Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Similar documents
Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

7 Lighting Technology

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Emergency Light Fitting for Fluorescent Lamps Series 6009

Sheet-Steel Light Fittings Series 6014 / 6414

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

LED Linear Luminaire Series EXLUX 6402

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Linear luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Linear Luminaire with LED Series EXLUX 6402/2

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Compact Sheet-Steel Light Fittings Series 6114

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Emergency Luminaire with LED Series EXLUX 6409/1

Terminal Boxes Series 8125

Plug and Socket Devices SolConeX 16 A Series 8570

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Compact Sheet-Steel Light Fittings Series 6114/1

Terminal Boxes Series 8125

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Sheet Steel Emergency Light Fitting Series 6018

7 Lighting Technology

Compact Sheet-steel Emergency Light Fitting Series 6118/1

7 Lighting Technology

Floodlight LED Series 6525

Linear Luminaire for Fluorescent Lamps

Floodlight LED Series 6125

Safety Switches Series 8537

Floodlight Series 6521/4

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Tank Inspection Lights Series 6122

Floodlight LED Series 6525

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Load disconnect switch Series 8146/5-V11

Control Buttons Series 8082

Floodlight Series 6121

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Operating Instructions

Control Buttons / Switches for Panel Mounting Series 8003

Ex UPS standard Series 8265

Position Switches Series 8070/2

Position Switches Series 8060/2

Control switch/load disconnect switch Series 8008

Load and Motor Switches, Load-Break Switches Series 8549

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

7 Lighting Technology

10 Load and Motor Switchgear

7 Lighting Technology

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Metal Position Switch Series 8074

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Linear Luminaire with LED

Load and Motor Switches, Load-Break Switches Series 8544

Position Switches Series 8074/2

Load and Motor Switches, Load-Break Switches Series 8544

Operating Instructions

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

Pendant Light Fitting IEC

Control Device System NEC Series ConSig 8040

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

Tubular Light Fitting with LED Series 6036

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

EX-REPAIR AND MAINTENANCE RECEPTACLES

Battery Boxes Series 8316

Terminal Boxes Series 8146

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

11 Control Panels, Distribution Panels and Components

K: bracket type. L: pole type

Portable Lamps Series HS6145, HSL145

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

I Ex-safety switches I

9 Control Equipment. Control Unit System Series ConSig 8040

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

I Ex-Safety switches I

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

8150 Series Terminal Boxes

Linear fluorescent luminaire LED V-CG-S

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

EX-RECESSED CEILING LIGHT FITTINGS

I Ex-safety switches I

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Transcription:

> As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life switch 1 and 2 (only 6000) www.stahl.de 00280E00 The lights of the Series EXLUX 6000 and EXLUX 6400 can be used for normal lighting but also for an emergency light which is supplied with current via a group or a central system. ATEX / IECEx / GOST NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 EXLUX 6000 EXLUX 6400 *) ATEX x x x x EXLUX 6000 x *) x *) x *) EXLUX 6400 x x EXLUX 6000 x EXLUX 6400 x x x x x x x x x x WebCode 6000A Lighting /1

Selection Table Version Lamp wattage Number of lamps Electronic ballast Order number Weight W kg Light Fittings for Fluorescent 18 1 1 channel EB 6000/521-8..1-013. 4.500 Lamps (Zone 1) Series 6000 2 2 channel EB 6000/522-9..1-013. 6.800 36 1 1 channel EB 6000/541-8..1-013. 7.300 2 2 channel EB 6000/542-9..1-013. 9.100 01968E00 58 1 1 channel EB 6000/561-8..1-013. 10.200 2 2 channel EB 6000/562-9..1-013. 10.800 Side entry lamp (Zone 1) Series 6000 18 1 2 1 channel EB 2 channel EB 6000/821-8081-0130 6000/822-9081-6130 6.200 8.000 36 1 1 channel EB 6000/841-8081-0130 9.600 2 2 channel EB 6000/842-9081-0130 9.600 01962E00 Light Fittings for Fluorescent Lamps (Zones 2, 21, 22) Series 6400 01968E00 Side entry lamp (Zones 2, 21, 22) Series 6400 18 1 1 channel EB 6400/521-8..0-213. 4.100 2 2x 1 channel EB 6400/522-9..0-213. 4.200 36 1 1 channel EB 6400/541-8..0-213. 6.900 2 2x 1 channel EB 6400/542-9..0-213. 7.000 58 1 1 channel EB 6400/561-8..0-213. 8.700 2 2x 1 channel EB 6400/562-9..0-213. 8.800 18 2 2 channel EB 6400/822-9080-6130 6.300 36 2 1 channel EB 6400/841-8080-0130 9.100 01962E00 Order Number Supplement Through wiring without 6000/...-.0..-... with 3 conductors 6000/...-.3..-... with 5 conductors 6000/...-.5..-... Cable glands Standard 1 x M25 x 1.5 cable gland and 6000/...-..1.-... 2 x M25 x 1.5 stopping plugs Special Specify non-standard gland parts 6000/...-..9.-... Monitoring module without 6000/...-...-...0 6.900 EB with extended voltage range 6048/131-02 address component (STAHL) 6000/...-...-...2 9.000 for 110... 240 V (only 18 and 36 W) 6000/...-...-4... for 120... 277 V (17, 32 and 40 W NEC standard) 6000/...-...-8... Note The lights are delivered without fluorescent lamps and assembly parts. These parts must be ordered separately! /2 Lighting

