DETAILED EQUIPMENT SPECIFICATION HIGH PURITY LABORATORY WATER SYSTEM

Similar documents
DETAILED EQUIPMENT SPECIFICATION MRO-4 SERIES REVERSE OSMOSIS SYSTEMS

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS

Reverse Osmosis Systems Section 11 Reverse Osmosis Systems

CAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER

INDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES

CAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø

PRESSURE GAGES AND TEST TAPS

Filtration Ft-Line 34. Ck-Line 38. Cp-Series 42. FilterMax 46. Cintropur filtration 51. Cartridge housings

TNT SERIES WATER CONDITIONERS

INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES

Hydrosafe - Model HSFS

SECTION 1. Fleck Fiberglass Softeners. *Shown with factory SKID & Interconnecting Plumbing

Reverse Osmosis (RO) Water Treatment Systems

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

BKI 1000 Commercial/Industrial RO Unit

Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover

WATER TREATMENT COMPONENTS. Residential R.O. components

SECTION H3 TRAYMASTER SERIES DEAERATORS

Assembled Engineered Systems. Softeners Filters Specialty Systems

Clean and soft water for business needs. Commercial softening equipment. COMMERCIAL WATER SOFTENERS

Duplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, with Steel Cover

Fleck Fiberglass Section 9 Chloride Dealkalizers

Fleck Top Mount Section 1 Fiberglass Softeners

DPS. The SSV Dual Pump System

AD-830. Parts Manual thru 1997

SOLICITATION C INSTALLATION AND MAINTENANCE OF POTABLE WATER FILTRATION SYSTEMS THROUGHOUT THE STATE OF FLORIDA QUESTIONS AND ANSWER

HYDRO ION Water softener Type: VAD CS

TABLE OF CONTENTS. A. Figure # 1 General System Drawing B. Figure # 2 Package One Controller Drawing C. Figure # 3 Package Two Controller Drawing

SECTION H4 BOILERMATE DEAERATORS

Residential R.O. components

Nautilus Gallon Per Day Modular Watermakers.

ALAMO WATER REFINERS REVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL R14-SERIES

Technical Manual. Models: Standard Softeners High Efficiency Softeners Combination Softeners S150 S250 S250 OD S350 S550 S650 S650 OD Q850 Q850 OD

SAMPLE SPECIFICATIONS

Aqualine Active Carbon Filters with surface piping

ROGERS MACHINERY COMPANY, INC

BLAKE WATER SOLUTIONS U.S. NORTHEAST REGION DISTRIBUTION CATALOG REV 09/09

W4100, W4200 & W4300 Electric Pump

MODEL 10LH SPECIFICATION

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

INSTALLATION, OPERATING AND SERVICE MANUAL

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

Pure Water. Anytime, Anywhere. Marine Desalination Systems

BoosterpaQ Hydro MPC-ED Guide Specification

Series CC Condensate Units

Spin Klin 12" Super Flow

Duplex Commercial Pressurizer -DCP

EQUIPMENT DATA SHEET RO

KP100 TJ3. RIG-SAFE Containerized unit

Pumps and Filtration

ROGERS MACHINERY COMPANY, INC

FILTRATION FOR ANY APPLICATION

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers

TYPE PC Propeller Condensate Pumps

390 Series Multi-Stage Vertical In-Line Centrifugal Pumps

Weld tabs are standard on all media tanks and screen filter housings.

245 W. Roosevelt Road Building 12, Suite 83 West Chicago, IL

BNT 85 /185 Valve Operation Manual

A. The latest published edition of a reference shall be applicable to this Project unless identified by a specific edition date.

Aqua Flo Point-of-Use Filtration Products. 76 Ultraviolet Disinfection Systems

Portable Liquid Pump and Filter Systems Compressed Air-Powered Pump and Filter System

A. Provide all HVAC specialties required to complete the installation of all HVAC systems. B. Manufacturers: Refer to individual product item.

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

EQUIPMENT DATA SHEET RO

Installation & Operating Manual

Oily Water Separators. globally focused on cleaner solutions

LEAD FREE * LFF113FP. Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology. Materials NOTICE NOTICE ES--LFF113FP

All-Fiberglass. Cooling Towers. The. HFC Series. High Performance & Quality with Maximum Durability CLOSED CIRCUIT FLUID COOLER

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes:

Model Q45H/ Residual Chlorine Monitor...

