High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal for lubrication, dust blowing and cooling. Valve for coolant [Option] Pilot air operated cylinder driving mechanism. Metal seal with poppet valve structure. Port (P): Pilot SUP port Port 0(P2): Pilot EXH port Choice of two seal materials NR/FKM Port (P) (Pilot air Port Port Smooth valve operation Reduced valve switching resistance due to balance structure EXH port) Port EXH port) Port pplication Example Metal seal poppet valve construction Nozzle Tank Coolant pump Switching nozzles on supplying coolant liquid. Series Operating fluid pressure.5 MPa 7.0 MPa port valve (.5 MPa, 7.0 MPa) Ex. ) port valve: Reducing load to pump 2 port valve (7.0 MPa) Inlet side (supply side): port, Outlet Inlet side (supply side): port, Outlet side (exhaust side): port 2. Sup- side (exhaust side): port 2 and port. Nozzle Supply pilot air higher than 0.25 MPa ply pilot air higher than 0.25 MPa to Tank to port (P). Coolant port (P). pump Stop valve For reducing load to pump, coolant liquid is returned from port to tank each time. Ex. 2) port valve: Switching nozzle Port (P) (Pilot air Port Port Port 2 port (Large flow type) Port EXH port) Port size Rc /8(0), /2(5) /4(20), (25) /8(0), /2(5) /4(20), (25) Ex.) 2 port valve: Nozzle ON/OFF Tank Coolant pump Nozzle VN VN SGC SGH VNC VND VCC TQ 627
High Pressure Coolant Valve:.5 MPa, 7.0 MPa Series [Option] ir operated External pilot solenoid 2 Port port 2 port 2 port is 7.0 MPa only. Valve type 5 2 5 D N.C./.5 MPa N.C./7.0 MPa Seal material NR seals FKM seals How to Order Thread type Nil F N T Rc G NPT NPTF Option Nil Note) Silencer is provided as standard on pilot EXH port (P2). Nil Q None With bracket Electrical entry/with light/surge voltage suppressor D DIN terminal DIN terminal with light/surge voltage DZ suppressor Option Description racket (With bolt and washer) Valve size 2 4 0 5 20 25 Port size 8 4 Component part no. 2 4-6 2-6 -6 4-6 Rated voltage 00 VC / Hz 2 200 VC / Hz 0 VC / Hz 4 220 VC / Hz 5 24 VDC 6 VDC 7 240 VC / Hz Semi-standard For other rated voltages, please consult with SMC. How to Order Pilot Solenoid Valves VO07 5 Rated voltage 00 VC / Hz 2 200 VC / Hz 0 VC / Hz 4 220 VC / Hz 5 24 VDC 6 VDC 7 240 VC / Hz Semi-standard For other rated voltages, please consult with SMC. D Q Nil Q Light/surge voltage suppressor D DIN terminal DZ DIN terminal with light/surge voltage suppressor ccessory Function plate for VO07 (D sealing, with thread): DXT52-4-5 628
High Pressure Coolant Valve.5 MPa, 7.0 MPa Series Specifications Model Operating fluid pressure Fluid (Main piping) Operation Operating fluid temperature Pilot air Pressure Temperature Lubrication Proof pressure mbient temperature Max. operating frequency Mounting position Port size Orifice diameter (mm) Flow rate Kv characteristics Conversion Cv Pilot port size Weight (kg) Face-to-face dimension (mm) Equivalent size Note ) No freezing Note 2) This product cannot be used for water applications. port valve 2 port valve 2 4 2 4 2 4-0 -5-20 -25-0 -5-20 -25-0 -5-20 -25 0 to.5 MPa 0 to 7.0 MPa Coolant Note 2) External pilot solenoid/ir operated 5 to C Note ) / 5 to C Note ) (NR seal) 5 to C Note ) / 5 to 99 C Note ) (FKM seal) 0.25 to 0.7 MPa 5 to C Note ) Not required (Use turbine oil Class ISO VG2, if lubricated.) 5.5 MPa 0.5 MPa 5 to C Note ) 20 times/min Vertical upwards 8 4 8 4 8 4 ø7. ø8.7 ø0.6 ø4. ø.9 ø5.2 ø6.2 ø7. ø8 ø9.5 ø ø5.7.6..9 6.8 0.5.0.4 2..9 2.7 5.0 7.5.9.6 4.5 7.8 0.6.2.6 2.4 2.2. 5.8 8.7 8 4 8 4 8 4 2. 5.6 8.2 2. 5.6 8.2 2. 5.6 8.2 80 00 5 80 00 5 80 00 5.5 MPa Pilot Operated Solenoid Valve Specifications Pilot solenoid valve Electrical entry Coil rated voltage (V) C (/ Hz) DC llowable voltage fluctuation Temperature rise pparent power Power consumption Manual override C Inrush Holding DC Note) Refer to page 628 for how to order pilot solenoid valves. VO07- D DZ(-Q) DIN terminal 00 V, 200 V, Other voltage (Semi-standard) 24 V, Other voltage (Semi-standard) 5 to +0% of the rated voltage C or less (When rated voltage is applied.).7 V ( Hz), 0.7 V ( Hz) 7.6 V ( Hz), 5.4 V ( Hz) 4 W (without light), 4.2 W (with light) Non-locking push type 7.0 MPa Symbol Operation Valve type ir operated External pilot Solenoid Port VN VN SGC SGH VNC VND VCC TQ 629
Series Construction!2 (P): External pilot port u r!0 Port Valve element t o Valve element y i 0(P2) : Pilot EXH port!0 e e u r i!! t Port q o q w w Port Port valve 2 Port valve Working Principle When the pilot operated solenoid valve!2 is not energized, the valve element t connected to the piston u is closed by the return spring i. Then valve element y connected to the valve element t is open. When the pilot operated solenoid valve!2 is energized (or when pressurized air enters through the port (P) of the air operated type), the pilot air supplied to the bottom of the piston u moves upward to open the valve element t and closes the valve element y. Component Parts No. Description Material Note ody Cast iron Plated 2 4 Undercover Cover Plate Cast iron luminum alloy Iron Plated 5 Valve element 6 7 8 Valve element Piston Return spring luminum alloy Piano wire 9 Valve seat 0 Rod Parallel pin Pilot solenoid valve Refer to How to Order Pilot Solenoid Valves on page 628.