Explosion Protection Global (IECEx) Gas and dust IECEx PTB 05.0018 Ex d e IIC T4 Ex td A21 IP65 T80 C / T90 C Europe (ATEX) Gas PTB 97 ATEX 2031 SNCH 03 ATEX 3517 E II 2 G Ex d e IIC T4 E II 3 G EEx na II T6 (T4 bei Ta = 55 C) at 18 W E II 3 G EEx na II T4 bei 36 und 58 W Dust PTB 97 ATEX 2031 Zone 21: SNCH 03 ATEX 3516 Zone 22: SNCH 03 ATEX 3517 E II 2 D Ex td A21 IP 65 T80 C / T90 C E II 2 D IP66 T80 C ** T95 C at T a ( 55 C Certificates and approvals Certificates IECEx, ATEX, Brazil (UL do Brasil), India ATEX, Canada (CSA), USA (FM) (PESO), Canada (CSA), Kazakhstan (GOST-K), Russia (GOST-R), Ukraine (GOST-U), USA (FM), Belarus (GOST-B), Serbia (IZP), Corea KGS), China (CQST) Other approvals ship approval (GL) Further parameters Marking (CE) C 0158 C 0158 Technical Data Electrical data Rated voltage Electronic ballast AC: 220 (- 10%)... 240 (+ 10%) V, 50 / 60 Hz DC: 198... 254 V/ 1 lamp: 176... 264 V EB with extended voltage range Nominal operational current Power factor cos p Disconnection of the light End of life switch 6000/...-...-4... (18 and 36 W lamps) AC: 110 (- 10%)... 240 (+ 10%) V, 50 / 60 Hz DC: 104... 264 V 6000/...-...-8... (17, 32 and 40 W NEC lamps) AC: 120 (- 10%)... 277 (+ 10%) V, 50 / 60 Hz DC: 113... 294 V for lights of the versions IEC 60081 18 W 36 W 58 W with 1 lamps with 2 lamps with 1 lamps with 2 lamps 0.08 A 0.17 A 0.16 A 0.32 A 0.25 A 0.50 A ANSI C78.1 17 W 32 W 40 W 0.15 A 0.28 A 0.36 A 0.30 A 0.56 A 0.72 A cos p ) 0.97 capacitive; no additional compensation required When opening the light Switch with safety lock; when opening the central lock, all poles of the voltage supply to the ballast are disconnected; contacts of the switching element are NC contacts, they can only be switched on again when the lamp cover and the central locking system are closed. In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply. The electronic ballast, type 6042/9..-. fulfills the requirements according to IEC 61347-2-3 (simulation of the "end of life effect" of fluorescent lamps, "asymmetric pulse test 1" and "asymmetric power test 2" correspond to the test conditions in the draft IEC 60079-7 ed.4 appendix H). for lights of the versions 18 W 36 W 58 W with 2 lamps 0.18 A 0.33 A 0.49 A cos p ) 0.97 capacitive; no additional compensation required In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply. Lighting /3

