REVIEW PAPER ON INVESTIGATION OF PERFOMANCE FOR SHELL AND TUBE HEAT EXCHANGER

Similar documents
Efficiency Improvement in Shell and Tube Heat Exchanger Using CFD Tool

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

Performance Evaluation Of A Helical Baffle Heat Exchanger

Design and Fabrication of Shell and Tube Type Heat Exchanger and Performance Analysis

EXPERIMENTAL INVESTIGATIONS OF DOUBLE PIPE HEAT EXCHANGER WITH TRIANGULAR BAFFLES

Thermal Analysis of Shell and Tube Heat Exchanger Using Different Fin Cross Section

A Review on Experimental Investigation of U-Tube Heat Exchanger using Plain Tube and Corrugated Tube

Experimental Study on Heat Enhancement of Helixchanger with Grooved Tubes

CFD Analysis to Study the Effects of Inclined Baffles on Fluid Flow in a Shell and Tube Heat Exchanger

Design of Shell and Tube Type Heat Exchanger using CFD Tools

Enhance the Performance of Heat Exchanger with Twisted Tape Insert: A Review

ABSTRACT I. INTRODUCTION III. GEOMETRIC MODELING II. LITERATURE REVIW

CFD analysis of heat transfer enhancement in helical coil heat exchanger by varying helix angle

CONJUGATE HEAT TRANSFER ANALYSIS OF HELICAL COIL HEAT EXCHANGE USING CFD

THERMAL ANALYSIS OF HELICALLY GROOVED COIL IN A CONCENTRIC TUBE HEAT EXCHANGER

Design Optimization of Cross Flow Heat Exchanger

Review on Comparative Study between Straight Tube Heat Exchanger and Helical Coil Heat Exchanger

Simulation Studies on the Effect of Porous Twisted Plate Inserts on the Performance of Fire Tube Steam Packaged Boiler

GEOMETRICAL PARAMETERS BASED OPTIMIZATION OF HEAT TRANSFER RATE IN DOUBLE PIPE HEAT EXCHANGER USING TAGUCHI METHOD D.

SOLAR FLAT PLATE COLLECTOR HEAT TRANSFER ANALYSIS IN THE RAISER WITH HELICAL FINS Mohammed Mohsin Shkhair* 1, Dr.

International Journal of Advance Engineering and Research Development

Enhanced Heat Transfer Surface Development for Exterior Tube Surfaces

ENHANCEMENT OF HEAT TRANSFER RATE AND REDUCTION OF SHELL SIDE PRESSURE DROP IN HELIX HEAT EXCHANGER WITH CONTINUOUS HELICAL BAFFLES

COMPUTATIONAL ANALYSIS TO MAXIMIZE THE HEAT TRANSFER RATE OF DOUBLE TUBE HELICAL COIL HEAT EXCHANGER

Comparison of Swirl, Turbulence Generating Devices in Compression ignition Engine

CFD ANALYSIS ON LOUVERED FIN

Comparative Study of Different Configurations of Fuel Oil Heat Exchanger

CFD analysis of triple concentric tube heat exchanger

International Journal of Engineering Research and General Science Volume 5, Issue 3, May-June, 2017 ISSN

Corresponding Author, Dept. of Mechanical & Automotive Engineering, Kongju National University, South Korea

CFD Analysis and Comparison of Fluid Flow Through A Single Hole And Multi Hole Orifice Plate

Effect of Baffle Geometry on Shell and Tube Heat Exchanger-A Review Hardik Tandel 1 Pankaj Ahir 2 Asst. Prof. Y. D. Vora 3

International Journal of World Research, Vol: I Issue XXXVII, January 2017 Print ISSN: X

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

PERFORMANCE ANALYSIS OF DIFFERENT HEAT EXCHANGER DESIGN USING CFD SIMULATION 1 KVENUMADHAV 2 SUDHANSHU KUMAR

Modeling and Fluid Flow Analysis of Wavy Fin Based Automotive Radiator

THERMAL ANALYSIS OF SHELL AND TUBE HEAT EXCHANGER

Design and Performance Analysis of Louvered Fin Automotive Radiator using CAE Tools

A comparative analysis to enhance the effectiveness of EGR coolers used in diesel engine

An Overview of Shell & Tube Type Heat Exchanger Design by Kern s Method

Experiment No: 2. To determine the effectiveness of shell and tube, cross flow & plate heat exchangers. Heat Exchangers. Plate-type Extended surfaces

Analysis of Air Flow and Heat Transfer in Ventilated Disc Brake Rotor with Diamond Pillars

CFD Analysis of Double Pipe Heat Exchanger with Twisted Tape Insert in Inner Pipe

Experimental Study of Heat Transfer Augmentation in Concentric Tube Heat Exchanger with Different Twist Ratio of Perforated Twisted Tape Inserts

Abstract In this study the heat transfer characteristics inside a rectangular duct with circular, rectangular, drop

Experimental Analysis and Performance Characteristic Of Heat Transfer In Shell and Twisted Tube Heat Exchanger.

