RESILIENT INFRASTRUCTURE June 1 4, 2016

Similar documents
Plastic Hinging Considerations for Single-Column Piers Supporting Highly Curved Ramp Bridges

Assessing Pavement Rolling Resistance by FWD Time History Evaluation

Approximately 11,200 mm c/c (field measurement) Two glulam slab girders mm x 1210 mm; 3100 mm clear distance between girders.

Appendix F-1 Description of the Long-Term Alternatives

EXPERIMENTAL STUDY ON EFFECTIVENESS OF SHEAR STRENGTHENING OF RC BEAMS WITH CFRP SHEETS

Parametric study on behaviour of box girder bridges using CSi Bridge

Analysis Methods for Skewed Structures. Analysis Types: Line girder model Crossframe Effects Ignored

Design principles and Assumptions

I-405 Sepulveda Pass Improvements Project

Live-Load Test and Finite-Model Analysis of an Integral Abutment Concrete Girder Bridge

LIVE-LOAD DISTRIBUTION FACTORS IN PRESTRESSED CONCRETE GIRDER BRIDGES

CFIRE December 2009

DRAFT Design Study Report February 2015 Eagle River Traffic Mitigation Phase 1 MOA Project No Appendix D Utilities

Load Testing, Evaluation, and Rating Four Railroad Flatcar Bridge Spans Over Trinity River Redding, California

Transverse Distribution Calculation and Analysis of Strengthened Yingjing Bridge

TRAFFIC IMPACT STUDY DERRY GREEN CORPORATE BUSINESS PARK MILTON SECONDARY PLAN MODIFICATION

Non-contact Deflection Measurement at High Speed

The Effect of Wheel Loading on a Railway Bridge: A Case Study on Minnamurra Railway Bridge

Post-Tensioned Concrete U-Girder Design. Midas Elite Speaker Series. Doug Midkiff, PE AECOM

Oscillator Experiment of Simple Girder Bridge coupled with Vehicle

BARRHAVEN FELLOWSHIP CRC 3058 JOCKVALE ROAD OTTAWA, ONTARIO TRANSPORTATION BRIEF. Prepared for:

2018 LOUISIANA TRANSPORTATION CONFERENCE. Mohsen Shahawy, PHD, PE

FREQUENTLY ASKED QUESTIONS

Construction Noise Memorandum

FREQUENTLY ASKED QUESTIONS

The FRACOF Composite Slab Test

Case Study of Bridge Load Rating in KY using BrR. C.Y. Yong, P.E., S.E., ENV-SP

LOADS BRIDGE LOADING AND RATING. Dead Load. Types of Loads

King County Metro. Columbia Street Transit Priority Improvements Alternative Analysis. Downtown Southend Transit Study. May 2014.

Replacing Through Girder Bridges Jones Road over Route 4

SKID RESISTANCE EVALUATION PROGRAM

Comparison of T-Beam Girder Bridge with Box Girder Bridge for Different Span Conditions.

Multideck 80-V2 Features and Applications

Clamping Force Effects on the Behaviour of Asymmetrical Friction Connections (AFC)

Implementation and Thickness Optimization of Perpetual Pavements in Ohio

PAPER FOR AREMA 2004 ANNUAL CONFERENCE LOS ANGELES UNION STATION RUN-THROUGH TRACKS. Paul Mak, PE, SE - DMJM HARRIS

Bridge Overhang Brackets

TRAFFIC PARKING ANALYSIS

Constructability Testing of Folded Plate Girders

Introduction and Background Study Purpose

Multideck 50-V2 Features and Applications

Western ND Meeting. February 19, 2014 Grant Levi, NDDOT Director

FIELD TESTING AND LOAD RATING REPORT: RIDOT#896 NORTH KINGSTOWN, RI

BEHAVIOUROF DISTORTION-INDUCEDFATIGUE CRACKSINBRIDGE GIRDERS

The INDOT Friction Testing Program: Calibration, Testing, Data Management, and Application

Vigaun bridge. Picture credits: Florian Schreiber Fotografie for SSF Ingenieure GmbH

MECHANICAL EQUIPMENT. Engineering. Theory & Practice. Vibration & Rubber Engineering Solutions

TABLE OF CONTENTS EXECUTIVE SUMMARY...1 INTRODUCTION...3 PROJECTED FUTURE GROWTH...3 ROADWAY IMPROVEMENT PROJECTS...4 POTENTIAL FUNDING SOURCES...

