instructions

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Installation Instructions

Installation IMPORTANT! Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

MAC FAUCETS. FA400 Autoluxe Faucets

Optima ETF-600/ETF-610

Supplies Required. Teflon Tape Allen Key Wrenches Screwdriver 1/2" NPT Brass Pipe Plug Adjustable Wrench IMPORTANT!

MAC FAUCETS FA400 WALL MOUNT FAUCETS

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

AEF-300/300T SERIES SENSOR FAUCET SYSTEMS

Installation S19-220PT S19-220BPT. Wall-Mounted Eyewash with Plastic Bowl. Wall-Mounted Eyewash with Stainless Steel Bowl

MAC FAUCETS. FA400 Wall Mount Sensor

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5

ETF-600 Sensor Operated Lavatory Faucet

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

INSTALLATION INSTRUCTIONS FOR SLOAN SF ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

Basin Set INSTALLATION INSTRUCTIONS

Installation S AST4 S TT S IR. Stainless Steel Wall-Hung BradMate Washfountain

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

Installation. S AST4 S TouchTime S Infrared. Stainless Steel Wall-Hung BradMate Washfountain

Installation Instructions

Installation. ABP-1C TouchTime Ablution System IMPORTANT! Table of Contents Rev. B; ECN E 2014 Bradley Page 1 of 5 10/6/2014

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Installation Instructions

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

Installation Instructions

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

Aqua-FIT Serio Series TM

Installation Instructions

OPERATION & MAINTENANCE MANUAL 5000E Series Faucet

Installation S19-310F. Combination Drench Shower and Eyewash

Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB

DISCONTINUED. Installation S19-310SS16. Stainless Steel Combination Drench Shower and Eyewash. Table of Contents

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Installation S19-310LL. Combination Drench Shower and Eyewash

Alliance Towel Dispensing System. Operation Manual

Installation Instructions

Installation S19-130BF Plastic Showerhead S19-130ABF Plastic Showerhead with Stainless Steel Shroud Drench Shower Vertical Supply Table of Contents

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

DISCONTINUED. Installation S19-310FSS. Stainless Steel Combination Drench Shower and Eyewash

6-12 WIDESPREAD 6-12 W. Cleopatra Series INSTRUCTION GUIDE SAVE THIS INSTRUCTION GUIDE

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

Installation S Freestanding Drench Shower

Installation Instructions

Installation. Tools. Single Handle Kitchen Faucet With Optional Spray. Maintenance. Safety Tips. Important Points. Need Help? For Model:

Installation S19-310NN. Frost-Proof Combination Drench Shower and Eyewash (18", 3', 4', 5' or 6' Bury Depth)

Installation Instructions

G SERIES - E TOUCH MIXER / TAP

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

Installation Instructions

Installation. E19-310AC Combination Drench Shower and Eye/Face Wash. Table of Contents

OBSOLETE. Installation S19-325BF S19-325FBF S19-325PBF S19-325FPBF

Installation S19-130BF S19-130ABF. Drench Shower - Vertical Supply. Table of Contents

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

INSTALLATION INSTRUCTIONS

Installation Instructions Series

Installation Instructions

INSTALLATION INSTRUCTIONS PATIENCE

Installation Instructions

I Button Chemical Dispenser. Overview. Installation Instructions

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

Installation Instructions

Installation Instructions

Installation S19-220BF. Wall-Mounted Eyewash

Sensor Activated Lavatory Faucet Installation, Operation & Service Instructions Model Numbers Tools & Materials Need Help?

Installation Instructions

FOR TECHNICAL ASSISTANCE

Aquatic Access Inc. Pool Lift Model IGAT-180 AD. Installation Guide Instruction Manual

Installation Instructions Series Series

INSTALLATION INSTRUCTIONS

Installation S19-110BF. Freestanding Drench Shower

Operating Manual for Hands-Free Wall Mounted Sinks Models 607D and 607D-0.5

Installation S19-220P. Wall-Mounted Eye/Face Wash. Table of Contents P Rev. P; ECN C 2012 Bradley Page 1 of 5 10/18/2012

Installation. MG-2 Infrared. Express Lavatory System - MG Series with Adaptive Infrared. Table of Contents

INSTALLATION INSTRUCTIONS

Installation S19-315BF S19-315FBF S19-315PBF S19-315FPBF

Installation. S19284H (Eyewash) S19284J (Eye/Face Wash) Cabinet-Mounted Swing-Down Eyewash and Eye/Face Wash. Table of Contents

G2 Optima Plus Flushometer

CAUTION Fuel Lift Pump. Initial Check. Resistance Check.