CFD Analysis of Heat Transfer Prediction for Corrugated Shell & Tube Heat Exchanger

Research Article Thermohydraulic Analysis of Shell-and-Tube Heat Exchanger with Segmental Baffles

Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

A REVIEW ON INVESTIGATION OF HELICAL COIL HEAT EXCHANGER

AN OVERVIEW OF SHELL AND TUBE HEAT EXCHANGER PERFORMANCE

CFD Integrated Optimum Design and Prototyping of Shell and Tube Heat Exchanger

Scroll Compressor Oil Pump Analysis

EXPERIMENTAL ANALYSIS AND PERFORMANCE CHARACTERISTIC OF HEAT TRANSFER IN SHELL AND TWISTED TUBE HEAT EXCHANGER

Numerical Study on the Flow Characteristics of a Solenoid Valve for Industrial Applications

Exhaust Gas Waste Heat Recovery and Utilization System in IC Engine

IJESR/Oct 2012/ Volume-2/Issue-10/Article No-12/ ISSN International Journal of Engineering & Science Research

Investigation of Comparison of Three Different Tube Bundles of Heat Exchanger

Quality Improvement in Design Process of Shell & Tube Type Heat Exchanger by Computer Integrated 3D Modeling

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 05, 2014 ISSN (online):

Numerical Analysis of Compact Heat Exchanger for Flow Distribution

Design and experimental analysis of pipe in pipe heat exchanger

Chapter 7: Thermal Study of Transmission Gearbox

ADVANCES in NATURAL and APPLIED SCIENCES

Vibration Measurement and Noise Control in Planetary Gear Train

CFD ANALYSIS OF DOUBLE HELICAL PIPE PARALLEL& COUNTER FLOW HEAT EXCHANGER

Thermal Analysis Of Counter Flow Shell And Tube Heat Exchanger

Department of Mechanical Engineering, D Y Patil College of Engineering, Akurdi, Pune , Savitribai Phule Pune University, India

CFD Analysis of Oil Discharge Rate in Rotary Compressor

DESIGN OPTIMIZATION OF SHELL AND TUBE HEAT EXCHANGER FOR OIL COOLER BY COMSOL MULTIPHYSIS

NOVATEUR PUBLICATIONS INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT] VOLUME 1, ISSUE 1 NOV-2014

THERMAL ANALYSIS OF PISTON BLOCK USING FINITE ELEMENT ANALYSIS

NUMERICAL ANALYSIS OF HELICALLY COILED HEAT EXCHANGER USING CFD TECHNIQUE

Effect of concave plug shape of a control valve on the fluid flow characteristics using computational fluid dynamics

Heat Transfer in Rectangular Duct with Inserts of Triangular Duct Plate Fin Array

International Journal of Advance Engineering and Research Development

Back pressure analysis of an engine muffler using cfd and experimental validation

NUMERICAL INVESTIGATION OF FLUID FLOW AND HEAT TRANSFER CHARACTERISTICS ON THE AERODYNAMICS OF VENTILATED DISC BRAKE ROTOR USING CFD

Experimental Investigation of Heat Transfer characteristics Enhancement through Grooved Tube

EFFECT OF EXTERNAL THREADED INSIDE TUBE ON HEAT TRANSFER RATE IN A CONCENTRIC TUBE HEAT EXCHANGER: A CRITICAL REVIEW

PERFORMANCE AND EMISSION ANALYSIS OF DIESEL ENGINE BY INJECTING DIETHYL ETHER WITH AND WITHOUT EGR USING DPF

Study the Effect of Single Segmental Baffle cut on Overall Heat Transfer Coefficient in Shell and Tube Heat Exchanger

Comparison of Heat transfer Enhancement in Tube in Tube heat exchanger using Different Turbulent Generator.

