Emergency Light Fitting for Fluorescent Lamps Series 6009

Similar documents
Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002

Emergency Luminaire with LED Series EXLUX 6409/1

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6402/2

LED Linear Luminaire Series EXLUX 6402

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Sheet-Steel Light Fittings Series 6114/1

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

7 Lighting Technology

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Sheet Steel Emergency Light Fitting Series 6018

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Floodlight LED Series 6125

Sheet-Steel Light Fittings Series 6014 / 6414

Linear Luminaire for Fluorescent Lamps

Floodlight LED Series 6525

Floodlight LED Series 6525

7 Lighting Technology

Compact Sheet-Steel Light Fittings Series 6114

7 Lighting Technology

Floodlight Series 6521/4

Floodlight Series 6121

Linear Luminaire with LED

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Load disconnect switch Series 8146/5-V11

Plug and Socket Devices SolConeX 16 A Series 8570

Terminal Boxes Series 8125

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

7 Lighting Technology

Ex UPS standard Series 8265

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Control switch/load disconnect switch Series 8008

Position Switches Series 8074/2

Position Switches Series 8060/2

Control Buttons / Switches for Panel Mounting Series 8003

Linear fluorescent luminaire LED V-CG-S

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Position Switches Series 8070/2

Tubular Light Fitting with LED Series 6036

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

7 Lighting Technology

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Terminal Boxes Series 8125

Load and Motor Switches, Load-Break Switches Series 8549

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Tank Inspection Lights Series 6122

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

Control Buttons Series 8082

Load and Motor Switches, Load-Break Switches Series 8544

Battery Boxes Series 8316

Operating Instructions

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Load and Motor Switches, Load-Break Switches Series 8544

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

EXEL-L. Detail of the internal side. Transparent polycarbonate

Safety Switches Series 8537

Control Device System NEC Series ConSig 8040

Operating Instructions

FHL. Ex d. Body in aluminium

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

Pendant Light Fitting IEC

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

Linear fittings EVDL LED fitting - zones 21, & 22

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

EX-REPAIR AND MAINTENANCE RECEPTACLES

Operating Instructions

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

8150 Series Terminal Boxes

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

10 Load and Motor Switchgear

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Portable Lamps Series HS6145, HSL145

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

Terminal Boxes Series 8252/1

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

K: bracket type. L: pole type

Transcription:

> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or battery enclosure > Weekly functional test > Light duration test of the emergency lighting once a year www.stahl.de The lights of the Series EXLUX 6009 can be used as emergency lighting ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x 16126E00 WebCode 6009A Lighting /1

Selection Table Version Lamps Battery Lighting hours Order number Weight W Standard light fitting 2 x 18 7 Ah 1.5 / 3 h (emergency light) 6009/522-9617-1611-7 7.600 2 x 36 7 Ah 1.5 / 3 h (emergency light) 6009/542-9617-1611-7 9.650 Order Number Supplement Through wiring without 6.09/...-.0..-...-. with 6 conductors 6.09/...-.6..-...-. ECG 220... 240 V 6.09/...-...7-...-. 110... 127 V 6.09/...-...6-...-. Connection terminal Cage clamp terminal type WAGO 0.5... 4 mm 2 6.09/...-...-1...-. Screw-type terminal type STAHL 1.5... 6 mm 2 6.09/...-...-2...-. Cable glands Standard 2 x M25 x 1.5 cable gland and 6.09/...-...-..1.-. 1 x M25 x 1.5 stopping plugs kg Special 2 x M20 x 1,5 cable gland and 1 x M20 x 1,5 stopping plug 6.09/...-...-..2.-. Emergency duration test with 6.09/...-...-...-7 without 6.09/...-...-...-8 Note The lights are delivered without fluorescent lamps and assembly parts. These parts must be ordered separately! Explosion Protection Global (IECEx) Gas and dust Europe (ATEX) Gas and dust Certifications and certificates Certificates Technical Data Electrical data Rated voltage Rated insulation voltage Disconnection of the light Ex d e mb IIC T4 Gb or Ex db eb mb IIC T4 Ex tb IIIC T80 C Db or Ex tb IIIC T80 C E II 2 G Ex d e mb IIC T4 Gb or Ex db eb mb IIC T4 E II 2 D Ex tb IIIC T80 C Db or Ex tb IIIC T80 C IECEx, ATEX Standard: 220... 240 V ± 10%, 50 / 60 Hz (Lamps acc. IEC60081) Optional: 110... 127 V ± 10%, 50 / 60 Hz (Lamps acc. IEC60081) 120V ± 10%, 50 / 60 Hz (Lamps acc. ANSI IEC C78.81)) 320 V When opening the light Switch with safety lock; when opening the central lock, all poles of the voltage supply to the ballast are disconnected; contacts of the switching element are NC contacts, they can only switched on again when the lamp cover and the central locking system are closed. In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply. /2 Lighting