KEL DIFFERENTIAL PRESSURE FLOWMETERS

VERTICAL MULTI-STAGE PUMPS

EPDM,(Options for Buna, Viton - Depending on Process) B-7 All Thread w/ Stainless Sleeve

THE WATER EQUIPMENT SPECIALIST EST. 2000

Sample Specifications 2111_A00.doc 01/18/06 KOBELCO KNWA00 SERIES 1 of 8 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame HP

Iron Gate Air Pump System Manual

4500C Series Vortex Pumps

65 Series. Valve Operation Manual

EQUIPMENT DATA SHEET RO

EZ SERIES BOOSTER PUMPS

3 Spin Klin Battery Operation and Maintenance Manual

Smart controls Reliable operation User friendly design Plug and play operation

FILTERS, STRAINERS AND VALVES PRODUCT GUIDE

TotalPac 3 Non interlock Preaction system Pneumatic release

Darley UHP-HV Diesel Specification 1

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

IWT 565 Series Valve Operation Manual

Series 774 Automatic Skid Package

EMERGENCY GENERATOR SET

F76 Water Filters. Specifications. and MV876 Automatic-Backwash Control Accessory (not included)

COMMERCIAL UST ADD WATER BULLETIN; ISSUE 1

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

Fleck Epoxy Lined Section 2 Steel Softeners

TRANSFORMER OIL FILTRATION PLANT 6000 LPH CAPACITY TRANSFORMER OIL FILTRATION PLANT LPH CAPACITY

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

University of Houston Master Construction Specifications Insert Project Name

Transcription:

5356 Hillside Avenue Indianapolis, IN 46220 P: +1 888-56-Water (569-2837) F: +1 317-255-4727 info@nancrede.com www.nancrede.com DETAILED EQUIPMENT SPECIFICATION HIGH PURITY LABORATORY WATER SYSTEM 1.0 SCOPE 1.1 Provide as indicated a factory assembled high purity laboratory water system, including reverse osmosis and deionization, shipped for ease of installation and start up. The system shall be of an approved design as fabricated by a manufacturer regularly engaged in the production of water treatment equipment. All equipment and material shall be supplied per the specifications as intended for a complete and operational system. 1.2 Qualified manufacturers of water conditioning equipment shall be engaged in the manufacture of this type of equipment for a period of not less than (10) years. Acceptable manufacturers are Marlo, Inc. or engineer s approval equal. 2.0 GENERAL DESCRIPTION 2.1 The system, in compliance with equipment specifications, is described as an 3.0 DESIGN DATA 3.1 DESIGN PARAMETERS Design System Flow GPM (RO make-up) Design System Flow GPM at psig (Distribution loop) Daily Water Usage Gallons / Day Daily Hours of Water Demand Hours / Day Operating Temperature Range F Operating Pressure Range (System) PSIG Electrical Requirements Minimum Storage Tank Capacity Gal. 3.2 WATER ANALYSIS (insert accurate feed water quality report here) 3.3 DESIRED WATER QUALITY (insert required final water quality parameters here e.g. resistivity/conductivity, ph, etc.) 1

4.0 REVERSE OSMOSIS (RO) PRE-TREATMENT EQUIPMENT 4.1 INLET WATER TEMPERING VALVE A thermostatic water tempering valve shall be provided to increase the RO inlet water temperature to 75-77 F and improve machine output and performance. The valve shall include a bronze body, swivel action check stops, removable cartridge/strainer, stainless steel internal piston, temperature regulator dial, hot/cold water inlet shutoff valves, and outlet bimetal thermometer. Basis of Design: Symmons Series #5 4.2 MULTI-MEDIA FILTER A single multi-media filter properly sized for the inlet flow rate of the RO machine shall be provided for suspended solids removal down to the order of 10-20 micron. Media tank to be constructed of fiberglass reinforced polyester (FRP) designed for 150 psig. A pre-piped internal backwash distributor and filtered water collector shall be provided. The filter media shall consist of a top layer of anthracite, middle layer of silica sand, and bottom layer of multi-grade garnet. The filter media shall be provided separately in one (1) cubic foot bags and installed at the job-site. The automatic backwash cycle shall be performed by a top mounted, piston operated control valve with a pre-sized drain line flow control orifice. The backwash cycle to be initiated by an adjustable seven (7) day electro-mechanical calendar timeclcock. Basis of Design: Marlo MID Series 4.3 ACTIVATED CARBON FILTER A single activated carbon filter properly sized for the inlet flow rate of the RO machine shall be provided for the removal of chlorine and prevention of RO membrane damage. Media tank to be constructed of fiberglass reinforced polyester (FRP) designed for 150 psig. A pre-piped internal backwash distributor and filtered water collector shall be provided. The filter media shall consist of a 12 x 40 mesh, acid washed bituminous coal based activated carbon. The filter media shall be provided in one (1) cubic foot bags and installed at the job-site. The automatic backwash cycle shall be performed by a top mounted, piston operated control valve with a pre-sized drain line flow control orifice. The backwash cycle to be initiated by an adjustable seven (7) day electromechanical calendar timeclcock. Basis of Design: Marlo ACA Series 4.4 WATER SOFTENER A twin alternating water softener properly sized for the inlet flow rate of the RO machine and incoming water hardness shall be provided to prevent the scaling of RO membrane elements. Resin tank to be constructed of fiberglass reinforced polyester (FRP) designed for 150 psig. A pre-piped internal backwash distributor and soft water collector shall be provided. Softening resin shall have an exchange capacity of 30,000 grains per cubic foot when regenerated with 15 lbs of salt. The brine tank shall be constructed of rotationally molded polyethylene with snug-fitting cover. A float operated, air-check brine valve shall be provided to automatically measure the correct amount of brine to the softener unit and re-fill with fresh water. The softener regeneration shall be performed by a top-mounted, piston operated control valve with pre-sized flow controls and brine injector. An attached water meter shall monitor the volume of water processed and automatically initiate softener regeneration. An alternator controller shall be provided to permit only one vessel in service at any time. The second tank is to be in either regeneration or stand-by mode at any time. Basis of Design: Marlo MAT Series 5.0 RO MACHINE EQUIPMENT DESCRIPTION Basis of Design: Marlo MRO Series 5.1 RO MEMBRANE ELEMENTS The RO elements shall be thin-film composite (TFC) with an FRP or tape overwrap, anti-telescoping device and u-cup brine seal. The design salt rejection shall be 98% based on 2000-PPM water and 225 PSIG at 77 degrees F. 2