Analysis to Determine Heat Transfer Using Twisted Tape Inserts In a Horizontal Tube

Design and Performance Study of Shell and Tube Heat Exchanger with Single Segmental Baffle Having Perpendicular & Parallel-Cut Orientation.

NUMERICAL INVESTIGATION OF PISTON COOLING USING SINGLE CIRCULAR OIL JET IMPINGEMENT

Experimental investigation of shell-and-tube heat exchanger with different type of baffles

CFD Study to Enhance the Heat Transfer in Heat Exchanger by Change the Outer Surface of the Inner Tube and Use Nano Fluid

FLOW AND HEAT TRANSFER ENHANCEMENT AROUND STAGGERED TUBES USING RECTANGULAR VORTEX GENERATORS

Design, Fabrication and Testing of helical tube in tube coil heat exachanger

Numerical Simulation on Erosion of Drain Valve Liangliang Xu1,a, Zhengdong Wang2,b, Xinhai Yu3,c, Cong Zeng4,d

Automation of Optimal Design of Air Preheater s Corrugated Heating Elements using CFD

The Practical Uses of Computational Fluid Dynamics Not Just a Pretty Picture

FEM Analysis of Combined Paired Effect on Piston & Connecting Rod using ANSYS

DESIGN AND ANALYSIS OF EXHAUST VALVE SPRINGS IN IC ENGINES

HEAT TRANSFER OPTIMIZATION OF SHELL AND TUBE HEAT EXCHANGER THROUGH CFD ANALYSIS

Structural Analysis of Pick-Up Truck Chassis using Fem

International Journal of Advance Engineering and Research Development

Investigation for Flow of Cooling Air through the Ventilated Disc Brake Rotor using CFD

INVESTIGATION OF HEAT TRANSFER CHARACTERISTICS OF CIRCULAR AND DIAMOND PILLARED VANE DISC BRAKE ROTOR USING CFD

Transcription:

aerd Scientific Journal of Impact Factor(SJIF): 3.134 International Journal of Advance Engineering and Research Development Volume 2,Issue 3, March -2015 e-issn(o): 2348-4470 p-issn(p): 2348-6406 REVIEW PAPER ON INVESTIGATION OF PERFOMANCE FOR SHELL AND TUBE HEAT EXCHANGER Sachin k.patel. 1, A.R.Patel 2 1 PG Student (Thermal Engineering), Mechanical Engineering Department, L DRP Institute of Technology & Research, Gandhinagar, Gujarat 2 Professor, Mechanical Engineering Department, L DRP Institute of Technology & Research, Gandhinagar, Gujarat. Abstract The following review paper shows the different major analysis done by several researchers in the topic of Shell and tube type of heat exchanger. To increase the capacity of heat exchanger is invite the optimization problem which seeks to identify the best parameter combination of heat exchangers.in order to tackle such an optimization problem in present work the optimization technique is applied to perform screening of experiments and to identify the important significant parameters which are affecting the effectiveness of shell and tube type heat exchanger. According to our review we find that majority of the researches used The prefix parameters (tube diameter, mass flow rate and pitch length,baffle angle etc.)are used as input variable and the output parameter is maximum temperature difference of shell and tube heat exchanger. Key words: Heat exchangers I. INTRODUCTION A heat exchanger is a device built for efficient heat transfer from one medium to another. The media may be separated by a solid wall, so that they never mix, or they may be in direct contact. They are widely used in space heating, re frigeration, air conditioning, power plants, chemical plants, petrochemical plants, petroleum refineries, natural gas processing, cryogenics applications and sewage treatment. One common example of a heat exchanger is the radiator in a car, in which the he at source, being a hot engine-cooling fluid, water, transfers heat to air flowing through the radiator (i.e. the heat transfer medium). Introduction of shell & tube Heat exchanger Shell and tube heat exchangers consist of a series of tubes. One set of thes e tubes contains the fluid that must be either heated or cooled. The second fluid runs over the tubes that are being heated or cooled so that it can either provide the heat or absorb the heat required. A set of tubes is called the tube bundle and can be made up of several types of tubes: plain, longitudinally finned, etc. Shell and tube heat exchangers are typically used for high-pressure applications (with pressures greater than 30 bar and temperatures greater than 260 C). This is because the shell and tube heat exchangers are robust due to their shape. Fig 1. A Shell and Tube heat exchanger Flow Arrangement @IJAERD-2015, All rights Reserved 552