TRAFFIC IMPACT STUDY DERRY GREEN CORPORATE BUSINESS PARK MILTON SECONDARY PLAN MODIFICATION

101 st T.H.E. Conference February 24,2015

Confederation Line West Queensway Terrace North. May 27, 2017

Analysis of Box Girder Bridges Using Haunches

LIVE LOAD TESTING AND ANALYSIS OF THE SOUTHBOUND SPAN OF U.S. ROUTE 15 OVER INTERSTATE-66

TRAFFIC IMPACT STUDY. USD #497 Warehouse and Bus Site

EXPERIMENTAL AND NUMERICAL STUDIES OF THE SCISSORS-AVLB TYPE BRIDGE

Mississauga Bus Rapid Transit Preliminary Design Project

Table of Contents. Page EXECUTIVE SUMMARY Introduction 2

BRIDGEBY BURLEIGH LAW, P.E. Bringing Back the Big Four. An unused railroad truss bridge is reinvented as a new pedestrian gateway over the Ohio River.

Schedule 18 (Technical Requirements) DBFO Agreement EXECUTION VERSION APPENDIX B - SELECT DEPARTMENT STANDARD DRAWINGS AND REFERENCE TABLES

Click to edit Master text styles

Project Description: Georgia Department of Transportation Public Information Open House Handout PI#(s): , County: Muscogee

Heavy Truck Conflicts at Expressway On-Ramps Part 1

UT Lift 1.2. Users Guide. Developed at: The University of Texas at Austin. Funded by the Texas Department of Transportation Project (0-5574)

Abstract In this paper, we developed a lateral damper to improve the running safety of railway vehicles

Tests on Plate Girders Containing Web Openings and Inclined Stiffeners

BRE/TSLAB Vulcan Comparisons. Roger Plank Anthony Abu & Ian Burgess

DRAFT REPORT TXDOT SH 183 MASTER DRAINAGE STUDY HYDRAULIC ANALYSIS OF ELM FORK OF TRINITY RIVER CROSSING AT SH 183 WITHIN THE ELM FORK WATERSHED

Public Information Packet FY Fargo-Moorhead Metropolitan Transportation Improvement Program (TIP)

10. Predesign charts of castellated beams

Experimental and Analytical Study of a Retrofitted Pin and Hanger Bridge

EXCEPTION TO STANDARDS REPORT

Comparative Study on Super Structure of Box Girder Bridge and Cable Stayedbridge with Extra Dosed Bridge

Road User Cost Analysis

Reduction of vehicle noise at lower speeds due to a porous open-graded asphalt pavement

105 Toronto Street South, Markdale Transportation Impact Study. Paradigm Transportation Solutions Limited

CALIBRATION OF ALBERTA FATIGUE TRUCK

COST ANALYSIS FOR BRIDGE AND CULVERT. Essam A. Mostafa

Tongaat Hullette Developments - Cornubia Phase 2. Technical Note 02 - N2/M41 AIMSUN Micro-simulation Analysis

Foster Ave and Harlem Ave. RLR Crash Data and Analysis

LEVER OPTIMIZATION FOR TORQUE STANDARD MACHINES

Timber-Concrete Composite Floor

Innovative Overload Permitting in Manitoba Allowing a Kg (GVM) Superload

Multideck 60-V2. Contents

OHIO Department of Transportation Project # Franklin County, OH. ISSA Presidents Award Submission Strawser Construction Inc.

Hillsboro Canal Bridge Monitoring

Note: The October 2007 version of this report has been updated in this December 2008 report to present costs in year 2007 dollars.

EXPERIMENTAL AND FINITE ELEMENT ANALYSIS OF SKEW GIRDER BRIDGES RAVINDRA SWAROOP. Department of Applied Mechanics. Submitted

Investigation of Steel-Stringer Bridges: Superstructures and Substructures, Volume I

Traffic Management Plan and Queuing Analysis Lakehill Preparatory School Z Hillside Drive, Dallas, TX October 27, 2015

2 MAJOR MACKENZIE DRIVE WEST JOG ELIMINATION AT HUNTINGTON ROAD CITY OF VAUGHAN

November 1, Mr. Jafar Tabrizi President, Tabrizi Rugs 180 Bedford Highway. Traffic Impact Statement BH-1 and BH-2, Southgate Drive, Bedford, NS