Technical Data Luminous Characteristics Lamps Measures for light guidance Operational efficiency Ambient conditions Operating temperature range 18 (17) W: - 25... + 55 C 36 (32) W: - 25... + 55 C 58 (40) W: - 25... + 50 C - 30... + 55 C Mechanical data Degree of protection Protection class Material Enclosure IP66 IP64 when using the breather 8162 (according to EN 60529) I(with internal PE connection) IP66 IP64 when using the breathing gland 8162 (according to EN 60529) Polyester resin, glass fibre-reinforcedcolour white, similar to RAL 9010colour white, similar to RAL 9010 Gasket Polyurethane foam gasket in the lamp cover Lamp cover Polycarbonate Lamp locking Central locking which can be opened/closed using a socket key M8 / wrench size 13, hinged lamp cover Assembly / Installation Cable glands Standard light Connection Fluorescent lamps with two-pin cap; T8;cap G13, according to IEC 60081 Standard light: Side entry lamp: 1 x 18 W 1 x 36 W 1 x 58 W 1 x 18 W 1 x 36 W Fluorescent lamps with two-pin cap; T8; cap G13, according to ANSI C78.1 Standard light: Side entry lamp: Standard: Special 1 x 17 W 1 x 32 W 1 x 40 W 1 x 17 W 1 x 32 W 2 x 18 W 2 x 36 W 2 x 58 W 2 x 18 W 2 x 36 W 2 x 17 W 2 x 32 W 2 x 40 W 2 x 17 W 2 x 32 W Fluorescent lamps with two-pin cap; T8; cap G13, according to IEC 60081 Standard light: Side entry lamp: Deep bowl, reflector of the lamp is white Lateral dazzle limitation in the lamp cover 1 x 18 W 1 x 36 W 1 x 58 W 1 x 18 W 1 x 36 W 2 x 18 W 2 x 36 W 2 x 58 W 2 x 18 W 2 x 36 W Additional reflector (can be easily mounted), deep broad bowl, polished aluminium broad beam 18 W / 36 W / 58 W with 1 lamps with 2 lamps 83 % 76 % Plastic 1 x M25 x 1.5 cable gland 8161 and 2 x M25 x 1.5 stopping plugs 8290 (enclosed) Metal: 2 x metal plates M20 connected by means of PE for metal cable glands Attention: cable glands must be ordered separately Special: max. 4 holes M20, M25, NPT ½ max. 2 holes NPT ¾ Metal cable glands: M20, M25; earthing of the metal gland parts by means of metal plates Side entry lamp In case of a pole mount adapter mounted in factory: 1 x M32 x 1.5 cable gland 8161 1 x M25 x 1.5 stopping plugs 8290 (enclosed in the delivery) 1 x M25 x 1.5 breathing gland (enclosed in the delivery) Standard: Special Terminal block with cover Designation: L1 + N + PE (3-pin) or L1 + L2 + L3 + N + PE (5-pin) Terminal capacity: max 2 x 6 mm 2 (single-wire); 2 x 4 mm 2 (finely stranded) Cage clamp terminals Terminal capacity: max 2 x 2,5 mm 2 (single-wire); 2 x 2,5 mm 2 (finely stranded) (3 free terminals available) /4 Lighting

Technical Data Through wiring Assembly Monitoring module Function Monitoring and switching module for emergency light systems according to VDE 0108: The module is used for the monitoring of individual lights and for the control of network and safety lights. The module offers the following functions: Control of the light (ON / OFF) and function test Up to 20 addresses can be set for each electric circuit by means of a coding switch The operating mode of the lamp (continuous light, stand-by light or activation by means of a switch) is freely programmable Mixed operation within one circuit is possible Input voltage (Input between L+ and N-) Control input (between L and N) Connected power (output to light) Ambient temperature Dimensions Looping of the cables Through wiring L x W x H = 95 x 40 x 32 mm Standard light On the connection side, there are two possibilities M25 x 1.5 for the looping of the connecting line (entry and exit on one side), also possible with lights subsequently fitted with pole mount adapter. Standard light Lights are available with internal through wiring. Entry and exit holes for connecting cables are positioned on the opposite sides. A through-wiring kit can be installed later (see accessories). Terminals: see Technical data. Wiring cross-section 2.5 mm for max. 16 A For outdoor installation, a breathing gland is recommended Standard light Standard: 2 x M8 insert nuts in the enclosure Special: Mounting grooves in the enclosure for the use of fastening and ceiling rails for variable light installation (variable mounting distances for lights 18 W (17 W): 312... 465 mm; 36 W (32 W)/ 58 W (40 W): 670... 865 mm) A pole mount adapter can also be fitted to the standard light Side entry lamp The light is mounted on a tube adapter, diameter 42 mm, and fixed by means of a clamp. The pole mount adapter is mounted in factory; it is also possible to install it later on the standard light. Insertion of the connecting cable Factory-mounted pole mount adapter: The cable is led through the pole mount adapter into the light. The cable is sealed by means of a gland M32 x 1.5. U N U DC U N P When the pole mount adapter is mounted subsequently: 230 (+ 10 % / - 15 %) V AC, 50 Hz 175... 275 V DC 230 (+ 10 % / - 15 %) V AC, 50 Hz 4... 100 W T a (Module) - 10... + 50 C use the cable gland of the standard light Lighting /5