5.2 RO ELEMENT HOUSINGS The RO element housings shall be constructed of 304 stainless steel with PVC end caps. Stainless steel clamps hold the end caps in place. Each housing assembly is complete with one set of O-rings and O-ring lubricant. 5.3 HIGH PRESSURE PUMP AND MOTOR The pump shall be a centrifugal type constructed of 304 stainless steel casing, shaft, impellers, inlet and discharge castings. All pump bearings shall be tungsten carbide and ceramic. The pump shall have a cast iron frame with suction/discharge connections. A NEMA standard C-faced ODP motor shall be mounted to an adapter supported on the pump-bearing frame. The motor shall be rated for 3500 RPM. 5.4 ELECTRICAL CONTROL SYSTEM The control panel shall contain an illuminated selector switch indicating power OFF/ON, status/alarm lights, pre-wired motor starter (if applicable), power disconnect switch, control relays, and terminal blocks factory assembled and tested. Enclosure shall be NEMA 4X rated and constructed of FRP. A pressure switch shall be provided to shut down the RO pump in a low pressure condition. A pretreatment interlock indicator and control shall be provided to prevent RO operation when pretreatment equipment (such as the activated carbon filter) is off-line in the backwash or regeneration mode. An autoflush indicator and control shall be provided to flush RO concentrate from the machine at shutdown and/or pre-determined intervals. 5.5 INSTRUMENTATION Two (2) panel-mounted flowmeters, one product and one concentrate, shall be included. Panelmounted pressure gauges for inlet, cartridge filter outlet, RO feed, and RO concentrate shall be 316 stainless steel and liquid filled. A panel-mounted conductivity monitor shall be provided to measure the RO product quality (in microsiemens/cm). The monitor shall have a digital display, alarm relays, and automatic temperature compensation. The conductivity probe shall be mounted in the RO product outlet line and pre-wired to the conductivity monitor. 5.6 VALVES The pump throttle valve, concentrate throttle valve and recycle throttle valve shall be an in-line needle style, constructed of stainless steel and rated over 300 PSIG. The automatic inlet shutoff valve shall be a diaphragm type, solenoid actuated, normally closed, and constructed of brass or Noryl thermoplastic. The inlet isolation valve, product and concentrate check valves and sample valves shall be PVC with EPDM seats and seals. There shall be a sample valve for cartridge filter outlet, concentrate and product lines. 5.7 SEDIMENT PRE-FILTER A cartridge filter housing shall be provided in the RO machine inlet line and constructed of polypropylene and include a built-in pressure relief or vent valve. The filter element shall be constructed of spun-wound polypropylene and rated at 5-micron nominal. 5.8 SKID AND FRAME ASSEMBLY The entire RO machine shall be built on a skid and frame constructed of structural carbon steel and completely electrically welded. The entire surface shall be sand-blasted and finish painted with a Safety Blue self-priming, high solids epoxy overcoat. 5.9 PIPING All low pressure piping (75 psig or less) shall be constructed of Sch 80 PVC. RO product tubing from each membrane housing shall be reinforced PVC. All control and pressure gauge tubing shall be constructed of polyethylene. All high pressure piping (75 psig and higher) shall be constructed of 304 stainless steel and/or brass. Threaded and compression high pressure fittings constructed of stainless steel and brass is also acceptable. High pressure control and pressure gauge tubing shall be constructed of polyethylene. 3