Installation Instructions

BASYS Infrared Sensor Activated

Installation. S19284HB (Eyewash) S19284JB (Eye/Face Wash) Barrier-Free Cabinet-Mounted Swing-Down Eyewash and Eye/Face Wash.

Installation. S19284HB (Eyewash) S19284JB (Eye/Face Wash) Barrier-Free Cabinet-Mounted Swing-Down Eyewash and Eye/Face Wash.

PeroxiDraw Dispenser

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

INSTALLATION INSTRUCTIONS STUDIO S

Transcription:

Installation erada 1200 Series CS Faucet S53-325 Battery-Operated Capacitive Sensing Gooseneck Faucet Centershank with 4-inch Trim Plate (Optional: 8-inch or No Trim Plate) Table of Contents Supplies Required.................. 2 Installation..................... 4 Manual Settings................... 6 djustments....9 Troubleshooting...10 Care and Maintenance...12 Multi-Faucet Transformer Wiring...14 IMPORTNT Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the installer. Pressurized plumbing fixtures shall be installed in accordance with manufacturer s recommendations. The supply piping to these devices shall be securely anchored to the building structure to prevent installed device from unnecessary movement when operated by the user. Care shall be exercised when installing the device to prevent marring the exposed significant surface. Separate parts from packaging and make sure all parts are accounted for before discarding packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. Make sure that all water supply lines have been flushed and then completely turned off before beginning installation. Do not use pipe dope. Debris in supply lines can cause valves to malfunction. Possible valve contamination could occur which will void any warranty. Teflon tape is the recommended sealant. Product warranties may be found under Products on our web site at www.bradleycorp.com. 215-1641 Rev. E; ECN 16-02-002 2016 Bradley Page 1 of 13 9/7/2016 P.O. Box 309 Menomonee Falls, WI 53052 US 800 BRDLEY (800 272 3539) +1 262 251 6000 bradleycorp.com

S53-325 Installation Components for Model S53-325 Optional C dapters (In Lieu of Battery Box).5 GPM erator Kit - 269-2482 1.5 GPM erator Kit - 269-1957 3' ref. Single Unit dapter (153-443) 6-Unit dapter Box (153-444) Wire ssembly for 6-Unit dapter Box (269-1841) Order One Per Faucet) Spout Gasket (269-1951) Insulator Spacer (Red) M4 x 25mm Screw Top Spacer (269-1952) Top Gasket (269-1953) 5' ref. Grounding Kit (269-1889) Sink Ground Kit (includes ground wires, spout lock washer and nut and sensor washer) Earth Grounding Wire Sensor Washer 4" Trim Plate Kit (269-1955) included 8" Trim Plate Kit (269-1956) Optional 3-in-1 Washer (269-1911) Shank Nuts Battery Box (S08-386) Drain Grounding Wire Black Sensor Wire Valve Control Module Valve Control Module Kit (153-447) includes: Control Module Grounding Kit Dirt Filter 1/2" NPS x 1/2" NPS x 12" hose included (4) lkaline Batteries included 2 9/7/2016 Bradley 215-1641 Rev. E; ECN 16-02-002

Installation S53-325 1 ttach Faucet and Trim Plate to the Deck Drill two 3/8" (9.5mm) diameter holes. Drill 1" (25mm) diameter hole. Sink/Counter Top Trim Plate Studs B ttach trim plate studs and secure trim plate to sink using metal washers and hex nuts. Optional Trim Plate Removal Remove and discard long trim plate screws and white plastic screw spacers. Gasket and Faucet Spacers Trim Plate B fter removing trim plate, re-attach gaskets and faucet spacer using shorter M4 x 12mm screws (supplied). Do not re-install screw spacers. Red Plastic Screw Spacers Long Trim Plate Screws Short Trim Plate Screws Bradley 215-1641 Rev. E; ECN 16-02-002 9/7/2016 3

S53-325 Installation 2 ttach ctivation Hardware to Faucet Shank Tab on 3-in-1 washer must be positioned 180 degrees opposite tab on sensor connection washer. ttach B ttach grounding hardware to shank in the order shown. activation hardware to shank in the order shown. 3-in-1 Washer Brass Mounting Nut Sensor Wire Connection Washer Brass Mounting Nut 3 Connect the Valve Control Module Place rubber washer into white top nut fitting. B Hand tighten valve control module to faucet shank. 4 9/7/2016 Bradley 215-1641 Rev. E; ECN 16-02-002