Accessories and Spare Parts Designation Illustration Description Art. no. Weight kg Fluorescent lamps Two-pin cap d 26 mm Light colour: universal white 04936E00 18 W 1350 Im 108952 0.100 36 W 3350 Im 58 W 5200 Im 108951 0.200 108950 0.220 Bracket for wall mounting with tube for side entry lamp; with tube, length 400 mm, d 42 mm 108947 2.480 Lamp cover Pole mount adapter 05460E00 05329E00 for lamp 18 W 115814 0.800 for lamp 36 W 115817 1.500 for lamp 58 W 115820 1.800 for the subsequent mounting on lights 18 W and 36 W, 115698 2.100 completely with assembly parts 05500E00 Lamp-holder Lamp holder G13 1 piece 117252 0.025 Switch 05696E00 Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.025 Mounting kit for through wiring Reflectors Socket key 10809E00 05503E00 05324E00 for the subsequent installation in standard lamps DV 5 with 5 conductors, 2,5 mm 2 for max. 16 A; L1, L2, L3, N, PE for lights 18 W 115806 0.400 for lights 36 W 115813 0.400 for lights 58 W 115819 0.440 DV3; screwed terminals 3 x 2.5 mm 2, max. 16 A L1 + N + PE for lights 18 W 115802 0.200 for lights 36 W 115810 0.240 for lights 58 W 115816 0.260 for later installation; broad deep bowl for lights with one lamp 18 W 115694 1.103 for lights with one lamp 36 W 115731 2.079 for lights with one lamp 58 W 115757 2.079 for lights with two lamps 18 W 115716 1.105 for lights with two lamps 36 W 115745 2.070 for lights with one lamp 58 W 115767 1.985 M8 / wrench size 13; 140486 0.126 to open/close the central locking 05321E00 /6 Lighting

Accessories and Spare Parts Designation Illustration Description Art. no. Weight kg Adapter plates for use together with metal cable glands; the metal cable glands are integrated in the earthing system via adapter plates 1 x M20 x 1.5 1 piece 115815 0.070 05755E00 1 x M25 x 1.5 1 piece 115818 0.070 1 x NPT 1 / 2 1 piece 1 x NPT 3 / 4 1 piece 2 x M20 x 1.5 1 piece 2 x M25 x 1.5 1 piece 2 x NPT 1 / 2 1 piece 115821 0.070 115824 0.070 115826 0.060 115828 0.060 115829 0.060 Mounting rail for a variable mounting distance 115719 0.330 05490E00 Mounting bracket Mounting clamp mounted on a mounting rail for a variable mounting distance; 115777 0.400 Ring bolt 05496E00 M8, direct mounting in insert nuts, 115736 0.120 Wall mounting bracket 90 05378E00 Material: stainless steel 115713 1.500 Wall mounting bracket 50 05555E00 Material: stainless steel 115691 1.200 05556E00 Top rail for ceiling suspension of the lamp 115733 0.280 05493E00 Pipe clamp with mounting rail for a variable mounting distance; Material: stainless steel R 1 1 / 2 115690 1.250 09402E00 R 2 115711 1.370 Breathing gland R 1 1 / 4 115728 1.250 M25 x 1.5 in order to avoid condensate formation 115738 0.020 05703E00 Safety device Ð Ð 203914 0.167 13076E00 Lighting /7

Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 04770E00 04771E00 Light 18 W 36 W 58 W L1 700 1310 1610 L2 1) 400 800 800 L3 2) 312... 465 670... 865 670... 865 b 221 221 221 h1 143 143 143 1) fixed mounting distance 2) variable mounting distance EXLUX 6000 und EXLUX 6400 Standard Light Dimensions in mm Dimensions in mm Light 18 W 36 W L1 724 1334 b 221 221 h1 213 213 EXLUX 6000 und EXLUX 6400 Side Entry Lamp Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm) - Subject to Alterations 148 Top rail 03245E00 04775E00 13077E00 Safety device 03241E00 04776E00 04774E00 04777E00 Mounting rail Wall mounting bracket 50 Wall mounting bracket 90 /8 Lighting

Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm) - Subject to Alterations Mounting brakket fitted in fixing bracket 04778E00 04700E00 04701E00 03257E00 for lights with one lamp Reflectors Ring bolt fitted in the insert nuts of the light 03260E00 Pipe clamp fitted in the fixing bracket for lights with two lamps 03262E00 Bracket for wall mounting with pipe section Reflector for light Reflector length in mm 18 W 554 36 W 1164 58 W 1464 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Lighting /9