High Pressure Coolant Valve.5 MPa, 7.0 MPa Series Dimensions Pg9 Pilot SUP port (P) Pilot EXH port 0(P2) Silencer installed (Standard) EKX-L7004-040:, 2 N20-02:, 4 pplicable cable O.D. ø6 to ø8 Light/surge voltage suppressor (For DZ) Manual override (Non-locking push type) H I P P2 J E G Main port (ack side port 2) racket (Option mark: ) R S N 5 M U: Female thread for bracket mounting Same as back side 8 locations K L Q D C Main port ( port valve only) T: Long hole for mounting 4 positions F O P Dimensions Model Main port, 2, Pilot port 2 Port Port (P), 0(P2) -0 2 x 8 x 8 8 2-5 2 x x 8-20 2 x 4 x 4 4 4-25 2 x x 4 Note) ( ): product (-Q) Model -0 2-5 -20 4-25 J 20 24 24 K 29 6 48 5 L 25 0 5 8 M 0 40 56 80 00 5 N 7 4.5 58.5 Note) 27 (29) 246.5 (248.5) 282 (284) 0 (0) O 75 00 6 4 P 88 8 48 6 Q 6 44.4 57.7 66.4 C 77 96 D 46 76 85 R 0.5 6 9.5 5.5 Flow indicator for 2 port valve E 4 40 F 24 6 4 S T 62 6 x 8 70 7 x 0 92 9 x 09 9 x G 5 64.5 200 29 H 79 90 (mm) I 77 95.5 9 U M5 x 0.8 depth 5.5 M6 x depth 6 M8 x.25 depth 6 M8 x.25 depth 6 VN VN SGC SGH VNC VND VCC TQ 6
Series Specific Product Precautions e sure to read this before handling the products. Refer to back page for Safety Instructions and pages 7 to 9 for 2 Port Solenoid Valve for Fluid Control Precautions. Warning Design. Extended periods of continuous energization If a valve is continuously energized for long periods, heat generation of the coil may result in reduced performance and shorter service life. This may also have an adverse effect on the peripheral equipment in proximity. Should a valve be continuously energized for long periods, or its daily energized state exceeds its non energized state, please use a valve with DC specifications. dditionally, when using with C, energizing for long periods of time continously, select the air-operated valve and use the continuous duty type of the VT07 for a pilot valve. Warning Mounting. Do not apply external force to the coil section. When tightening is performed, apply a wrench or other tool to the outside of the piping connection parts. 2. Do not warm the coil assembly with a heat insulator, etc. Use tape, heaters, etc., for freeze prevention on the piping and body only. They can cause the coil to burn out.. void sources of vibration, or adjust the arm from the body to the minimum length so that resonance will not occur. 4. When mounted in the vertical downward direction, foreign matter can remain in the plate assembly part if there are foreign matters in the coolant. For this reason, avoid mounting in the vertical downward direction as much as possible. 5. Mount the series vertically top side up.. pplied voltage When electric power is connected to a solenoid valve, be careful to apply the proper voltage. Improper voltage may cause malfunction or coil damage. 2. Confirm the connections. fter completing the wiring, confirm that the connections are correct. Mounting Direction of Pilot Solenoid Valve Warning With external pilot solenoids, the pilot solenoid valves are not splash proof specifications, and so care must be taken not to get fluid on oneself such as when performing maintenance. Direction of mounting When replacing a valve, if an external pilot solenoid valve is mounted in the wrong direction, it may malfunction or leak air. External Pilot Pilot port piping (P) and 0 (P2) piping should be as follows according to the model. Port ir operated Solenoid (P) External pilot External pilot 0 (P2) leed port Pilot exhaust Fluid quality Please note that using fluids that contain foreign mterial (especially hard objects like glass chips), may cause damage to the valve, will reduce sealing performance, and may cause early failure. ack Pressure of Port Valve ( series). Ensure that back pressure of port from is less than 5 MPa. When high temperature fluids are used, use fittings and tubing with heat resistant features. (Self-align fittings, PTFE tubing, Copper tubing, etc.) 62