Installation S53-325 4 Connect Sensor Wire Connect sensor wire to sensor wire connection washer. Sensor Wire Connection Washer Black Sensor Wire 5 Connect Sink Ground Wire Connect sink/drain ground wire to sink grounding tab washer. Sink Grounding Tab Washer For applications without a trim plate, cut off the ring terminal side and discard. The remaining portion of wire can be taped to the sink ground wire using electric tape. For applications using trim plate, refer to Step C. Ring Terminal Side Sink Ground Wire C Place ring on terminal side on one of the threaded studs and fasten with lock washer and nut. B Connect this end of sink ground wire to one tab on U-tab connection. U-Tab Connection D ttach drain wire clamp to sink drain. Bradley 215-1641 Rev. E; ECN 16-02-002 9/7/2016 5

S53-325 Installation 6 Install Earth Ground ssembly Connect earth grounding clamp to cold water supply between shut off valve and wall plate. Be sure to attach directly to the copper pipe and not to the shut off valve. B Connect earth grounding connector to remaining terminal on U-tab connector. 7 Install and Connect Battery Pack For installations using optional C power source, connect power source as shown in Step C. Valve Control Module Power Connection C Connect battery box connector (or C power connector) to valve control module power connection. Remove battery box cover by unscrewing (2) phillips screws. Battery Box Connector (or C Power connector) B Secure battery compartment to wall using wall anchors or double-sided tape. Insert (4) d-cell alkaline batteries and replace cover. 6 9/7/2016 Bradley 215-1641 Rev. E; ECN 16-02-002

Installation S53-325 Troubleshooting Guide Problem Cause Solution Batteries not inserted correctly. Faucet not working (no flashing red indicator located inside clear cover of valve control box). Faucet not working and no water flows when activated (red indicator is flashing). Intermittent cycling and/ or water runs on after activation. Intermittent cycling and/or faucet activation is overly sensitive. Water stays on or runs on after you pull your hand away. Water stays on. Water is dripping from spout when not activated. Improper or poor connection to power supply. Low batteries. Water source valves turned off. Sensor shorted to ground or unit unable to calibrate. Improper ground connection. Broken or corrupt sensor wire or defective valve box electronics. Poor sensor washer and wire connection. Insufficient ground connection. Isolation parts are not installed or not installed correctly. Drain grounding not connected or assembled. There is sensor short to ground or unit is not calibrating. Dial set to the "open" position or not turned to the full "auto" position. Debris or particulate matter is trapped in valve. Dial not turned to the full "auto" position. Remove cover from battery box and check that the batteries have been inserted to the correct orientation and are making connections to the contacts. Refer to the battery icons located on the base of the battery box tray. Check that the connection from the battery box is fully inserted into the female connector on the valve control box and assure the connector round thumbnut is fully fastened. If red indicator is flashing 5 times every 4 seconds, replace with new alkaline batteries. Open water source valves and check that there is water flow. If red indicator is flashing once or multiple times every 4 seconds, there is a problem with the installation and the sensor is shorted. To verify the control box is working correctly, carefully disconnect the black sensor wire from the connection washer. With the wire disconnected, touch the connector at the end of the black wire with your fingers. The sensor should activate and water should come on. Let go of the connector and the water should shut off. If the unit works as described above and it malfunctions when you reconnect the black sensor wire to the spout assembly, then there is an error in the spout and cover plate installation. If the faucet does not activate as described when touching the sensor connector, then you have a grounding issue or there is a broken sensor wire (see troubleshooting below). There is improper earth grounding if the faucet activates when you touch any of the steel braided supply hoses, the brass fitting on the valve box or the mixing valve. Verify that the ground clamp has been installed and recheck the connections. Verify the clamp is tightly fastened directly to the copper pipe for a proper ground connection. Reset the unit following procedure below.* If the connector has broken off of the black sensor wire or the valve box appears to be defective please contact Bradley Technical Service. Do not attempt to repair the valve box or sensor wire. Verify the brass nuts that fasten the connection washer are fully tightened. Reconnect the sensor wire to the washer. Reset the unit following procedure below.* Verify that the earth ground clamp has been installed and recheck the connections. Verify the clamp is tightly fastened directly to the copper pope for a robust ground connection. Reset the unit following procedure bellow.* If the faucet activates when you touch the sink, the unit installation is improper. Check that isolation components are used and installed correctly. Verify the sink ground connection is in place and installed properly. Check that the drain ground is assembled to the threaded portion of the metal drain ring (not on the pipe) and is connected to the tab on the valve control box. Reset the unit following the procedure below.* Reset the unit following the procedure below.* If water continues to run, there is an error in the installation and grounding scheme (see above). Turn the knob on the side of the valve control box fully to the "auto" position (until it hits the stop) and actuate the faucet by placing your hand near the spout. Water should stop running and unit will return to the normal idle operation mode once you remove your hand from the spout. Turn off water source valves. Remove aerator from end of the spout and examine for dirt and particulates. Inspect and clean input dirt filter. Reinsert filter and turn water source back on. ctivate faucet several times without the aerator installed to flush any debris from the valve mechanism until dripping has ceased. Reinstall aerator. Turn the knob on the side of the valve control box fully to the "auto" position (until it hits the stop) and activate the faucet several times by placing your hand near the spout. Water should stop running or dripping and unit will return to the normal idle operation mode once hand is removed from the spout. *How to rest the Unit: Disconnect power source for 10 seconds. The valve will close and the water will stop running. fter 10 seconds, reconnect power supply. let until recalibrate for another 20 seconds and verify faucet activation. Bradley 215-1641 Rev. E; ECN 16-02-002 9/7/2016 7