Technical Data Luminous characteristics Lamps Measures for light guidance Ambient conditions Ambient temperature 2x 18 W; 2x 36 W (acc. to IEC60081) 2x 17W; 2x 32W (acc. to ANSI IEC C78.81) Standard: wide beam, internal reflector of the light fittings is painted in white colour. Colour: signal white RAL 9003; lateral glare reduction in the luminaire trough. - 30... + 50 C - 20... + 50 C with Breathing Glands 8162-5... + 40 C operationable Mechanical data Degree of protection IP66 / IP67 (IP64 when using the breather 8162) IEC 60598 Protection class I (with internal PE connection) Material Enclosure Enclosure Polyester resin, glass fibre-reinforced Colour colour grey, similar to RAL 7035 Lamp cover Polycarbonate Gasket Silicone foam gasket in the lamp cover Lamp locking Central locking which can be opened/closed using a socket key M8 / wrench size 13, hinged lamp cover Mounting / Installation Cable glands Standard luminaire Plastic: 2 x M25 x 1.5 cable gland 8161 and 1 x M25 x 1.5 stopping plugs 8290 (enclosed) Metal: 2 x metal plates M20 x 1.5 connected by means of PE for metal cable entries Attention: cable entries must be ordered separately Special: max. 4 bores for M20, M25, NPT ½ max. 2 bores for NPT ¾ Connection Standard: Special: Metal cable glands: M20 x 1.5, M25 x 1.5; earthing of the metal cable entries by means of metal plates Spring clamp terminals 6-pole: L1, L2, L3, L', N, PE Clamping range: 1 x 0.75... 4 mm 2 (solid / finely stranded) (2 free clamping units per pole available) Terminal block with covering 6-pole: L1, L2, L3, L', N, PE Clamping range: 2 x 1.5... 6 mm 2 (solid); 2 x 1.5... 4 mm 2 (finely and extra finely stranded) Through wiring Through wiring Standard luminaire Luminaires are equipped with internal through wiring. Ingoing and outgoing leads can be connected on the opposite sides. Terminals: see Techn. data Wiring cross-section: 2.5 mm 2 for max. 16 A without Optional On the connection side, there are 2 bores M25 x 1.5 for cable entries for ingoing and outgoing wiring of the connection line (ingoing and outgoing leads on one side). Assembly For outdoor mounting, a breather is recommended Standard luminaire Standard: 2 x M8 insert nuts in the enclosure Special: Mounting grooves in the enclosure for the use of fastening and ceiling rails for variable luminaire mounting (variable mounting distances for luminaires 17 W; 18 W: 320... 480 mm; 32 W; 36 W: 670... 930 mm) Lighting /3

Technical Data Emergency light electronics Emergency light mode Emergency light service time In the emergency light mode, only one lamp is used, which results in reduced light output Battery capacity Emergency light Emergency lighting power service time 17 W; 18 W 32 W; 36 W 7 Ah 1.5 h 100 % 60 % 3.0 h 60 % 30 % Switchover voltage Battery set Version Operating voltage Capacity Replacing the battery set from mains to battery operation for U < 0.74 x U N from battery to mains operation for U > 0.80 x U N Gas-tight NiCd battery 6 V 7 Ah When opening the battery enclosure, the connection between the battery set and the emergency light electronics is disconnected. The battery set can be replaced after disconnecting the plug-in contacts. Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Fluorescent lamps 18 W 1350 Im 108952 0.100 04936E00 36 W 3350 Im 108951 0.200 Zweistiftsockel d 26 mm Lichtfarbe: Universal-weiß Stifte aus Messing Bracket for wall mounting with tube for side entry lamp; with tube, length 400 mm, d 42 mm 108947 2.480 05460E00 Lamp cover for luminaire L=700 222427 0.639 for luminaire L=1310 222428 1.149 Lamp-holder Lamp holder G13 1 piece 117252 0.025 05696E00 Switch Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.025 10809E00 Socket key M8 / wrench size 13; to open/close the central locking 222430 0.210 15507E00 Adapter plates 1 x M20 x 1.5 1 piece 1 x M25 x 1.5 1 piece 115815 0.070 115818 0.070 05755E00 2 x M20 x 1.5 1 piece 115826 0.060 2 x M25 x 1.5 1 piece for use together with metal cable glands; the metal cable glands are integrated in the earthing system via adapter plates 115828 0.060 /4 Lighting

Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Mounting rail for a variable mounting distance 1 pair 222826 0.300 Mounting bracket 15584E00 Mounting clamp mounted on a mounting rail for a variable mounting distance; 1 pair 222456 0.400 Pipe clamp 15585E00 R 1 1 / 2 222459 1.200 R 1 1 / 4 222458 1.250 R 2 222460 1.300 15583E00 with mounting rail for a variable mounting distance; Material: stainless steel 1 pair Ring bolt M8, direct mounting in insert nuts, 1 pair 115736 0.120 Breathing gland 05378E00 M25 x 1.5 in order to avoid condensate formation 115738 0.020 05703E00 Ceiling and wallmounting bracket 15586E00 1 pair 222827 2.400 mounted on a mounting rail for a variable mounting distance; Material: stainless steel Lamp can be swiveled in steps of 15 Battery set for 6009 Battery cover with built-in battery. Gas-tight NiCd battery; 7 Ah / 6 V 223532 1.195 16332E00 Lighting /5

Dimensional Drawings (All Dimensions in mm [inch]) - Subject to Modifications 183,5 [7,22] M25 x 1,5 [ M25 x 0,06] L1 L2 L3 M25 x 1,5 [ M25 x 0,06] 125 [4,92] Dimensions EXLUX 6009 Luminaire 17/18 W 32/36 W L1 857 [33.74] 1467 [57.76] L2 1) 400 [15.75] 800 [31.50] L3 2) 320... 480 [12.60... 18.90] 1) fixed mounting distance 2) variable mounting distance 670... 930 [26.38... 36.61] 16127E00 Dimensional drawings for assembly parts and accessories (all dimensions in mm) - Subject to alterations 30,50 [ 1, 20 ] 12 [ 0, 47 ] 215 [ 8.46] 18,50 [ 0, 73 ] 30 [1,18]. 9 [0,35] 193-198 [7,60-7,80] 124 [ 4, 88] 11 [ 0, 43] 86 [ 3, 39] 74 [ 2, 91] 32 [1,26] 6,10 [0,24] ø 6,10 ø 8,10 9 [ø. 0, 24] [ø 0,32] [0,35] 13 [0,51] 215 [ 8, 46] 193-198 [7,60. - 7,80]. 143 [5,63] 15778E00 15779E00 Mounting rail ø 20 [ø 0,79] 24 [0,95] ø 42 [ø 1 1/4] ø 48 [ø 1 1/2] ø 60 [ø 2] 162 [6,38] 172 [6,77] 180,50 [1 1/4] 187,50 [1 1/2] 200,50 [2] 15782E00 15781E00 15783E00 Ring bolt fitted in insert nut of the light fitting Mounting bracket fitted in mounting rail Pipe clamp fitted in mounting rail /6 Lighting

Dimensional drawings for assembly parts and accessories (all dimensions in mm) - Subject to alterations 10x15 A 296 [11,65] 42 [ 1,65] ø 10,50 [ ø 0,41] 15 400 [15,75] A [1,39] 34 65,50-74,50 [2,58-2,93] 110 [4,33] 8,50 [0,35] 8,50 [0,35] 198 [7,80] 160 [6,30] 120 [4,72] 143 [5,63] 104 [4,09] 90 130 [5,12] 220 [8,66] SW 5 20 [0,79] 180 [7,09] Wall mounting bracket fitted in mounting rail 15780E00 Bracket for wall mounting with pipe section 03257E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Lighting /7