Aerodynamic Investigation of Cable-stayed Bridge with 2-edge Girder

Feasibility of Ultra Long-Span Suspension Bridges Made of All Plastics

AN EXPERIMENTAL STUDY OF THE AERODYNAMICS FORCES ACTING ON A TRUCK

Comparison of Live Load Effects for the Design of Bridges

Study Area and Location District PSA Ward ANC Phase Description C Planned Suitland Parkway Westbound at Stanton Road Southeast

MEMORANDUM. Figure 1. Roundabout Interchange under Alternative D

SPE MS. Abstract

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA)

A COMPARATIVE STUDY OF LIVE LOADS FOR THE DESIGN OF HIGHWAY BRIDGES IN PAKISTAN

Transcription:

RESILIENT INFRASTRUTURE June 1 4, 2016 RE-TESTING OF A FIRE-DAMAGED RIDGE Alexander M.. Au, Senior ridge Engineer, Highway Standards ranch, Ontario Ministry of Transportation, anada ASTRAT A proof load test was performed on a fire-damaged bridge in October 2008 and its load capacity was confirmed. The bridge was then re-opened for full traffic shortly after the load test. It was further repaired in 2009 which included concrete patching and carbon fibre reinforced polymer (FRP) warping of 6 girders in the main span. The bridge is located at one of the busiest highways of the country with many heavy trucks passing daily. Also, reinforced concrete could deteriorate much faster than usual after the fire accident. In 2014, the ridge Office was requested to re-test the bridge in order to re-confirm its performance. The re-testing of the bridge was carried out in November 2014, 6 years after the first load test. The objective of this test was to re-confirm the bridge performance. Therefore, strain gauges and linear voltage displacement transducers (LVDT) were installed on the bridge at the locations almost identical to that installed in 2008 s load test. The applied loads were also similar to that from the original load test. This second load test was successfully completed and the load effects from both load tests were compared. It was observed that the bridge performances in 2008 and 2014 were similar. Therefore, the conclusions from the 2008 load test are still applicable. Keywords: load test, fire-damaged bridge. 1. INTRODUTION Highway 401 westbound ridge #7 over Highway 401 Ramp to Highway 404 northbound/don Valley Parkway southbound (see Figure 1(a)) is a three-span (23.2m-29.5m-23.2m) semi-continuous slab-on-girder bridge (continuous for live load). Figure 1(b) shows a picture of the bridge. The bridge deck consists originally a 175 mm thick concrete deck slab, cast compositely on top of 9 rows of 1350 mm depth PI girders. A 40 mm thick concrete overlay was added to the deck in 1981, which has an exposed concrete riding surface. The superstructure is supported on abutments and two multi-column pier systems. The bridge, more than 60 degree skew, has a roadway width of 16.5 m, which carries three lanes of Highway 401 W ollector traffic over the ramp from Hwy 401 Express to Highway 404 Northbound and Don Valley Parkway Southbound. The highway ramp below provides two lanes of traffic. ridge Site Figure 1(a): ridge Site at Highway 401 and Highway 404 Figure 1(b): South Elevation of the ridge STR-808-1