S53-325 Installation Faucet djustments Operating modes and sensor ranges can be adjusted with a manual operation through the infrared sensor. Faucet adjustment operations apply to all models. Operating Modes Operating Modes Cleaning Mode Normal Mode Metering Mode (10 s) Scrub Mode (60 s) Scrub Mode (180 s) Sensor Range djustment Reset The faucet is inactive for 90 seconds. Description The faucet is activated if it senses a hand presence. This is the default operating mode of the faucet. The faucet will shut off after 10 seconds regardless of hand presence detected. The faucet will shut off 60 seconds after the detection of the last hand presence. The faucet will shut off 180 seconds after the detection of the last hand presence. Change the detection distance of the infrared sensor. The default sensor range is approximately 1 beyond the spout. ll settings will be reset to original factory settings. In order to set the operating modes, the faucet needs to be placed into "Manual Setting" mode. t this time, operating modes can be changed within the next 30 minutes. The following is a functional diagram to show the different settings available for manual faucet adjustment. See detailed instructions on pages 5 through 7. Function Diagram of Operating Modes Cleaning Mode Modes Normal Mode Metering Mode (10 seconds) Scrub Mode (60 seconds) Scrub Mode (180 seconds) Sensor Range djustment Water Pulses in Second(s) 5 4 1 4 1 4 1 4 1 4 1 Water is Off Water is On 8 9/7/2016 Bradley 215-1641 Rev. E; ECN 16-02-002

Installation S53-325 Troubleshooting Problem Possible Cause Solution No water flow Supply valves are closed Open supply valves erator is blocked or dirty Inlet water line filter is dirty or blocked Braided hose is kinked No external water pressure Battery is drained (DC faucets only) Battery contacts are corroded (DC faucets only) Reverse battery insertion Connector between transformer and power adapter unplugged (C faucets only) Power adapter contacts are corroded (C faucets only) Connecting cable is kinked or broken (C faucets only) No external power supply (C faucets only) Shut-off screw is missing or defective Solenoid valve inoperable Faucet is in cleaning mode Electronics module inoperable Power adapter defective (C faucets only) Sensor distance is not adjusted properly Infrared window scratched or dirty Clean or replace aerator (See "Care and Maintenance") Clean or replace filter (See "Care and Maintenance") Eliminate braided hose kink Check water pressure/provide water pressure Replace battery (See "Care and Maintenance") Clean contacts or replace battery Insert battery correctly Plug connector Clean contacts Replace defective parts (See "Replacement Parts") Check external power supply/provide power supply Replace shut-off screw (See "Replacement Parts") (See "Care and Maintenance") Replace solenoid valve (See "Replacement Parts") Wait for cleaning mode to end (appr. 90 seconds) Contact Bradley technical service or replace power adapter (See Replacement Parts ) Contact Bradley technical service or replace power adapter (See Replacement Parts ) Reset sensor monitoring range Remove and re-install shut-off screw. Do not disturb sensor scanning procedure (wait until water flow stops and LED switches off) Clean window with smooth cloth Bradley 215-1641 Rev. E; ECN 16-02-002 9/7/2016 9