5.10 ATMOSPHERIC STORAGE TANK The free-standing RO product water storage tank shall be constructed of linear polyethylene in one piece, seamless construction and closed-top, flat bottom design. The tank shall have a top opening for convenient access. PVC bulkhead fittings shall be installed for high / low-level switches, RO product inlet, RO product discharge, high purity water return, and drain. A 0.2-micron tank vent filter shall be installed in the top head of the tank. A pressure relief valve (PRV) constructed of PVC shall be installed in the high purity water distribution return line at the top of the storage tank. 5.11 STORAGE TANK LEVEL CONTROL An adjustable float switch assembly shall be provided for the product storage tank. Switches shall signal start and stop to the RO unit. A secondary adjustable float switch shall be provided for low tank level, and shall signal the shut-off of the repressurization pump. 5.12 WATER TEST KIT A comprehensive water quality testing kit shall be provided to field-measure total water hardness, total iron, free chlorine, and ph. 5.13 INSTRUCTIONS A set of three (3) complete Installation, Operation and Maintenance manuals shall be provided in three-ring binder form. As-built general arrangement, process and instrument, and electrical drawings shall be included. All component data, manuals, calibration documents shall also be included. A recommended on-hand spare parts list shall be provided. 5.14 WARRANTY The manufacturer shall provide an 18-month materials and workmanship warranty from the date of equipment shipment. Membrane element warranty is per the selected RO element manufacturer standard warranty. 6.0 RO POST-TREATMENT EQUIPMENT 6.1 RO WATER RE-PRESSURIZATION PUMPS Two (2) close coupled, single-stage centrifugal pumps suitable for the distribution of RO / ultra pure water shall be provided. One pump is designed as a dedicated piped and wired spare. Wetted components shall be constructed of 316 stainless steel with NPT suction / discharge connections. Motors shall be TEFC and rated for 3500 RPM, 460 VAC, three-phase, 60 Hz power supply. A NEMA-4X pump control panel constructed of fiberglass shall be provided with prewired motor starters, pump selector switch, pump run lights, low tank level alarm light, hand / off / auto switches, and pump run hour meters. Basis of Design: G&L NPE Series 6.2 MIXED-BED DEIONIZATION EXCHANGE POLISHING BOTTLES Furnish four (4) FRP pressure vessels filled with mixed-bed ion exchange resin sized for the laboratory water distribution flow. Vessels to be oriented in a parallel-series configuration with two (2) vessels serving as the primary service and two (2) vessels serving as the polisher. Vessels are to be provided with quick-disconnect hose couplings. At resin exhaustion, the primary vessels are removed and the replaced with the polishing vessels and the fresh tanks are placed in the polishing position. A dual-channel resistivity monitor shall be provided to indicate water purity after the primary vessels and after the polishing vessels. An alarm output shall be provided for out-of-range water purity indicating the need for a vessel change-out. Vessel change-outs with fresh resin are to be performed by the Owner s independently contracted service company. 6.3 ULTRAVIOLET LIGHT An ultraviolet water disinfection light shall be provided for the effective destruction of bacteria. The lamp wavelength shall be 254 nm with a 9,000 hour life. The pressure vessel shall be 316 stainless steel with NPT or flanged inlet / outlet connections. The UV lamp shall be housed in a heavy-duty quartz jacket. A NEMA-3R electrical control cabinet shall include an elapsed run time meter and ballast power indicator light. The ON / OFF control shall be wired through the pump control panel. Basis of Design: Ideal Horizons IH Series 4

6.4 POST-FILTER HOUSING Designed to trap sub-micron contaminants down stream of the UV light. Filter housing shall be constructed of natural polypropylene or 316 stainless steel and include a built-in pressure relief valve. The filter element shall be pleated polypropylene and rated 0.2 micron absolute. 7.0 SKID MOUNTED SYSTEM OPTION The RO machine, pre-treatment equipment, and post-treatment equipment (excluding the RO water storage tank) shall be provided completely mounted on a common skid and frame assembly constructed of welded structural carbon steel. All interconnecting piping and manual isolation/bypass valves between equipment shall be provided. Piping and valves prior to the RO water storage tank are to be constructed of Sch 80 PVC. Piping and valves for the distribution and post-treatment equipment after the RO water storage tank are to be constructed of: (Choose 1: Sch 80 PVC or butt fusion-welded high purity polypropylene). Electrical control panels and all interconnecting wiring are to be provided in a watertight flexible conduit. A single point electrical connections for three-phase and single-phase power shall be required. -END OF SECTION- 5