Figure 2: Girders with FRP Wraps Figure 3: ridge onditions The bridge structure was damaged by a fire created by a truck accident in the early morning of September 4, 2008. The damage was severe and was confined to the south-west portion of the main span. Two repair works were applied to the bridge separately in 2008 and in 2009. The first repair work was an emergency deck soffit repair and massive transverse diaphragms were constructed between girders. After the first repair in September, a load test (Au, Lam and Tharmabala 2010) was carried out in October 2008. It was concluded that the bridge was able to carry the anadian Highway ridge Design ode (HD) design load. The bridge was then re-opened for full traffic shortly after the load test. The first repair did not cover minor damages. The second repair in 2009 included concrete patching and FRP wrapping of 6 girders in the main span. The effect of the FRP on the bridge stiffness and its behaviour would be small, and it would be expected to become significant at higher loads approaching bridge s ultimate capacity (erullo et. al. 2013). Figure 2 shows the girders with the FRP wrapping. ehaviour load test was performed on 23 November 2014 to re-assure the bridge s performance. The bridge was inspected before the load test (see Figure 3). It was found that the girders were in a reasonable good condition (see Figures 1 (b) to 3). 2. APPLIED LOADS Two test trucks loaded incrementally with concrete blocks to a maximum total gross vehicle weight of 650 kn and 668 kn respectively were moved together across the structure in 15 pre-determined steps. Three load levels were considered (i.e. 24, 36 and 48 concrete blocks per test truck). Each concrete block is about 1 tonne. The test trucks were moved along load line 5 that maximized the load effects on girder #3 (from south). Figure 4 indicates the transverse locations of the test trucks and Figure 5 shows the 15 load steps. 9 out of 15 steps were identical to that applied in the 2008 load test. 6 more steps were considered in the second test in order to generate a broader range of behaviour. The maximum load will generate about 65% of the load effect caused by HD (SA 2006) design live load and 118% of the HD (SA 2006) SLS load. ecause the bridge is carrying Highway 401 westbound collector traffic and there is a hospital nearby, it was decided not to close the bridge completely and to leave one lane opened during the load test. Although leaving one lane opened during bridge test is unusual, the following mitigations were used to minimize the influence of the data for girder 3: i) the test was performed in the early hours STR-808-2

on Sunday morning when the traffic volume was low; ii) only lane 3 was opened to keep live load traffic away from girder 3; and iii) test data were recorded when there was no other commercial truck on the bridge. Test Trucks (move from East to West) NORTH Line 5 Volvo 600 600 Western SOUTH 18288 4572 914 10364 6096 914 Shoulder Lane 3 Lane 2 Lane 1 Shoulder G9 G8 G7 G6 G5 G4 G3 G2 G1 All dimensions in mm Figure 4: Load Line 5 on the ridge N West ound Traffic WEST AUT. EARINGS WEST L PIER EAST PIER L5 Volvo EAST AUT. EARINGS L5 Western 32305 29 29 27 27 3048 3658 3658 3658 2438 16460 8230 3658 12350 4572 entre of ridge / Girder 5 All dimensions in mm 29695 23165 29454 23165 75784 110 m 100 m 90 m 80 m 70 m 60 m 50 m 40 m 30 m 20 m 10 m 0 m 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 13 Volvo Steps (5 m behind) 2 m apart 1 m apart 2 m apart Test Trucks with 24, 36, 48 locks Figure 5: 15 Step Locations for the Test Trucks STR-808-3

3. INSTRUMENTATION From the experience of the load test in 2008, 8 locations on two sections and from girders 2 to 5 were monitored. There were 3 strain gauges and 1 LVDT on each location. A total of 32 gauges were installed. Figures 6 and 7 indicate the instrumentation locations. Figure 7 shows the channel numbers identifying 8 LVDTs and 24 strain gauges. Figure 8 shows typical LVDT and strain gauges. LVDTs were installed directly on the concrete surface to avoid the FRP sheet. All strain gauges were installed directly on the top of the FRP sheet. It was assumed a perfect bonding between strain gauges and FRP warps (see erullo et. al. 2013). The instrumentation was carried out in the early hours on two separated Sunday mornings (November 9 and 16, 2014). Due to the repair of the girders and the installation of FRP wraps, it was difficult to install the gauges exactly at the same locations as in the load test of 2008. Therefore, the gauge locations in this test were installed as close as possible to that installed in the 2008 load test. The performance of the strain gauges was a concern because instrumentation was carried out in November under wet conditions and near zero temperature. On the test day, one of the LVDTs and some strain gauges were found to be malfunctioned. In order not to further delay the test, these gauges were not fixed and were ignored. WEST West ound Traffic EAST 75784 AUT. RGS G9 G8 G7 G6 PIER RGS. G5 G4 G3 G2 G1 PIER RGS. AUT. RGS. Instrumentation Locations 23165 29454 23165 All dimensions in mm Section West of Middle of Main Span : 4 LVDTs, 12 Strain Gauges Section etween Section and West Pier : 4 LVDTs, 12 Strain Gauges Figure 6: 8 Instrumentation Locations STR-808-4

21 22 #28 Girder 2 Girder 3 9 10 23 11 #18 #30 #29 24 25 #20 12 13 26 14 5 1 #4 #11 6 #5 2 27 28 Girder 4 Girder 5 15 16 29 17 30 31 18 19 32 20 7 3 8 4 Figure 7: Strain Gauge and LVDT Locations at Sections and of Girders 2 to 5 Figure 8: Typical LVDT on oncrete and Typical Strain Gauges on FRP STR-808-5