Fig 2. Counter current (A) and parallel (B) flows There are two primary classifications of heat exchangers according to their flow arrangemen t. In parallel-flow heat exchangers, the two fluids enter the exchanger at the same end, and travel in parallel to one another to the other side. In counter-flow heat exchangers the fluids enter the exchanger from opposite ends. The counter current design is most efficient, in that it can transfer the most heat from the heat (transfer) medium. See counter current exchange. In a cross-flow heat exchanger, the fluids travel roughly perpendicular to one another through the exchanger. For efficiency, heat exchangers are designed to maximize the surface area of the wall between the two fluids, while minimizing resistance to fluid flow through the exchanger. The exchanger s performance can also be affected by the addition of fins or corrugations in one or both directions, which increase surface area and may channel fluid flow or induce turbulence. The driving temperature across the heat transfer surface varies with position, but an appropriate means temperature can be defined. In most simple systems this is the lo g mean temperature difference (LMTD). Sometimes direct knowledge of the LMTD is not available and the NTU method is used II. LITERATURE REVIEW O F SHELL AND TUBE HEAT EXCHANGER. P.S..Gowthaman et al [1], In this paper The work done on the analysis of Segmental and Helical baffle in a heat exchanger and They shows the higher heat transfer and lower Pressure drop is achieved in a helical baffle compare to segmental baffle A virtual model of helical and segmental baffle was Created in a PRO E and analyzed in a FLUENT ANSYS Based on the performance of parameters such as Pressure Drop Heat Transfer Coefficient, Baffle spacing and pitch angle we choose the best one in Baffles. In this work An model has been developed to evaluate analysis of a Helical and Segmental Baffle Heat Exchanger as well as the Comparative analysis between the thermal Parameters between the Segmental and helical angle has been showed. From the Numerical Experimentation Results it is confirmed that the Performance of a Tubular Heat Exchanger can be improved by Helical Baffles instead of Segmental Baffles. Use of Helical Baffles In Heat Exchanger Reduces Shell side Pressure drop,,pumping cost, weight, fouling etc as compare to Segmental Baffle for a new installation. The Ratio of Heat to increase cross flow area resulting in lesser mass flux through out the shell Transfer Coefficient to Pressure Drop as higher than that of Segmental Baffle. The Pressure Drop in Helical Baffle heat exchanger is appreciably lesser as Compared to Segmental Baffle heat exchanger. Helical Baffle is the much higher than the Segmental baffle because of Reduced By Pass Effect &Reduced shell side Fouling. The Helical Baffle is three times higher than the Segmental Baffle. Thundil Karuppa Raj et al [2], In this paper presents the study, attempts were made to investigate the impacts of various baffle inclination angles on fluid flow and the heat transfer characteristics of a shell-and-tube heat exchanger for three different baffle inclination angles namely 0, 10 and 20. The simulation results for various shell and tube heat exchangers, one with segmental baffles perpendicular to fluid flow and two with segmental baffles inclined to the direction of fluid flow are compared for their performance. The shell side design has been investigated numerically by modeling a small shell -and-tube heat exchanger. The study is concerned with a single shell and single side pass parallel flow heat exchanger. The flow and temperature fields inside the shell are studied using non-commercial CFD software tool ANSYS CFX 12.1. For a given baffle cut of 36 %, the heat exchanger performance is investigated by varying mass flow rate and baffle inclination angle. From the CFD simulation results, the shell side outlet temperature, pressure drop, recirculation near the baffles, optimal mass flow rate and the optimum baffle inclination angle for the given heat exchanger geometry are determined. @IJAERD-2015, All rights Reserved 553