S53-325 Installation Problem Possible Cause Solution Water runs continuously and stops when object present Connector between electronics module and solenoid valve plug is reversed Plug connector properly Water runs continuously Water flows although shut-off screw is removed Faucet turns on by itself Faucet is leaking water Temperature cannot be adjusted properly Interfering object is in monitoring range Defective electronics module Improper sensor mode External water pressure too high Solenoid valve inoperable Electronics module is inoperable Water drops on infrared window Infrared window is dirty or scratched Input line pressure fluctuates Connections between housing and braided hoses are loose Connection between braided hose and inlet supply are loose Connection between valve body and solenoid valve is loose Faucet drips, solenoid valve does not close properly No, or too little hot or cold water. Supply valves are not fully opened Inlet water line filter is dirty or blocked Braided hose is kinked Backflow preventer in faucet inlet is blocked Temperature of hot or cold water supply is too low Hot water temperature not sufficient Braided hoses are connected improperly (cold to hot and hot to cold) Remove object from monitoring area Remove and re-install shut-off screw. Do not disturb sensor scanning procedure (wait until water flow stops and LED switches off) Replace electronics module (See Replacement Parts ) Change mode or reset sensor (See Care and Maintenance ) Check external water pressure Provide pressure between 20-125 psi Replace solenoid valve (See Replacement Parts ) Replace electronics module (See Replacement Parts ) Clean window with smooth cloth Clean window with smooth cloth Install appropriate line pressure regulators Check O-rings Replace O-rings when damaged or missing Check rubber washers Replace washers when damaged or missing Check O-rings Replace O-rings when damaged. Carefully reinstall solenoid valve and do not overtighten. Clean or replace solenoid valve (See Replacement Parts ) Fully open supply valves Clean or replace filter (See Care and Maintenance ) Eliminate braided hose kink Unblock backflow preventer Check inlet water temperature or inspect boiler Reverse hot water limiter (See Care and Maintenance ) Correct the connections 10 9/7/2016 Bradley 215-1641 Rev. E; ECN 16-02-002

Installation S53-325 Care and Maintenance The following are described in this section: ctivating Cleaning Mode Replacing Battery Cleaning or Replacing Inlet Filter djusting Water Temperature (Internal Mixer) djusting Hot Water Limiter (External mixer) Cleaning or Replacing erator ctivating Cleaning Mode In order to set the cleaning mode, the faucet needs to have been set once into the "Manual Setting" mode. See "Manual Setting" instructions. When cleaning mode is activated, the faucet will be inoperable for 90 seconds. 3 Remove housing vertically. 4 Remove used battery from battery holder and recycle. 1 Fully cover sensor with hand until water flow stops. This takes approximately 5 seconds. 2 Remove hand. Cleaning Mode is now activated. 5 Insert new battery. The LED lights up for 1 second. Replacing Battery traditional lavatory faucet is shown as an example. These instructions apply to all DC models. Before replacing the batter, be sure that: Battery is low (LED is lit) New 6 V Lithium battery (CR-P2) is required 1 Remove shut-off screw. 6 Mount housing vertically. 2 Remove mixer handle (for faucets with external mixer only). Bradley 215-1641 Rev. E; ECN 16-02-002 9/7/2016 11

S53-325 Installation 7 Install shut-off screw. djusting Hot Water Limiter (External Mixer) The proportion of hot water can be switched from approximately 85% to 95% (or reverse) depending upon inlet water pressures and temperatures. The default setting is 85%. CUTION Hot water may burn skin. Hold hand carefully under water and remove quickly. 1 Remove mixer handle. 8 Install mixer handle (for faucets with external mixer only). 2 Carefully pull out hot water limiter from handle (using pliers) and reverse by 180. Cleaning or Replacing Inlet Filter 1 Close supply valves. 180 Settings of hot water limiter (view from placement in mixer handle) 2 Disconnected braided hoses and clean or replace filter. For a new filter, see Replacement Parts section. 85% 95% 3 Mount mixer handle. The proportion of hot water is now changed. 3 Connect braided hose with filter to supply valve. Cold water = White Label Hot Water = No Label 12 9/7/2016 Bradley 215-1641 Rev. E; ECN 16-02-002

Installation S53-325 Cleaning or Replacing erator 1 Remove shut-off screw. 3 Install shut-off screw. 2 Remove aerator with vandal resistant wrench supplied with the faucet. Clean or replace aerator, then reinstall. Multi-Faucet Transformer C Connector from Faucet Bank Installation dapter Wire Bank Installation dapter Wire (Incl. w/ C Faucet) 232-009 (1 8 faucets) Transformer can be used to connect up to 8 faucets. ll units must be connected in parallel. dditional Wiring, if needed, To be Supplied by Customer (22 G min; 50 ft. max. length) Bradley 215-1641 Rev. E; ECN 16-02-002 9/7/2016 13