4. RESULTS ased on the theoretical analysis and results from the load test in 2008, Girder 3 was known to experience the maximum response due to test trucks positioned transversely at load line 5 as shown in Figure 4. The second load test was carried out on November 23, 2014. The load test in 2008 was carried out in early October. The average temperatures at the site were different for both tests. However, the data obtained was processed after the test so that temperature effects were eliminated. Therefore, the resulting data were mainly due to live loads. For both tests, identical live loads were applied and so, the results from both tests were directly comparable. In Figures 9 and 10, the deflections of Girder 3 measured at sections and were found to be similar to that recorded from 2008 test and also behaved linearly. Figure 11 shows the transverse distribution of the deflections at section. It indicates that the deflection distribution compared very well with the result from the 2008 load test. Load line 5 produced the highest deflection on Girder 3. The transverse deflection distribution is a reflection of the transverse load distribution of the bridge. Therefore, the lateral load distribution of the bridge is similar to that from the 2008 load test. The largest strain was observed at strain gauge 14 (Girder 3 and Section ). Figure 12 shows a comparison of the strain measured from 2008 and from this load test. The current measurement was smaller than the strain measured in 2008, and the distributions over different load steps were similar with respect to the test truck locations. However, the comparison of strain measurement was not as good as the deflection measurement. This discrepancy was mainly due to the slightly different locations of the strain gauges in both load tests. Such discrepancy could be reproduced from a theoretical analysis. The linear relationship of the strain with respect to the applied load was confirmed in Figures 13 (a) and (b) for Sections and respectively. oth figures show a lower rate of increase in strain with loads and the strain was linear up to 48 concrete blocks per test truck. Figure 14 shows the vertical strain distributions at Section of Girder 3. It was based on the strain gauges located at mid-web, lower web and girder soffit, under three different load levels at 24, 36 and 48 blocks per truck. The location of the neutral axis matches the one obtained from the theoretical analysis. It means that the bridge composite action remains unaffected. Figure 9: Deflections of Girder 3 at Section due to Two 48 locks Test Trucks STR-808-6

(a) Girder 3 Section (b) Girder 3 Section Figure 10: Maximum Deflections of Girder 3 due to Two Test Trucks with Different Load Levels STR-808-7

Figure 11: Transverse Deflection Distribution of Different Girders at Maximum Load Level Figure 12: omparison of Strains at Girder 3 at 48 locks per Test Truck STR-808-8

(a) Girder 3 Section (b) Girder 3 Section Figure 13: Strains Measured at Soffits of Girder 3 at Sections and due to Different Load Levels STR-808-9

Figure 14: Strain Measured at Section of Girder 3 (hannels 24, 25 and 26) 5. ONLUSIONS The following conclusions could be drawn from the re-testing of this bridge. The vertical deflections were similar to that measured in the 2008 load test and were linear with increasing applied loads. The measured strains were comparable to that measured in 2008 and the measured strains were also linear with the applied load. Similar to the result in the 2008 load test, the measured deflections and the measured strains were smaller than the corresponding values given by the theory. From the transverse distribution of the deflections, the bridge is capable to distribute load transversely similar to that in the 2008 load test. omposite action remains unaffected possibly due to the attribution of the repair. ased on the above observations, the bridge is performing in a similar manner showed in the 2008 load test. Therefore, the conclusions from the 2008 load test are still applicable and the bridge should be capable of carrying the HD design load. REFERENES Au, A., Lam,. and Tharmabala,. 2010, Evaluating the Strength of a Fire-Damaged ridge by Load Testing, 8 th International onference on Short and Medium Span ridges, anadian Society for ivil Engineering, Niagara Falls, Ontario, anada, Paper 176, 1-11. erullo, D., Sennah, K., Azimi, H., Lam,., Fam, A. and Tharmabala,. 2013, Experimental Study on Full-scale Pretensioned ridge Girder Damaged by Vehicle Impact and Repaired with Fiber-Reinforced Polymer Technology, Journal of omposite for onstruction, ASE, 17(5), 662-672. SA, anadian Highway ridge Design ode, AN/SA-S6-06, SA International, Toronto, Ontario, anada, 2006. STR-808-10