Fig. 3 Variation of temperature with baffle inclination angle (for various mass flow rates) Fig.4 Variation of pressure drop with baffle inclination angle (for 0.5 kg/s, 1 kg/s, 2 kg/s mass flow rates) The shell side of a small shell-and-tube heat exchanger is modelled with sufficient detail to resolve the flow and temperature fields.the shell side of a small shell-and-tube heat exchanger is modelled with sufficient detail to resolve the flow and temperature fields.for the given geometry the mass flow rate must be below 2 kg/s, if it is increased beyond 2 kg/s the pressure drop increases rapidly with little variation in outlet temperature.the pressure drop is decreased by 4 %, for heat exchanger with 10 baffle inclination angle and by 16 %, for heat exchanger with 20 baff le inclination angle.the maximum baffle inclination angle can be 20, if the angle is beyond 20, the centre row of tubes are not supported. Hence the baffle cannot be used effectively. Hence it can be concluded shell and tube heat exchanger with 20 baffle inclination angle results in better performance compared to 10 and 0 inclination angles. Sunil S. Shinde, et al. [3],This paper presents The concept of helical baffle heat exchangers was developed for the first time in Czechoslovakia. The Helical baffle heat exchanger, also known as Helixchanger, is a superior shell-and-tube exchanger solution that removes many of the inherent deficiencies of conventional segmental-baffle exchangers. Helical baffle heat exchangers have shown very effective performance especially for the cases in which the heat transfer coefficient in shell side is controlled or less pressure drop and less fouling are expected. From the Numerical & experimental results it is confirmed that the performance of tubular heat exchanger can be improved by helical baffles instead of conventional segmental baffles. Use of helical baffles in heat exchanger reduces shell side pressure drop, pumping cost, size, weight, fouling etc. as compare to segmental baffle for new installations. The helix changer type heat exchangers can save capital cost as well as operating and maintenance cost and thus improves the reliability and availability of process plant in a cost effective way. For the helical baffle heat exchangers, the ratios of heat transfer coefficient to pressure drop are higher than those of a conventional segmental heat exchanger. This means that the heat exchangers with helical baffles will have a higher heat transfer coefficient when consuming the same pumping power. It can be concluded that proper baffle inclination angle will provide an optimal performance of heat exchangers Sandeep K. Patel, Professor Alkesh M. Mavani et al. [4],In this paper There is increase in pressure drop with increase in fluid flow rate in shell and tube heat exchanger which increases pumping power. Genetic algorithm provides significant improvement in the optimal designs compared to the traditional designs. Genetic algorithm application for determining the global minimum heat exchanger cost is significantly faster and has an advantage over other methods in obtaining multiple solutions of same quality. Thus, providing more flexibility to the designer. It also reveals that the harmony search algorithm can converge to optimum solution with higher accuracy in comparison with genetic algorithm. Tube pitch ratios, tube length, tube layout as well as baffle spacing ratio were found to be important design parameters which has a direct effect on pressure drop and causes a conflict between the effectiveness and total cost. In brief, it is necessary to evaluate optimal thermal design for shell and tube heat exchanger to run at minimal cost in industries. Nasir hayat et al.[5], present the research paper on CFD application in various heat exchanger designs. The main objective of this research paper is that CFD is employed for the following areas of study in various type of heat exchanger,fluid flow maldistribution, fouling and pressure drop and thermal analysis in the design and optimization phase.finally he concluded that conventional methods are used for the design and development of the heat exchangers are largely tedious and expensive in today s market.cfd has emerged as cost effective alternative and it provides speedy solution to heat exchanger design and optimization. Lin liu et al. [6],present the research paper on analysis on flow and heat transfer characteristics of EGR (exhaust gas @IJAERD-2015, All rights Reserved 554

recirculation) helical baffled cooler with spiral corrugated tubes.the main objective for this work is that exhaust gas recirculation which reduces the exhaust gas temperature for reduction of NOx. He used helical baffled tube cooler with spiral corrugated tubes. Finally he concluded that heat performance of spiral corrugated tube is significantly higher than that of s mooth tube. Gh.S. Jahanmir et al.[7],present the research paper on Twisted bundle heat exchanger performance evaluation by CFD.the main objective for the work is that shell and tube heat exchanger with single twisted tube bundle in five different twist ang les are studied using CFD and compared to conventional shell and tube heat exchanger with single segmental baffles. Heat transfer rate and pressure drop are the main issues investigated in this paper. Finally he concluded that angles of 55 and 65 are the optimum angles that provide the maximum heat transfer capacity at the constant and defined pressure drop. Results is that TTB heat exchanger has a much higher heat transfer coefficient per unit pressure drop compared to the single shell and tube heat exchanger at the same mass flow rate. Us man Ur rehman et al. [8], represent the paper on Heat Transfer Optimization of Shell-and-Tube Heat Exchanger through CFD Studies. The main objective for this paper is turbulence flow creates higher temperature difference between shell and tube therefore there is a need of modifications of current design to improve the heat transfer. Finally he concluded that model pred icts the heat transfer and pressure drop with an average error of 20% and thus the model can be improved. Lim Eng Aik et al. [9],Represent the paper on Computational Fluid Dynamics Analysis of Shell and-double Concentric-tube Heat Exchanger. the main objective of this paper is to decrase the length of the shell and tube heat exchanger because of that cost, manufacturing time and important factor is space can be reduced. finally he concluded that By using Kern method, the length of the shell-and-double concentric-tube heat exchanger needed to cool the hot water from 100 C to 80 C is Lsdct = 0.453 m. Whereas the the outlets of the heat exchanger are found to be at 80 C at the shell-side outlet, 30 C at the annulus outlet, and averaging at 80 C at the tube-side outlet. Arjun K.S. and Gopu K et al. [10],This paper presents the Outlet temperature of shell side was much affected while the baffle inclination angle was increased from 0 to 20. This was because of decrease in shell side pressure decline. The pressure decline was found to decrease by 4 per cent with 10 and 16 percent with 20 baffle inclination. The outlet velocity also increases with increase in baffle inclination and cause a further increase in heat transfer. The prediction of pressure decline and heat tra nsfer of the mode was found to be with an average error of 20 per cent. Rapid mixing and change in flow direction was observed in inlet and outlet region and found to be the only exception for the assumption in geometry and meshing. Reliable results was observed with the model by considering the standard k-e and wall function. It could also be seen that the mass flow rate when increased beyond 2kg/s; the pressure decline suddenly increases with practically nil variation in outlet temperature for the given geometry. The unsupported behavior of center row of tubes makes the baffle use ineffective when the baffle angle is above 20. He nce, the helix baffle inclination angle of 20 makes the best performance of shell and tube heat exchanger. III. CONCLUS ION The main objective of this paper From the Numerical Experimentation Results it is confirmed that the Performance of a Tubular Heat Exchanger can be improved by Helical Baffles instead of Segmental Baffles. Use of Helical Baffles In Heat Exchanger Reduces Shell side Pressure drop, pumping cost, weight, fouling etc as compare to Segmental Baffle for a new installation.the shell and tube heat exchanger with 20 baffle inclination angle results in better performance compared to 10 and 0 inclinat ion angles.there is increase in pressure drop with increase in fluid flow rate in shell and tube heat exchanger which increases pumping power. Tube length, tube layout as well as baffle spacing ratio were found to be important design parameters which ha s a direct effect on pressure drop and causes a conflict between the effectiveness and total cost. The unsupported behaviour of centre row of tubes makes the baffle use ineffective when the baffle angle is above 20. Hence, the helix baffle inclination angle of 20 makes the best performance of shell and tube heat exchanger. So Design and changes the some of these parameters (tube diameter, pitch length, mass flow rate etc.)to improve the capicity of heat exchenger and also improve the effectivness of heat exchenger. REFERENCES [1] P.S.Gowthaman. Analysis of Segmental and Helical Baffle in Shell and tube Heat Exchanger. International Journal of Current Engineering and Technology. @IJAERD-2015, All rights Reserved 555

[2] Thundil Karuppa Raj, Srikanth Ganne. Shell side numerical analysis of a shell and tube heat exchanger considering the effects of baffle inclination angle on fluid flow using CFD.journal of science direct. [3] Sunil S. Shinde, Samir S. Joshi, Dr. S. Pavithran. Performance Improvement in Single phase Tubular Heat Exchanger using continuous Helical Baffles.journal of International Journal of Engineering Research. [4] Sandeep K. Patel, Professor Alkesh M. Mavani. Shell & tube heat exchanger thermal design with optimization of mass flow rate and baffle spacing. Journal of International Journal of Advanced Engineering Research and Studies..[5] Muhammad Mahmood Aslam Bhutta, Nasir Hayat, Muhammad Hassan Bashir, Ahmer Rais Khan, Kanwar Naveed Ahmad, Sarfaraz Khan. CFD application in various heat exchanger designs.journal of science direct. [6] Lin liu. Analysis on flow and heat transfer characteristics of EGR helical baffled cooler with spiral corrugated tubes.journal of science direct. [7] Gh.S. Jahanmir, F. Farhadi. Twisted bundle heat exchanger performance evaluation by CFD.journal of science direct. [8] Us man Ur rehman. Heat Transfer Optimization of Shell-and-Tube Heat Exchanger through CFD Studies. journal of science direct. [9]Lim Eng Aik Computational Fluid Dynamics Analysis of Shell and-double Concentric-tube Heat Exchanger. journal of science direct. [10] Arjun K.S. and Gopu K.B. Design of Shell and Tube Heat Exchanger Using Computational Fluid Dynamics Tools.journal of Research Journal of Engineering Sciences. @IJAERD-2015, All rights Reserved 556